AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Similar documents
Analysis of Polyester by a Combination of Curie-Point Heating Techniques and Preparative Liquid Chromatography

Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer

Category Major Groups Products

Headspace Technology for GC and GC/MS: Features, benefits & applications

MATERIALS SCIENCE POLYMERS

Lecture No. (1) Introduction of Polymers

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

Understanding Gas Chromatography

2. Amorphous or Crystalline Structurally, polymers in the solid state may be amorphous or crystalline. When polymers are cooled from the molten state

GAS CHROMATOGRAPHY/MASS SPECTROSCOPY FOR PLASTICS FAILURE ANALYSIS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

CHAPTER 6 GAS CHROMATOGRAPHY

Optimization of Method Parameters for the Evaluation of USEPA Method Using a Purge and Trap with GC/MS

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

SCH4U Synthesis and Polymers. Synthesis Reactions and Addition and Condensation Polymers

HYPHENATED TECHNOLOGY GUIDE

Selection of a Capillary

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Chromatography. Gas Chromatography

ANALYSIS OF POLYMER BLENDS BY GPC-FTIR

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Gas Chromatography (GC)

Marine bio-inspired underwater contact adhesion

Size Exclusion Chromatography: Method Development

Experiment 5. Synthetic Polymers.

Secrets of GC Column Dimensions

Selection of a Capillary GC Column

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

Qualitative Profiling of Co-polymer Polyethylene Terephthalate through Multifunctional Pyrolyzer-GC/MS by various Thermal Treatment Techniques

Infrared Spectroscopy

Author. Abstract. Introduction

Chemistry Gas Chromatography: Separation of Volatile Organics

The vibrational spectroscopy of polymers

Water Injections in GC - Does Water Cause Bleed?

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

A polymer is a very large molecule that is built from monomers. A monomer is one of the repeating units that make up a polymer.

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Can you imagine a world without plastics? Plastic soft drink containers,

HYPHENATED TECHNOLOGY GUIDE

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Detection of Chemical Warfare Agents by Transportable GC/MS

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Introduction to GC/MS

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Anupam Chemicals.

Option D: Medicinal Chemistry

ORGANIC REACTIONS 14 APRIL 2015 Section A: Summary Notes

Analysis of Bakken Oil Samples

VINNOL SURFACE COATING RESINS PRODUCT OVERVIEW

Determination of Volatile Substances Proof of Food Adulteration

Accelerated Cure of Phenol-Formaldehyde Resins: Studies With Model Compounds

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

GC Instruments. GC Instruments - Sample Introduction

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Polymer Reaction Engineering

Chapter 27: Gas Chromatography

Introduction to Capillary GC

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

GC/MS Analysis Laboratory Report

Automated Characterization of Compounds in Fire Debris Samples

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Quiz Act # s Study Guide

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

2401 Gas (liquid) Chromatography

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

POLYMER SCIENCE : lecture 1. Dr. Hanaa J. Alshimary Second class Poly. Eng. Dep. Introduction of Polymers Polymer poly mer Monomer Polymerization

BRIEFING. Pharmacopeial Discussion Group Sign Off Document Attributes EP JP USP Definition Loss on drying Readily carbonizable substances

Hyphenated micro-ta techniques

Application Note. Abstract. Authors. Introduction

Trajan SGE GC Columns

Organic Chemistry. Radical Reactions

A fast, easy and green thermal desorption-gc/ms method for the analysis of phthalate esters in PVC

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Figure 4.10 HPLC Chromatogram of the Carbazole-Phenoxy Based Methacrylate

Elemental Analysis: CHNS/O characterization of polymers and plastics

(1) Recall the classification system for substituted alkenes. (2) Look at the alkene indicated. Count the number of bonds to non-hydrogen groups.

The AccuTOF -DART 4G: The Ambient Ionization Toolbox

How To Select the Correct GC Column. Simon Jones Application Engineer

POLYSTYRENE (General purpose)(gpps)


1.1 Basic Polymer Chemistry. 1.2 Polymer Nomenclature. 1.3 Polymer Synthesis. 1.4 Chain Growth Polymerization. Polymer =

Chemical Recycling of Unsaturated Polyester Resin and Its Composites via Selective Cleavage of ester Bond

Determination of Hydrocarbon Components in Petroleum Naphthas

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Transcription:

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION Paper # 164-8P Pittsburgh Conference 24 T. Wampler, C. Zawodny, L. Mancini CDS Analytical, Inc 465 Limestone Road, Oxford, PA 19363

ABSTRACT The full characterization of a polymeric system may include the analysis of retained volatiles such as solvents and monomers, semi-volatile additives such as plasticizers and the identification of the polymer itself, or quantitation of monomers in copolymers. Gas chromatography and mass spectrometry have been used successfully for these various analyses by combining solvent extractions, headspace sampling, pyrolysis and other sample preparation techniques. This paper presents a simple approach to polymer characterization using sample temperature as the only preparation technique. Accurate temperature control permits the selection of different fractions of organics based on volatility. Low temperatures are employed for the removal of small molecules, moderate temperatures for semi-volatiles and very high temperatures for thermolysis of the polymer, so that all constituents may be volatilized and studied, either by GC-MS or directly to the mass spectrometer. The system described includes a temperature based sample preparation station and a mass spectrometer, which may be used with or without GC separation. Modes of operation include low temperature thermal desorption with trapping and analysis by GC, pyrolysis with GC-MS for detailed macromolecular structure analysis, pyrolysis direct to MS for rapid polymer identification and programmed heating for thermal resolution direct to the mass spec. In the last case, the sample is heated at a controlled rate by the pyrolysis coil, with the evolved products transferred directly to the mass spectrometer for analysis through fused silica tubing. EXPERIMENTAL ANALYTICAL CONDITIONS - PYROLYSIS Pyrolyzer: CDS Analytical Pyroprobe 5 Filament: Coil, Platinum Interface: Model 15 ANALYTICAL CONDITIONS - GAS CHROMATOGRAPHY Instrument: Agilent 689 Column: 3 m x.25 mm HP-5 Program: Initial 4 C for 2 minutes Ramp 1 C/minute Final 3 C Carrier: Helium Split: 5:1 ANALYTICAL CONDITIONS - MASS SPECTROMETER Instrument: Agilent 5973 MSD Range: 2-6 AMU Examples show the analysis of real world samples such as tire rubber, vinyl film, textile fibers, treated papers and adhesives. INTRODUCTION A finished polymer product is comprised of many components, both intentional, such as the various monomers used for a copolymer, antioxidants, plasticisers, and unintentional, including residual monomers, solvents and contamination. Low molecular weight components, volatiles like solvents and monomers, may be extracted with various degrees of effectiveness, depending on the polymer matrix (crosslinking, etc.). Once extracted, the assay depends at least in part on how the presence of a solvent peak interferes with the compounds of interest, themselves frequently solvents. This problem may be alleviated by performing headspace - either static or dynamic - as one step in the polymer analysis. Thermal sampling such as pulse pyrolysis provides much information about polymers, including copolymers and semivolatiles like plasticisers and lubricants. Figure 1, for example, shows analytical results from a sample of a clear packaging material, in which may be seen peaks for the monomers used to formulate the polymer (including styrene, methyl methacrylate and PVC) as well as for the semivolatile plasticizer added to the product. A more complete picture of such complex polymers may be produced by the careful selection of a series of temperatures which transfer various fractions of the material to the GC for analysis, without the use of solvent extraction, dilution or additional sample manipulation. FIGURE 1. Pyrolysis at 7 C of a molded packaging product made from polystyrene, polymethyl methacrylate and polyvinyl chloride. The HCl, Benzene and Toluene are pyrolysis products of PVC. 1. HCl 2. Benzene 3. Methyl methacrylate 4. Toluene 5. Styrene 6. Bis 2-ethylhexyl phthalate (DOP)

RESULTS A simple pyrolysis, coupled with gas chromatography or GC/MS is frequently enough to identify or differentiate polymeric materials. Sample preparation generally consists of merely taking a piece that is about 5 µg and placing it into the pyrolyzer. The sample is then heated very quickly to a high temperature at the beginning of the GC run. The volatile compounds produced from the sample are delivered directly to the GC column, and the chromatography proceeds as it would for any other sample introduction technique. In Figure 2, a sample of material formed into a small bead used in jewelry was pyrolyzed at 65 C. True amber is a fossilized tree resin, which forms complex terpenoid structures. The sample in this case produced only a series of phenols when pyrolyzed, and none of the typical fragments seen in a true amber, indicating that it is not a sample of amber, or even a natural product, but a synthetic resin. In Figure 3, a sample of real amber from Lebanon was pyrolyzed under the same conditions. The complex pyrogram which results contains many hydrocarbons, saturated and unsaturated, including cyclic compounds. The large peak just after 5 minutes, for example, is dimethyl cyclohexene. FIGURE 2. Pyrolysis of amber colored bead. 1. Phenol 2. 2-methyl phenol 3. 4-methyl phenol 4. 2,4-dimethyl phenol For Figure 4, the adhesive from a sample of clear packaging tape was removed from the polymer film that made the tape. The adhesive by itself was then pyrolyzed for the chromatogram. The results show a fairly wide distribution of compounds, including alcohols, hydrocarbons and esters. Some of the peaks identified include: Retention time Compound 2.6 min Acetic acid 3.1 Butanol 4.1 3-methylene Heptane 5.8 Butyl acetate 7.7 Butyl acrylate 1.2 2-ethyl Hexanol along with longer chain acrylic compounds. When acrylic polymers with long chain ester groups are pyrolyzed, they usually from some of the monomer (as in the butyl acrylate) as well as some of the corresponding alcohol (here, butanol). The adhesive then is made from a mixture of acrylic compounds, including butyl and octyl esters. The two sets of peaks at about 22 minutes and at 26 minutes may be dimers, and will be seen again in a stepwise analysis of the whole tape. FIGURE 3. Pyrolysis of true amber from Lebanon. FIGURE 4. Pyrolysis of adhesive from clear tape.

MULTI-STEP ANALYSIS A single run of the whole tape, from which the adhesive was taken for Figure 4, would include peaks for pyrolysis products from the adhesive, plus the polymer film, in addition to volatile and semivolatile compounds like residual solvents, monomers and additives. A multi-step approach, taking the sample material stepwise to increasingly higher temperatures, may help separate some of the compounds and simplify the analysis. In this series, a 1.25 mm circle of the tape was heated sequentially to 1, 2, 4 and finally 65 C, for a few seconds each time. At 1 C, only a few very small peaks are seen from the sample. Figure 6 shows that at 2, some compounds are beginning to be released from the tape and adhesive matrix, including a phthalate plasticizer at 23 minutes and another at 28 minutes. FIGURE 5. Whole tape at 1 C. At 4 C, the largest peak is for 2-ethyl hexanol, which was also seen in the analysis of the adhesive in Figure 4. This is a breakdown product from one of the acrylics used to in the adhesive. Beyond that, there are the two sets of peaks at about 23 and 26 minutes, also prominent in the single step analysis of the adhesive. Earlier eluters include acetic acid, butanol, 3-methylene heptane and butyl acetate. So most of the compounds released from the sample at 4 C may be associated with the adhesive and not with the polymer film used for the tape itself. It isn t until the run at 65 that evidence of the tape polymer is seen. Now, in addition to many of the peaks seen earlier, there is a series of hydrocarbons, starting with the dimethyl heptene indicated in Figure 8. This compound is the trimer of propene and always the largest peak in a pyrogram of polypropylene. Other oligomers of propylene may be seen at about 1 minutes (the tetramer) and 15 minutes (the pentamer). From this series, then, the tape may be deformulated and shown to be comprised of a polypropylene film with an acrylic adhesive and phthalate plasticizers. FIGURE 6. Whole tape at 2 C. OH FIGURE 7. Whole tape at 4 C. FIGURE 8. Whole tape at 65 C.

2 4 6 8 1 12 14 16 18 2 22 24 26 28 3 3 DIRECT TO MS PULSE AND PROGRAMMED 69 87 Scan 29 (.254 min): P5MS3.D 41 An alternative to stepwise chromatographic analysis is to interface the pyrolyzer directly to the mass spectrometer and perform either pulse or programmed heating of the sample. The results are obtained faster, and reveal the relative temperatures at which some products are formed, but the mass spectra may be complex when dealing with a multi-component system, and may rely on chromatographic runs to help sort things out. 56 27 113 1 127143156 27223 169184 263 281 In these runs, the GC column was removed and replaced with a 1 m long piece of.1 mm fused silica. The injection port, split ratio and pyrolysis interface were left the same as for the chromatographic runs. The GC oven was set to 2 C isothermal. Figure 9 shows a pulse pyrolysis at 65 C of poly butyl methacrylate, with data collected for a total of one minute. Like other methacrylates, PBMA mostly unzips to form monomer, and the mass spectrum obtained throughout the peak is identified as butyl methacrylate. If the same polymer is heated through a range of temperatures, as in Figure 1, more information is obtained. In this case, there is an early, small peak, then a large peak as the sample is pyrolyzed. Both peaks have the same mass spectrum, and the first peak represents the residual butyl methacrylate (and other volatiles) being released from the polymer before pyrolysis. FIGURE 9. Pyrolysis of Poly butyl methacrylate at 65 C. For Figure 11 a small piece of glossy coated paper was heated, again at 1 /minute. The main peak at about 4.5 minutes consists of heavily oxygenated compounds resulting from the cellulose used to make the paper. After this peak, there is a smaller peak at about 6.5 minutes. The mass spectra in this area contain masses seen in the paper pyrolysis, plus a large peak for mass 14, which comes from the styrene used in the coating of the paper. Figure 1. PBMA heated at 1 C/minute. 6 Scan 181 (6.547 min When a piece of clear vinyl film is heated under these conditions, several peaks are produced, as shown in Figure 12. Phthalic anhydride, from a plasticizer, is seen in the early region labeled A in the figure. As poly vinyl chloride is heated, it degrades by a twostep process, First, at relatively low temperatures, the chlorine is removed from the polymer as HCl. This leaves behind a highly unsaturated backbone, which, upon further heating produces cyclic compounds, including benzene, toluene, xlyenes and naphthalene. In Figure 12, the peak labeled B consists mainly of mass 36, showing the evolution of HCl from the PVC. Finally, the peak marked C contains, among other things, mass spectra with a large peak at mass 91, showing the production of toluene. CONCLUSIONS 14 73 29 43 91 115 126 137 152 1 2 4 6 8 1 12 14 16 Figure 11. Coated Paper heated at 1 C/minute. Careful selection and control of sample temperature may be used to replace many time consuming steps in the characterization of polymeric materials. The sample may be heated to a series of temperatures to separate volatile and semi-volatile components from the polymer matrix, then pyrolyzed to reveal the structure of the polymer itself. As an alternative, the sample may be heated directly to the mass spectrometer to obtain temperature resolved data. For complex samples, chromatographic analysis first may indicate specific compounds or masses are significant in the faster direct or programmed runs. Figure 12. Clear vinyl film heated at 1 C/minute.