Minimum Detectable Activity Estimates for a Germanium-Detector Based Spectroscopic Portal Monitor

Similar documents
Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

The Shape of the Full-Energy Gamma Ray Peak in Germanium Detectors for Different Energies and Incident Geometries

EFFICIENCY AND RESOLUTION OF GERMANIUM DETECTORS AS A FUNCTION OF ENERGY AND INCIDENT GEOMETRY

PROFILE S and C Series P-type Semi-planar and Coaxial HPGe Detectors

A Digital Method for Dead Time Compensation in Nuclear Spectroscopy

Compton suppression spectrometry

Performance of the True Coincidence Correction Method in GammaVision. Keyser, Ronald M., Haywood, Susan E., and Upp, Daniel L.

Utilization of advanced clutter suppression algorithms for improved spectroscopic portal capability against radionuclide threats

Neutron Detector Gamma Insensitivity Criteria

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

PROFILE S and C Series

ENERGY PEAK STABILITY WITH COUNT RATE FOR DIGITAL AND ANALOG SPECTROMETERS

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Practical Solutions to Radioactive Waste Characterization

Calibration of A Small Anode Germanium Well Detector

NGN PhD Studentship Proposal

Recent improvements in on-site detection and identification of radioactive and nuclear material

WM2016 Conference, March 6 10, 2016, Phoenix, Arizona, USA. Recovering New Type of Sources by Off-Site Source Recovery Project for WIPP Disposal-16604

Field Tests of a NaI(Tl)-Based Vehicle Portal Monitor at Border Crossings

Design of a virtual model of a hand-held Germanium detector and a voxelized ICRP whole body phantom: A Monte Carlo study

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

Application of Spectral Summing to Indeterminate Suspect Low-Level Drums at Los Alamos National Laboratory

DESIGN, DEVELOPMENT AND TESTING OF AN AUTOMATED SEGMENTED GAMMA SCANNER FOR MEASURING NUCLEAR POWER STATION RADIOACTIVE WASTE

NUCL 3000/5030 Laboratory 2 Fall 2013

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona USA. Screening and Spectral Summing of LANL Empty Waste Drums 13226

DEVELOPMENT OF A REAL-TIME DETECTION STRATEGY FOR MATERIAL ACCOUNTANCY AND PROCESS MONITORING DURING

The Use of Self-Induced XRF to Quantify the Pu Content in PWR Spent Nuclear Fuel

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

JRPR. The Development of Gamma Energy Identifying Algorithm for Compact Radiation Sensors Using Stepwise Refinement Technique.

Study well-shaped germanium detectors for lowbackground

1 of :32

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Seaborg s Plutonium?

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

Application of Spectral Summing to Suspect Low Level Debris Drums at Los Alamos National Laboratory

Uncertainty Quantification for Safeguards Measurements

The Best Gamma-Ray Detector

PYCKO SCIENTIFIC LIMITED

Detection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods. Abstract

Determination of the activity of radionuclides

VIRTUAL GAMMA-RAY SPECTROMETRY FOR TEMPLATE-MATCHING NUCLEAR WARHEAD VERIFICATION. Janet Schirm and Alexander Glaser

FIRST LINE INSPECTION: RADIATION DETECTION

Computational study to enhance threat detection of radiation portal monitors:

European Project Metrology for Radioactive Waste Management

General Overview of Radiation Detection and Equipment

Spectral Analysis for the High Efficiency Multimode Imager

Compton Camera. Compton Camera

Renewed whole-body counting chamber in STUK

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES

MCNP6 simulation validation of fast neutron coincidence detection system for nuclear security and safeguards applications

Library of uranium and plutonium reference spectra Introduction

AIR FORCE INSTITUTE OF TECHNOLOGY

ORTEC was founded in 1960 by researchers from Oak Ridge National Labs to commercialize charged particle detectors

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Fissile material experiments at the Device Assembly Facility

1 Introduction. 2 Method. Robert Metzger 1,*, Kenneth Van Riper 2, and George Lasche 3

SLAC Metal Clearance Program and Progress

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

How Histogramming and Counting Statistics Affect Peak Position Precision. D. A. Gedcke

Identification of Naturally Occurring Radioactive Material in Sand

Correlations in Prompt Neutrons and Gamma Rays from Fission

24th Seismic Research Review Nuclear Explosion Monitoring: Innovation and Integration

An introduction to Neutron Resonance Densitometry (Short Summary)

ORTEC. GLP Series Planar HPGe Low-Energy Detector Product Configuration Guide. Configuration Guidelines

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Digital simulation of neutron and gamma measurement devices

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

Gamma-Spectrum Generator

Ultra-Low Background Counting and Assay Studies At SNOLAB

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

ORTEC. Overview of Semiconductor Photon Detectors. GEM (P-type) and GAMMA-X (N-type) Coaxial Detectors. Efficiency as a Function of Energy

Application of a Laser-Wakefield Driven Monochromatic Photon Source to Nuclear Resonance Fluorescence

Name of research institute or organization: Bundesamt für Gesundheit, Sektion Umweltradioaktivität, Bern

in Cross-Section Data

5) Measurement of Nuclear Radiation (1)

IPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet

COUNT RATE EFFECTS ON PEAK SHAPE AND THROUGHPUT IN DIGITAL AND ANALOG GAMMA RAY SPECTROMETRY

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

Investigation of Uncertainty Sources in the Determination of Gamma Emitting Radionuclides in the WBC

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Statistical Uncertainty What, When, Why and How RETS/REMP Workshop Jim Key Key Solutions, Inc.

Establishing an ISO-CART Measurement Station to Meet Government Burial Regulations for Radioactive Material

AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING

EXPERIMENTAL DETERMINATION OF THE URANIUM ENRICHMENT RATIO

ARACOR Eagle- Matched Operations and Neutron Detector Performance Tests

THE COMPTON EFFECT Last Revised: January 5, 2007

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

The Evaluation of Program ISOTOPIC to Nondestructively Quantify Uranium and Plutonium Samples at the Joint Research Center in Ispra, Italy

Scintillation Spectroscopy for Detection of Depleted Uranium

Characterization of Large Structures & Components

Transcription:

Log 121 Minimum Detectable Activity Estimates for a Germanium-Detector Based Spectroscopic Portal Monitor Ronald M. Keyser, Frank Sergent, Timothy R. Twomey, Daniel L. Upp ORTEC 801 South Illinois Avenue Oak Ridge, TN, 37831 USA Ron.keyser@ortec-online.com, frank.sergent@ortec-online.com, tim.twomey@ortec-online.com, dan.upp@ortec-online.com Abstract The Minimum Detectable Activity (MDA) for identification is one of several important performance measures for Advanced Spectroscopic Portal Monitors (ASP) given in ANSI N42.38 (draft) to determine the effectiveness of the ASP. In most spectroscopic applications, the samples are counted for a sufficiently long time to achieve the required minimum detectable activity or until the measured activities are within the desired statistical limits. However, in the ASP, the counting time is defined by the transit time of the vehicle or container through the portal field of view. For the specified transit speed and field of view, this gives a data collection time of a non-distributed source of 3 to 8 seconds. The performance criteria for a specified nuclide are stated in terms of the minimum detectable activity and in addition, at that stated activity limit, the number of false negatives must be less than 5 %, while the number of false positives in the same situation must be less than 1 in 1000. This low number of false negatives and false positives defines where the threshold for declaration of detection or identification should be set. This threshold must be based on some parameter derived from the spectrum, but is not necessarily only the activity of the nuclide. In addition, it is not desirable to use the concept of blank MDA, as used in sample counting, (which would correspond to measuring the background when the portal was unoccupied), because changes (normally suppression) to the background count-rate occur because of the presence of the vehicle and its cargo. Ideally, therefore, this parameter must be determined dynamically from the actual spectrum collected and compared to the threshold to determine if the nuclide is present. To determine the MDA for the ORTEC ASP, the detection parameter threshold was determined by modeling the portal monitor performance using measured efficiencies of the germanium detectors at the geometries specified in ANSI N42.38 and specifying the maximum number of false negatives and false positives to be as required in the standard. Then the parameter value was calculated on measured spectra for the geometries and measurement conditions (speed and distance) and for a range of nuclide activities. Using these measurements, a function can be determined relating the parameter value and the activity. From this function, the activity at the parameter threshold can be determined, which is the portal MDA for the tested geometry.

Results are shown for 133 Ba, 137 Cs, 60 Co, and 241 Am for the ORTEC HPGe portal. These MDA predictions are compared to the requirements of ANSI N42.38. Justification The minimum quantity of radioactive material that can be detected and identified in an Advanced Spectroscopic Portal Monitor with the desired precision is one of the major design considerations for the detector size and placement, as well as the number (or total efficiency) of detectors. The identification can be based on one peak or on several peaks and energy regions. In addition, the identification must satisfy the false negative and false positive requirements. None of the standards developed to date (e.g., ANSI N42.38 draft) include any methodology for calculating this value. To accommodate the requirements, a method has been developed to estimate the minimum quantity able to be identified, where the identification is based on the peak quality of the nuclide peaks in the portal spectrum. The method is based on empirically determined detector efficiencies, the required false negative and positive rates, and the mean identification peak parameter for repeated portal occupancies of a range of nuclide activities. The identification of a nuclide relies on the peak quality value and not directly on the counts in the peak region above a background spectrum. Introduction The Advanced Spectroscopy Portal (ASP) program is a DNDO activity aimed at the improvement of radiation portal monitors (RPM) of many types: cargo, passenger vehicle, rail, pedestrian, and vehicle mounted. The objective is to improve the ability of the portals to not only detect but also identify radionuclides passing by the detectors. An additional objective is to improve nuclide identification in situations where several nuclides are present which might confuse, intentionally or otherwise, an RPM into failing to report the actual nuclides. In particular, correct identification of natural, medical and nuclear materials is of high importance, whether the nuclides are seen singly or in multiplies; shielded or unshielded. ORTEC participated in the first round of ASP testing, supplying a prototype cargo portal system for evaluation at the Nevada Test Site (NTS) in the summer of 2005. As a consequence, a model for prediction of the monitor performance was developed. Equipment The prototype cargo portal system detector configuration is shown in Fig. 1 and described more completely in previous works [1, 2]. The system consists of two radiation sensor panels (RSP) of 6 detectors each on each side of the traffic lane for a total of 24 high purity germanium (HPGe) detectors. Testing was carried out over several weeks on a complete system at NTS and additional tests were done on a single RSP at the ORTEC facility in Oak Ridge, TN. Figure 1Prototype Cargo Portal on test site. Photo courtesy of National Nuclear Security Administration/Nevada Site Office

All HPGe detectors used were PROFILE GEM type, with crystal dimensions of 85 mm diameter and 30 mm long. The performance of all of the individual detectors, being nearly identical, could be easily predicted with a model of a single detector. The choice of detector length and diameter was based on Monte-Carlo efficiency modeling which was subsequently validated by experiment. The choice was made in such a way as to make a reasonable compromise between number of detectors, the sensitivity and uniformity of response across the portal detection zone. The length/diameter ratio combined with the number and spacing of detectors determine the uniformity of response within the zone. The initial choice of 6 each 85 mm x 30 mm detectors per panel was made with the major emphasis on sensitivity and detection zone uniformity. Performance modeling The nuclide identification scheme uses a peak quality factor to quantify the quality of a gamma-ray peak in the spectral data. This quality factor, Q, is defined as Where: G represents the gross counts in a region of the spectrum centered at the gamma-ray peak energy with a width based on the FWHM, B represents the number of background counts in the same region, represents the uncertainty of value: G-B. The numerator of this equation represents the signal or net counts in the peak. The denominator is the statistical error expected in the signal. Similar peak factors have been reported by others [3, 4]. The peak is determined to be present when the computed value of Q is above a set threshold value. If the peak (or peaks) for a nuclide are present and certain other isotope specific criteria are met, the isotope is judged to be present In order to predict detection and identification performance of the cargo portal and to predict performance in a variety of other configurations, an empirical model was developed. This model calculates Q probability distributions, for nuclides positioned throughout the detection zone as a function of number and separation of detectors, vehicular speed, and collimator field of view.

The model requires the following inputs: Fixed model input parameters HPGe Detector efficiency versus energy, distance and angle HPGe energy resolution versus energy Collimator field of view Variable input parameters Background spectrum seen by detector Source type (nuclide) Source distance from detector Source speed through detection zone Number of detectors per RSP vertical position of the detectors One or two sided configuration Desired detection probability Desired false alarm probability The efficiency of a single detector as a function of source position in front of the RSP is shown in Fig. 2 [2]. The positioning of the source in the collection time window can cause the maximum count to vary by ± 6%, but the total number of counts is the same over the width of the total time window used in the model. The predicted Q distributions were validated by comparing the predictions with distributions derived from data from the prototype testing. Using the Q probability distributions from background spectra (no source in the monitor) and from simulated nuclide peak areas, it is possible to predict the minimum amount of a specific nuclide that can be detectable and the amount needed for identification, given the requirements for false negatives and false alarms. Figure 3 shows the probability Figure 2 Modeled efficiency for 137Cs at 50 cm vertical distance from detector shield. Figure 3 Gaussian distributions for base line and activity.

distribution of Q for a specific nuclide using a single gamma ray peak using the background or blank spectra. (See Ref. 5) Integrating these curves from the minimum value to some value q, gives the total probability that Q will be below q as shown in Fig. 4. The Q calculations for the background spectra are the Blank (left most) curve. For a false positive probability of 1 in 1000, the integral of the function is 0.999. The value of Q corresponding to this value is the threshold value for 1:1000 false positive rate because any positive indication on the background is a false positive. In Fig. 4, this is a Figure 4 Example of a model generated detection probability distribution. value of 4.4. That is, for the expected distribution of Q for the background spectra, Q will be above 4.4 for 1 time in 1000 tests (occupancies). Thus the threshold, QT, can be set at 4.4 to achieve the false positive rate. A threshold value is the value above which an identification or detection is said to have occurred. Using the efficiency data, the Q distribution can be calculated for any activity as shown by the Larger Activity (right most) curve in Fig. 4. With the threshold set at 4.4, the Q curves can be calculated for the activity where the cumulative probability has a value of 0.05 at a q of 4.4 corresponding to a 5% false negative rate. This activity is then the minimum identifiable activity (MIA). Figure 4 shows the benefit of using HPGe detectors which is the separation between the probability distribution of background and typical sources is large. The large separation between the probability distributions of the source of interest and the background are due to the good resolution of the Germanium detector. Results The validated model can be used to calculate the MIA for a given set of conditions for nuclides for which spectra are available. The set of conditions used here are: cargo configuration with 24 detectors, spaced uniformly at 40 cm, 8 kph, FAP 1:1000 and greater than 95% Detection Probability (DP).

The MIA varies over the detection zone because of the varying distances from the source to the detector. Figure 5 shows the form of a typical detection limit (MIA) curve for the system of 24 detectors and for the source position to be at 50 and 250 cm from the detectors. This is from the closest position and the midpoint of the zone. The vertical position is from the base of the panel to the maximum active height of the cargo portal. The 137 Cs source is traveling at 8 kph. The MIA variation over the zone for other energies (nuclides) is similar, but the actual activities depend on the nuclide. Figure 5 Variation of the Minimum Identifiable Activity over the vertical position in the field of view. Table I shows predictions from the validated model for nuclide listed in ANSI N42.38. The first column is the nuclide. The second column is the required minimum activity for identification in the ANSI N42.38 specification. The third column for each nuclide is the Q value predicted for the required identification activity (column 2) and the last column is the minimum identification which is acheived when the Q value threshold is set for FAP of 1:1000 and DP of 95%. Table I. Detection Limits for Some Nuclides in a 24-Detector Cargo Portal Source Required Identify Activity (:Ci) ANSI N42.38 Mean Q at Required Identify Activity (:Ci) Minimum Identifiable Activity (:Ci) 241Am 47 19.20 8.77 133Ba 9 11.47 3.44 137Cs 16 14.99 3.00 60Co 7 8.02 2.29 Clearly, the 24-detector system far exceeds the ANSI requirements for these nuclides. Conclusion A semi-empirical model has been developed to predict the MIA for various configurations of HPGe detectors in portal monitors, handheld units and other configurations. It has been validated for a 2-sided cargo portal using data from testing at NTS and ORTEC. Using this model, the performance of 24-detector cargo portal is shown to be much better than the ANSI N42.38 requirements. Future

work will concentrate further on other configurations of monitors and search instruments using HPGe detectors.

References 1. Ronald Keyser, Advanced Spectroscopy Portal (ASP), INMM Fall Meeting, Oak Ridge, TN. 2. Ronald M. Keyser, Walter Hensley, Timothy R. Twomey, and Daniel L.Upp, Comparison of MCNP and Experimental Measurements for an HPGe-based Spectroscopy Portal Monitor, MARC VI Conference, April 2006, Hilo, HI 3. M. Wojcik and G. Zuzel, A High-Sensitivity Large Volume Cryogenic Detector for Radon in Gas, MARC VI Conference, April 2006, Hilo, HI 4. Pertti A. Aarnio, Jarmo J. Ala-Heikkilä, and Timo T. Hakulinen, Performance of UniSampo-Shaman with Gamma-Ray Spectra Containing Known Traces of Fission Products, MARC VI Conference, April 2006, Hilo, HI 5. W.H. Chambers, H.F. Atwater, P.E.Fehlau, R.D Hastings, C.N. Henry, W.E.Kunz, T.E.Sampson, T.H.Whittlesey, and G.M.Worth, LA-5681 Portal Monitor for Diversion Safeguards, Los Alamos National Laboratory Report, 1974