CONTROL OF MULTIVARIABLE PROCESSES

Similar documents
Solutions for Tutorial 10 Stability Analysis

CHAPTER 13: FEEDBACK PERFORMANCE

PROCESS CONTROL DESIGN PASI 2005

Solutions for Tutorial 4 Modelling of Non-Linear Systems

CHAPTER 15: FEEDFORWARD CONTROL

CHAPTER 10: STABILITY &TUNING

Control of MIMO processes. 1. Introduction. Control of MIMO processes. Control of Multiple-Input, Multiple Output (MIMO) Processes

Process Unit Control System Design

BITS-Pilani Dubai, International Academic City, Dubai Second Semester. Academic Year

CHAPTER 3 : MATHEMATICAL MODELLING PRINCIPLES

Multi-Loop Control. Department of Chemical Engineering,

Solutions for Tutorial 3 Modelling of Dynamic Systems

CHAPTER 2 CONTINUOUS STIRRED TANK REACTOR PROCESS DESCRIPTION

Chemical Reaction Engineering

Fundamental Principles of Process Control

Theoretical Models of Chemical Processes

Enhanced Single-Loop Control Strategies (Advanced Control) Cascade Control Time-Delay Compensation Inferential Control Selective and Override Control

Multi-Input Multi-output (MIMO) Processes CBE495 LECTURE III CONTROL OF MULTI INPUT MULTI OUTPUT PROCESSES. Professor Dae Ryook Yang

Chemical Reaction Engineering Prof. Jayant Modak Department of Chemical Engineering Indian Institute of Science, Bangalore

Process Control Exercise 2

3.1 Overview 3.2 Process and control-loop interactions

Class 27: Block Diagrams

CHBE320 LECTURE XI CONTROLLER DESIGN AND PID CONTOLLER TUNING. Professor Dae Ryook Yang

Process Control & Design

Process Solutions. Process Dynamics. The Fundamental Principle of Process Control. APC Techniques Dynamics 2-1. Page 2-1

Guide to Selected Process Examples :ili3g eil;]iil

Subject: Introduction to Process Control. Week 01, Lectures 01 02, Spring Content

Enhanced Single-Loop Control Strategies Chapter 16

Improved Identification and Control of 2-by-2 MIMO System using Relay Feedback

CM 3310 Process Control, Spring Lecture 21

Design of Multivariable Neural Controllers Using a Classical Approach

Process Control, 3P4 Assignment 6

Overview of Control System Design

Advanced Chemical Reaction Engineering Prof. H. S. Shankar Department of Chemical Engineering IIT Bombay. Lecture - 03 Design Equations-1

PROPORTIONAL-Integral-Derivative (PID) controllers

Spring 2006 Process Dynamics, Operations, and Control Lesson 5: Operability of Processes

Lecture 8. Mole balance: calculations of microreactors, membrane reactors and unsteady state in tank reactors

Application of Decomposition Methodology to Solve Integrated Process Design and Controller Design Problems for Reactor-Separator-Recycle Systems

Lecture 8. Mole balance: calculations of microreactors, membrane reactors and unsteady state in tank reactors

A First Course on Kinetics and Reaction Engineering Unit 30.Thermal Back-Mixing in a PFR

Recovering from a Gradual Degradation in MPC Performance

Chemical Reaction Engineering - Part 14 - intro to CSTRs Richard K. Herz,

CBE495 LECTURE IV MODEL PREDICTIVE CONTROL

Development of Dynamic Models. Chapter 2. Illustrative Example: A Blending Process

Feedback Control of Linear SISO systems. Process Dynamics and Control

Overview of Control System Design

CHAPTER 19: Single-Loop IMC Control

ChE 6303 Advanced Process Control

Process Control Hardware Fundamentals

Overview of Control System Design

SCALE-UP OF BATCH PROCESSES VIA DECENTRALIZED CONTROL. A. Marchetti, M. Amrhein, B. Chachuat and D. Bonvin

Control Lab. Thermal Plant. Chriss Grimholt

Chapter 1. Lecture 1

Twin-Screw Food Extruder: A Multivariable Case Study for a Process Control Course

Unit 11 - Week 7: Quantitative feedback theory (Part 1/2)

Multiloop Control: Performance Analysis /n-i

INTEGRATION OF DESIGN AND CONTROL FOR ENERGY INTEGRATED DISTILLATION

Plantwide Control of Chemical Processes Prof. Nitin Kaistha Department of Chemical Engineering Indian Institute of Technology, Kanpur

CHE 404 Chemical Reaction Engineering. Chapter 8 Steady-State Nonisothermal Reactor Design

DYNAMIC SIMULATOR-BASED APC DESIGN FOR A NAPHTHA REDISTILLATION COLUMN

The dos and don ts of distillation column control

Dynamics and PID control. Process dynamics

Systems Engineering/Process Control L1

Systems Engineering/Process Control L1

Process design decisions and project economics Dr. V. S. Moholkar Department of chemical engineering Indian Institute of Technology, Guwahati

CHAPTER 2 PROCESS DESCRIPTION

Time scale separation and the link between open-loop and closed-loop dynamics

Chapter 4. Problem SM.7 Ethylbenzene/Styrene Column

(Refer Slide Time: 00:01:30 min)

CBE 142: Chemical Kinetics & Reaction Engineering

Lynkurs Prosessregulering (Crash course process control) Sigurd Skogestad Institutt for kjemisk prosessteknologi Rom K4-211

= 1 τ (C Af C A ) kc A. τ = V q. k = k(t )=k. T0 e E 1. γ = H ρc p. β = (ρc p) c Vρc p. Ua (ρc p ) c. α =

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering 2.04A Systems and Controls Spring 2013

THE DOS AND DON TS OF DISTILLATION COLUMN CONTROL

Analyzing Control Problems and Improving Control Loop Performance

Self-consistent inventory control

Chemical Reaction Engineering Lecture 5

Control Systems I. Lecture 7: Feedback and the Root Locus method. Readings: Guzzella 9.1-3, Emilio Frazzoli

CHAPTER 6 CLOSED LOOP STUDIES

Solutions for Tutorial 5 Dynamic Behavior of Typical Dynamic Systems

Index Accumulation, 53 Accuracy: numerical integration, sensor, 383, Adaptive tuning: expert system, 528 gain scheduling, 518, 529, 709,

(Refer Slide Time: 1:42)

5. Collection and Analysis of. Rate Data

ChE 344 Winter 2013 Final Exam + Solution. Open Course Textbook Only Closed everything else (i.e., Notes, In-Class Problems and Home Problems

University of Utah Electrical & Computer Engineering Department ECE 3510 Lab 9 Inverted Pendulum

Solution to exam in PEF3006 Process Control at Telemark University College

Midterm II. ChE 142 April 11, (Closed Book and notes, two 8.5 x11 sheet of notes is allowed) Printed Name

MULTILOOP CONTROL APPLIED TO INTEGRATOR MIMO. PROCESSES. A Preliminary Study

Consistent inventory control

Chapter 8. Feedback Controllers. Figure 8.1 Schematic diagram for a stirred-tank blending system.

Chapter 7 Control. Part Classical Control. Mobile Robotics - Prof Alonzo Kelly, CMU RI

Lecture 4. Mole balance: calculation of membrane reactors and unsteady state in tank reactors. Analysis of rate data

Input-output Controllability Analysis

ANFIS Gain Scheduled Johnson s Algorithm based State Feedback Control of CSTR

Determining Controller Constants to Satisfy Performance Specifications

Control Introduction. Gustaf Olsson IEA Lund University.

Process Control and Instrumentation Prof. D. Sarkar Department of Chemical Engineering Indian Institute of Technology, Kharagpur

Process Control, 3P4 Assignment 5

Next, make a stoichiometric table for the flow system (see Table 3-4 in Fogler). This table applies to both a PFR and CSTR reactor.

IJSRD - International Journal for Scientific Research & Development Vol. 1, Issue 8, 2013 ISSN (online):

Transcription:

Process plants ( or complex experiments) have many variables that must be controlled. The engineer must. Provide the needed sensors 2. Provide adequate manipulated variables 3. Decide how the CVs and MVs are paired (linked via the control design) Fortunately, most of what we learned about single-loop systems applies, but we need to learn more! v8 F2 F T T3 T4 v3 T5 F3 T6 F4 F5 P v v2 L v5 v7 v6 T7 L T2 T8 Hot Oil T9 Hot Oil F6

Two control approaches are possible Multiloop: Many independent PID controllers Centralized: Method covered in Chapter 23 F T L F T Centralized Controller L

Two control approaches are possible We will concentrate on MULTILOOP Multiloop: Many independent PID controllers E( t) = SP( t) CV ( t) t d CV MV ( t) = Kc E( t) + E t dt Td + I T ( ') ' I dt v FC E( t) = SP( t) CV ( t) t d CV MV ( t) = Kc E( t) + E t dt Td + I T ( ') ' I dt E( t) = SP( t) CV ( t) t d CV MV ( t) = Kc E( t) + E t dt Td + I T ( ') ' I dt TC LC v3 v2

Let s assume (for now) that we have the sensors and valves. How do we ask the right questions in the best order to have a systematic method for pairing multiloop control? v8 F2 F T T3 T4 v3 T5 F3 T6 F4 F5 P v v2 L v5 v7 v6 T7 L T2 T8 Hot Oil T9 Hot Oil F6

Some key questions whose answers help us design a multiloop control system.. IS INTERCTION PRESENT? - If no interaction ll single-loop problems Let s start here to build understanding 2. IS CONTROL POSSIBLE? - Can we control the specified CVs with the available MVs? 3. WHT IS S-S ND DYNMIC BEHVIOR? - Over what range can control keep CVs near the set points?

What is different when we have multiple MVs and CVs? INTERCTION!! Definition: multivariable process has interaction when input (manipulated) variables affect more than one output (controlled) variable. T Does this process have interaction?

How can we determine how much interaction exists? One way - Fundamental modelling F, x F S, x S = v v2 F M, x M F F + x Fundamental (n-l) F S + = F S F x M S = F M x M F' x' M M = F' = (F Fundamental linearized + F' s F S S + F ) 2 ss F ' F + (Fs + F ) 2 ss F ' S

How can we determine how much interaction exists? One way - Fundamental modelling F, x Total flow, F M F S, x S = v v2 Concent, x M F M, x M Sketch the responses of the dependent variables time time v, % open v2, % open time time

How can we determine how much interaction exists? One way - Fundamental modelling F, x Total flow, F M F S, x S = v v2 Concen., x M F M, x M Sketch the responses of the dependent variables time time v, % open v2, % open time time

How can we determine how much interaction exists? Second way - Empirical modelling (process reaction curve) Step change to reflux with constant reboiler.99 Sketch the responses of the dependent variables.4 R x D XD (mol frac).988.986.984.982 XB (mol frac).35.3.25 V.98 2 4 6 8 2 Time (min).35 x 4.2 2 4 6 8 2 Time (min).565 x 4.565 R (mol/min).3.25 V (mol/min).564.564.563 x B.2 2 4 6 8 2 Time (min).563 2 4 6 8 2 Time (min)

How can we determine how much interaction exists? Second way - Empirical modelling (process reaction curve) Step change to reflux with constant reboiler.99.4 R x D XD (mol frac).986.984.982 XB (mol frac).3.25.988.35.98 2 4 6 8 2.2 2 4 6 8 2 V.35 x 4 Time (min).565 x 4 Time (min).565 R (mol/min).3.25 V (mol/min).564.564.563 x B.2 2 4 6 8 2 Time (min).563 2 4 6 8 2 Time (min)

How can we determine how much interaction exists? Second way - Empirical modelling (process reaction curve) ) (.. ) (.. ) ( ) (. ) (. ) (. s F s e s F s e s x s F s e s F s e s x V s R s B V s R s D 2 253 7 73 5 667 2 747 2 3 3 2 3 + + = + + = F R F V x B x D Which models can be determine from the experiment shown in the previous slide?

How can we determine how much interaction exists? Use the model; if model can be arranged so that it has a diagonal form, no interaction exists. CV... CV n = K K 22 K nn MV MV MV 2 3 If any off-diagonal are non-zero, interaction exists.

How can we determine how much interaction exists? Let s use qualitative understanding to answer the question. Feed has C v Does this CSTR reactor process have interaction? T LC Information:. Exothermic reaction v2 2. -r = k e -E/RT C cooling

How can we determine how much interaction exists? Let s use qualitative understanding to answer the question. Feed has C v T LC From the cause-effect analysis, v affects both sensors; interaction exists! cooling v2 What about v2? v feed flow rate residence time conversion heat generated T v2 coolant flow heat transfer Q/(FρC P ) T conversion nalyzer

We will use a block diagram to represent the dynamics of a 2x2 process, which involves multivariable control. MV G + + CV The blocks (G) cannot be found in the process. They are the models that represent the behavior between one input and one output. G 2 G 2 G d G d2 D MV 2 G 22 + + CV 2

Let s relate the block diagram to a typical physical process. What are the MVs, CVs, and a disturbance, D? F R F R G + + XD F XF q XD F D G 2 G 2 G d G d2 XF F V FRB F RB G 22 + + XB XB FB

Let s relate the block diagram to a typical physical process. What are the MVs, CVs, and a disturbance, D? Reactor v Better control level! G + + T LC G 2 G d G 2 G d2 v2 G 22 + +

Let s relate the block diagram to a typical physical process. What are the MVs, CVs, and a disturbance, D? Reactor v Better control level! v G + + T LC G 2 G d G 2 G d2 v2 v2 G 22 + + T Disturbances = feed composition, feed temperature, coolant temperature,

Some key questions whose answers help us design a multiloop control system.. IS INTERCTION PRESENT? - If no interaction ll single-loop problems 2. IS CONTROL POSSIBLE? - How many degrees of freedom exist? - Can we control CVs with MVs? Let s learn how to answer this key question 3. WHT IS S-S ND DYNMIC BEHVIOR? - Over what range can control keep CVs near the set points?

DEGREES OF FREEDOM How do we determine the maximum # variables that be controlled in a process? v8 F2 F T T3 T4 v3 T5 F3 T6 F4 F5 P v v2 L v5 v7 v6 T7 L T2 T8 Hot Oil T9 Hot Oil F6

DEGREES OF FREEDOM requirement for a successful design is: The number of valves number of CV to be controlled v8 F2 F T T3 T4 v3 T5 F3 T6 F4 F5 P v v2 L v5 v7 v6 T7 L T2 T8 Hot Oil T9 Hot Oil F6 OK, but this does not ensure that we can control the CVs that we want to control!

CONTROLLBILITY system is controllable if its CVs can be maintained at their set points, in the steady-state, in spite of disturbances entering the system. Model for 2x2 system CV CV 2 = = K K 2 K K 2 22 MV MV 2 + K K d d 2 D system is controllable when the matrix of process gains can be inverted, i.e., when the determinant of K. I am in desperate need of examples

Let s do the toy autos first; then, do some processes For the autos in the figure re they independently controllable? Does interaction exist?

For the autos in the figure re they independently controllable? Does interaction exist? Connected by spring

For the autos in the figure re they independently controllable? Does interaction exist? Connected by beam

For process Example #: the blending process re the CVs independently controllable? Does interaction exist? F, x F S, x S = F M, x M F' x' M M = F' = (F + F' s F S S + F ) 2 ss F ' + F (Fs + F ) 2 ss F ' S

For process Example #: the blending process re the CVs independently controllable? Does interaction exist? F, x F S, x S = F M, x M F' x' M M = F' = (F + F' s F S S + F ) 2 ss F ' + F (Fs + F ) 2 ss F ' S Det(K) = (F F 2 + F S ) 2 (F F 2 S + F S ) 2 Yes, this system is controllable!

F R x D For process Example #2: the distillation tower re the CVs independently controllable? Does interaction exist? F V x x D B ( s) = ( s) =. 747e 2s + 3s 3. 3s. 73e. 7s + F R F ( s) R ( s). 667e 5s + 2s 2s. 253e. 2s + F V F ( s) V ( s) x B

For process Example #2: the distillation tower x D x D ( s) =. 747e 2s + 3s F R ( s). 667e 5s + 2s F V ( s) F R x B ( s) = 3. 3s. 73e. 7s + F R ( s) 2s. 253e. 2s + F V ( s) F V Det (K) =.54 x -3 Small but not zero (each gain is small) The system is controllable! x B

For process Example #3: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? B -r = k e -E/RT C G + + v G 2 G d T G 2 G d2 C B v2 G 22 + +

For process Example #3: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? B -r = k e -E/RT C v T The interaction can be strong In general, the temperature and conversion (extent of reaction) can be influenced. The system is controllable. C B v2 (See ppendix 3 for examples)

For process Example #4: the mixing tank re the CVs independently controllable? Does interaction exist? G + + v G 2 G d T G 2 G d2 C G 22 + + v2

For process Example #4: the mixing tank re the CVs independently controllable? Does interaction exist? G + + v G 2 G d T G 2 G d2 C G 22 + + v2 Nothing affects composition at S-S; the system is NOT controllable.

For process Example #5: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? v B -r = k e -E/RT C v2 C B T G G 2 G 2 G 22 + + G d G d2 + +

For process Example #5: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? Solution continued on next slide B -r = k e -E/RT C Both valves have the same effects on both variables; the only difference is the magnitude of the flow change (µ = constant). v v2 T C B T = = K K 2 µ K µ K 2 MV MV 2 C B Det (K) = ; not controllable!

For process Example #5: the non-isothermal CSTR In this case, both MVs affect ONE common variable, and this common variable affects both CVs. We can change both CVs, but we cannot move the CVs to independent values! MV G G + + Input Contraction G d CV D Solution continued on next slide G d2 G MV 2 G 22 + + CV 2

For process Example #5: the non-isothermal CSTR For input contraction, multivariable feedback control is not possible; the system is not controllable! We can change both CVs, but we cannot move the CVs to independent values! SP - + G c Does not work!! MV G + + G d G d2 CV D Solution complete SP 2 + - G c2 MV 2 G 22 + + CV 2

For process Example #6: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? v C B C C B + 2C -r = k e -E/RT C G G 2 G 2 G 22 + + G d G d2 + + v2

For process Example #6: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? B + 2C -r = k e -E/RT C Solution continued on next slide Using the symbol N i for the number of moles of component i that reacts, we have the following. v C B C C v2 N = N N = 2N B Because of the stoichiometry, C N C = 2 N B and the system is not controllable!

For process Example #6: the non-isothermal CSTR re the CVs independently controllable? Does interaction exist? B + 2C -r = k e -E/RT C Solution continued on next slide v C C B C = = K 2K 2 K 2 K 2 MV MV 2 C B C C v2 Det (K) = ; not controllable!

For output contraction, both MVs affect both CVs, but the CVs are related through the physics and chemistry. We can change both CVS, but we cannot move the CVs to independent values! MV G + output contraction + CV G 2 G d D Solution continued on next slide G G d2 MV 2 G 22 + CV 2

In this case, multivariable feedback control is not possible; the system is uncontrollable! SP - + G c Does not work!! MV 2 MV G G 2 + + G d G d2 CV D SP 2 + - G c2 + + CV 2 Solution complete

CONTROLLBILITY Conclusions about determining controllability Lack of controllability when. One CV cannot be affected by any valve This is generally easy to determine. 3. Lack of independent effects. Look for contractions This requires care and process insight or modelling to determine.

Some key questions whose answers help us design a multiloop control system.. IS INTERCTION PRESENT? - If no interaction ll single-loop problems 2. IS CONTROL POSSIBLE? - How many degrees of freedom exist? - Can we control CVs with MVs? Let s see how good the performance can be 3. WHT IS S-S ND DYNMIC BEHVIOR? - Over what range can control keep CVs near the set points?

How does interaction affect the steady-state behavior of the blending process? Please sketch the achievable values Total flow, F3 9 8 7 6 5 4 3 2 F, x F S, x S =...2.33.4.5.6.7.8.9. x M, Composition (fraction ) F maximum = 3 F s maximum = 6 F M, x M

How does interaction affect the steady-state behavior of the blending process? Please explain this shape Total flow, F3 9 8 7 6 5 4 3 feasible F, x F S, x S = infeasible F maximum = 3 F s maximum = 6 Note: F M, x M This shows a range of set points that can be achieved (without disturbances). 2...2.33.4.5.6.7.8.9. Composition (fraction )

STEDY-STTE OPERTING WINDOW Conclusions about the steady-state behavior of a multivariable process. Shape of the Window The operating window is not generally a simple shape, like a rectangle. 2. What influences the size of the Window? The operating window is influenced by process chemistry, equipment capacity, disturbances 3. How does Window relate to Controllability? Process cannot be moved (controlled) outside of the window. If operating window is empty, the system is not controllable. Summarize your conclusions here.

NOW, LET S LOOK T THE DYNMIC BEHVIOR. How many experiments are needed to tune controllers? 2. Which controller should be implemented first? MV G + + CV CV ( s) MV ( s) G 2 G 2 G d G d2 D To tune each controller, we need MV 2 G 22 + + CV 2 CV2( s) MV ( s) 2

3. We have implemented one controller. What do we do now? G + + CV MV G 2 G d D MV 2 G 2 G d2 SP 2 + G c2 - G 22 + + CV 2

4. What if we perform another experiment to learn the dynamics between MV and CV, with controller #2 in automatic? Is the dynamic behavior different from without second controller (G C2 )? What elements does the behavior depend upon? G + + CV MV G 2 G 2 G d G d2 D

4. Is the dynamic behavior different from without second controller (G C2 )? What elements does the behavior depend upon? G + direct path interaction path CV MV G 2 CV MV = G G 2 G + G c2 2 G G 22 c2 MV 2 G 2 The process seen by the controller changes! SP 2 + G c2 - G 22 + + CV 2

In general, the behavior of one loop depends on the interaction and the tuning of the other loop. SP - + G c MV G G 2 + + G d CV Tuning that is stable for each loop might not be stable when both are in operation! SP 2 + - MV 2 G c2 G 2 G 22 G d2 + + D CV 2 We need to tune loops iteratively, until we obtain good performance for all loops! I think that I need an example again!

In general, the behavior of one loop depends on the interaction and the tuning of the other loop. Let s look at a simple example with interaction, + + + + = MV MV s e. s e. s e. s e. CV CV s. s. s. s. 2 2 2 2 75 2 75 2 We will pair the loops on the strongest gains, MV CV and MV 2 CV 2

Results with only one controller in automatic (K C = 2., T I = 3) This system is stable and perhaps a bit too aggressive..5 IE = 2.53 ISE =.5448 IE = 66.45 ISE = 49.8627.8.6 CV.5 Feedback control for SP change CV 2.4.2 Why did this change? 2 4 6 8 2 4 6 8 3 SM = 7.543 SSM = 87.4545 SM = SSM = 2.5 2.5 MV.5 MV 2.5 -.5 2 4 6 8 2-2 4 6 8 2 Time Time

Results with both controllers in automatic (Kc = 2., TI = 3) This system is unstable!! Each was stable by itself!! 5 IE = 25.259 ISE = 426.773 5 IE = 25.3684 ISE = 425.27 5 5 CV CV 2-5 -5 - - -5 2 4 6 8-5 2 4 6 8 2 SM = 854.373 SSM = 667.73 2 SM = 852.3648 SSM = 668.2934 MV MV 2 - - -2 2 4 6 8 2-2 2 4 6 8 2 Time Time

In general, the behavior of one loop depends on the interaction and the tuning of the other loop. SP - + G c MV G G 2 + + G d CV I recall that elements in the denominator affect stability. D MV 2 G 2 G d2 SP 2 + - G c2 G 22 + + CV 2 CV SP = numerator + G G + G G + G G [G G G G c c2 22 c c2 22 2 2 ]

In general, the behavior of one loop depends on the interaction and the tuning of the other loop. 4 Single-loop inside the dashed lines would be stable. Notes: Kc2, LOOP 2 CONTROLLER GIN 3 2 Stable for 2x2 Unstable for 2x2.5.5 2 2.5 3 3.5 Kc, LOOP CONTROLLER GIN. TI = 3 for both controllers (reasonable = t63%) 2. KC < 3.75 stable for single-loop feedback 3. KC = 2. stable for one loop 4. KC = 2. unstable for two loops!! 5. These numerical results are for the example only; concepts are general

In general, the behavior of one loop depends on the interaction and the tuning of the other loop. 4 Kc2, LOOP 2 CONTROLLER GIN 3 2 Stable for 2x2 Unstable for 2x2 We can have any values in the stable region. How do we choose the best..5.5 2 2.5 3 3.5 Kc, LOOP CONTROLLER GIN

If both CVs are of equal importance, we would detune both controllers equally. (Kc = Kc2 =.95; TI = TI2 = 3.) IE = 7.224 ISE = 2.85.5 IE = 5.479 ISE =.47 CV.8.6.4.2 Somewhat slow to reach SP CV 2.4.3.2. Interaction affects CV2 2 4 6 8 2 4 6 8 2.5 SM = 2.852 SSM = 8.89 SM =.734 SSM =.2762 2 MV.5 MV 2 -.5 -.5 -.5 2 4 6 8 2 Time -2 2 4 6 8 2 Time

If CV is more important, we would make Gc aggressive and detune Gc2 more. (Kc =.4 and Kc2 =.5; TI = TI2 = 3.) IE = 4.883 ISE =.8496.8 IE =.2283 ISE = 3.23 CV.8.6.4 Fast tracking of the set point CV2.6.4 Increased disturbance from interaction.2.2 2 4 6 8 2 4 6 8 2.5 SM = 4.356 SSM = 4.4664 SM =.763 SSM =.792 2 -.5 MV.5.5 2 4 6 8 2 Time MV 2 - -.5-2 2 4 6 8 2 Time

If CV2 is more important, we would make Gc2 aggressive and detune Gc more. (Kc =.5 and Kc2 =.4; TI = TI2 = 3.) IE = 3.6475 ISE = 5.9352.4 IE = 3.653 ISE =.3957 CV.8.6.4.2 Very slow to reach the SP CV 2.3.2. Reduced disturbance due to interaction 2 4 6 8 2 4 6 8 2.5 SM = 2.2765 SSM = 5.278 SM =.763 SSM =.792 2 -.5.5 MV MV 2 -.5 -.5 2 4 6 8 2-2 2 4 6 8 2 Time Time

In general, the behavior of one loop depends on the interaction and the tuning of the other loop. Some conclusions for multiloop PID tuning:. For multiloop, we generally have to tune the controllers in a less aggressive manner than for single-loop. 2. Textbook gives tuning approach, (Kc) ml /2 (Kc) sl 3. We can tune important loop tightly, if we also detune (make less aggressive) other loops.

Summary of key questions for multiloop control system. IS INTERCTION PRESENT? - No interaction ll single-loop problems - We use models to determine interaction Fundamental or empirical 2. IS CONTROL POSSIBLE? 3. WHT IS S-S ND DYNMIC BEHVIOR?

Summary of key questions for multiloop control system. IS INTERCTION PRESENT? 2. IS CONTROL POSSIBLE? - DOF: The # of valves # of controlled variables - Controllable: Independently affect every CV Check if det [K] Look for contractions 3. WHT IS S-S ND DYNMIC BEHVIOR?

Summary of key questions for multiloop control system. IS INTERCTION PRESENT? 2. IS CONTROL POSSIBLE? 3. WHT IS S-S ND DYNMIC BEHVIOR? - The operating window is: strongly affected by interaction strongly affected by equipment capacities not a rectangle or symmetric

Summary of key questions for multiloop control system. IS INTERCTION PRESENT? 2. IS CONTROL POSSIBLE? 3. WHT IS S-S ND DYNMIC BEHVIOR? - Interaction affects loop stability - We have to detune to retain stability margin - We can improve some loops by tight tuning, but we have to detune and degrade other loops

Workshop in Interaction in Multivariable Control Systems

Workshop Problem # You have been asked to evaluate the control design in the figure. Discuss good and poor aspects and decide whether you would recommend the design.

Workshop Problem # 2 We need to control the mixing tank effluent temperature and concentration. F T C F 2 T 2 C 2 You have been asked to evaluate the design in the figure. Discuss good and poor aspects and decide whether you would recommend the design. T

Workshop Problem # 3 Summarize the underlying principles that can lead to a contraction and to a loss of controllability. These principles will be applicable to many process examples, although the specific variables could be different. Hint: Review the examples in the lecture and identify the root cause for each.