Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

Similar documents
1. Ion exchange chromatography

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Hints for Strong Ion Exchange Resins

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Toxicology Extraction Procedure for Base Drugs Using United Chemical Technologies Clean Screen Extraction Columns

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Egualen Sodium Granules

Analytical Grade AG 11 A8 Ion Retardation Resin Instruction Manual. Catalog Number

Place a collection tube beneath cartridge. 3 ml methylene chloride/isopropyl alcohol/ hydrochloric acid (60/40/1) Collect the eluant

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

ProPac WCX-10 Columns

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Analysis - HPLC A.136. Primesep 5 µm columns B.136

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

[ Care and Use Manual ]

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

Ondansetron Hydrochloride Tablets

enable measurement. This method separates these isotopes effectively.

Micro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions

THORIUM, PLUTONIUM, AND URANIUM IN WATER

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Determination of trace anions in concentrated hydrofluoric acid

Liquid Chromatography

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

ION CHROMATOGRAPHY SYSTEM S 150

For purification/separation of organic and aqueous phases from a two phase mixture within a 96 or 24 array tube system

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

LUMEFANTRINUM LUMEFANTRINE

Hydrolysis of Salts Weak Acids and Bases

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000


High Performance Liquid Chromatography

Cation Exchange HPLC Columns

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

NORBUPRENORPHINE (Buprenorphine s Metabolite ) BUPRENORPHINE in urine by GC/MS Code GC Method of Confirmation by GC-MS

Sample Preparation Products General Catalogue. Sample Preparation Products General Catalogue

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Dionex IonPac AS28-Fast-4µm column

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

Protein separation and characterization

N6,6 Posidyne Membranes

Chiral Flash Columns

groups I and II cations, amines, divalent transition metals

Bis sulfone Reagents. Figure 1.

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Chromatography. What is Chromatography?

SAL (Salbutamol) ELISA Kit

RediSep Rf C18 Flash Column Loading Techniques

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Shodex TM ODP2 HP series columns

Solid Phase Extraction Method Development Tips and Tricks

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Spectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions

A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

11,12-EET/DHET ELISA kit

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Care and Use Manual for Supelco Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

DATES: LAB: Liquid Chromatography Separation of Grape Kool-Aid

Operating Instructions for Ammonium ISE Specifications

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

Benzoylecgonine in Urine by SAMHSA GC/MS

Hydrogen Peroxide Colorimetric Detection Kit

16 Malachite green 17 Leucomalachite green

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Chromatography. Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing)

Sample Prep Options for GC users

High Performance Liquid Chromatography

This method describes the identification of the following prohibited colorants in cosmetic products:

Determination of Phenoxyacid Herbicides in Water by Solid Phase Extraction and LC-MS/MS Detection

Properties of Compounds

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

Chapter content. Reference

Transcription:

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for ample Preparation -Instruction Manual- Table of Contents ection 1 Introduction...1 ection 2 Column Descriptions...2 ection 3 Instructions For se...3 ection 4 Ion Exchange Capacity...4 ection 5 Flow Rate Characteristics...5 ection 6 Chemical Compatibility....6 ection 7 Temperature Limits...7 ection 8 Troubleshooting...8 ection 9 Ordering Information...9 180 Heartland Blvd, Edgewood, NY 11717 Phone (800) 223-4835 Fax (631) 595-9204 www.biochemicaldiagnostics.com

ection 1 Introduction Prefilled Multi-Prep and Detectabuse columns are polypropylene columns containing non-ionic and ion exchange resins. These columns combine the analytical quality and wide selection of Biochemical Diagnostics resins with the convenience of disposable columns and are especially useful in sample preparation for GC/M and LC/M analysis. Whether its automation or manual sample preparation we have you covered. ROBOTIC MANAL PREPARATION ----------------------------------------------------------------------------------------------------------------------------- -------------- ection 2 Column Descriptions GC/M Grade Extraction Columns: Two different column configurations are currently available, each with the same bed configuration but with different size reservoirs, 15 ml and 3 ml. The 96 deep-well plates are also available with the same beds as are available in the individual columns. This feature enables the operator to interchange between manual and automated methods without varying sample or reagent volumes. The 15 ml reservoir column is available in both amber color to help protect light sensitive compounds, and natural opaque white and may be used manually or with robotic systems. The smaller 3 ml syringe barrel columns and the 96 deep-well plates are compatible with all robotic systems. A variety of packings are available in these columns including non-ionic polymers, mixed bed resins, and ion exchangers and several silica gel based bonded phases. The Detectabuse GV-65 is a rugged gravity flow column, packed with a 100-200 mesh particle size modified copolymer bead, and is of the hydrophobic non-ionic type.. GV-65 is available in a 15 ml reservoir column which is amber to protect compounds sensitive to light, and in two different styles of three ml syringe barrel style columns ideal for manual or robotic applications. The Multi-Prep GV-65C column is a 100-200 mesh particle size gravity flow mixed mode type exhibiting both hydrophobic-non-ionic and cation exchange characteristics. The GV-65C is available in an opaque white column to distinguish it from the GV-65 amber column and in 3 ml syringe barrel columns. The bed volume is identical in both column sizes and may be used interchangeably. LC/M Grade Extraction Columns: The Multi-Prep ltra series of deep-well plates is unique in design and function: The incorporation of a 0.45 or 0.22 micron membrane sandwiched between two 8 micron square filters exposes a large surface area which allows solutions to flow easily. We manufacture the new plates in several ways: A. Without PE resin - ltra hydrophilic 0.45 or 0.22 micron filter membrane. Application: 1. Filtering elution solvent from a separate sample preparation. 2. Dilute and shoot up to 500 microliters of urine or oral fluid.

B. With PE resin Application: A second configuration incorporates a small bed of resin, using either the cation exchange mixed bed (GV-35C),or the strong anion exchange resin (GVA) for sample cleanup and elution all in one. The resin bed capacity is optimized for a sample size of 500 microliters or less. ection 3 Instructions for se A typical non-ionic broad screen PE method using the GV-65 mixed bed resin: PE column/96 well plate conditioning All liquids flow by gravity ( please see extraction methods for individual drug extraction details) 1. Activate GV-35C resin with 1 ml of Methanol. Wait 2 minutes. 2. Wash GV-35C resin twice with 200 µl of 0.25M Phosphate Buffer, ph 9.1. 3. Proceed to ample Extraction within 20 min. of column conditioning. ample extraction All liquids flow by gravity 1. Transfer samples onto preconditioned columns or 96 well plate. 2. Wash with 0.5 ml 0.25M Phosphate Buffer, ph 9.1. 3. Dry the resin by applying positive pressure or, vacuum adjusted to at least 7" Hg for 3-5 minutes. ample elution All liquids flow by gravity 1. Elute into a borosilicate glass tube or 96 well collection plate with 400 µl of Ethyl Acetate:Isopropanol (85:15) and allow to flow through by gravity. 2. Add an additional 400 µl of Ethyl Acetate:Isopropanol (85:15)and allow to flow through by gravity. 3. Following elution the eluate must be completely dried down under Nitrogen or Argon and reconstituted with a diluted solution of methanol compatible with the mobile phase used for LC/M analysis. -------------------------------------------------------------------------------------------------------------------- ection 4 Exchange Characteristics Anion Exchange Resins Multi-Prep GVA Anion Exchange Resins are strong (type 1) ion exchange resins. They use a trimethylbenzylammonium group as the exchange site. They are supplied in the chloride form (with a chloride ion occupying the exchange site). This form is very stable and has an excellent shelf life. Anion Exchange Resin Characteristics Type: strong base anion exchanger Active Group: trimethylbenzylammonium % divinylbenzene: 2%, 4%, or 8% upplied Ionic Form: Cl- Moisture Content: 43% to 48% Volume Change: Cl- to OH- is +20% ph Range: 0 to 14 electivity: Cl-/OH- is about 25 Order of electivity: I > NO3 > Br > Cl > acetate > OH > F Cation Exchange Resins Multi-Prep GV-35C/65C Cation Exchange Resins are of a mixed bed type containing both non-ionic moieties and strong acid (type 50) ion exchange resins. They contain a sulfonic acid active group as the exchange site. They are supplied with a hydrogen ion occupying the exchange site. Cation Exchange Resin Characteristics Type: strong acid cation exchanger Active Group: sulfonic acid upplied Ionic Form: H+ ph Range: 0 to 14 Order of electivity: Ba++ > Rb++ > Ca++ > Mg++ > Be++ > Ag+ > Cs+ > Rb+ > K+ > NH4+ > Na+ > H+ > Li+ ection 5

Flow Rate Characteristics The flow rate of an ion exchange resin is primarily determined by the particle size of the resin. sing gravity flow, the expected flow rate for 100-200 mesh resin (74-149µ) in prefilled Multi-Prep columns is approximately 1-2 ml/minute. The flow rate for 200-400 mesh resin (37-74µ) is approximately 4-6 ml/minute. The Multi-Prep ltra columns and plates with sub-micron filters have a slower flow rate than the GC/M grade resins and flow at approximately 0.5 ml/minute. Positive pressure or vacuum assist may be used to induce faster flow rates but should not exceed 1-2 ml/min. ection 6 Temperature Limits Increases in temperature tend to decrease resin selectivity, and can be used to decrease elution times. Increased temperature also increases exchange kinetics, resulting in sharper resolution. However, some temperature limits must be observed with ion exchange resins. Table 3 Maximum temperature for each resin packing. Resin Packing Temperature ( C) GV-65 resin 80 GV-65C resin 80 GVA resin 80 ection 7 ection 8 Chemical Compatibility Troubleshooting 1.Variation in color (lot-to-lot): ometimes the color of the resin may vary from lot to lot. This will not affect the ion exchange capacity of the resin. Table 2 gives the chemical compatibility 2. nusual odor: Amines will sometimes cleave from anion of prefilled columns. While the column is exchange resin after pro- longed storage. This is not unusual. very resistant, the compatibility of the resin They can be removed easily by rinsing with 2-3 bed volumes of must be considered. methanol. Table 2. 3. Effluent is red: After prolonged storage, sulfonic acid will Chemical Compatibility of column sometimes leach from the strong cation exchange resin, Chemical Compatibility* yielding a red effluent. Wash the resin with water until the color is no longer visible. Acetic acid, 50% 4. The GV-65, 96 Deep-well Microtiter plates, and GVA Acetone Acetonitrile columns are designed to flow freely by gravity. If liquids do not Ammonium hydroxide flow freely there is probably air trapped within the column bed Chloracetic acid or frits. Tapping the column mounting plate onto the vacuum Chromic acid, 50% Diethyl ether Dimethyl formamide L box should initiate flow. Precipitates or sediment poured onto the column can also hinder or block the flow of liquids through the column. Dimethylsulfoxide If you have any questions about using pre- filled columns, call Ethyl alcohol our toll-free technical services number, 1-800-223-4835 (in the Ethylene glycol..), or contact your local representative. Formamide Glacial acetic acid Glycerine Hydrochloric acid, 35% Isobutyl alcohol Isopropyl alcohol Methanol Perchloric acid Phosphoric acid Propylene glycol odium hydroxide, 50% to at. L ( for anions) ulfuric acid, 60% ( for anions) ulfuric acid, 98% rea, 8 M * = atisfactory = nsatisfactory L = Low ection 9 Ordering Information

Catalog # Product Description 14100620 Detectabuse GV-65 Columns, non-ionic, amber color, 15 ml reservoir, Pkg. of 100 14100820 Detectabuse GV-65 Columns, non-ionic, 3 ml yringe Barrel, Pkg. of 100 14101660 Detectabuse GV-65 96 Deep Well Microtiter plate, non-ionic, pkg. 5 14300910 Multi-Prep GV-65C Columns, non-ionic/cation Exchange, Natural, 15 ml reservoir, pkg. 100 14100920 Multi-Prep GV-65C Columns, non-ionic/cation Exchange, 3 ml yringe, pkg. 100 14201360 Multi-Prep GV-65C Deep Well Microtiter Plate, pkg. 5 14400041 Multi-Prep ltra-35c 96 Deep Well Microtiter Plate, with 0.45 micron hydrophilic filter pkg. 5 14200820 Multi-Prep GVA-200 Columns, Amber, 15 ml reservoir, pkg. 100 14101920 Multi-Prep GVA-200 Columns, 3 ml yringe Barrel, pkg. 100 Filter Plates (without resin) 14400033 Multi-Prep ltra 96 Deep Well Microtiter Plate, with 0.45 micron hydrophilic filter, pkg.5 14400031 Multi-Prep ltra 96 Deep Well Microtiter Plate, with 0.25 micron hydrophilic filter, pkg.5 Note: pecial order prefilled are available with the chromatographic material of your choice. A minimum order of 1,000 columns is required for special order. Prices quoted on request. Accessories Catalog # Product Description 14024001 Multi-Prep Microplate flow inducer 14024000 Multi-Prep Crossing Guard for 96 well plate 14020001 Multi-Prep 28 place workstation 14058048 Multi-Prep P/E 48 place workstation 180 Heartland Blvd, Edgewood, NY 11717 Phone (800) 223-4835 Fax (631) 595-9204 www.biochemicaldiagnostics.com