Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design

Similar documents
Intelligent Control of a SPM System Design with Parameter Variations

Contact Force-Controlled SPM System Design with Fuzzy Controller

Characterization of MEMS Devices

Outline. 4 Mechanical Sensors Introduction General Mechanical properties Piezoresistivity Piezoresistive Sensors Capacitive sensors Applications

Foundations of MEMS. Chang Liu. McCormick School of Engineering and Applied Science Northwestern University. International Edition Contributions by

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

Integration both PI and PD Type Fuzzy Controllers for a Scanning Probe Microscope System Design

2.76/2.760 Multiscale Systems Design & Manufacturing

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

Lecture 4 Scanning Probe Microscopy (SPM)

And Manipulation by Scanning Probe Microscope

MEMS Tuning-Fork Gyroscope Mid-Term Report Amanda Bristow Travis Barton Stephen Nary

Instrumentation and Operation

SENSOR DEVICES MECHANICAL SENSORS

Scanning Probe Microscopy. EMSE-515 F. Ernst

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

DESIGN, FABRICATION AND ELECTROMECHANICAL CHARACTERISTICS OF A MEMS BASED MICROMIRROR

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

Technical Report PZT-Silicon Cantilever Benders

Kavli Workshop for Journalists. June 13th, CNF Cleanroom Activities

Introduction to Scanning Probe Microscopy Zhe Fei

672 Advanced Solid State Physics. Scanning Tunneling Microscopy

Introduction to Scanning Probe Microscopy

Scanning Tunneling Microscopy

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2016 C. NGUYEN PROBLEM SET #4

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2009 PROBLEM SET #7. Due (at 7 p.m.): Thursday, Dec. 10, 2009, in the EE C245 HW box in 240 Cory.

There's Plenty of Room at the Bottom

b. The displacement of the mass due to a constant acceleration a is x=

Measurement of hardness, surface potential, and charge distribution with dynamic contact mode electrostatic force microscope

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

General concept and defining characteristics of AFM. Dina Kudasheva Advisor: Prof. Mary K. Cowman

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2014 C. Nguyen PROBLEM SET #4

A vibrating micro-cmm probe for micropart metrology

Design and Simulation of Micro-cantilever

Intermittent-Contact Mode Force Microscopy & Electrostatic Force Microscopy (EFM)

Characterization of MEMS Devices

Electrical Characterization with SPM Application Modules

DESIGN AND FABRICATION OF THE MICRO- ACCELEROMETER USING PIEZOELECTRIC THIN FILMS

1. Narrative Overview Questions

A MEMS nanoplotter with high-density parallel dip-pen nanolithography probe arrays

CHARACTERIZATION of NANOMATERIALS KHP

GENERAL CONTACT AND HYSTERESIS ANALYSIS OF MULTI-DIELECTRIC MEMS DEVICES UNDER THERMAL AND ELECTROSTATIC ACTUATION

Atomic Force Microscopy imaging and beyond

Scanning Probe Microscopy (SPM)

PIEZOELECTRIC TECHNOLOGY PRIMER

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

EE C245 ME C218 Introduction to MEMS Design Fall 2007

Microstructure cantilever beam for current measurement

Finite Element Analysis of Piezoelectric Cantilever

Atomic and molecular interactions. Scanning probe microscopy.

7.Piezoelectric, Accelerometer and Laser Sensors

PERFORMANCE OF HYDROTHERMAL PZT FILM ON HIGH INTENSITY OPERATION

Design And Analysis of Microcantilevers With Various Shapes Using COMSOL Multiphysics Software

Nonlinear Vibration of the Double-Beams Assembly Subjected to A.C. Electrostatic Force

Y. C. Lee. Micro-Scale Engineering I Microelectromechanical Systems (MEMS)

MEMS design and fabrication of an electrostatic vibration-to-electricity energy converter

Vibration Studying of AFM Piezoelectric Microcantilever Subjected to Tip-Nanoparticle Interaction

developed piezoelectric self-excitation and selfdetection mechanism in PZT microcantilevers for dynamic scanning force microscopy in liquid

SENSORS and TRANSDUCERS

Application of electrostatic force microscopy in nanosystem diagnostics

Development and Characterization of High Frequency Bulk Mode Resonators

MCE603: Interfacing and Control of Mechatronic Systems

Ecole Franco-Roumaine : Magnétisme des systèmes nanoscopiques et structures hybrides - Brasov, Modern Analytical Microscopic Tools

INTRODUCTION TO SCA\ \I\G TUNNELING MICROSCOPY

10 Measurement of Acceleration, Vibration and Shock Transducers


Technology Brief 9: Capacitive Sensors

Scanning Tunneling Microscopy

Table of Content. Mechanical Removing Techniques. Ultrasonic Machining (USM) Sputtering and Focused Ion Beam Milling (FIB)

The activities of micro-force measurement below 10 mn in Center for Measurement Standards

CNPEM Laboratório de Ciência de Superfícies

Piezoresistive Sensors

Reduced Order Modeling Enables System Level Simulation of a MEMS Piezoelectric Energy Harvester with a Self-Supplied SSHI-Scheme

The Fluid-Coupled Motion of Micro and Nanoscale Cantilevers

Techniken der Oberflächenphysik (Techniques of Surface Physics)

CHAPTER 5 FIXED GUIDED BEAM ANALYSIS

Introduction to Actuators PK

Design and Optimization of An All Optically Driven Phase Correction MEMS Device using FEA

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

Nanometrology and its role in the development of nanotechnology

MODELING OF T-SHAPED MICROCANTILEVER RESONATORS. Margarita Narducci, Eduard Figueras, Isabel Gràcia, Luis Fonseca, Joaquin Santander, Carles Cané

Design and Analysis of Various Microcantilever Shapes for MEMS Based Sensing

Santosh Devasia Mechanical Eng. Dept., UW

REPORT ON SCANNING TUNNELING MICROSCOPE. Course ME-228 Materials and Structural Property Correlations Course Instructor Prof. M. S.

Self-study problems and questions Processing and Device Technology, FFF110/FYSD13

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2011 C. Nguyen PROBLEM SET #7. Table 1: Gyroscope Modeling Parameters

7. CONCLUSIONS & SCOPE

SUPPLEMENTARY INFORMATION

SCME KIT OVERVIEW. Rainbow Wafer Kit

CAPACITIVE MICRO PRESSURE SENSORS WITH UNDERNEATH READOUT CIRCUIT USING A STANDARD CMOS PROCESS

FEM-SIMULATIONS OF VIBRATIONS AND RESONANCES OF STIFF AFM CANTILEVERS

Program Operacyjny Kapitał Ludzki SCANNING PROBE TECHNIQUES - INTRODUCTION

Four Degrees-of-Freedom Micromachined Gyroscope

EE C245 ME C218 Introduction to MEMS Design

Scanning Force Microscopy

DESIGN AND FABRICATION OF A MICRO ELECTROSTATIC VIBRATION-TO-ELECTRICITY ENERGY CONVERTER

An Energy Circulation Driving Surface Acoustic Wave Motor

Sensor Measurements For Diagnostic Equipment

Transcription:

Tamkang Journal of Science and Engineering, Vol. 12, No. 4, pp. 399 407 (2009) 399 Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design Jium-Ming Lin 1 * and Po-Kuang Chang 2 1 Department of Mechanical Engineering, Chung-Hua University, Hsin-Chu, Taiwan 300, R.O.C. 2 Institute of Science and Engineering, Chung-Hua University, Hsin-Chu, Taiwan 300, R.O.C. Abstract This research integrated a MEMS electrostatic driven micro-probe and a laser Doppler vibrometer for non-contact vibration mode scanning probe microscope system design. The microprobe tip was placed in perpendicular to the sample surface, and the built-in capacitor on the microprobe was excited to vibrate by a sinusoidal drive voltage to generate Coulomb electrostatic force. The applied frequency is right at the structure natural resonant frequency of the microprobe. Then let the sample carried by a Z-stage move up. When the sample gets closer to the microprobe, the Van Der Waal s force between the sample and microprobe would become larger, and the microprobe vibration amplitude would be reduced, and which can be determined by a laser Doppler vibrometer. Since the probe vibration amplitude is proportion to the distance between the probe tip and the sample surface. Thus one can detect the sample surface profile, by moving the probe tip at a constant height, and using a laser Doppler vibrometer to obtain the topography with the amplitudes of microprobe vibration history. The accuracy of the proposed system is about 10 nanometers with a gauge meter. Key Words: Microprobe, Non-Contact Vibration Mode, Scanning Probe Microscope 1. Introduction Micro-Electro-Mechanical-System applies the also called Micro System Technology in Europe. The Nobel Prize winner, Prof. Feymann addressed that there s plenty of room at the bottom in 1959 at American Physics Annual Conference [1], which was the first micro machine concept proposed. Up to right now the MEMS is from academic into industry and yielding many products with great potential, which integrates multi-domain knowledge into a cross-filed technology such as electronics, optics, electricity, mechanics, material, physics, and chemistry. In general, the microprobes are carried out by semiconductor process, the principle is to the measure *Corresponding author. E-mail: JmLin@chu.edu.tw the forces of atomic, Coulomb electrostatic and magnetic systems, or for scanning surface profilers with atomic and nanometer levels. In previous literatures, many kinds of microprobes were fabricated on the fields of demands [2 4]. In this research the microprobe is the key component made by MEMS technology on the silicon surface. Some thin film layers such as silicon nitride, silicon dioxide and metal are deposited on the surface to build a pair of released parallel plates as a capacitor structure for electrostatic force driver. The operation principle of the microprobe is firstly by placing the microprobe tip in perpendicular to the sample surface, and using signal generator to deliver a sinusoidal drive voltage, then the microprobe would vibrate due to the Coulomb electrostatic force generated by the electrodes on the micro-probe [5 11]. The

400 Jium-Ming Lin and Po-Kuang Chang working frequency is right at the longitudinal bending mode natural resonant frequency of the microprobe. Thus this structure is a newly design. In this research, the microprobe was calibrated by a piezo-stage as well as a standard gauge meter. The accuracy of the proposed system is about 10 nanometers. The organization of this paper is as follows: the first section is introduction. The second one is principle of design and operation. The stress and strain analyses are in Section 3. The next are microprobe fabrication result and discussion. Section 5 is the system design and integration. The last part is the conclusion. 2. Operation Principle and Design The principle of operation as shown in Figure 1 is firstly by using signal generator to deliver a sinusoidal drive voltage. The cantilever beam connected to the bottom electrode of the microprobe capacitor would vibrate due to the electrostatic force generated by the electrodes of the microprobe. The working frequency is the longitudinal bending mode natural resonant frequency of the microprobe. Then let the microprobe (carried by a piezostage) moving down, when the sample got closer to the microprobe tip, then the vibration amplitude of the microprobe would be decreased, because the Van Der Waal s force between the sample and microprobe would become larger. Thus one can detect the surface profile of a sample, by moving and holding the tip at a constant height, then the probe vibration amplitude is proportion to the surface profile that can be determined by a laser Doppler vibrometer (SIOS SP-S 120/500), and the topography can be obtained by recording the amplitude of vibration history. In this paper, the microprobe was calibrated by a piezo-stage as well as a standard gauge meter. The result can verify the operation principles of the proposed microprobe and non-contact mode SPM system. The electrostatic microprobe structure was developed by MEMS fabrication technology as shown in Figure 2. The cantilever and the micro-probe are shown in part a. Part b is the built-in capacitor of electrostatic structure to drive the cantilever and the microprobe tip. The mirror on the top surface of the cantilever as shown in part c is applied to reflect the laser beam for probe vibration amplitude and surface profile determination. The fabrication processes are as follows: (1) By oxidation process to build a layer of SiO 2 (10 m) on each side of wafer (with thickness 450 m) in < 100 >. Then using Mask #1 and the photolithography process to reserve the photo resist at the left side, and then etch the right hand side SiO 2. (2) Remove proto resist, with the remaining SiO 2 as protection layer, put the wafer into KOH solution to remove silicon. Since the etching rate in < 100 > is much larger than that in < 111 >, thus one can obtain a region with slant surface in Figure 3(a). (3) Remove SiO 2 layer, and deposit a Ni layer (3 m) on the top surface. Using Mask #1 and photolith- Figure 2. The proposed system is with both electrostatic microprobe and laser Doppler vibrometer. Figure 1. The structure of the proposed system. Figure 3(a). Result of step 2.

Integrating MEMS Electro-Static Driven Micro-Probe 401 ography process to reserve photo resist at the left side, and then etch away the rest Ni layer. Finally, remove the photo resist. (4) Deposit a layer of SiO 2. Using Mask #2 and photolithography process to reserve most of the photo resist except a small hole at the right side, and then etch the SiO 2 layer under the small hole as in Figure 3(b). Finally, remove the photo resist. The remaining SiO 2 region is to protect the underneath silicon. (5) Using KOH solution to etch silicon region without SiO 2 protection, since the etching rate in < 100 > is much larger than that in < 111 >, thus one can obtain a small V-groove region for Si 3 N 4 (microprobe tip) deposition. Finally, remove SiO 2. (6) DepositalayerofSi 3 N 4 (20 m). Using Mask #3 and photolithography process to reserve photo resist at the regions of cantilever and microprobe, then etch the other SiO 2 layer to make main frame of cantilever and micro-probe. Finally, remove photo resist; the result is in Figure 3(c). (7) Deposit a layer of Ni on the top side Si 3 N 4 surface of the probe region. Using Mask #4 and the photolithography process to reserve the photo resist at the top side Si 3 N 4 surface of probe region, then etching all other Ni layer away to make the mirror as shown in Figure 3(d). Finally, remove the photo resist. (8) Deposit a thick layer of photo resist (with thickness 20 m) on the top side surface. Using Mask #5 (negative type) and the photolithography process to remove the photo resist as a via hole through the SiO 2 layer as shown in Figure 3(d). (9) Etch the Si 3 N 4 layer under the via hole, and deposit a layer of Ni, then by using the lift off process to remove photo resist and Ni on which to make the interconnection to the buttom electrode. (10) Deposit thick photo resist (30 m) on top side surface. Using Mask #6 (negative type) and photolithography process to remove the left side photo resist. The result is as in Figure 3(e). (11) Deposit a layer of copper (thickness 20 m not thicker than the previous photo resist 30 m), the copper is used as bottom electrode of electrostatic capacitor driver. Then by lift-off process one can remove the photo resist and the copper to make the Figure 3(d). Result of step 8. Figure 3(b). Result of step 5. Figure 3(c). Result of step 6. Figure 3(e). Result of step 10.

402 Jium-Ming Lin and Po-Kuang Chang bottom electrode as in Figure 3(f). (12) Deposit a layer of SiO2 (thickness 30 mm) as well as a layer of photo resist (40 mm). Using Mask #6 (negative type) and the photolithography process to reserve the right side photo resist to make the upper electrode of the electrostatic capacitor as in Figure 3(g). Deposit a layer of copper (thickness 20 mm) on the top side surface. Then by using lift-off process to remove the photo resist and the copper on which to left the upper electrode. The result is as in Figure 3(g). (13) Using Reactive Ion Etch (RIE) process to remove SiO2 between the electrodes and left only one third for supporting the upper electrode. Using KOH solution to remove substrate silicon then one can obtain the microprobe structure as in Figure 2. Figure 4(a). Side view of probe model. 3. Stress and Strain Analyses By using IntelliSuite software package this section is for the proposed microprobe stress and strain analyses to verify the design concept. Firstly, IntelliSuite 3D Builder module package is applied to set up the probe model, the side view, 3D model and the dimensions are as shown in Figures 4(a), (b) and (c), respectively. Then one can use the other software modules for mechanical and electrostatic performance analyses. The mask in GDS II or DXF format can be obtained by using the IntelliMask module. For mechanical performance analysis, Figure 5 shows the mask layout developed by IntelliMask module. Figure 6 shows the displacement of Figure 4(b). 3D probe model. Figure 4(c). 3D probe model (dimensions all in mm). Figure 3(f). Result of step 11. Figure 3(g). Result of step 12. Figure 5. IntelliMask module is applied for mask layout.

Integrating MEMS Electro-Static Driven Micro-Probe 403 Figure 6. The displacement of the bottom plate with 3 MPa load in the negative y-axis on the microprobe. the bottom plate with 3 MPa load in the negative y-axis on the microprobe. Figure 7 shows the displacement of the bottom plate with 0.3 MPa load in the positive y-axis on the microprobe. Then applying driving voltage to the electrodes, Figure 8 shows the bottom plate displacement. Figure 9 shows the resonant frequency analysis of the microprobe structure. It should be noted that in the simulation boundary conditions of upper plate and the left hand side of capacitor structure are fixed, and the probe longitudinal bending mode resonant frequency is 84962.7 Hz (Mode 1), which is the best condition for practical usage; because the applied voltage can be reduced under this condition, and the sensitivity of profile measurement can also be increased. Figure 10 shows the capacitance analysis with 10 volts applied to the electrodes of the microprobe structure. Figure 7. The displacement of the bottom plate with 0.3 MPa load in the microprobe positive y-axis.

404 Jium-Ming Lin and Po-Kuang Chang Figure 8. The bottom plate displacement with 30 volts applied to the microprobe electrodes. 4. Probe Fabrication and Discussion Figure 11 shows the top views of mask #2 made by NDL (National Nano Device Lab) (left) and the result of V-groove (right) after silicon etching process of Step 5 in our MEMS Lab. Figure 12 shows the V-groove profile after Step 5. Figure 13 shows the near views of the canti- Figure 9. Probe structure resonant frequency analyses. Figure 11. The top views of mask #2 (left) and the result of V-groove (right) after silicon etching process of Step 5. Figure 10. The capacitance analysis with 10 volts applied to the microprobe electrodes. Figure 12. The profile of the V-groove after Step 5.

Integrating MEMS Electro-Static Driven Micro-Probe 405 Figure 13. Near views of cantilever (left) and probe tip (right). lever (left) and the probe tip (right). It should be noted that the operation principle of this SPM system is noncontact mode, thus the radius of probe tip is not so critical. However, one can sharpen it to nanometers by laser ablation to increase the sensitivity. 5. Integrated SPM System Design Figure 14 shows the structure of integrated SPM system, which includes electrostatic micro probe, laser Doppler vibrometer, XY-stages, piezo (Z)-stages, signal generator, PC, and with programming firmware for system operation. The system operation principle is firstly by placing the microprobe tip in perpendicular to the sample surface, and using signal generator to deliver a sinusoidal drive voltage, and then the microprobe would vibrate due to the Coulomb electrostatic force generated by the electrodes on the microprobe. The practical working frequency is some what lower (10%) than the simulated one. This is due to the process deviations. Then let the sample carried by a Z-stage move up. When the sample gets closer to the microprobe tip, then the vibration amplitude of the microprobe tip would be reduced and which can be determined by a laser Doppler vibrometer, because the Van Der Waal s force between the sample and micro-probe tip would become larger. Thus one can detect the surface profile of the sample, by moving and holding the tip at a constant height, and then the probe vibration amplitude is proportion to the surface profile that can be determined by a laser Doppler vibrometer (SIOS SP-S 120/500, the accuracy is 0.3 nm), and the topography can be obtained by recording the amplitude of vibration history. In this section the microprobe tip displacement and vibration amplitude was calibrated by a piezostage, the result is in Figure 15. Then the measurement of a sample was made and compared with that obtained by a commercial surface profiler, the results are respectively shown in Figures 16 and 17, which can verify not only the concept and the re- Figure 15. The piezo-stage calibration result of probe tip displacement and vibration amplitude. Figure 14. The structure of the integrated SPM system. Figure 16. The surface profile of a gauge meter obtained with a commercial SPM system (ET-4000).

406 Jium-Ming Lin and Po-Kuang Chang 6. Conclusion Figure 17. The surface profile of a gauge meter obtained by the proposed system. alization of the proposed microprobe, but also the operation principle of the non-contact mode SPM system. The accuracy of the proposed system is about 10 nanometers. The vibrometer time domain result for the surface profile measurement is shown in Figure 18. This research proposed a non-contact mode SPM system design by integrating MEMS electrostatic microprobe and laser Doppler interferometer to develop a high precision measurement system. In this paper we had shown the operation principle to detect the surface profile of the sample by moving and holding the micro-probe tip at a constant height, and the topography can be obtained by recording the amplitude of vibration history. In this research, we used a piezo-stage and a gauge meter to calibrate the micro-probe; the accuracy of the proposed system is about 10 nanometers with a gauge meter. Thus we had verified the structure and the operation principle of the proposed electrostatic driven microprobe as well as non-contact mode SPM system. Figure 18. The vibrometer time domain result for the surface profile measurement.

Integrating MEMS Electro-Static Driven Micro-Probe 407 Acknowledgement This research was supported by Chung-Hua University with the grant no: CHU 94-TR-06 and National Science Council with the grant no s NSC-95-2221-E-216-012- and 96-2221-E-216-029-. References [1] Feynman, R. P. There s Plenty of Room at the Bottom, American Physics Annual Conference (1959), also appeared at Caltech s Engineering and Science, February (1960). [2] Binnig, G., Roher, H., Gerber, H. and Weibel, E. Surface Studied by Scanning Tunneling Microscopy, Physical Review Letters, Vol. 49, pp. 57 61 (1982). [3] Neubauer, G., Force Microscopy with a Bidirectional Capacitor Sensor, Rev. Science Instrument, Vol. 61, pp. 2296 2308 (1990). [4] Binnig, G., Quate, C. F. and Gerber, C. H., Atomic Force Microscope, Physical Review Letters, Vol. 56, pp. 930 933 (1986). [5] Fung, R. F. and Huang, S. C., Dynamic Modeling and Vibration Analysis of the Atomic Force Microscope, ASME, Journal of Vibration and Acoustics, Vol. 123, pp. 502 509 (2001). [6] Seeger, J. I. and Crary, S. B., Stabilization of Electro- Statistically Actuated Mechanical Devices, Transducers 97, Chicago, IL, p. 1133 (1997). [7] Lee, S. Y. and Lin, S. M., Exact Solutions for the Rations of an Elastically Restrained Non-Uniform Timoshenko Beam with Tip Mass, AIAA Journal, Vol. 30, pp. 2930 2934 (1992). [8] Holscher, H., Schwarz, U. D. and Wiesendanger, R., Calculation of the Frequency Shift in Dynamic Force Microscopy, Applied Surface Science, Vol. 140, pp. 344 351 (1999). [9] Sasaki, N., Tsukada, M., Tamura, R., Abe, K. and Sato, N., Dynamics of the Cantilever in Non-Contact Atomic Force Microscopy, Applied physics A: Materials, Vol. 66, pp. 287 291 (1998). [10] Rabe, U., Janser, K. and Amold, W., Vibrations of Free and Surface-Coupled Force Microscope Cantilevers: Theory and Experiment, American Institute of Physics, Vol. 67, pp. 3281 3293 (1996). [11] Fung, R. F. and Huang, S. C., Dynamic Modeling and Vibration Analysis of the Atomic Force Microscope, ASME, Journal of Vibration and Acoustics, Vol. 123, pp. 502 509 (2001). Manuscript Received: Jan. 28, 2008 Accepted: Dec. 24, 2008