Ionization Detectors

Similar documents
Ionization Detectors. Mostly Gaseous Detectors

Generic Detector. Layers of Detector Systems around Collision Point

Resolution. σ z. = σ z. If D(z) is gaussian the relation between FWHM and standard deviation is. = Δz 2.36

3. Gas Detectors General introduction

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

Lecture 4. Detectors for Ionizing Particles

EEE4106Z Radiation Interactions & Detection

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Proportional Counters

GEM: A new concept for electron amplification in gas detectors

Nuclear Physics and Astrophysics

Chap. 5 Ion Chambers the electroscope

PHYS 3446 Lecture #12

General Overview of Gas Filled Detectors

Particle Energy Loss in Matter

The outline. 1) Detector parameters: efficiency, geometrical acceptance, dead-time, resolution, linearity. 2) gaseous ionization chambers

Chapter 3 Gas Filled Detectors

Dr. Nidal M. Ershaidat Dr. Nidal M. Ershaidat - Nuclear Techniques - Chapter 5: Gas-Filled Detectors 2

Particle Energy Loss in Matter

Part II. Momentum Measurement in B Field. Contribution from Multiple Scattering. Relative Momentum Error

Signals in Particle Detectors (1/2?)

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

Lecture 6: High Voltage Gas Switches

Radioactivity. PC1144 Physics IV. 1 Objectives. 2 Equipment List. 3 Theory

Absorption and Backscattering ofβrays

General Information. Today s Agenda. Review Photon Interactions with Matter Gaseous Ionization Detectors

Carriers Concentration and Current in Semiconductors

Week 5: Chap. 5 Ion Chambers

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Particle Detectors. History of Instrumentation History of Particle Physics. The Real World of Particles. Interaction of Particles with Matter

Experimental Particle Physics

Detectors for High-Energy (Heavy-Ion) Experiments

Tracking detectors for the LHC. Peter Kluit (NIKHEF)

Radionuclide Imaging MII Detection of Nuclear Emission

Experimental Particle Physics

Momentum Measurement in B Field. Part II. Relative Momentum Error. Contribution from Multiple Scattering

Seminar talks. Overall description of CLAS12 (Jefferson Lab) MAPS. Talks on Feb. 6 th, (Contact JR) (Contact TS)

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

Experimental Particle Physics

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Chapiter VII: Ionization chamber

Contents. 2. Fluids. 1. Introduction

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Introduction. Principle of Operation

RPCs and applications to the Particle Physics

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

Absorption and Backscattering of β-rays

08 - Miscellaneous and historical detectors

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. II - Particle Detectors - Tsipenyuk Yu.M.

Effect of Applied Electric Field and Pressure on the Electron Avalanche Growth

Lecture 18. New gas detectors Solid state trackers

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

R&D on Astroparticles Detectors. (Activity on CSN )

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Matti Laan Gas Discharge Laboratory University of Tartu ESTONIA

Supplementary Information

Bethe-Block. Stopping power of positive muons in copper vs βγ = p/mc. The slight dependence on M at highest energies through T max

Momentum measurement. Multiple scattering Bethe-Bloch formula / Landau tails Ionization of gases Wire chambers. Drift and diffusion in gases

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

THE GEIGER-MULLER TUBE AND THE STATISTICS OF RADIOACTIVITY

DETECTORS. I. Charged Particle Detectors

Effect of small amounts of hydrogen added to argon glow discharges: Hybrid Monte Carlo fluid model

Performance of a triple-gem detector for high-rate particle triggering

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Chapter 4 Scintillation Detectors

ELECTROMAGNETIC WAVES

Two-phase and gaseous cryogenic avalanche detectors based on GEMs

Detector Physics of Resistive Plate Chambers

PLK VICWOOD K.T. CHONG SIXTH FORM COLLEGE Form Seven AL Physics Radioactivity

Combinatorial RF Magnetron Sputtering for Rapid Materials Discovery: Methodology and Applications

Lecture 15: Optoelectronic devices: Introduction

Particle Detectors Tools of High Energy and Nuclear Physics Detection of Individual Elementary Particles

Gas Electron Multiplier detectors with high reliability and stability. Abstract. Introduction

PHY492: Nuclear & Particle Physics. Lecture 24. Exam 2 Particle Detectors

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

A proposal to study gas gain fluctuations in Micromegas detectors

Scintillators General Characteristics

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Laser Types Two main types depending on time operation Continuous Wave (CW) Pulsed operation Pulsed is easier, CW more useful

Collisional radiative model

Relative Momentum Error. Momentum Measurement in B Field. Contribution from Multiple Scattering. First Track Detectors

Physics (Theory) There are 30 questions in total. Question Nos. 1 to 8 are very short answer type questions and carry one mark each.

Research Article Analytic Approximation of Energy Resolution in Cascaded Gaseous Detectors

Theory of Gas Discharge

Microscopic Simulation of GEM Signals

Single Photon detectors

E. K. A. ADVANCED PHYSICS LABORATORY STATISTICS OF COUNTING WITH A GEIGER COUNTER ARTIFICIAL RADIOACTIVITY

MICROMEGAS PERFORMANCE BASED IN ARGON- ISOBUTANE AND ARGON-DEMETHYL-ETHER

Alpha-particle Stopping Powers in Air and Argon

Monte Carlo Collisions in Particle in Cell simulations

Queen s University PHYS 352

Photoelectric Effect Experiment

Total probability for reaction Yield

Gamma and X-Ray Detection

Properties of Muon Drift Tubes

arxiv:physics/ v2 27 Mar 2001

is the minimum stopping potential for which the current between the plates reduces to zero.

What Makes a Laser Light Amplification by Stimulated Emission of Radiation Main Requirements of the Laser Laser Gain Medium (provides the light

Transcription:

Ionization Detectors Basic operation Charged particle passes through a gas (argon, air, ) and ionizes it Electrons and ions are collected by the detector anode and cathode Often there is secondary ionization producing amplification 1

Ionization Detectors Modes of operation Ionization mode Full charge collection but no amplification (gain1) Generally used for gamma exposure and large fluxes Proportional mode Ionization avalanche produces an amplified signal proportional to the original ionization (gain 10 3 10 5 ) Allows measurement of de/dx Limited proportional (streamer) mode Secondary avalanches from strong photo-emission and space charge effects occur (gain 10 10 ) Geiger-Muller mode Massive photo-emission results in many avalanches along the wire resulting in a saturated signal 2

Ionization Detectors 3

Ionization Ionization Direct p + X -> p + X + + e - Penning effect - Ne * + Ar -> Ne + Ar + + e - n total n primary + n secondary 4

n Ionization The number of primary e/ion pairs is Poisson distributed, being due to a small number of independent interactions ε 1 P n primary ( 0; ν ) for 1mm 1 e Ar 2. 5 gives ε Total number of ions formed is total roughly, n de Δx dx, W W i total i is 2 4 n primary n primary 0.92 the effective ave.energy to make an ion pair 5

Ionization air 33.97 6

p Ionization ( 80 : 20) For mixtures, e.g. Ar CO2 2440 3010 nt 0.8 + 0.2 93/ cm 26 33 n 0.8 29.4 + 0.2 34 30 / cm 7

Charge Transfer and Recombination Once ions and electrons are produced they undergo collisions as they diffuse/drift These collisions can lead to recombination thus lessening the signal 8

Diffusion Random thermal motion causes the electrons and ions to move away from their point of creation (diffusion) From kinetic theory 3 ε kt ~ 0.04eV at room temperature 2 Maxwell distribution gives v v 8kT πm v( electrons) ~ 10 4 ( ions) ~ 10 cm / s 6 cm / s 9

Diffusion Multiple collisions with gas atoms causes diffusion The linear distribution of charges is Gaussian 10

Drift In the presence of an electric field E the electrons/ions are accelerated along the field lines towards the anode/cathode Collisions with other gas atoms limits the maximum average (drift) velocity w 11

Drift A useful concept is mobility μ Drift velocity w μe For ions, w + is linearly proportional to E/P (reduced E field) up to very high fields That s because the average energy of the ions doesn t change very much between collisions The ion mobilities are ~ constant at 1-1.5 cm 2 /Vs The drift velocity of ions is small compared to the (randomly oriented) thermal velocity 12

Drift For ions in a gas mixture, a very efficient process of charge transfer takes place where all ions are removed except those with the lower ionization potential Usually occurs in 100-1000 collisions 13

Drift Electrons in an electric field can substantially increase their energy between collisions with gas molecules The drift velocity is given by the Townsend expression (Fma) w τ N μ σ E 1 ( ε )v ee Where τ is the time between collisions, ε is the energy, N is the number of molecules/v and ν is the instantaneous velocity m τ 14

Drift 15

Drift Large range of drift velocities and diffusion constants 16

Drift Note that at high E fields the drift velocity is no longer proportional to E That s where the drift velocity becomes comparable to the thermal velocity Some gases like Ar-CH 4 (90:10) have a saturated drift velocity (i.e. doesn t change with E) This is good for drift chambers where the time of the electrons is measured 17

Drift Ar-CO 2 is a common gas for proportional and drift chambers 18

Drift Electrons can be captured by O 2 in the gas, neutralized by an ion, or absorbed by the walls 19

Proportional Counter Consider a parallel plate ionization chamber of 1 cm thickness V Q C ε 0 Q A / d ~ 100e 10 pf 1 μ V Fine for an x-ray beam of 10 6 photons this is fine But for single particle detectors we need amplification! 20

Proportional Counter C 2πε ln ( b / a) Close to the anode the E field is sufficiently high (some kv/cm) that the electrons gain sufficient energy to further ionize the gas Number of electron-ion pairs exponentially increases 21

Proportional Counter 22

Proportional Counter There are other ways to generate high electric fields These are used in micropattern detectors (MSGC, MICROMEGAS, GEM) which give improved rate capability and position resolution 23

Proportional Counter Multiplication of ionization is described by the first Townsend coefficient α(e) 1 dn nαdx whereα λ n n exp( α E x) M 0 n n exp ( ) () r α(e) is determined by 0 r c a α dr Excitation and ionization electron cross sections in the gas Represents the number of ion pairs produced / path length 24

Proportional Counter Values of first Townsend coefficient 25

Proportional Counter Values of first Townsend coefficient 26

Proportional Counter Electron-molecule collisions are quite complicated 27

Avalanche Formation 28

Signal Development The time development of the signal in a proportional chamber is somewhat different than that in an ionization chamber Multiplication usually takes place at a few wire radii from the anode (rna) The motion of the electrons and ions in the applied field causes a change in the system energy and a capacitively induced signal dv 29

Signal Development Surprisingly, in a proportional counter, the signal due to the positive ions dominates because they move all the way to the cathode du V V V + + >> V CVdV a Na b Na dv dv qedr q CV 0 q CV 0 a Na CV0 / r l2πε b Na CV0 / r l2πε dr dr q ln l2πε q ln l2πε a Na b Na 30

Signal Development Considering only the ions V () t r ( t ) r ( 0) dr μe dt solving for dv dr () r r dr () t q () + μcv0 V t ln 1 t 2 4πεl lπεa q ln l2πε ( t) r a μcv0 1 l2πε r and substituting 31

Signal Development The signal grows quickly so it s not necessary to collect the entire signal ~1/2 the signal is collected in ~1/1000 the time Usually a differentiator is used 32

Signal Development The pulse is thus cut short by the RC differentiating circuit 33

Gas Operationally desire low working voltage and high gain Avalanche multiplication occurs in noble gases at much lower fields than in complex molecules Argon is plentiful and inexpensive But the de-excitation of noble gases is via photon emission with energy greater than metal work function 11.6 ev photon from Ar versus 7.7 ev for Cu This leads to permanent discharge from deexcitation photons or electrons emitted at cathode walls 34

Argon+X Gas X is a polyatomic (quencher) gas CH 4, CO 2, CF 4, isobutane, alcohols, Polyatomic gases have large number of non-radiating excited states that provide for the absorption of photons in a wide energy range Even a small amount of X can completely change the operation of the chamber Recall we stated that there exists a very efficient ion exchange mechanism that quickly removes all ions except those with the lowest ionization potential I 35

Argon+X Gas Neutralization of the ions at the cathode can occur by dissociation or polymerization Must flow gas Be aware of possible polymerization on anode or cathode Malter effect Insulator buildup on cathode Positive ion buildup on insulator Electron extraction from cathode Permanent discharge 36

Gas Polymerization on anodes 37