SIMULATION TEST REPORT NCTL E0A0

Similar documents
Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

WINDOW SIMULATION REPORT

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

THERMAL PERFORMANCE TEST REPORT

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC.

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed

CAE 463/524 Building Enclosure Design Fall 2012

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

THERMAL SIMULATION REPORT. TCL2013-Origin-01 Prepared For:

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

Glazing selection for solar design

Laboratory Evaluation Report for: Dielectric Pipe Unions

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Introduction...COMB-2 Design Considerations and Examples...COMB-3

CAE 331/513 Building Science Fall 2016

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material

Winter Night. Thermos 6mm Outdoors # #

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania

SOLAR GEOMETRY (AND RADIATION)

Determination of thermal transmittance of window (test title)

Here Comes the Sun. Rachel Wagner. Duluth Energy Design Conference 26 February

FG 623 Window Wall. Optional Features Integrates with standard Kawneer windows

Guide Specifications Section

ISO INTERNATIONAL STANDARD. Thermal bridges in building construction Linear thermal transmittance Simplified methods and default values

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Windows film to Glass: Numerical simulation software for avoiding thermal stress Abstract 1. Introduction

WITH LOW EMISSIVITY GLASS

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

ISO INTERNATIONAL STANDARD

Investigation of 3-d Heat Transfer Effects in Fenestration Products

17.01 Maxblock Sunshades by Tubelite Description

Aalborg Universitet. Comparative Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2007

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

Potential of Hollow Glass Microspheres (3M Glass Bubbles) for Thermal Insulation Dr. Friedrich Wolff

Control Standard for Handling Chemical Substances in Products, Parts and Materials

Solar Energy Cooking with the Sun

CERTIFICATE OF CALIBRATION

Content. Thermal insulation

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

Stainless Steel Sanitary Products. 3A & BPE Industry Standard Designs Without Brand Name Price. More For Less

Design strategy for Low e windows with effective insulation

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

ic-wg BLCC WGC PACKAGE SPECIFICATION

EMSL Analytical, Inc.

THE IMPLICATION OF ENERGY EFFICIENT BUILDING ENVELOPE DETAILS FOR ICE AND SNOW FORMATION PATTERNS ON BUILDINGS

Chemical Donation Policy. Santa Clara University (SCU) 500 El Camino Real Santa Clara, CA 95053

ic-wg BLCC WGC OPTO ENCODER PACKAGE SPECIFICATION

Reflectec Thermal Fabric & Reflectec Fiberboard

Evidence of Performance Thermal transmittance

JULY, 2016 E.C Architects - Please contact your Kawneer representative for further assistance.

Building Envelope Requirements Overview Page 3-4

NFRC Errata and Addendum Log

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

Effect of Installing a Curved Venetian Blind to the Glass Window on Heat Transmission

Calculating the heat transfer coefficient of frame profiles with internal cavities

BRE Client Report. Calculation of summertime solar shading performance for MicroLouvre. Prepared for: Smartlouvre. BRE Watford, Herts WD25 9XX

Capstone Design: Energy Efficient Windows Triple Pane Window Analysis

Warm surfaces warm edges Insulated glass with thermally improved edge seal

TREES Training for Renovated Energy Efficient Social housing

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Aalborg Universitet. Empirical Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2006

Thermal bridges in building construction Linear thermal transmittance Simplified methods and default values

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

INTERNATIONAL STANDARD

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Introduction to Infrared Thermometry

Description of Benchmark Cases for Window and Shading Performance Calculation

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

ISO INTERNATIONAL STANDARD. Thermal insulation for building equipment and industrial installations Calculation rules

PARTS MANUAL 2 INCH CHIPPER/SHREDDER. SC cc SUBARU

Source Protection Zones. National Dataset User Guide

LED Lighting Facts: Product Submission Guide

Photometric Test Report

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

Transcription:

SIMULATION TEST REPORT NCTL-610-21539-1E0A0 REPORT TO: All Seasons Window & Door System Inc. 1340 Metropolitan Avenue Brooklyn, NY 11237 SIMULATION DATE: 11/20/18 PRODUCT: EU400 Tilt & Turn This report is for certification of a new product line. Page 1 of 26

SIMULATION TEST REPORT Simulation Standards ANSI/NFRC 100-2017 Procedure for Determining Fenestration Product U- factors ANSI/NFRC 200-2017 Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence NFRC 500-2017 Procedure for Determining Fenestration Product Condensation Resistance Values THERM 7 / WINDOW 7 NFRC Simulation Manual (July 2017) NFRC 2010 Technical Interpretations Manual (November 2017) Approved Simulation Center of Glass Window 7.4 Software 2-D Heat Transfer THERM 7.4 Total Product Calculations Window 7.4 Note: All dimensions are in the order (Width x Height) unless otherwise noted. Report Number Model/Series Operator Type NCTL-610-21536-1E0A0 EU400 Tilt & Turn Dual Action Tilt & Turn (DATT) Simulation Size 1200 mm x 1500 mm (47 x 59 ) Frame Type Sash Type Aluminum w/ Thermal Breaks All Members (AT) Aluminum w/ Thermal Breaks All Members (AT) Frame/Sash Material & Finish Painted Aluminum Alloy Frame Option(s) Frame 1 Standard Offering Reinforcement Not Applicable Thermal Break(s) Weather Seal(s) Polyamide (P) Head (3) Ethylene Propylene Diene Monomer (EPDM) gaskets Jamb (3) Ethylene Propylene Diene Monomer (EPDM) gaskets Sill (3) Ethylene Propylene Diene Monomer (EPDM) gaskets Edge of Glass Interior glazed with a painted aluminum alloy glazing bead with an Ethylene Propylene Diene Monomer (EPDM) gasket onto an EPDM gasket while resting on a foam rubber extrusion. Page 2 of 26

All Seasons Window & Door Systems, Inc. NCTL-610-21539-1E0A0 Spacer System(s) Gas Fillings Divider(s) Divider Notes Aluminum spacer system - dual sealed (A1-D) Argon 90% single probe per the client (ARG) Not Applicable Where the space between lite and divider is greater than 3 mm, dividers are not modeled. Solar Heat Gain Coefficient (SHGC) and Visible Light Transmittance (VT) are calculated using default dividers of less than 1 and greater than/ equal to 1. For U-factor, SHGC, and VT calculations the standard default grid pattern of 12 is used, as established by the Window 7 program. Notes, Additional Information, Comments, and Assumptions All simulations use the emissivity from the approved ANSI/NFRC spectral data files with the International Glazing Database (IGDB). For Solar Heat Gain and Visible Light Transmittance; all frame, divider and glass options are grouped using the best case center of glass/ worst-case frame values from the U Factor calculations as required by ANSI/NFRC 200-2017. A default frame absorptance of 0.30 is assumed for all products except glazing window walls, glazing curtain walls, and slopped glazing wall - all of which will have a frame absorptance of 0.50 This report is the joint property of National Certified Testing Laboratories, Inc. (NCTL) and the client to whom it is issued. Permission to reproduce this report by anyone other than NCTL and the Client must be granted in writing by both of the above parties. This report may not be reproduced except in its entirety Supporting information including THERM 7 and WINDOW 7 files are being submitted as part of this report. The simulation matrix is being submitted electronically. Detailed assembly drawings, horizontal and vertical cross-sectional drawings, profile drawings, parts drawings, and a bill of materials as supplied by the client were used as the basis for performing the simulations. Copies are attached to this report. The results were secured by using the designated methods and NFRC approved simulation programs as required by, and in full compliance with, NFRC procedures. This report does not constitute certification of this product. The results in this report apply only to the sample as shown in the attached drawings, using the components and construction methods described herein. NCTL does not warrant the accuracy of the computer programs used to obtain the results. Client request for work performed by NCTL and its associated documentation constitute approval by client for Inspection Agency (IA) submission. Ratings values included in this report are for submittals to an NFRC-licensed IA and are not meant to be used directly for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) by an NFRC accredited Inspection Agency (IA) are to be used for labeling purposes. The Condensation Resistance results obtained from this procedure are for controlled laboratory conditions and do not include the effects of air movement through the specimen, solar radiation and the thermal bridging that may occur due to the specific design and construction of the fenestration system opening. Page 3 of 26

All Seasons Window & Door Systems, Inc. NCTL-610-21539-1E0A0 Units and rounding is in accordance with NFRC 601, Units and Measurement Policy except that all units may be reported in IP as the primary units after conversion and any matrix is reported in IP units only unless requested otherwise by the client. The manufacturer is capable of producing, in its normal manufacturing process, products in sizes identical to the model sizes listed in the ANSI/NFRC 100 Table 4-3 and have a least deviation of 0 within the tolerances of ANSI/NFRC 100. All simulations are performed in the sizes and configurations listed in ANSI/NFRC 100 Table 4-3 except that a non-standard size may be simulated and identified in the matrix to match the manufacturer s physical test sample. Glass and glazing types, Low-E placement, finishes and other required information is included in the NFRC U-Factor Simulation Summary Report and/ or the NFRC SHGC/ VT Simulation Summary Report included in this document. Additional supporting information and modeling assumptions are included in the individual reports obtained from the approved simulation programs and in the notes following the required summary reports. National Certified Testing Laboratories Performed by: Reviewed by: CHRISTOPHER PONDOLFINO NFRC Certified Simulator MARK BENNETT NFRC Certified Simulator Simulator-In-Responsible-Charge Attachments Glazing Matrix Appendix A - Revision Summary Appendix B - Product Drawings Page 4 of 26

All Seasons Window & Door Systems, Inc. NCTL-610-21539-1 Gap Fill 2 Gap Fill 1 Gap 2 Gap 1 Pane Thickness #3 Pane Thickness #2 Pane Thickness #1 Pane ID #3 Pane ID #2 Pane ID #1 Product Number PRODUCT % of Gap Fill 1 % of Gap Fill 2 Emissivity Surface 1 Emissivity Surface 4 Emissivity Surface 3 Emissivity Surface 2 Spacer Tint Emissivity Surface 6 Emissivity Surface 5 U-factor Grid Size Grid Type Condensation Resistance VT NO GRID SHGC GRID>=1" SHGC GRID<1" SHGC NO GRID No Grids 1 5 mm Solarban 70XL 5 mm Comfort Select 73 0.184 0.185 0.856 AIR 0.018 0.148 CL A1-D N 0.34 40 0.20 0.43 VT GRID<1" VT GRID >=1" No Grids 2 5 mm Solarban 70XL 5 mm Comfort Select 73 0.184 0.185 0.856 ARG 90 0.018 0.148 CL A1-D N 0.32 42 0.20 0.43 No Grids 3 5 mm Solarban 70XL 5 mm Clear 0.184 0.184 0.856 AIR 0.018 CL A1-D N 0.39 50 0.21 0.46 No Grids 4 5 mm Solarban 70XL 5 mm Clear 0.184 0.184 0.856 ARG 90 0.018 CL A1-D N 0.36 53 0.21 0.46 No Grids 5 5 mm Solarban 60 5 mm Comfort Select 73 0.184 0.185 0.856 ARG 90 0.035 0.148 CL A1-D N 0.32 42 0.28 0.48 No Grids 6 5 mm Solarban 60 5 mm Comfort Select 73 0.184 0.185 0.856 AIR 0.035 0.148 CL A1-D N 0.34 40 0.28 0.48 No Grids 7 5 mm Solarban 60 5 mm Clear 0.184 0.184 0.856 ARG 90 0.035 CL A1-D N 0.36 52 0.29 0.52 No Grids 8 5 mm Solarban 60 5 mm Clear 0.184 0.184 0.856 AIR 0.035 CL A1-D N 0.40 50 0.30 0.52 No Grids 9 5 mm Clear 5 mm Clear 0.184 0.184 0.856 AIR CL A1-D N 0.51 43 0.54 0.59 No Grids 10 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Clear 0.273 0.129 0.184 0.581 0.581 ARG ARG 90 90 0.035 CL A1-D N 0.29 55 0.28 0.47 No Grids 11 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Solarbronze 0.273 0.129 0.184 0.581 0.581 ARG ARG 90 90 0.035 BZ A1-D N 0.29 55 0.28 0.31 No Grids 12 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Azuria 0.273 0.129 0.184 0.581 0.581 ARG ARG 90 90 0.035 AZ A1-D N 0.29 55 0.28 0.38 No Grids 13 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Solargray 0.273 0.129 0.184 0.581 0.581 ARG ARG 90 90 0.035 GY A1-D N 0.29 55 0.28 0.26 No Grids 14 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Clear Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.543 0.543 AIR AIR CL A1-D N 0.37 55 0.45 0.53 No Grids 15 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 70XL Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.543 0.543 AIR AIR 0.018 CL A1-D N 0.30 55 0.22 0.41 No Grids 16 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 70XL Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.543 0.543 ARG ARG 90 90 0.018 CL A1-D N 0.28 55 0.22 0.41 No Grids 17 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.543 0.543 AIR AIR 0.035 CL A1-D N 0.30 55 0.29 0.47 No Grids 18 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.543 0.543 ARG ARG 90 90 0.035 CL A1-D N 0.28 55 0.28 0.47 No Grids 19 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Clear 0.273 0.129 0.184 0.706 0.706 ARG ARG 90 90 0.035 CL A1-D N 0.29 53 0.29 0.47 No Grids 20 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Solarbronze 0.273 0.129 0.184 0.706 0.706 ARG ARG 90 90 0.035 BZ A1-D N 0.29 53 0.28 0.31 No Grids 21 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Azuria 0.273 0.129 0.184 0.706 0.706 ARG ARG 90 90 0.035 AZ A1-D N 0.29 53 0.28 0.38 No Grids 22 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 5 mm Solargray 0.273 0.129 0.184 0.706 0.706 ARG ARG 90 90 0.035 GY A1-D N 0.29 53 0.28 0.26 No Grids 23 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Clear Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.668 0.668 AIR AIR CL A1-D N 0.36 53 0.45 0.53 No Grids 24 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 70XL Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.668 0.668 AIR AIR 0.018 CL A1-D N 0.30 53 0.22 0.41 No Grids 25 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 70XL Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.668 0.668 ARG ARG 90 90 0.018 CL A1-D N 0.28 53 0.22 0.41 No Grids 26 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.668 0.668 AIR AIR 0.035 CL A1-D N 0.30 53 0.29 0.47 Page 5 of 26

VT GRID >=1" VT GRID<1" All Seasons Window & Door Systems, Inc. NCTL-610-21539-1 VT NO GRID SHGC GRID>=1" SHGC GRID<1" SHGC NO GRID Condensation Resistance U-factor Grid Size Grid Type Spacer Tint Emissivity Surface 6 Emissivity Surface 5 Emissivity Surface 4 Emissivity Surface 3 Emissivity Surface 2 Emissivity Surface 1 % of Gap Fill 2 % of Gap Fill 1 Gap Fill 2 Gap Fill 1 Gap 2 Gap 1 Pane Thickness #3 Pane Thickness #2 Pane Thickness #1 Pane ID #3 Pane ID #2 Pane ID #1 Product Number PRODUCT No Grids 27 Clear-2.7 /.060 PVB / Clear-2.7 3 mm Solarban 60 Clear-2.7 /.060 PVB / Clear-2.7 0.273 0.129 0.273 0.668 0.668 ARG ARG 90 90 0.035 CL A1-D N 0.28 53 0.28 0.47 VALIDATION, No Grids 0 5 mm Solarban 70XL 5 mm Clear 0.184 0.184 0.856 ARG 90 0.018 CL A1-D N 0.37 53 0.21 0.46 Page 6 of 26

Appendix A Revision Summary Identification Date Revision Original Issue 11/20/18 Report to Client and Inspection Agency Page 7 of 26

Appendix B Product Drawings Page 8 of 26

ALL SEASON EU400 Item# Part number Part name Material 1 AB601 EU400 FRAME ALUMIINUM 2 AB003 EU400 SASH ALUMIINUM 3 GB004 EU400 1¼ GLAZING ALUMIINUM 4 EV400-6 GASKET EPDM 5 EV400-4 GASKET EPDM 6 EV400-3 GASKET EPDM 7 EV400-1 GASKET EPDM 8 EV400-2 GASKET FOAM Page 9 of 26

ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Phone: (732)238-7100 Fax : (732)322-4668 Page 10 of 26

1 2 3 7 6 8 4 5 4 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Page 11 of 26 Phone: (732)238-7100 Fax : (732)322-4668

2 1 8 1 1 4 4 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Page 12 of 26 Phone: (732)238-7100 Fax : (732)322-4668

1 7 16 3 7 16 1 7 8 2 11 16 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Page 13 of 26 Phone: (732)238-7100 Fax : (732)322-4668

1 3 16 1 1 8 7 8 1 ALL SEASONS 28 Edgeboro Rd, East Page Brunswick, 14 of 26NJ 08816 Phone: (732)238-7100 Fax : (732)322-4668

Page 15 of 26

Page 16 of 26

3 8 1 8 3 16 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Phone: (732)238-7100 Page Fax 17 : (732)322-4668 of 26

3 4 1 2 1 9 16 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Phone: (732)238-7100 Page Fax 18 : (732)322-4668 of 26

3 8 1 8 3 16 1 3 16 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Phone: (732)238-7100 Page Fax 19 : (732)322-4668 of 26

5 16 1 8 5 8 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Phone: (732)238-7100 Page Fax 20 : (732)322-4668 of 26

5 8 1 3 4 ALL SEASONS 28 Edgeboro Rd, East Brunswick, NJ 08816 Page 21 of 26 Phone: (732)238-7100 Fax : (732)322-4668

Page 22 of 26

Page 23 of 26

ALL SEASON EU400 Item# Part number Part name Material 1 AB601 EU400 FRAME ALUMIINUM 2 AB003 EU400 SASH ALUMIINUM 3 GB004 EU400 1¼ GLAZING ALUMIINUM 4 EV400-6 GASKET EPDM 5 EV400-4 GASKET EPDM 6 EV400-3 GASKET EPDM 7 EV400-1 GASKET EPDM 8 EV400-2 GASKET FOAM Page 9 of 26

Page 24 of 26

Page 25 of 26

Page 26 of 26