vacuum analysis plasma diagnostics surface science gas analysis

Similar documents
Hiden EQP Systems. High Sensistivity Mass and Energy Analyzers for Monitoring, Control and Characterization of Ions, Neutrals and Radicals in Plasma.

High Sensitivity Mass and Energy Analysers for Monitoring, Control and Characterisation of Ions, Neutrals and Radicals in Plasma

Hiden HPR60 Molecular Beam Mass Spectrometer System

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

Hiden EQP Applications

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

SURFACE ENGINEERING MASS SPECTROMETERS FOR THIN FILMS, PLASMA AND SURFACE ENGINEERING

Mass Spectrometer A Comparison of Positive and Negative Ion RGA Methods

SNMS. SNMS Applications. Combined SIMS and SNMS

Plasma Diagnostics Introduction to Langmuir Probes

Pressure & temperature sampling options for Hiden gas analysis systems

Extrel Application Note

THIN FILMS, PLASMA & SURFACE ENGINEERING. Mass Spectrometers. for Thin Films, Plasma & Surface Engineering

RESIDUAL GAS ANALYSIS MASS SPECTROMETERS FOR RESIDUAL GAS ANALYSIS - RGA

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

Extrel is widely respected for the quality of mass spectrometer systems that are

FIB - SIMS. Focussed Ion Beam Secondary Ion Mass Spectrometry.

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Robert A. Meger Richard F. Fernster Martin Lampe W. M. Manheimer NOTICE

Relative Sensitivity RS Measurements of Gases

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

ICP-MS. High Resolution ICP-MS.

CATALYSIS & THERMAL ANALYSIS

A novel sputtering technique: Inductively Coupled Impulse Sputtering (ICIS)

Lecture 8: Mass Spectrometry

6.5 Optical-Coating-Deposition Technologies

Lecture 8: Mass Spectrometry

PERSPECTIVE STABLE ISOTOPE RATIO MS

ETCHING Chapter 10. Mask. Photoresist

INTRODUCTION TO THE HYBRID PLASMA EQUIPMENT MODEL

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Jumbo Cross Beam Ionizer

Thin Films, Plasma and Surface Engineering. In the Press. Plasma Diagnostics for the Researcher. Hiden Applications

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Hiden Analytical Ltd

PERSPECTIVE STABLE ISOTOPE RATIO MS

PRINCIPLES OF PLASMA DISCHARGES AND MATERIALS PROCESSING

ICPMS Doherty Lecture 1

Mass Spectrometry in MCAL

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

Ionization Techniques Part IV

Secondary Ion Mass Spectroscopy (SIMS)

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Catalysis CAPABILITIES

Introduction to the Q Trap LC/MS/MS System

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence

Secondary Ion Mass Spectrometry (SIMS)

The sercon group Isotope Ratio Mass

Plasma Modeling with COMSOL Multiphysics

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

MS Goals and Applications. MS Goals and Applications

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

High power impulse plasmas for thin film deposition

Defining quality standards for the analysis of solid samples

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Previous Lecture. Electron beam lithoghraphy e - Electrons are generated in vacuum. Electron beams propagate in vacuum

Chapter 13: Partial Pressure Analysis

Thin Films, Plasma & Surface Engineering

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Calibration of Particle Instruments in Space Physics

Repetition: Practical Aspects

DPP06 Meeting of The American Physical Society. Production of negative ion plasmas using perfluoromethylcyclohexane (C 7 F 14 )

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Plasma-Surface Interactions in Patterning High-k k Dielectric Materials

Study of DC Cylindrical Magnetron by Langmuir Probe

Secondary ion mass spectrometry (SIMS)

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Chapter 7. Plasma Basics

1. The range of frequencies that a measurement is sensitive to is called the frequency

Etching: Basic Terminology

Adjustment of electron temperature in ECR microwave plasma

TMT4320 Nanomaterials November 10 th, Thin films by physical/chemical methods (From chapter 24 and 25)

Translational Biomarker Core

Chapter 7 Plasma Basic

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Mass Spectrometry. What is Mass Spectrometry?

Etching Capabilities at Harvard CNS. March 2008

RGA modelling and simulation to include pressure dependence in the ion source

Lecture 15: Introduction to mass spectrometry-i

TPRS with MATLAB and quantitative mass spec review. Cassandra Siler

High Resolution Optical Spectroscopy

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Sputter Ion Pump (Ion Pump) By Biswajit

DOE WEB SEMINAR,

RECOMMENDATIONS FOR NOMENCLATURE OF MASS SPECTROMETRY

MS Goals and Applications. MS Goals and Applications

Electrical Discharges Characterization of Planar Sputtering System

Keywords. 1=magnetron sputtering, 2= rotatable cathodes, 3=substrate temperature, 4=anode. Abstract

Effects of cross field diffusion in a low pressure high density oxygen/silane plasma

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Plasma Processing of Large Curved Surfaces for SRF Cavity Modification

This is the total charge on an ion divided by the elementary charge (e).

Plasma parameter evolution in a periodically pulsed ICP

Etching Issues - Anisotropy. Dry Etching. Dry Etching Overview. Etching Issues - Selectivity

Exploration into Sputtered ITO Film Properties as a Function of Magnetic Field Strength

20-22 ISOTOPE RATIO MASS SPECTROMETER

Transcription:

Hiden EQP Systems High Sensitivity Mass and Energy Analysers for Monitoring, Control and Characterisation of Ions, Neutrals and Radicals in Plasma. vacuum analysis surface science gas analysis plasma diagnostics

Hiden EQP Plasma Diagnostic Systems The Hiden EQP System is an advanced plasma diagnostic tool with combined high transmission ion energy analyser and quadrupole mass spectrometer, acquiring both mass spectra at specified ion energies and ion energy distributions of selected plasma ions. The advanced EQP ioniser provides for neutral and radical detection, the electron attachment ionisation feature further enhancing the detection capability for radicals in electronegative plasma chemistries. EQP Operating Modes Ion Energy Distributions of selected +ve and -ve ions. 3.5e+6 3e+6 2.5e+6 2e+6 1.5e+6 Ar + IED Inductively Coupled Plasma Source 25mT 1W High Sensitivity Sub PPM detection of plasma ions, neutrals and radicals. 1e+6 5 Cycle number 1 1 2 3 4 5 6 7 8 9 1 energy: V Ion Energy Analysis Ion Energy distributions of plasma ions are acquired in seconds, 1 ev and 1 ev energy range versions are available. Afterglow, Pulsed Plasma, and Laser Ablation A standard TTL signal gating input is included for time resolved studies. The programmable signal gating option provides for automatic data acquisition for defined time slices through the plasma pulse. Gating resolution is 1 nanoseconds. Positive and Negative Ion Measurement Pre-set software modes enable automatic switching between positive ion, negative ion and neutral analysis modes. Neutral and Radical Detection The EQP integral electron impact ioniser provides for analysis of neutral and radical species. Electron Attachment Ionisation This technique of soft ionisation offered as an option for the analysis of electronegative species in plasma, further enhances the analysis of neutrals and radicals. Appearance Potential Spectra The EQP ioniser features precision control of all ion source parameters, including the facility to accurately scan electron energy for appearance potential spectra of selected species. The appearance potential spectra provide direct information to confirm the fragmentation and excitation state of plasma neutral species. Mass Spectra at selected ion energies for +ve ions, -ve ions and neutrals. Appearance potential spectra for identification of radical species from parent stable molecules. 1 9 8 7 6 5 4 3 2 1 1 9 8 7 6 5 4 3 2 1 2 4 6 8 1 12 14 5 lpm CO2, Plasma Reactor: 1 Torr Appearance Potential: mass 32 4 W plasma metastable O2 excited state a 1 g 1 1.5 11 11.5 12 12.5 13 13.5 14 14.5 15 electron-energy: V no plasma ground state O 2 - X 3 Σ - g Electron attachment ionisation scans to identify radical species produced in the plasma from electronegative gases. CF 3 - Ions By Attachment in CF 4

The HIDEN EQP - The Mass/Energy Analyser for Plasma Diagnostics & Characterisation Plasma Sampling Interface A range of laser drilled orifices from 3µm diameter. The orifice design is optimised for plasma sampling using pre-thinned material for the laser drilled component. Software controlled ion extraction optics provide for plasma sampling with minimum perturbation of the plasma. A standard connection is included in the EQP electronics to allow the EQP system to be referenced to an external supply, a plasma electrode for example. This feature enables ion energy distributions to be referenced to the substrate's self bias. Plasma electrodes coupled to the EQP provide a substrate platform for sampling the plasma as it interacts with the substrate during processing. Electrodes are custom designed to suit RF, DC or pulsed plasma supplies with heated substrate stages and water cooling options available. The EQP sampling configuration can be readily user disassembled for ioniser filament replacement and cleaning. 1 9 8 7 6 5 4 3 2 1 1PPB C + at ~2PPB 7 8 9 1 11 12 13 14 15 16 17 1.6e+8 1.4e+8 1.2e+8 1e+8 8e+7 6e+7 4e+7 2e+7 EQP Sensitivity Internal Ioniser 35 36 37 38 36 4 41 42 43 44 45 Internal Ioniser The internal EQP ioniser includes two oxide coated iridium filaments, with a radially symmetric cage. The assembly is closely coupled to the plasma sampling orifice for high sensitivity analysis of plasma gas neutrals and radicals. EQP software provides for precision control of the ion source operating parameters including filament emission, source cage voltage and the ionising electron energy. A key feature of the EQP ioniser design is the confinement of electrons within the ion cage vicinity. This allows a high degree of control for the detailed appearance potential measurements used in the analysis of radicals. An electron attachment ionisation option is available which allows for analysis of negative ions produced in the EQP ioniser where electronegative species are present. This technique provides valuable information in the analysis of radical species from electronegative plasmas. 45 Sector field energy analyser Ion flight tube to provide plasma sampling insertion from 24mm up to 75mm Turbo molecular pump port Triple filter quadrupole mass analyser 9 8 7 6 5 4 3 2 1 FWHM.24ev Ion counting detector 8.5 8.7 8.9 9.1 9.3 9.5 9.7 9.9 1.1 1.3 1.5 EQP Energy Resolution Energy Analyser The EQP high transmission energy analyser provides ion energy distributions of selected ions within the plasma. For example, the energy with which each species is interacting with the substrate - critical information in low damage etch. A 45 degree sector field energy analyser is used to provide minimum perturbation to the ion flight path within the analyser for optimum energy resolution. The EQP energy analyser provides constant transmission and constant energy resolution functions throughout the ion energy range (+/- 1 ev, +/-1 ev) The energy resolution of the sector field energy analyser is better than.25 ev FWHM. Energy scanning for all ions is automatically controlled with energy increments selectable from.5 ev. The EQP system is floatable to 1 KeV using external power supplies and isolation components. Mass Analyser A triple filter mass analyser construction is included in the EQP system. The triple mass filter has short 'RF only' pre and post filters which minimise effects from fringe fields at the primary mass filter ion entrance and exit. This enhances peak separation and transmission particularly for high mass species. This triple filter configuration has been proven superior in performance to single filter quadrupoles in recent years. Abundance sensitivity is to.1ppm. Detection to 2PPB is available for non-interfering species. The mass filter rods are precision ground from molybdenum with precision machined radially supporting ceramics for high performance, durability and long term stability. Detector An ion counting detector is included as standard offering seven decades continuous dynamic range. Counting is via a 32 bit counter for 1c/sec resolution throughout the range. A Faraday cup option extends the range up to 5 x 1 1 c/s for high density plasma applications. The EQP software provides for data acquisition as raw counts, counts per second, averaged counts per second or integrated counts. Averaging or accumulating counts over repeated mass and energy scans significantly increases signal to noise in the analysis of minor components. A TTL output of raw counts is available via a connector on the EQP electronics system. A signal gating input is included as standard to provide for time resolved plasma studies with a resolution of 1 nanoseconds suited to pulsed plasma or laser ablation applications. The programmable signal gating option provides for automatic data acquisition for a defined time slice through the plasma pulse.

EQP Systems Configurations: EQP 3 3 AMU mass range EQP 5 51 AMU mass range EQP systems include a 6mm pole diameter triple filter quadrupole mass spectrometer. EQP Systems for Plasma Applications Etching Deposition Coating Process Development EQP 1 series Available configured for mass range 5, 3, 51, 1, 25 AMU EQP1 series systems include a 9mm pole diameter triple filter quadrupole mass spectrometer for enhanced abundance sensitivity and high mass range capability. A 2Watt remote RF/DC power supply is included with EQP 1 series systems. Plasma source manufacturing a Light Emitting Diode Hydrogen isotope plasma EQP Systems are offered with a range of standard plasma sampling options to provide a non invasive sampling interface for a broad range of plasma applications including: ECR- Electron Cyclotron Resonance HIPIMS Magnetron Discharge Helicon Source DC Glow Discharge Plasma Pulsed Plasma & Laser Ablation Parallel Plate - RF Plasma ICP- Inductively Coupled Plasma Plasma pressure: up to.5mbar - EQP systems require differential pumping with a 6l/sec turbomolecular pump. up to 2mbar - EQP systems require differential pumping with a 24l/sec turbomolecular pump. > 2mbar - The EQP system is offered with the HPR 6 molecular beam sampling series with multi stage differential pumping. System options include: 1 ev energy range 1 ev energy range is standard. Magnetic shielding standard options include 5 Gauss front end shielding or 8 Gauss complete system shielding. Water cooling for high density plasma applications water cooling is required where the temperature is expected to exceed 3 C. Driven electrode sampling with RF or DC biased electrode - recommended for applications where direct information about plasma interaction with the substrate under substrate bias conditions is a necessity. Plasma needle - atmospheric plasma - analysis with EQP/HPR 6 molecular beam sampling system. Z-drive bellows sealed translator with gate valve to provide for sampling across the plasma volume, and for vacuum isolation of the EQP system. Insertion length options up to 75mm Programmable signal gating recommended for pulsed plasma applications and for systems including molecular beam sampling with chopper. HPR-6 MBMS molecular beam sampling for high pressure plasma. EQP system - in plasma - with cover tube options for SIMS - with driven electrode.

EXAMPLE EQP DATA Plasma etching of Hf-based high k thin films 3 mtorr, 5Watt 5 mtorr, 3Watt QMS-measured plasma ionic species are shown in (a) and (b). Higher mass ionic species measured by QMS are shown in (c) and (d). The data in the left column are taken at 3 mtorr and 5W (high density plasma condition) while those in the right column are taken at 5 mtorr and 3W (low density plasma condition). Data ref: Ryan M. Martin, Jane P. Chang University of California, Los Angeles, USA. J.Vac. Sci. Technol. A 27(2) Magnetron sputtering Positive and negative ion mass spectra Positive Ions. Molybdenum Cathode. Sulphur Hexafluoride Gas. Mass spectrum 9 to 22 amu, showing Molybdenum Fluoride Ions. 16 14 12 Negative Ions. Molybdenum Cathode. Sulphur Hexafluoride Gas. - - - Mass spectrum 14 to 22 amu, showing SF 6, MoF5 and MoF6 Ions. 8 7 6 1 8 6 5 4 3 4 2 2 1 9 1 11 13 15 17 19 21 14 12 14 16 18 2 22 15 17 19 21 16 18 2 22 HIPIMS and conventional sputtering compared mass and energy spectra (a) 2 1M E =.5 ev 3 (b) 1M Ar(1+) E =.5 ev Flux, (x1 6 counts -1 ) 1 Countrate, cs -1 1M 1k 1k 1k Cr(1+) N2(1+) 1 Ar(1+) 1 5 1 Energy, (ev) N 2 + Ar + Cr1+ Flux, (x1 6 counts -1 ) 2 1 Countrate, cs -1 1M 1k 1k 1k N2(1+) Cr(1+) 1 1 5 1 Energy, (ev) N 2 + Ar + N + Cr 2+ N + Cr 2+ Cr 1+ 1 2 3 4 5 6 1 2 3 4 5 6 Mass and energy spectra of (a) HIPIMS of Cr and (b) conventional dc sputtering of Cr in Ar and N 2 atmosphere as used to deposit the CrN/NbN nanolayer coating. Data ref: Purandare, Ehiasarian and Hovsepian. J.Vac. Sci Technol. A 26(2).

Certificate No. 6738 Manufactured in England by: HIDEN ANALYTICAL LTD 42 EUROPA BOULEVARD WARRINGTON, WA5 7UN, ENGLAND Tel: +44 ()1925 445225 Fax: +44 ()1925 416518 Email: info@hiden.co.uk Web Site: www.hidenanalytical.com It is Hiden Analytical s policy to continually improve product performance and therefore specifications are subject to change. TECHNICAL DATA SHEET 172