One-Dimensional Rainbow Technique to Characterize the Evaporation at Ambient Temperature and Evaporation in a Flame of Monodispersed Droplets

Similar documents
Refractive index measurements by Global rainbow refractometry for spherical and non spherical droplets

Determination of the composition of multicomponent droplets by rainbow refractometry

Optical diagnostic techniques for spray systems

Development of the global Rainbow refractometry to measure droplet spray temperature in a large containment vessel

PIV Applications to Thermal Performance of LPG

Digital in-line holography and inverse problems approach for Lagrangian measurements of droplets evaporation

PDA Measurements of Single Point Injection in Cross-flow

GLOBAL RAINBOW REFRACTOMETRY FOR DROPLETS TEMPERATURE MEASUREMENT

The objective of this paper is to present recent advances at Onera in the spray

Three-color LIF thermometry applied to the mixing of two non-isothermal sprays

Quantitative Measurement of planar Droplet Sauter Mean Diameter in sprays using Planar Droplet Sizing

Measurement of novel micro bulk defects in semiconductive materials based on Mie scatter

Droplet sizing and infrared temperature measurements in superheated sprays

Visualization of high-speed gas jets and their airblast sprays of cross-injected liquid

ULTRASONIC ATOMIZATION SPRAY ANALYSIS WITH A THREE-PARAMETER GENERALIZED GAMMA FUNCTION

Digital Holographic Measurement of Nanometric Optical Excitation on Soft Matter by Optical Pressure and Photothermal Interactions

DROP SIZE MEASUREMENT TECHNIQUES APPLIED TO GASOLINE SPRAYS

Erratum to: High speed mixture fraction and temperature imaging of pulsed, turbulent fuel jets auto igniting in high temperature, vitiated co flows

5. 3P PIV Measurements

Density Field Measurement by Digital Laser Speckle Photography

Simultaneous Velocity and Concentration Measurements of a Turbulent Jet Mixing Flow

SIMULTANEOUS VELOCITY AND CONCENTRATION MEASUREMENTS OF A TURBULENT JET MIXING FLOW

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

APPLICATION OF SHADOW DOPPLER VELOCIMETRY TO ARBITRARY-SHAPED DROPLET MEASUREMENT IN WATER SPRAY

OPTIMAL WAVELENGTH SELECTION ALGORITHM OF NON-SPHERICAL PARTICLE SIZE DISTRIBUTION BASED ON THE LIGHT EXTINCTION DATA

Inhomogeneous Mixing Behavior of Recirculated Exhaust Gas in a Lean Premixed Flame

Electric Field Measurements in Atmospheric Pressure Electric Discharges

Lecture 9 Laminar Diffusion Flame Configurations

A New Monodisperse Droplet Generator and its Applications

Physics 1302, Exam 3 Review

Numerical modelling of liquid jets atomisation due to leakage of liquefied gas storage. Saint-Etienne-du-Rouvray Cedex, France

Instantaneous Measurement of Local Concentration and Vapor Fraction in Liquid-Gas Mixtures by Laser-Induced Breakdown Spectroscopy

Liquid Feed Injection in a High Density Riser

A system of two lenses is achromatic when the separation between them is

5 TH ERMAL GRADIENT INTERFEROMETRIC MEASUREMENT

For more information, please contact

Experimental Study on the Non-reacting Flowfield of a Low Swirl Burner

Simulation of laser propagation in plasma chamber including nonlinearities by utilization of VirtualLab 5 software

Experimental study of CO 2 releases from a saturated liquid reservoir

EE Camera & Image Formation

ENVR 116 Introduction to Aerosol Science December 17, 2001 FINAL EXAMINATION

1. For a simple harmonic motion governed by Hooke s Law, F = kx, if T is the period then the quantity T/2π is equal to

Convective Vaporization and Burning of Fuel Droplet Arrays

Paper ID ICLASS EFFECTS OF CAVITATION IN A NOZZLE ON LIQUID JET ATOMIZATION

OPTICAL DIAGNOSTICS TO STUDY SUPERCRITICAL CO 2 PROCESSES. A. Braeuer

Temperature and chemical composition of droplets by optical measurement techniques: a state-of-the-art review

Temperature, Pressure and Velocity measurements on the Ranque-Hilsch Vortex Tube

How does your eye form an Refraction

Characteristics of hydrogen supersonic cluster beam generated by a Laval nozzle

Phase Retrieval for the Hubble Space Telescope and other Applications Abstract: Introduction: Theory:

Development of optimized Raman Spectroscopy setup for species detection in flames

Non-intrusive sensing of air velocity, humidity, and temperature using TDLAS

Propagation dynamics of abruptly autofocusing Airy beams with optical vortices

6. Laser Doppler Anemometry. Introduction to principles and applications

LASER BASED DIAGNOSTIC SYSTEM FOR SPRAY MEASUREMENTS

Laboratory Studies of Fire Whirls (preliminary)

Entrained Air around a High Pressure Flat Jet Water Spray

Evolution of the pdf of a high Schmidt number passive scalar in a plane wake

OPTIMAL WAVELENGTH SELECTION ALGORITHM OF NON-SPHERICAL PARTICLE SIZE DISTRIBUTION BASED ON THE LIGHT EXTINCTION DATA

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Physics 1212 Exam #4A (Final)

Tomographic visualization of thermo-diffusive instabilities of lean hydrogen/air mixtures

Laser Excitation Dynamics of Argon Metastables Generated in Atmospheric Pressure Flows by Microwave Frequency Microplasma Arrays

Physics 1212 Exam #4B (Final)

Effect of Primary Spray Characteristics on the Spray Generated by an Airblast Atomizer under High-Pressure Conditions

Ablation Dynamics of Tin Micro-Droplet Target for LPP-based EUV light Source

A. Aleksandrov, H. Bockhorn

A study of droplet evaporation

ACOUSTIC EFFECTS OCCURRING IN OPTICAL BREAKDOWN WITH A LIQUID BY LASER RADIATION

Projected and slice emittance measurements using multi-quadrupole scan and streak readout at PITZ

Plasma Spectroscopy in ISTTOK

Using a Research Laboratory for training Students

A calibration-independent laser-induced incandescence technique for soot measurement by detecting absolute light intensity

Assignment 3 Due September 27, 2010

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Ch. 8 Introduction to Optical Atomic Spectroscopy

OPSE FINAL EXAM Fall 2016 YOU MUST SHOW YOUR WORK. ANSWERS THAT ARE NOT JUSTIFIED WILL BE GIVEN ZERO CREDIT.

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

Mixing at the External Boundary of a Submerged Turbulent Jet

The Fire Induced Ceiling Jet Revisited. Ronald L. Alpert, ScD, FSFPE Editor, Journal of Fire Protection Engineering Rockport, Cape Ann, MA USA

Mass flow determination in flashing openings

Final Practice Problems

Transition of laminar pre-mixed flames to turbulence - induced by sub-breakdown applied voltage

How does your eye form an Refraction

2D Methyl Radical Measurement in a Methane/Air Flame at Atmospheric. Pressure. Abstract

Phys102 Lecture Diffraction of Light

Fundamentals of Particle Counting

Physics 1252 Sec.A Exam #1A

LES Investigation of Fuel Effects on Lean Blow off (LBO) for a Realistic Two-Phase Flow Combustor

Flow and added small-scale topologies in a turbulent premixed flame

Fluorescence tracer technique for simultaneous temperature and equivalence ratio measurements in Diesel jets

Interfacial Flows of Contact Line Dynamics and Liquid Displacement in a Circular Microchannel

Advanced Turbulence Models for Emission Modeling in Gas Combustion

Time-resolved pump-probe system based on a nonlinear imaging technique with phase object

STUDY ON PHOTOELECTRIC CONFRONTATION OF WATER MIST SCREEN SYSTEM

Liquid-Rocket Transverse Triggered Combustion Instability: Deterministic and Stochastic Analyses

Instrumentation. Dr. Hui Hu Dr. Rye Waldman. Department of Aerospace Engineering Iowa State University Ames, Iowa 50011, U.S.A

Spatial phase-shifting moiré tomography

Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere

The Two-Phase Screw-Type Engine with Flash Evaporation

Transcription:

One-Dimensional Rainbow Technique to Characterize the Evaporation at Ambient Temperature and Evaporation in a Flame of Monodispersed Droplets Jantarat Promvongsa* 1,, Yingchun Wu 1,5, Gerard Grehan 1, Sawitree Saengkaew 1, Bundit Fungtammasan,3, Pumyos Vallikul 4 1 CNRS UMR 6614-CORIA, Rouen, France Joint Graduate School of Energy and Environment, King Mongkut s University of Technology Thonburi, Bangkok, Thailand 3 Center of Energy Technology and Environment, Bangkok, Thailand 4 Department of Mechanical and Aerospace Engineering, King Mongkut s University of Technology North Bangkok, Thailand 5 Clean Energy Utilization of National Key Laboratory Zhejiang University, Hangzhou, China *Corresponding author: jantarap@coria.fr Abstract This paper represents the ability of the newly introduced One-dimensional Rainbow Technique (ORT) to characterize the evaporation of monodispersed droplet in the large range of environment temperature. At the low temperature (room temperature), the small change of drop size is measured from the phase shift of ripple structure. The size change, as small as 1 nm for 8 µm droplet, can be measured. For the evaporation under high temperature of the combustion flame, the gradient of refractive index can be realized from the transition of extracted refractive index during the time. The non-monotonic function of refractive index time variation is observed due to the change of refractive index profile inside the droplet. Introduction Global rainbow technique (GRT) is one attractive technique for simultaneously measuring size and temperature (or composition). Because of the simple, inexpensive setup and fully predictable configurations, it gives us the chances to develop and adapt for various applications. Classically, this technique measures size distribution and averaged refractive index of the droplets in a spray at a point, which is spatially selected by the system of lenses and pinhole [1,]. In the system of the monodispersed droplet, the measurement of size and refractive index can be as accurate as.1 µm for diameter and the forth digit for refractive index by combining with the forward scattering pettern [3]. Since GRT has the point measurement probe, it does not provide the spatial evolution of droplet, i.e. the change of diameter, temperature and composition. To be able to follow those data from the moving droplets, the extension of GRT using slit apertures and laser sheet has been introduced by X.C. Wu., et. al. [4] and called as One-dimensional Rainbow Technique (ORT). The technique gives the possibility to follow the evolution (refractive index and size) of the droplet along the line. This paper applies the recently developed technique, ORT, to characterize the evaporation of the *Corresponding author: jantarap@coria.fr Proceeding of the European Combustion Meeting 15 monodispersed droplet under both cold condition and in combustion flame. The configuration of the monodispersed droplet gives a possibility to measure the change of droplet diameter (hence the evaporation rate). Since the change of droplet diameter along the line measurement probe is very small and the change of shape of the main rainbow is not sufficient for the measurement, then the phase shift of the ripple structure is observed alternatively. The refractive index is extracted without taking into account the radial gradient inside the droplet. Experimental setup The experimental setup is modified from the classical global rainbow technique. As illustrated in Fig 1, the continuous laser beam at 53 nm- wavelength is transformed to the laser sheet that is set to be vertical and coincident with the line of droplet. To collect the scattered light, the horizontal and vertical slits are installed in front of the first lens and at the image plane of the first lens. Accordingly, the position and dimension of the measurement volume can be specified. The distances of the first lens, the vertical slit, the second lens and the screen referred to the measurement volume are 5, 65, 71 and 1 mm, respectively.

Both lenses are plano-convex lenses with 15 mm focal length and 75 mm diameter. The sizes of vertical and horizontal slits are mm 75 mm and 1 mm 5 mm, respectively. The monodispersed droplets are generated by the use of the vibration of piezoceramic element breaking up the liquid jet. The studied liquid, N-heptane, is injected under ambient conditions with and without the flame. The droplet generator with 5 µm -pinhole diameter is operated at liquid flow rate.6 ml/min and excitation frequency 18.35 khz. The combustion flame is produced from the propane gas. A burner head is 15 mm above the orifice. After ignition, the combustion flame is stabilized and envelopes the line of droplets. The rainbow patterns scattered from the droplets at the different vertical position in the control volume are instantaneously recorded in one image. The relationship between the position of droplet and the position of the rainbow signal appeared on the screen is linear, while the magnification is the function of the focal length of the 1 st and nd lenses and the distance of the 1 st lens to the control volume and the nd lens to the screen [4]. In this experiment, the length of the control volume is 1 mm. Ten strips are selected from the image that corresponds to 1 vertical level of the droplet in the control volume with 1 mm apart, as illustrated in Fig. Each strip is averaged along the column. The measurement position is varied from 5 to 35 mm away from the burner head by 5 mm step. Hence, 5 mm overlap between the measurement positions is obtained. At each measurement positions, a series of images are recorded continuously at 67.6 ms of exposure time and 14.7 fps of sampling rate. The averaged images for each position are used to extract the average size and refractive index. Figure 1: The schematic diagram (top) and the real setup (bottom) of ORT From each averaged image, the phase shift of ripple of rainbow signal at each level relative to the rainbow signal at the lowest level of the image is calculated. The global rainbow inversion program based on Nussenzvieg theory is used to extract the size distribution and averaged refractive index of droplets. The measurements are carried out at two conditions, (i) evaporation in ambient conditions and (ii) evaporation in the combustion flame. Figure : The selected rows and the corresponding relative position of droplets

Evaporation in atmospheric conditions In the first case, the averaged rainbow images show clearly the ripple structure as shown in Fig 3. The plot of intensity distribution versus the calibrated scattering angle shows that the ripple structure shifts to the higher angle when the droplet moves farer from the nozzle as the diameter decreases. The phase change is almost in fully one period () within measurement range of 1 mm. The intensity at each row is affected by the Gaussian distribution of the laser sheet. Firstly, the global rainbow inversion program is used to extract size and refractive index of droplets. From this process, the size of droplet is around 75-85 µm. As shown in Fig 4, the obtained refractive index is varying between 1.39 and 1.39, which higher than its refractive index at o C. This means the temperature of droplet reduces to its saturation temperature corresponding to the room temperature and pressure, in this experiment is o C and 1atm, respectively. After that, the phase change of the ripple structure is calculated. The calculated phase shift is used to calculate the diameter change of the droplets by using the relationship provided from the rigorous simulated rainbow signal correlated to its extracted phase shift. The plots of the obtained phase shift () and diameter change (D) versus the relative position are shown in Fig 5. In order to estimate the evaporation rate, the velocity of the droplet is necessary to transform the relative position of droplet into time. In this work, droplet velocity is 5.1 m/s, which is the velocity of the liquid jet at the orifice estimated from the liquid flow rate and pinhole diameter. Then, the D²-t curve is performed, as shown in Fig 6. The initial time (t=) is referred to the position closest to the burner in the measurement; that is about 5 mm from the burner. The evaporation rate of droplets is estimated from the linear regression following the D² law equation as: D D D Kt D ( t) (1) where D is the absolute diameter of droplet and K is the evaporation constant. Extracted refractive index 1.394 1.39 1.39 1.388 1.386 1 3 4 n_heptane@ o C Figure 4: The extracted refractive index of droplets in the atmospheric conditions radian) 7 6 5 4 3 1 15mm mm 5mm 3mm 35mm 4 6 8 1 1..15.1.5. Figure 5: The ripple phase shift and corresponding relative diameter under o C and 1 atm D=D-Di ( m) Figure 3: The recorded rainbow signal and the intensity distributions. 3

645 64 15 mm, K=1.478x1-9 m /s mm, K=1.391x1-9 m /s 5 mm, K=1.34x1-9 m /s 1.4 D (µm ) 6395 639 6385 638 6375 637 6365..5 1. 1.5..5 t (ms) 3 mm, K=1.6x1-9 m /s 35 mm, K=1.18x1-9 m /s Linear regression Rainbow refractive index (n rg ) 1.39 1.38 1.37 1.36 1.35 nrg@nc=1.37 nrg@nc=1.375 nrg@nc=1.38 ns nc=1.37 nc=1.375 nc=1.38 Figure 6: D²-t curve of data from Fig 5 by assuming D =8 µm and v=5.1 m/s Evaporation in combustion flame When the combustion flame is introduced, the turbulence and high temperature of the flame enhance the evaporation rate of droplet and affect to the droplet velocity. Moreover, the temperature or refractive index inside droplet is not uniform. The numerical study on the effect of the radial gradient of refractive index on the rainbow signal can be found in published papers [5-8]. Generally, the refractive index profile is assumed to be the exponential function as: 1 ( ~ br e n r ) n ( ) c ns nc () b e 1 where r ~ is the dimensionless radial distance from droplet center, n c and n s are respectively the values of the refractive index at droplet center and surface. The parameter b defines the shape of the refractive index profile. In the burning or heating process, in which the heat transfers from the environment to the droplet surface, the gradient is strong at the droplet surface and, hence, the parameter b is positive. Firstly, the rainbow signals from the droplet with the radial gradient are numerically simulated and then inversed by the inversion program to extract the rainbow refractive index, n rg, which is a single value of refractive index of the non-uniform droplet. Based on the defined value n s =1.3446 (the refractive index of n- heptane at the boiling point), the plot of rainbow refractive index versus b is shown in Fig 7. The interesting result is that the rainbow refractive index is non-monotonic function and is mostly outside the range of the values of refractive index in the droplet. This specific behavior is supposed to obtain in this experiment. ~ 1.34 1 3 4 b Figure 7: Rainbow refractive index extracted from the simulated rainbow signal of non-uniform refractive index droplet at n s =1.3446 versus the varied value b corresponding to Eq (). Same experimental configuration is carried out but with the presence of combustion flame. During 15 minutes of the experiment, including recording, saving data and changing the measurement point, the flame is maintained. Hence, the air between the orifice and burner head is heated up by the flame. It was found that the temperature of the air increases around 1 o C in a roll of the experiment. With exposure time of the camera at 67.6 ms, the rainbow pattern from a large number of droplets of different sizes and refractive indices are summed up eliminating the ripple structure. The size change of droplet is no longer measured by the approach mentioned earlier. Only the inversion program based on the Nussenvieg theory is used to process the signal. Plot of refractive index measured under combustion flame is shown in Fig 8 compared with that measured in room temperature. The results show that the droplets behavior can be traced well and continuously. Note that, the inversion process for the refractive index is based on the assumption of homogeneous refractive index inside droplet. Then, the obtained refractive index is called rainbow refractive index. At the beginning, just before the droplets reach to the flame, the refractive index of droplet in the flame is lower than that of droplet in the room condition. In the opinion of authors, this is because the air between the orifice and burner head is heated up and then the saturation temperature of droplet increases. After that, the refractive index increases up to the maximum value. As the consequence of gradient of refractive index, the 4

time variation of rainbow refractive index is not the monotonic function. From the maximum point, the refractive index decreases continuously and tends to reach the refractive index at the boiling point. As expected, the results are similar to the rainbow refractive index of the droplet with radial gradient refractive index. It can be realized that the gradient of refractive (or temperature) inside droplet is presence especially at the first 1 mm from the burner. Extracted refractive index 1.39 1.38 1.37 1.36 1.35 5mm 1mm 15mm mm 5mm 3mm 35mm without flame n@ o C n@98 o C 1.34-1 1 3 4 5 Figure 8: Measured refractive index of monodispersed n-heptane droplets with and without flame from 7 setup positions corresponding to 7 measurement points from 5 to 35 mm Conclusions The recent work shows the application of the Onedimensional Rainbow Technique on the characterization of evaporating monodispersed droplets under two different conditions. First, at the cold temperature where the evaporation rate is small, the recorded rainbow signal is close to that obtained from the Standard Rainbow Technique (SRT). Hence, the nanometric change of droplet size can be measured by observing the phase shift of the ripple structure. The refractive index (or temperature) of droplet is nearly constant. The accurate calibration method and measurement of droplet velocity are suggested to improve the accuracy of the evaporation rate. Second, for the rapid heating and evaporation under the combustion flame, the characteristics are more complicate. This paper presents the possibility to measure the gradient of refractive index inside the droplet. The presence of refractive index gradient is realized from the non-monotonic function of the obtained rainbow refractive index. To approximate the refractive index profile, the numerical calculation and the boundary values (refractive index at droplet center and surface) are required. Acknowledgements The authors are pleased to acknowledge the financial support of INTERREG through E3C3 project. The first and the fifth authors were supported by Thailand Research Fund (TRF) through the Golden Jubilee PhD. Program (Grant No. PHD/7/551). References [1] J. P. A. J. van Beeck, D. Giannoulis, L. Zimmer, M. L. Riethmuller, Optics letters 4(3) (1999) 1696-1698. [] S. Saengkeaw, Development of Novel Global Rainbow Technique for Characterizing Spray Generated by Ultrasonic Nozzle, PhD thesis, Chulalongkorn University, Bangkok, Thailand, 5. [3] S. Saengkaew, T. Charinpanitkul, C. Laurent, Y. Biscos, L. Gerard,, G. Lavergne, G. Gouesbet, G. Grehan,Exp. Fluids 48:111-119 (1). [4] X. Wu, H. Jiang, Y. Wu, J. Song, G. Grehan, S. Saengkaew, L. Chen, X. Gao, K. Cen, Optics Letters 39(3) (14) 638-641. [5] K. Anders, N. Roth, A. Frohn, Part. Part. Syst. Charact. 13 (1996) 15 19. [6] M. R. Vetrano, J. P. A. J. van Beeck, M. L. Riethmuller, Applied Optics 44(34) (5) 775-781. [7] J. A. Adam, P. Laven, Applied Optics 46(6) (7) 9-99. [8] S. Saengkaew, T. Charinpanitkul, H. Vanisri, W. Tanthapanichakoon, Y. Biscos, N. Garcia, G. Lavergne, L. Mees, G. Gouesbet, G. Grehan, Exp. Fluids 43 (7) 595-61. 5