Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor and Environs, Aniocha- South Local Government Area, Delta State, Nigeria

Similar documents
Geoelectric Evaluation of Groundwater Potential: A Case Study of Sabongida-Ora and Environs, Southern Nigeria

Accepted 15 December, 2012

Vertical Electrical Sounding Survey for Groundwater Exploration in Parts of Anyigba and its Environs, in the Anambra Basin of Nigeria

Geophysical Investigation of Ground Water Using Vertical Electrical Sounding and Seismic Refraction Methods

Groundwater Exploration In Parts Of Mangu- Halle North-Central Nigeria.

Scholars Research Library. Geophysical investigation of effects of topographic complexities on groundwater potential in Ibusa, Delta State Nigeria

Scholars Research Library. Predicting the aquifer characteristic within the major towns in Ndokwa land

Aquifer Vulnerability Investigation Using Geoelectric Method in Parts of Sapele Local Government Area of Delta State, Nigeria

1-D Electrical Resistivity Survey For Groundwater In Ketu-Adie Owe, Ogun State, Nigeria.

Scholars Research Library

Analysis of electrical resistivity data for the determination of aquifer depth at Sapele RD in Benin city

Scientific Research Journal (SCIRJ), Volume IV, Issue XI, November ISSN

Geophysical Study of Limestone Attributes At Abudu Area of Edo State, Nigeria

FORMATION EVALUATION OF SIRP FIELD USING WIRELINE LOGS IN WESTERN DEPOBELT OF NIGER DELTA

Groundwater Assessment in Apapa Coast-Line Area of Lagos Using Electrical Resistivity Method

Aquifer Vulnerability Assessment in Some Towns of Yenagoa, South-South Nigeria

Elijah Adebowale Ayolabi, Ph.D. 1, Adetayo Femi Folorunso, M.Sc. 2*, Ayodele Franklin Eleyinmi, B.Sc. 1, and Esther O. Anuyah, B.Sc.

3D Electrical Resistivity Tomography (ERT) Survey of a Typical Basement Complex Terrain

GEOELECTRICAL INVESTIGATION OF GROUNDWATER CONDITION IN OLEH, NIGERIA

Aspects of Geophysical Exploration for Groundwater Using Vertical Electrical Sounding (VES) in Parts of University of Benin, Benin City, Edo State

Groundwater Exploration of Lokpaukwu, Abia State Southeastern Nigeria, Using Electrical Resistivity Method

VOL. 3, NO. 9, September 2013 ISSN ARPN Journal of Science and Technology All rights reserved.

Petrophysical Charaterization of the Kwale Field Reservoir Sands (OML 60) from Wire-line Logs, Niger Delta, Nigeria. EKINE, A. S.

Hydro-Geophysical Study of River Niger Floodplain at Jebba-North, Nigeria

Imaging complex structure in seismic reflection data using prestack depth migration: case study of Olua area of the Niger Delta, Nigeria

Determination of Ground Water Flow Direction in Ndokwa Land Area of Delta State Nigeria, using Combined Drilled Hole and Global Positioning System.

Ground-Water Exploration in the Worthington Area of Nobles County: Summary of Seismic Data and Recent Test Drilling Results

International Journal of Scientific & Engineering Research, Volume 7, Issue 3, March ISSN

Determination of Thickness of Aquifer with Vertical Electrical Sounding

2D Resistivity Imaging Investigation of Solid Waste Landfill Sites in Ikhueniro Municipality, Ikpoba Okha Local Government Area,Edo State, Nigeria.

Geophysical Investigation of Egbeta, Edo State, Nigeria, Using Electrical Resistivity Survey to Assess the Ground water Potential

Subsurface Characterization using Electrical Resistivity(Dipole-Dipole) method at Lagos State University (LASU) Foundation School, Badagry

Vertical electrical sounding (VES) for subsurface geophysical investigation in Kanigiri area, Prakasam district, Andhra Pradesh, India

Relevance of 2D Electrical Imaging in Subsurface Mapping: Case Study of National Animal Production Research Institute (NAPRI), Zaria.

2d Geoelectric Evaluation and Imaging of Aquifer Vulnerability of Dump Site at Ozoro Isoko South Lga of Delta State

Vertical Electrical Sounding for Aquifer Characterization around the Lower Orashi River Sub-Basin Southeastern Nigeria

Hydro-Geophysical Investigation of the Federal Housing Estate Akure, Southwestern Nigeria

Journal of Environment and Earth Science ISSN (Paper) ISSN (Online) Vol 2, No.3, 2012

1. Department of Physics University of Port Harcourt, Nigeria.

The Use of Vertical Electrical Sounding (VES) for Subsurface Geophysical Investigation around Bomo Area, Kaduna State, Nigeria

Scholars Research Library

MICRO LEVEL GEO-RESISTIVITY SURVEY THROUGH V.E.S. TEST FOR GROUNDWATER FEASIBILITY STUDY AND SELECTION OF BORE WELL SITES IN PIPILI BLOCK OF PURI

DC Resistivity Investigation of Anisotropy and Lateral Effect using Azimuthal Offset Wenner Array. a case Study of the University of Calabar, Nigeria

AQUIFER SYSTEMS OF NDOKWA LAND DELTA STATE, NIGERIA

Lithofacies Characterization of Sedimentary Succession from Oligocene to Early Miocene Age in X2 Well, Greater Ughelli Depo Belt, Niger Delta, Nigeria

Determination of Incompressibility, Elasticity and the Rigidity of Surface Soils and Shallow Sediments from Seismic Wave Velocities

Geophysical Investigation of Some Flood Prone Areas in Ota, Southwestern Nigeria

Geophysical Investigation of Foundation Condition of A Site in Ikere- Ekiti, Ekiti State, South-Western Nigeria

GSJ: Volume 6, Issue 4, April 2018, Online: ISSN

2-D RESISTIVITY IMAGING SURVEY FOR WATER-SUPPLY TUBE WELLS IN A BASEMENT COMPLEX: A CASE STUDY OF OOU CAMPUS, AGO-IWOYE SW NIGERIA

AQUIFER CHARACTERIZATION AND GROUNDWATER POTENTIAL ASSESSMENT OF THE SEDIMENTARY BASIN OF ONDO STATE. Faleye, E. T. and Olorunfemi, M. O.

ASSESSMENT OF GROUNDWATER POTENTIAL IN ARUJO- RODI KOPANY AREA, HOMA BAY COUNTY, KENYA. NAME: AYETE DAVID OMAJILONG

RESISTIVITY IMAGING AND BOREHOLE INVESTIGATION OF THE BANTING AREA AQUIFER, SELANGOR, MALAYSIA. A.N. Ibrahim Z.Z.T. Harith M.N.M.

Assessment of Ground Water in a Part of Coastal West Bengal using Geo-Electrical Method

Journal of Environment and Earth Science ISSN (Paper) ISSN (Online) Vol.6, No.2, 2016

INTEGRATED GEOPHYSICAL INVESTIGATION OF SEQUENCE OF DEPOSITION OF SEDIMENTARY STRATA IN ABAKALIKI, NIGERIA ABSTRACT

RESISTIVITY IMAGING OF CRUDE OIL SPILL IN OGULAHA COASTAL COMMUNITY, BURUTU L.G.A, DELTA STATE, NIGERIA

Vertical Electrical Sounding (Ves) For The Determination Of Under Ground Resistivity In Part Of Nigeria Wilberforce Island,Amassoma, Bayelsa State

Investigation of Aquifer Quality in Bonny Island, Eastern Niger Delta, Nigeria using Geophysical and Geochemical Techniques

International Journal of Basic and Applied Sciences Raibu et. al., Vol. 1 No. 2 ISSN: (A peer reviewed International Journal)

Electrical Resistivity Survey Forground Water At Eye Zheba Village, Off Bida - Minna Road

Petrographic, Well Logging and Well Log Analysis of a Wellbore at Umueze in Orlu, Southeastern Nigeria

Effect of multicyclic compaction on cohesion in lateritic soils

Preliminary Evaluation of Some Engineering Geological Properties of Soils in the New Yenagoa Town, Bayelsa State, Central Niger Delta

Evaluation of Ground Water Potential Status in Nkanu-West Local Government Area, Enugu State, Nigeria

Geophysical Investigation: A Case Study of Basement Complex, Nigeria

Evaluation of Subsurface Formation of Pabna District, Bangladesh

Underground water exploration of Oleh, Nigeria using the electrical resistivity method

Application of Remote Sensing and Geo-Electrical Method for Groundwater Exploration in Khor Al Alabyad, North Kordofan State, Sudan

K. S. OKIONGBO AND G. C. SORONNADI-ONONIWU

Index Terms- Apparent Resistivity, Aquifer, Geoelectric Section, Piezometric Surface.

International Journal of Scientific & Engineering Research, Volume 7, Issue 11, November ISSN

Granulometric Analysis of Sandstone Facies of Late Maastritchian Nsukka Formation Outcrops in Ihube and Isiukwuato Areas, Southeastern Nigeria

AN INTEGRATED GEOPHYSICAL INVESTIGATION OF A SPRING IN IBUJI, IGBARA-OKE, SOUTHWESTERN NIGERIA.

Causes of Borehole Failure in Complex Basement Terrains: ABUAD Case Study, Southwestern Nigeria. w w w. a j e r. o r g Page 192

A Preliminary Geophysical Reconnaissance Mapping of Emirau Ground Water Resource, Emirau Island, New Ireland Province, PNG

The impact of geologic setting on the groundwater occurrence in the Eocene limestone of El Minia-East Nile-Egypt, using geoelectrical technique

GEO-ELECTRIC INVESTIGATION OF THE GROUNDWATER POTENTIAL DISTRIBUTION WITHIN GWALE LOCAL GOVERNMENT AREA OF KANO STATE NIGERIA

Ground Magnetic and Electrical Resistivity Mapping for Basement Structurs over Charnokitic Terrain in Ado-Ekiti Area, Southwestern Nigeria

Morenikeji P. Anjorin, B.Tech. 1 and Martins O. Olorunfemi, Ph.D. 2*

Determination of Geothermal Gradient in the Eastern Niger Delta Sedimentary Basin from Bottom Hole Temperatures

Hydrogeophysical investigation in selected parts of Irepodun/Ifelodun local government area of Ekiti State, Southwestern Nigeria

Evaluation of the Aquifer Characteristics of Some Parts of Orsu, South-Eastern Nigeria.

Groundwater Studies in Abakaliki Using Electrical Resistivity Method

Available online at Pelagia Research Library. Advances in Applied Science Research, 2011, 2 (1):

A surficial. P^HiHI waste disposal site, Bureau County, Illinois. east of the Sheffield low-level radioactive. electrical resistivity survey

Geophysical Investigation of the Precambrian Marble Occurrence in Itobe Area, Central Nigeria

VOL. 7, NO. 5, MAY 2012 ISSN ARPN Journal of Engineering and Applied Sciences

GROUNDWATER INVESTIGATION USING GEOPHYSICAL METHODS- A CASE STUDY OF PYDIBHIMAVARAM INDUSTRIAL AREA

Application of Resistivity Methods to Groundwater Protection Studies in Niger Delta

Adebayo O. Ojo, M.Sc. 1* and Martins O. Olorunfemi, Ph.D *

Hydrocarbon Potential of the Marginal Fields in Niger Delta Oza Field, a case study*

Geophysical investigations for groundwater exploration in a crystalline basement, southwest Nigeria

DELINEATION OF FRESH-BRACKISH WATER AND BRACKISH-SALINE WATER INTERFACES USING VES SOUNDINGS IN SHANI, BORNO STATE, NIGERIA

11/22/2010. Groundwater in Unconsolidated Deposits. Alluvial (fluvial) deposits. - consist of gravel, sand, silt and clay

Estimation of Water Saturation Using a Modeled Equation and Archie s Equation from Wire-Line Logs, Niger Delta Nigeria

Report and Opinion 2010;2(5)

International Journal of Scientific & Engineering Research, Volume 6, Issue 12, December ISSN

Geophysical Investigation of Loss of Circulation in Borehole Drilling: A Case Study of Auchi Polytechnic, Auchi, Edo State, Nigeria

Applied Physics Research Vol. 3, No. 2; November 2011

Transcription:

JASEM ISSN 1119-8362 All rights reserved Full-text Available Online at www.ajol.infoand www.bioline.org.br/ja J. Appl. Sci. Environ. Manage. June 2017 Vol. 21 (4) 682-690 Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor and Environs, Aniocha- South Local Government Area, Delta State, Nigeria Department of Geology, Faculty of Science, Delta State University, P.M.B. 1, Abraka, Delta State E-mail: fichinyem@gmail.com ABSTRACT: Geoelectric investigation for groundwater prospects in Ejeme-Aniogor and environs, Aniocha- South Local Government Area of Delta State, Nigeria was carried out with a view to determining the near subsurface lithologies and depths; as well as thickness of the various aquiferous zones/units in the study area. Fourteen vertical electrical soundings (VES) technique, employing the Schlumberger configuration were used in investigating the groundwater prospects, with maximum current electrode spacing of 500m. The acquired field data were interpreted quantitatively by partial curve matching and computer iteration. The result showed six to eight geoelectric layers with resistivities ranging from 120 to 1700 Ω for the topmost layer and 276 to 163000 Ω for the bottommost layer. The result also revealed that the depths to the various aquiferous zones ranged from 28.5 to 162 m while the thickness of the aquiferous zones ranged from 20.3 to 58.7 m. The aquiferous units in the study area were mostly confined and the results obtained from the study were found to be consistent with the lithologic logs obtained from borehole drilled in the study area. A generalized depth to the water table (acquiferous zones) cannot be deduced for the study area because it varied from one locality to another. However, the result showed that the area has good prospects for groundwater development. JASEM https://dx.doi.org/10.4314/jasem.v21i4.8 Keywords: Geoelectric investigation, groundwater prospects, Ejeme Aniogor, aquiferous zones, groundwater development. Water is health, water is wealth and water is life. Good drinking water can be obtained from rocks, but drilling without previous site investigations seldom yield water in useful quantities (Palacky et al., 1981). Effective water development programmes must include carefully conducted geological and geophysical investigations. Water is one of the essential necessities of nature indispensable to all organic life plant and animal development (Obioha and Nwachukwu, 2007). It occurs in springs, rivers, streams and lakes in surface basins, falls as rain and occurs in the subsurface in porous, permeable rocks formations as groundwater. The importance of groundwater as a supply source to the socioeconomic development of a country is very great. In this 21 st century, there is increasing demand for water supply for physical industrial development to achieve maximum human growth (Olasehinde, 2011). Groundwater is by far the most important source of drinking water in Nigeria (Goki, 2011). It is tapped through wells and bore holes in most urban and rural areas. Geo-electrical techniques are powerful tools and play a vital role in groundwater investigations particularly in the delineation of the aquifer configuration in geological environments (Olasehinde, 2011). A planned geo-electrical investigation is capable of mapping an aquifer system, clay layers, the depth and thickness of aquifers etc, and this has been adopted for in this study. Investigation of depths to water tables in Ejeme- Aniogor and environs is imperative because of rampant cases of boreholes with poor water yield, boreholes getting dried up soon after commission and sometimes outright abandonment even amongst those owned by the state government. This study is therefore aimed at investigating the near surface geologic formations in the area in view of groundwater development. It involved the use of vertical electrical sounding (VES) technique, employing Schlumberger electrode configuration at fourteen VES locations in Ejeme-Aniogor and environs. Borehole litho-logic log was incorporated into the interpretation to minimize discrepancies in deduced geo-electric parameters and that obtained from bore holes. It is hoped that the results of this investigation would be of immense importance in future groundwater development program in these areas, as it would provide information on probable depths to suitable aquiferous units. The objective of this present study was to investigate the groundwater prospect in Ejeme Aniogor and Environs, Aniocha South Local Government Area, Delta State, because of increasing demand for potable water by the inhabitants. MATERIALS AND METHODS Description of Study Area with Map and Location: The study area is located within longitude 6 0 17 0 to *Corresponding author E-mail: fichinyem@gmail.com

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 683 6 0 24 0 E of the Greenwich Meridian and latitude 6 0 00 1 to 6 0 05 1 N of the Equator and is accessible by major and minor roads. Ejeme Aniogor and environs consists of semi-urban towns. The elevation of the area ranges from 55 to 102 m above sea level.the area is well drained by two rivers: River Adofi and River Omu. and the drainage pattern is basically dentritic. The drainage system is dominated by River Adofi which has its source at Ejeme-Aniogor and flows southwards towards Ossissa in Ndokwa- East Local Government Area of Delta State before it empties its water into the River Niger. The area falls within the localities where the lithofacies of the Niger Delta grade gradually into the lithofacies of the Anambra basin (Freeborn, 2006). It is underlain from the earth s surface by the Benin Formation, Ogwashi Asaba Formation and Ameki Formation, with equivalent of Upper Agbada Formation (Reyment, 1965). The geology of the Niger Delta has been described extensively by Allen (1965); Burke et al., (1972) Short and Stauble (1967) and Murat (1970). It consists basically of three diachronous stratigraphic units viz: the Benin, Agbada and Akata Formations. The Benin Formation is dominantly a fluvial facies unit made up of 90% sand/sandstone and clay intercalations. The age ranges from Oligocene to recent (Reyment, 1965). The Agbada formation is a Deltaic facies unit made up of an alternating sequence (sandstone shale). This sequence is in response to eustatic changes in sea level during sedimentation. The age ranges from Eocene to Recent. The Akata Formation is an open marine faces (pro-delta) unit dominated by under pressured shale of 2000 to 4000m in thickness. The age ranges from Paleocene to Recent (Reyment, 1965). Fig 1: Map of Niger Delta Showing the Location of Study Area

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 684 Data Sampling: The electrical resistivity data were acquired using the ABEM Signal Averaging System (SAS) 1000 Terrameter Resistivity meter. The survey involved 1-D Vertical Electrical Sounding (VES) and the VES utilized the Schlumberger electrode array with half current electrode separation (AB/2) that ranged from 1 to 500m depending on accessibility. A total of fourteen VES stations were occupied (Figure 1). The coordinates of each VES station were taken with the Garmin Global Positioning System (GPS) equipment to ensure correct future geo referencing. Data Processing and Data Interpretation: The observed field data were used to produce depth sounding curves. The Signal Averaging System (SAS 1000) Terrameter Resistivity Meter, which was used for data acquisition could compute and display the apparent resistivity of the subsurface layer with the input data of the electrode configuration, the current and potential electrode separation (Chinyem 2013). The VES data presented as depth sounding curves (Figures 2 and 3) were inverted with the aid of computer aided iteration curve matching techniques. The apparent resistivity obtained was plotted on a log log graph paper with the electrode separation (AB/2) on the abscissa and apparent resistivity ( a ) values as the ordinate. The thickness and resistivity values obtained from the partial curve matching were then used for a quantitative computer iteration using the Schlumberger O Neil software package (Schlumberger, 1986). Thus, the iterated geoelectric parameters were used to generate geo electric sections (Figures 5 and 6) for the study area. The geologic interpretation of the VES results was aided by the litho logic log of a borehole drilled in the area by the Delta State Ministry of water Resources (DSMWR; 2010), Asaba (Figure 4). RESULTS AND DISCUSSION The results of the investigation are presented, sounding curves and geo-electric sections (Figures 2 and 3). Figures 5 and 6 show the geo-electric sections of the study area. ( ) (Ωm) AB/2 (m) Fig 2: Typical Sounding Curve for Ejeme-Aniogor and Environs (VES 1)

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 685 ( ) (Ωm) AB/2 (m) Fig 3: Typical Sounding Curve for Ejeme-Aniogor and Environs (VES 9) 13.06 24.1 30.1 Lateritic Sand Fine sand Fine medium grained sand Medium Coarse grained sand Fig 4: Borehole lithologic log at Ejeme Aniogor. (Courtesy: Delta State Ministry of Water Resources (DSMWR), 2010)

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 686 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 Depth A 26100Ω VES 1 VES 2 VES 5 VES 4 26100Ω 48800Ω 23700Ω 27100Ω 0 0.7km Scale 509Ωm 561Ωm 2530Ωm 6320Ωm 667Ωm 12700Ω 3110Ωm 4510Ωm 5040Ωm Key 38205Ω 444Ωm 1710Ωm 9700Ωm 17400Ω 7900Ωm 466Ωm B Lateritic top soil Lateritic Sand Fine Lateritic Sand Fine grained sand Fine to medium grained sand Medium coarse grained Medium grained Coarse grained sand Coarse/gravelly sand Gravelly Sand Surfac Fig 5: Geoelectric section of the VES results (VES 1,2,4 and 5)

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 687 Depth (m) VES 4 Adofi River VES 10 EjemeUnor VES 9 VES 8 Surface 10 20 2000Ωm 9700Ωm 820Ωm 40600Ωm 355Ωm 4900Ωm 15000Ωm 30 1920Ωm 40 17400Ωm 8000Ωm 50 60 70 466Ωm 728Ωm 80 90 100 276Ωm 6620Ωm 110 466Ωm 120 130 140 15500Ωm 160 13900Ωm B 0 0.7km Scale Key Fig 6: Geoelectric Section of the VES results (VES 4,8,9,10) Lateritic top soil Lateritic Sand Fine Lateritic Sand Fine grained sand Fine to medium grained sand Medium coarse grained sand Medium grained Coarse grained sand Coarse/gravelly sand Gravelly Sand C VES 1 location (Market Square, Ejeme Aniogor; Latitude 06 0 00 1 50.83 11 N; Longitude 06 0 21 1 12.20 11 E )is made up of eight layers with resistivities that ranged from 460 to 48800 Ωm, depth ranging from 0.8 to 172 m. This location has an altitude of 62 m. The lithologies inferred include: lateritic top soil for the first layer; lateritic sand for the second layer; fine lateritic sand for the third layer; medium to coarse grained sand for the fourth layer; coarse grained sand for the fifth layer; coarse/gravelly sand for the sixth layer; coarse grained sand for the seventh layer and gravelly sand for the eight layer. The aquiferous unit delineated lies within layer 4 with resistivity of 2050Ωm, depth and thickness of 28.5 m and 20.3 m respectively.

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 688 VES 2 location (Along Obidugbo road, Ejeme Aniogor; latitude 06 0 00 1 54.34 11 N; longitude 06 0 21 1 13.36 11 E) is made up of seven layers with resistivity values that ranged from 206 to 12700Ωm and depth ranging from 0.6to 205 m. VES 2 location has an altitude of 73 m. The lithologies inferred include: lateritic top soil for the first layer; fine lateritic sand for the second layer; coarse grained sand for the third layer; coarse/gravelly sand for the fourth layer; medium-coarse grained sand for the fifth layer; coarse grained sand for the sixth layer and coarse grained sand for the seventh layer. The aquiferous unit\zone delineated lies within layer five with resistivity of 3110 Ωm, depth and thickness of 127 m and 58.7 m respectively. VES 3 location (Aniogor Primary School, Ejeme Aniogor; latitude 06 0 00 1 54.98 11 N; longitude 06 0 21 1 33.54 11 E) is made up of six layers with resistivity values which ranged from 555 to 25800 Ωm and depth range from 0.8 to 117 m. This location has an altitude of 70m. The deduced lithologies include: lateritic top soil for the first layer; fine lateritic sand for the second layer; medium grained sand for the third layer; coarse grained sand for the fourth layer; medium-coarse grained sand for the fifth layer and coarse/gravelly sand for the sixth layer. The aquiferous unit delineated lies within the fifth layer with resistivity value of 1240 Ωm, depth and thickness of 117 m and 75 m respectively. This location is regarded as potential aquiferous unit, hence better boreholes drilled at that depth will have good water yield. VES 4 location (Ejeme Secondary School, Ejeme Aniogor; latitude 06 0 01 1 32.56 11 N; longitude 06 0 21 1 25.71 11 E) is made of sevenlayers with resistivity values that ranged from 259to 17400 Ωm and depth from 0.9 to 77.5 m. The altitude of this location is 76 m. The deduced lithologies includes: lateritic top soil for the first layer; fine-medium grained sand for the second layer; coarse grained sand for the third layer; coarse/gravelly sand for the fourth layer; gravelly sand for the fifth layer; coarse/gravelly sand for the sixth layer and medium-coarse grained sand for the seventh layer. The aquiferous unit lies within the third layer (first aquifer) with resistivity of 2000 Ωm, depth and thickness of 17.4 m and 12.7 m respectively and also in the sixth layer (second aquifer) with resistivity value of 7900Ωm, depth and thickness of 77.5 m and 23.4 m respectively. VES 5 location (Ogbe-Unor Quarters, Ejeme Aniogor, latitude 05 0 01 1 07.37 11 N; longitude 06 0 21 1 19.70 11 E) is made up of six layers with resistivity values that ranged from 166 to 3820 Ωm and depth from 0.7to 75.2 m. This location has an altitude of 72m. The deduced lithologies include: lateritic top soil for the first layer; fine grained sand for the second layer; fine to medium grained sand for the third layer; coarse grained sand for the fourth layer; medium to coarse grained sand for the fifth layer and medium grained sand for sixth layer. The aquiferous unit lies within the fifth layer with resistivity of 1710 Ωm, depth and thickness of 75.2 m and 26.2 m respectively. VES 6 location (Umu Agolo Quarters, Ejeme Aniogor; latitude 06 0 01 1 00.09 11 N; longitude 06 0 21 1 24.28 11 E) is made up of six layers with resistivity that ranged from 120 to 138000 Ωm and depth ranging from 0.4 to 46.6 m. The altitude of this location is 69 m. The deduced lithologies include: lateritic top soil for the first layer; lateritic sand for the second layer; coarse grained sand for the third layer;course/gravel sand for the fourth layer; coarse grained sand for the fifth layer and coarse grained sand for the sixth layer.the aquiferous unit delineated lies within fifth layer with resistivity of 33000 Ωm with depth and thickness of 46.6 m and 24.5 m respectively. VES 7 location (Obelese Quarters, Ejeme Aniogor; latitude 06 0 01 1 00.45 11 N; longitude 06 0 21 1 24.87 11 E) consists of six layers with resistivity values which ranged from 131 to 1740 Ωm, depth range from 0.6to 98.4 m. This VES location has an altitude of 68 m. The deduced lithologies include: lateritic top soil for the first layer, fine-medium grained sand for the second layer, coarse grained sand for the third layer, medium to coarse grained sand for the fourth layer, coarse grained sand for the fifth layer and mediumcoarse grained sand for the sixth layer. The deduced aquiferous unit lies within fourth layer with resistivity of 1690 Ωm, depth and thickness of 63.7 m and 24.1m respectively. VES 8 location (Police station, Ejeme Unor; latitude 06 0 01 1 50.74 11 N; longitude 06 0 22 1 41.00 11 E) is made up of six layers with resistivity values that ranged from 820 to 139000 Ωm and depth range from 1.9 to 148 m. The altitude of this location is 71 m. The deduced lithologies include: lateritic top soil for the first layer; fine to medium grained sand for the second layer; coarse grained sand for the third layer; medium to coarse grained sand for the fourth layer; coarse/gravelly sand for the fifth layer and coarse/gravelly sand for the sixth layer. The aquiferous unit lies within the fourth layer with resistivity of 6620 Ωm, depth and thickness of 97m and 67.7 m respectively. This location is regarded as potential aquiferous zone and borehole drilled at this depth will have good water yield. VES 9 location (Adofi Primary School, Ejeme Unor; latitude 06 0 01 1 09.54 11 N; longitude 06 0 22 1 25.53 11 E) is made up of six layers with resistivity that ranged from 212 to 163000 Ωm, and depth range from 1.7 to 90.2 m. This location has an altitude of 66 m. The deduced lithologies include: lateritic top soil for the

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 689 first layer; fine to medium grained sand for the second layer; medium grained sand for the third layer; medium grained sand for the third layer; medium-coarse grained sand for the fourth layer;coarse/gravelly sand for fifth and sixth layers respectively. The prospective aquiferous unit lies within the fourth layer with resistivity value of 8000 Ωm, depth and thickness of 50.4 m and 32.4 m respectively. VES 10 location (Obi s Palace, Ejeme Unor; latitude 06 0 01 1 08.71 11 N; longitude 06 0 22 1 22.92 11 E) comprises seven layers with resistivity values that ranged from 422to 40600 Ωm and depth from 1.2 to 72.4 m. The altitude of this location is 55 m. The deduced lithologies include: lateritic top soil for the first layer; fine grained sand for the second layer; medium to coarse grained sand for the third layer; coarse/gravelly sand for the fourth layer; medium coarse grained sand for the fifth layer; medium grained sand for the sixth layer and fine to medium grained sand for the seventh layer. The potential aquiferous unit\layer delineated lies within the fifth layer with resistivity of 1920 Ωm,depth and thickness of 41.6 m and 77.5 m respectively. VES 11 location (Umusam Quarters, Ejeme Unor; latitude 06 0 00 1 52.70 11 N; longitude 06 0 22 1 19.05 11 E) consists of seven layers with resistivity values which ranged from 653to 88000 Ωm and depth range from 1.2 to 130 m. The altitude of this location is 63 m. The deduced lithlogies include: lateritic top soil for the first layer; fine to medium grained sand for the second layer; coarse grained sand for the third and fourth layers respectively; coarse grained sand for the fourth layer; coarse/gravelly sand for the fifth and sixth layers respectively. The aquiferous unit lies within the sixth layer with resistivity value of 36200 Ωm, depth and thickness of 130 m and 58 m respectively. VES 12 location (Ulogwe Isumpe; latitude 06 0 01 1 18.02 11 N; longitude 06 0 18 1 59.75 11 E) is made up of seven layers with resistivity values that ranged from 217 to 29800 Ωm and depth range from 0.9 to 206 m. This location has an altitude of 102 m. The deduced lithologies include: lateritic top soil for the first layer; fine grained sand for the second layer; fine to medium grained sand for third layer; coarse/gravelly sand for the fourth layer; medium coarse grained sand for the fifth layer; coarse/gravelly sand for the sixth layer and coarse grained sand for the seventh layer. The potential aquiferous zone delineated lies within the fifth layer with resistivity value of 4050 Ωm, depth and thickness of 141 m and 42.6 m respectively. VES 13 location (Dugbo Primary School, Obidugbo; latitude 06 0 03 1 23.58 11 N, longitude 06 0 18 1 29.18 11 E) consists of seven layers with resistivity values that ranged from 398 to 75000 Ωm and depth ranged from 0.8to 162 m. The altitude of this location 88 m. The deduced lithologies include: lateritic top soil for the first layer; fine grained sand for the second layer; fine to medium grained sand for the third layer; medium grained sand for the fourth layer; medium coarse grained sand for the fifth layer; coarse/gravelly sand for the sixth layer and coarse grained sand for the seventh layer. The aquiferous unit delineated lies within the third layer (first aquifer) with resistivity of 288 Ωm,depth and thickness of 7.5 m and 5.0 m respectively and also in the fifth layer (second aquifer) with resistivity of 11000 Ωm and depth of 162 m. VES 14 location (Along Obi Iduhon/Obidugbo road, Obidugbo; latitude 06 0 03 1 39.19 11 N; longitude 06 0 19 1 23.57 11 E) is made up of seven layers with resistivity values that ranged from 156 to 46800 Ωm and depth range from 0.8 to 92.5m. This location has an altitude of 95 m. The deduced lithologies include: lateritic top soil for the first layer, fine-medium grained sand for the second layer; medium- coarse grained sand for the third and the fourth layers respectively; coarse grained sand for the fifth layer; coarse/gravelly sand for the sixth layer and gravelly sand for the seventh layer. The potential aquiferous unit delineated lies within the fourth layer with resistivity of 1120 Ωm,depth and thickness of 31.7 m and 13.3 m respectively. Thus the interpreted geoelectric data correlates with the litho-logic log (Figure 4) of borehole drilled to a depth of 30.1m at Ejeme Aniogor close to VES 1 (DSMWR, 2010). Conclusion: The geoelectric investigation for groundwater prospect, carried out in Ejeme Aniogor and Environs in Aniocha South Local Government Area of Delta State, Nigeria, has provided some insights into the hydrogeology of the area. Based on the main findings of this study, it can be concluded that the aquiferous units in the study area were mostly confined and the results obtained from the study area were found to be consistent with the lithologic log obtained from borehole drilled in the area. Moreso, a generalized depth to the water table could not be deduced for the area because it varied from one locality to another. Hence, the findings showed that the area has good prospects for groundwater development. There is therefore the need to carry out a geoelectric investigation in any locality prior to sinking a borehole in order to forestall loses and to have productive wells. REFERENCES Allen, JRL (1965). Late Quaternary Niger Delta and Adjacent Area.AAPG Bulletin.49(5): 547 600

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor 690 Burke, K; Dessauvagie, TJF; Whiteman, AJ (1972). General History of Benue Valley and Adjacent Areas in: Dessauvagie, TJF, Whiteman, AJ (Eds). African Geology University Press, Ibadan. 206 218 Chinyem, FI (2013). Hydro-geophysical Investigation of Asaba Area, Delta State, Nigeria.Indian Journal of Science and Technology.6(5): 4453 4458 DSMWR, (2010). Delta State Ministry of Water Resources Borehole Lithologic Log, Asaba Freeborn, OE (2006). Geo electric Investigation for Groundwater in Aniocha South Local Government Area, Delta State, Nigeria. Global Journal of Geological Sciences 4(2): 209 219 Goki, NG (2011). Groundwater Monitoring to determine Vulnerability to Man made and Natural Pollutants in the Basement Complex.2Hydro-views 2(1): 89 100 Murat, RC (1970). Stratigraphy and Paeogeography of the Cretaceous and Lower Tertiary in Southwestern Nigeria, In: Dessauvagie, TJF; Whiteman, AJ (Eds). African Geology, University Press, Ibadan, 251 266 Obioha, YE; Nwachukwu, MA (2007). Geologic Problems of Groundwater Development: A case study of Nkwerre and Nwangele Areas in Imo state, Southeastern Nigeria. Water Resources.17: 61 69 Olasehinde, PI (2011). Appropriate Geo exploration Techniques for Groundwater Exploration in Nigeria Basement.Hydro-views.2(1): 67 80 Palacky, GJ; Ritsema, IL; De Jong, SI (1981).Electromagnetic Prospecting for groundwater in Precambrian Terrains in the Republic of Upper Volta. Geophysical Prospecting.29: 932 935 Reyment, RA (1965). Aspects of the Geology of Nigeria. University Press, Ibadan, 145 Schlumberger Services (1986). Schlumberger Log Interpretation Services Manual, 145 Short, KC; Stauble, AJ (1967).Outline of Geology of Niger Delta.AAPG Bulletin.51: 761 799 Zohdy, AAR (1965). The Auxiliary Point Method of Electrical Sounding Interpretation and its Relationship to Dar Zarrouk Parameters.Geophysics.30: 644 650