Virtually Particle-Free Rt -Silica BOND Columns

Similar documents
REFINED RESTEK. Restek s PLOT Column Family The Benchmark For Performance! Visit us at innovative petrochemical solutions

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

GC Columns PLOT Columns

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

REFINED RESTEK. innovative petrochemical solutions. Visit us at Innovative Chromatography Solutions

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

Get Selective. By Jaap de Zeeuw

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

GC Instruments. GC Instruments - Sample Introduction

A New Web-Based Application for Modeling Gas Chromatographic Separations

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Application Note S/SL

Introduction to Capillary GC

Definitive EtG/EtS LC-MS/MS Analysis:

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

CHAPTER 6 GAS CHROMATOGRAPHY

Chapter 27: Gas Chromatography

Activity in the FID Detection Port: A Big Problem if Underestimated

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Petrochemical. Transformer Oil Gas Analysis - TOGA

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Introduction to Capillary GC

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Evaluation of Capillary Columns for General Performance Parameters

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

[ a ppl ic at ion no t e ]

Understanding Gas Chromatography

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Introduction and Principles of Gas Chromatography

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Application Note 032

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Thermo Scientific Prima PRO Process Mass Spectrometer

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Introduction. David B. Wurm, Kefu Sun, and William L. Winniford. Abstract

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Rely on Rxi -PAH Columns

Gas Chromatography. Introduction

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Introduction to Gas Chromatography

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Far UV Absorbance Detector

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

Polymer plants continue to seek ways to increase production and efficiency without compromising safety.

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Making Improvements to Today s Natural Gas Analysis Systems

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Ultra-Inert chemistry for Trace Level Analysis

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Chromatography. Gas Chromatography

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Analysis for Natural Gas and Similar Gaseous Mixtures by Gas Chromatography

Study of Residual Solvents in Various Matrices by Static Headspace

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Basic Principles for Purification Using Supercritical Fluid Chromatography

Chapter 31 Gas Chromatography. Carrier Gas System

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Dimethyl ether (DME) for fuels Determination of impurities Gas chromatographic method

Trajan SGE GC Columns

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Next Generation of Phenyl Columns. Chromatography Products.

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air

Selection of a Capillary GC Column

How To Select the Correct GC Column. Simon Jones Application Engineer

Transcription:

Petrochemical Applications Virtually Particle-Free Rt -Silica BOND s Provide Reliable PLOT Performance With Less Time Lost for Maintenance By Amanda Rigdon, Bill Bromps, Tom Vezza, and Jaap de Zeeuw Optimized manufacturing process practically eliminates particle release, reducing downtime due to system obstructions and damage from particles. Bonded silica stationary phase minimizes impact of water, resulting in reproducible retention times forwater-containing samples. Versatile, highly retentive column ideal for analysis of light hydrocarbons, sulfur gases, halocarbons, and carbon dioxide at temperatures above ambient. Individually QC tested with sensitive unsaturated C probes to ensure consistent selectivity. Porous layer open tubular (PLOT) columns are very useful to GC analysts working on a wide variety of applications, and the unique selectivity of PLOT columns makes them particularly good for separating gaseous compounds without cryogenic cooling. However, the overall utility of traditional PLOT columns is hampered by the characteristic instability of the porous layer that coats the inside of the column. With most PLOT columns, particles that shed from the porous layer create significant problems because they can form obstructions inside the column that can alter flow, causing retention time instability. In addition, particle build-up makes frequent maintenance necessary as jets become obstructed and detectors become contaminated. In contrast, new Rt -Silica BOND columns from Restek are exceptionally robust due to optimized manufacturing and phase bonding steps that practically eliminate particle release. This exceptional stability in combination with high loadability, inertness, and consistent selectivity makes these new columns extremely reliable and ideal for the analysis of light hydrocarbons, sulfur gases, and halocarbons. In addition, carbon dioxide and other permanent gases can be retained at ambient temperature on this silica-based column. This article demonstrates the robustness of the Rt -Silica BOND column and its performance for many of the applications relevant to testing natural gas and light hydrocarbon streams. Virtually Particle-Free and Water Resistant PLOT Performance Restek s proprietary manufacturing technique for the Rt -Silica BOND column results in an extremely stable porous layer with traditional PLOT column loadability and retention without loose particles that can damage valves and foul FID jets. Innovative Chromatography Solutions

Figure shows a magnified picture of three fused silica columns. The middle column is a traditionally-manufactured PLOT column, the bottom column is a wall-coated open tubular column, and the top column is an Rt -Silica BOND PLOT column. Note the uneven layer of particles on the middle column, as well as areas where the particles have completely detached from the column wall; this causes irregularities in the internal diameter of the column that can cause retention time instability. In comparison, the Rt -Silica BOND column looks identical to the wall-coated open tubular column, with no visible shedding of particles or peeling of the coating layer. While the Rt -Silica BOND column does contain a porous layer, the structure of this layer is extremely fine and well-adhered to the column wall, ensuring virtually particle-free operation over the lifetime of the column. Figure : Traditional PLOT columns (middle) have an uneven coating of particles that can shed, fouling instrument parts. Rt -Silica BOND columns (top) have a very fine porous layer with no visible particles and look very similar to wall-coated open tubular columns (bottom). The manufacturing process used to make Rt -Silica BOND columns results in a PLOT column with high selectivity, retention, and capacity without the particle shedding associated with conventional PLOT columns. This provides improved column robustness and less downtime for maintenance. The particle-free nature of this column is evidenced by a particle-generation experiment in which a column was temperature and pressure ramped multiple times. Changes in temperature cause changes in pressure, which result in particle shedding in traditional PLOT columns. Free particles generate large spikes when they hit the flame ionization detector (FID), interfering with quantification. In addition, the particles themselves can obstruct FID jets and damage valves. Note that no large particle spikes were generated when this experiment was carried out on a brand new Rt -Silica BOND column (Figure ).

Figure : The Rt -Silica BOND PLOT column shows no large particle spikes, even with temperature and pressure variation. pa.8.6...0.8.6 0 0 0 0 0 60 GC_PC6 Rt -Silica BOND, 0 m, 0. mm ID (cat.# 98) split (split ratio :) Liner: Sky.0 mm ID straight inlet liner (cat.#.) Inj. Temp.: 0 C Temp.: 0 C to 0 C at C/min (hold min) to 0 C at 0 C/min Carrier Gas He, constant flow Linear Velocity: cm/sec Detector FID @ 60 C Flow Rate: 0 ml/min Type: N Hydrogen flow: 0 ml/min Air flow: 00 ml/min Data Rate: 0 Hz Instrument Agilent 890A GC Another benefit of Restek s proprietary manufacturing process for the Rt -Silica BOND column is that the stationary phase of the column is composed almost entirely of silica. While silica retains water, it does not adsorb it. Some PLOT materials adsorb water, which changes the retention and selectivity of the column. After analyzing samples containing water, these PLOT columns require extensive thermal conditioning (bakeout) to return their original retention and selectivity. Figure shows a mixture of saturated and unsaturated hydrocarbons analyzed on the Rt -Silica BOND column both before exposure to water and then immediately after 0 large volume water injections. Even under these experimental conditions of extreme overwetting, the retention and selectivity of the column remain very similar and under normal use conditions would be effectively identical. This consistent water-resistant performance allows analysts to save time by minimizing maintenance and eliminating the extensive bakeout periods associated with other PLOT columns.

Figure : Repeated water injections have minimal impact on Rt -Silica BOND column selectivity and retention, meaning, water-containing samples can be analyzed without requiring time-consuming thermal reconditioning...... 6.. 8. 9. Methane Ethane Ethylene Acetylene Propane Cyclopropane Propylene Propadiene n-butane tr (min)..6.698.8.0..8.9. 6 0...... 6.. -Butene Methyl acetylene trans--butene,-butadiene Isobutylene cis--butene iso-pentane n-pentane tr (min).8.6.096.6.6..8 6. = Before water injections = After 0 water injections 8 9, 0 6 6 GC_PC Inj. Vol.: Liner: Inj. Temp.: Temp.: Carrier Gas Linear Velocity: Detector Flow Rate: Rt -Silica BOND, 0 m, 0. mm ID (cat.# 98) Custom hydrocarbon gas standard mole percent in nitrogen Type: Hydrogen flow: Air flow: Data Rate: Instrument Notes µl split (split ratio :) Sky mm ID straight inlet liner (cat.#.) 0 C 0 C (hold min) He, constant flow 0 cm/sec FID @ 60 C N 0 ml/min 00 ml/min 0 Hz Agilent 890A GC The hydrocarbon mix was first analyzed to generate a baseline reference; then, ten separate 0 μl injections of water were made minute apart using the same method. After the final water injection, the hydrocarbon mix was analyzed again to compare the chromatography before and after the water injections. 0 ml/min Versatile for Many Applications The new Rt -Silica BOND column combines the retention, capacity, and selectivity of traditional PLOT columns with virtually particle-free, water-resistant performance. The bonded silica surface provides excellent retention for light hydrocarbons (Figure ), permanent gases, and halocarbons, allowing for easy analysis of impurities in light hydrocarbon streams. In addition to light hydrocarbon analysis, the Rt -Silica BOND column is especially selective for sulfur compounds in hydrocarbon streams. Figures and 6 illustrate good separation of sulfur compounds in propane and butane, respectively.

Figure : Saturated and unsaturated hydrocarbons are resolved and retained well on the Rt -Silica BOND column.. Methane. Ethane. Ethylene. Acetylene. Propane 6. Cyclopropane. Propylene 8. Propadiene 9. n-butane 0. -Butene. Methyl acetylene.,-butadiene. trans--butene. Isobutylene. cis--butene 6. Isopentane. n-pentane Rt -Silica BOND, 0 m, 0. mm ID (cat.# 98) Custom DCG gas standard Diluent: Nitrogen mole percent Inj. Vol.: µl split (split ratio :) Liner: mm straight Sky inlet liner (cat.#.) Inj. Temp.: 0 C Temp.: 60 C (hold min) to C at C/min Carrier Gas He, constant flow Flow Rate:. ml/min Detector FID @ 60 C Flow Rate: 0 ml/min Type: N Hydrogen flow: 0 ml/min Air flow: 00 ml/min Data Rate: 0 Hz Instrument Agilent 890A GC GC_PC66 Figure : Sulfur Compounds in Propane Excellent selectivity for sulfurs in hydrocarbon streams!. Carbonyl sulfide. Propane. Hydrogen sulfide. Carbon disulfide. Methyl mercaptan Loop Vol.: 0 µl Inj. Temp.: 0 C Temp.: Rt -Silica BOND, 0 m, 0. mm ID (cat.# 98) 6 ppm in 00% propane sample valve C (hold 8 min) to 00 C at 0 C/min (hold min) Carrier Gas He, constant flow Flow Rate: ml/min Detector PFPD from OI Analytical @ 0 C Element Mode: sulfur Instrument Thermo Trace GC Notes This valve/loop injection employed a split injection technique. Split flow was set to 0 ml/min. Acknowledgement Chromatogram courtesy of Jean-Louis Brix and Joeri Vercammen (Global Analyser Solutions, Belgium).0 0.0.0 0.0.0 GC_PC

Figure 6: Sulfur Compounds in Butane Excellent selectivity for sulfurs in hydrocarbon streams!. Carbonyl sulfide. Hydrogen sulfide. Butane. Carbon disulfide. Methyl mercaptan 6. Ethyl mercaptan. -Propanethiol 6.0 0.0.0 0.0.0 GC_PC Loop Vol.: 0 µl Inj. Temp.: 0 C Temp.: Rt -Silica BOND, 0 m, 0. mm ID (cat.# 98) 6 ppm in 00% butane sample valve 0 C (hold min) to 00 C at 0 C/min (hold 8 min) Carrier Gas He, constant flow Flow Rate: ml/min Detector PFPD from OI Analytical @ 0 C Element Mode: sulfur Instrument Thermo Trace GC Notes This valve/loop injection employed a split injection technique. Split flow was set to 0 ml/min. Acknowledgement Chromatogram courtesy of Jean-Louis Brix and Joeri Vercammen (Global Analyser Solutions, Belgium) Rigorous QC Testing Ensures Ultimate -to- Reproducibility While column-to-column reproducibility is a must for all analysts, it is especially important in valve, backflushing, or columnswitching applications. With this in mind, a special QC test was designed for the Rt -Silica BOND column. Performance parameters, including efficiency, selectivity (RI), retention (k), and inertness are evaluated for each and every column. While the QC tests from some manufacturers include some of these parameters, the compounds used to measure RI are not well-retained and not sensitive to changes in column selectivity. The RI compounds used in the QC test for the Rt -Silica BOND are,-butadiene and methyl acetylene, which are not only very sensitive probes for selectivity, but are of high interest to many analysts. Additionally, while some commercially available PLOT columns are not evaluated for inertness, Rt -Silica BOND column inertness is measured with propylene, which is a more active, unsaturated hydrocarbon. This QC testing ensures the highest level of column-to-column reproducibility available in the industry for PLOT columns. Figure shows QC results from three separate lots of Rt -Silica BOND columns. 6

Figure : Rigorous QC testing ensures column-to-column reproducibility. 6 6 8 9 0 GC_PC. Methane. Propylene. n-butane.,-dichlorotetrafluoroethane (CFC-). Methyl acetylene 6.,-Butadiene. n-pentane Rt -Silica BOND, 0 m, 0. mm ID (cat.# 98) Custom gas standard Diluent: Nitrogen mole percent each component Inj. Vol.: µl split (split ratio :) Liner: Sky.0 mm ID straight inlet liner (cat.#.) Inj. Temp.: 0 C Temp.: 90 C (hold 0 min) Carrier Gas H, constant flow Linear Velocity: 8 cm/sec Detector FID @ 60 C Instrument Agilent/HP6890 GC Conclusion The Rt -Silica BOND column gives you the retention and capacity you need from PLOT columns, along with virtually particle-free and water-resistant operation. The combination of rugged manufacturing and rigorous QC testing ensures every Rt -Silica BOND column will provide optimal performance and reliable results for every analysis, while minimizing downtime due to maintenance from particle shedding or time-consuming bakeouts due to water contamination. The column s unique selectivity makes it ideal for analysis of hydrocarbons, halogenated compounds, and sulfur gases. PATENTS & TRADEMARKS Restek patents and trademarks are the property of Restek Corporation. (See /Patents-Trademarks for full list.) Other trademarks appearing in Restek literature or on its website are the property of their respective owners. The Restek registered trademarks used here are registered in the United States and may also be registered in other countries. Lit. Cat.# PCAR069-UNV 0 Restek Corporation. All rights reserved. Printed in the U.S.A. U.S. 0 Benner Circle Bellefonte, PA 68-8--00-800-6-688 fax: -8--09 China phone: +86-0-69-660 fax: +86-0-8-980 cn.restek.com France phone: + (0) 60 8 0 fax: + (0) 60 8 0 90 www.restek.fr Germany phone: +9 (0)6 9 0 fax: +9 (0)6 9 www.restekgmbh.de Italy phone: +9-0-600 fax: +9-0-00000 www.superchrom.it Japan phone: +8 ()69 00 fax: +8 ()69 00 e-mail: restekjapan@restek.com UK phone: + (0)9 6 fax: + (0)9 6990 www.thamesrestek.co.uk