Artificial Athlete Berlin updated Comments on Function and Use

Similar documents
DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

FIFA Quality Concept for Football Turf. Handbook of Test Methods. January 2008 Edition

This document is a preview generated by EVS

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

FIFA QUALITY CONCEPT. Handbook of Test Methods for Football Turf. March 2006 Edition

PHOENIX CONTACT - 04/2016. Features

VMS-GeoMil. Background

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

Chapter 10: Vibration Isolation of the Source

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Real size experiments of car crash against building column

FAVIMAT (AI)ROBOT2 FAVIGRAPH. Automatic Single-Fibre Testers

HL 3000 / HL 6000 Elastic bearings for high loads made from polyurethane

Lab 11 Simple Harmonic Motion A study of the kind of motion that results from the force applied to an object by a spring

(Refer Slide Time: 1: 19)

Chapter 23: Principles of Passive Vibration Control: Design of absorber

Chapter 7 Vibration Measurement and Applications

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Displacement at very low frequencies produces very low accelerations since:

ISO INTERNATIONAL STANDARD

Chapter 14 Oscillations. Copyright 2009 Pearson Education, Inc.

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

Mechanical Shock Testing for LIGA Materials Characterization

Page AC : INSTRUMENTATION FOR SHOCK AND IMPACT ANALYSIS

Analysis and Experiments of the Linear Electrical Generator in Wave Energy Farm utilizing Resonance Power Buoy System

Chapter 3. Experimentation and Data Acquisition

Drop towers and fitness flooring assemblies

Use of reciprocity calibrated accelerometer standards for performing routine laboratory comparison calibrations. Technical paper 226

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

+ + ( indicator ) + (display, printer, memory)

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

G r a d e 1 1 P h y s i c s ( 3 0 s ) Final Practice exam

Part 2: Methods for special reverberation test rooms

Wireless Weather Station. Instruction Manual

ISO Radiological protection Sealed radioactive sources General requirements and classification

Chapter a. Spring constant, k : The change in the force per unit length change of the spring. b. Coefficient of subgrade reaction, k:

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Shock attenuation properties of sports surfaces with twodimensional

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

System Parameter Identification for Uncertain Two Degree of Freedom Vibration System

Standard Practices for Air Speed Calibration Testing

SEISMIC BASE ISOLATION

2.003 Engineering Dynamics Problem Set 10 with answer to the concept questions

EXPERIMENTAL DETERMINATION OF DYNAMIC CHARACTERISTICS OF STRUCTURES

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Simple Harmonic Motion Test Tuesday 11/7

NUCLEAR MAGNETIC RESONANCE. The phenomenon of nuclear magnetic resonance will be used to study magnetic moments of nuclei.

Review of Anemometer Calibration Standards

Measurement Techniques for Engineers. Motion and Vibration Measurement

ISO INTERNATIONAL STANDARD

Development of a diagnosis technique for failures of V-belts by a cross-spectrum method and a discriminant function approach

INVESTIGATION OF IMPACT HAMMER CALIBRATIONS

ScienceDirect. Response Spectrum Analysis of Printed Circuit Boards subjected to Shock Loads

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Vibration modelling of machine tool structures

Theory and Design for Mechanical Measurements

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

Available online at Procedia Engineering 200 (2010) (2009)

SURFACE BARKHAUSEN NOISE INVESTIGATIONS OF STRESS AND LEAKAGE FLUX

Study of Rupture Directivity in a Foam Rubber Physical Model

Lecture 9: Harmonic Loads (Con t)

Structural Dynamic Behavior of a High-Speed Milling Machine

INTERNATIONAL STANDARD

Analysis of the NOT Primary Mirror Dynamics

Dynamic Analysis on Vibration Isolation of Hypersonic Vehicle Internal Systems

ISO INTERNATIONAL STANDARD. Plastics Determination of hardness Part 1: Ball indentation method

DC/DC regulator Input V Output up to 16 A

Magnetic Measurements

LABORATORY VII MECHANICAL OSCILLATIONS

Damage detection of shear connectors in composite bridges under operational conditions

Regupol. Vibration

CONTRIBUTION TO THE IDENTIFICATION OF THE DYNAMIC BEHAVIOUR OF FLOATING HARBOUR SYSTEMS USING FREQUENCY DOMAIN DECOMPOSITION

25/01/2013. Agenda. Advanced Approaches to Modeling and Assessment of Floors for Control of Human Activity. Ultra-Low Vibration Environments

Chapter 14 Oscillations. Copyright 2009 Pearson Education, Inc.

Address for Correspondence

Regufoam. Vibration 270 Plus.

Provläsningsexemplar / Preview TECHNICAL REPORT INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE

Acceleration levels of dropped objects. Technical paper 321

Operating Instructions for Digital Manometer. Model: MAN-SD

UNCERTAINTY IN TORQUE CALIBRATION USING VERTICAL TORQUE AXIS ARRANGEMENT AND SYMMETRICAL TWO FORCE MEASUREMENT

White Paper. Moisture Analyzer Routine Testing

Transactions on the Built Environment vol 22, 1996 WIT Press, ISSN

THERMAL FIELD ANALYSIS IN DESIGN AND MANUFACTURING OF A PERMANENT MAGNET LINEAR SYNCHRONOUS MOTOR

Chapter 14 Oscillations

Design against fluctuating load

Vibration Testing. an excitation source a device to measure the response a digital signal processor to analyze the system response

Unit 2: Simple Harmonic Motion (SHM)

LECTURE 3 CMOS PHASE LOCKED LOOPS

Grandstand Terraces. Experimental and Computational Modal Analysis. John N Karadelis

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

CONSIDERATIONS ON THE NON-LINEAR MODELLING OF THE DYNAMICS OF THE VIBRATION AND SHOCK ISOLATORS MADE FROM COMPOSITE NEOPRENE

Chapter 14 Oscillations

50kNm TORQUE STANDARD MACHINE

Damping of materials and members in structures

Computer Aided Design of Tine of Tuning Fork Densitometer Shuang LIU, Xin-sheng CHE *, Yi-shun ZHANG and Xin-yu-han JI

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION

ISO INTERNATIONAL STANDARD

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

Vibration Testing. Typically either instrumented hammers or shakers are used.

Transcription:

Home Publications Artificial Athlete Berlin updated 12.2.2000 Comments on Function and Use by H.J. Kolitzus These comments were prepared as an addition to Mark Harrison s extensive study on Factors Affecting the Results of the Berlin Artificial Athlete Shock Absorption Test (9/99). The following comments are issued in cooperation with Bernd Härting (IST Leipzig). 1. Scope of Test The test was developed by FMPA-Baden-Württemberg (Otto-Graf- Institut) in Germany during 1976 as a piece of sponsored research initiated by the Bundesinstitut für Sportwissenschaft (Federal Institute of Sports Sciences BISp) in Cologne. It was designed to test the give of sports surfaces in-situ/on-site. The test was first specified in the German standard DIN 18032-2 "Sports Halls; Sports Surfaces; Requirements and Testing". The test was then incorporated into DIN 18035-6 "Sports Grounds; Synthetic Surfaces; Requirements, Testing, Maintenance" (playing areas) and DIN 18035-7 "Sports Grounds; Synthetic Turf Areas", DIN 7926 Part 1 "Equipment for Children Playgrounds". The following international documents include this test: IAAF Performance Specifications for Synthetic Surfaced Athletics Tracks (Outdoor) and the FIH Handbook for Synthetic Hockey Pitches Outdoor. There are 2 variants of the test procedure: the first filters the signal with a cut-off frequency of 120Hz (DIN 18032-2) and the second filters with 220Hz (DIN 18035-6). The reasons for the different filters are given in a later section of this paper. The test procedure has been subjected to various changes over the time which, did not change the test, but improved the http://www.isss.de/publications/artificialathlete/athlete2.html (1 of 11)11/01/2007 20:15:59

accuracy. The most important innovation was the new triple-coil milled spring. Its spring number is manufactured to an accuracy of 2'000 MN/m +/- 0.050. The other major improvement is the digital data acquisition technique (A/D converter and computer driven data acquisition and recording). 2. General Structure and Function The structure of the test apparatus and the test procedure are described in DIN 18032-2 (current version 1986/1991). If the AA Berlin is used on a concrete floor, it can be regarded a simple single-mass swinger. Based on M. Harrison s formulas the impact approximates the equation: y = (x M. g / k). sin (w. t) + M. g / k where y = deformation of spring in m x = maximum compression of the spring = 0.00338m g = natural acceleration due to gravity = 9.81m/s 2 M = mass of drop weight = 20.0kg k = spring constant = 2.0 MN/m t = time in seconds w = expresses resonance frequency = Ö k / M = 316 f r = resonance frequency = w / (2. p ) = 50Hz v = -(0.00338 M. g / k). w. cos( w. t) t = 0 --> v 0 = 1.04 m/s F = y. k http://www.isss.de/publications/artificialathlete/athlete2.html (2 of 11)11/01/2007 20:15:59

F max = x. k = 6760N However, in normal usage, the Artificial Athlete is a two-mass swinger. If the Artificial Athlete rests upon a soft sports surface (Force Reduction > 50%), the lower mass starts a vibration with a resonance frequency considerably higher than the resonance frequency of the 1-mass swinger (see figure 1). Based on experiments upon various soft sports surfaces including the ReferenceNormals, it can be shown that the frequency of the superposed oscillation is in the range of 130Hz to 230Hz. While rather independant of the softness of the 'sports surface', this is dependant on the individual mechanical test device used (information gained by measuring the time of full cycles of the superposed oscillation on the graph). The frequency of the basic test signal decreases to values below 20Hz because of the softness of the 'sport surface'. The softer the 'sports surface' the larger the amplitude of the superposed oscillation. This may result in a difference of Force Reduction of more than 10% of the absolute value (evaluation with unfiltered signal compared with the 120Hz filtered signal). According to the latest specification of DIN 18032-2, the mass of the lower mass should be 3kg. The resonance frequency of the lower mass with the spring of the Artificial Athlete would then be 130Hz. It becomes higher the lower the mass. The reasoning for the size of the amplitude in dependance to the softness and the damping chacteristics of the 'sport surface', is derived from the solution of the differential equations of the 2- mass swinger (performed at FMPA in the 70's; not available anymore; see also G. Pratt's study). The superposed oscillation must be eliminated from the signal, which is the information that the test was designed to produce. This is achieved by use of a low pass filter with a cut-off frequency of 120Hz. According to DIN 18032-2, this applies to sports hall surfaces only. Other soft surfaces such as synthetic turf surfaces and playground surfaces are to be treated according to type (see DIN standards). If the lower mass is neglected (for reasons of simplification) the effective spring number/constant/rate k of the combined system Artificial Athlete + sports surface is as follows http://www.isss.de/publications/artificialathlete/athlete2.html (3 of 11)11/01/2007 20:15:59

1 / k = 1 / k 1 + 1 / k 2 where k 1 spring rate of the AA k 2 spring rate of sports surface (assumed to be a constant) if k 2 is set to k 2 = f. k 1 then k = k 1. f / ( 1 + f ) Inserting this in FR = 1 F ss / F concrete gives FR = 1 SQRT{ f / ( 1 + f ) } This function is displayed in figure 2. It can be seen that the Force Reduction is 30% when the spring rate of the sports surface is equal to the AA s spring rate (f=1). The Force Reduction is about 10% when the sports surface is 5-times stiffer than the AA s spring. 3. Measuring Technique It is assumed that digital measuring technique is standard today (analog signal acquisition and digital signal processing). Load Cell The load cell needed for the test is specified in DIN 18032-2. No further comment is necessary. With the low frequencies of all situations occurring on sports surfaces, it does not matter whether it is a strain gage or piezo-electric system (was critical in 1976 when this was a question of confession). However, the http://www.isss.de/publications/artificialathlete/athlete2.html (4 of 11)11/01/2007 20:15:59

give of a strain gauge load cell has to be taken into account ( spring rate may be in the range of 50'000 to 100'000 N/mm). Amplifier / Signal Conditioner The capacity of the signal conditioner is also specified in DIN 18032-2. It should have a linear signal transmission with a minimum of 1kHz (-3dB). With commercial equipment from qualified manufacturers this is no problem. Amplifiers normally have a built-in filter in order to eliminate noise from the signal (for instance 500Hz Butterworth 2-pole). A/D Converter The DIN did not anticipate that measurements would be performed with digital data acquisition systems. Today, this is regarded the standard in measuring technology. A/D converters with 12bit capability meet the needs of the test. The number of conversions per second needed is easily performed by modern ADCs. Recording Signals from the AA Berlin should be processed with a computer. The signal should be displayed on a screen to visually check its regularity. Then, it should be processed and evaluated to be read as Force Reduction. Filtering Filtering of the signal is needed for two reasons: first, the high frequent vibration or noise of the metal parts of the Artificial Athlete (undamped impact of the metal drop weight onto the metal spring) and secondly, the superposed oscillation of the lower mass of the Artificial Athlete. The first aspect is covered with any 500Hz (minimum) low pass filter. The second aspect is addressed with additional filtering of a 120Hz filter of Butterworth characteristic with 9 poles or equivalent. A 2-pole Butterworth filter does not have a sharp enough separation capability to completely eliminate the superposed/parasitic oscillation. When using a computer, a data acquisition programme such as EASYEST, TESTPOINT or the like is needed. The TESTPOINT programme contains a filter module emulating a Butterworth filter with x poles. It can be applied to transient and continuous http://www.isss.de/publications/artificialathlete/athlete2.html (5 of 11)11/01/2007 20:15:59

signals. The filtered signal exhibits a considerable time lag and a slight overswing compared with the original signal (i.e. peak force of filtered signal is slightly larger than the unfiltered ideal curve). In the past (and still valid for EASYEST users) only FFT based filtering was available with these programmes. It was necessary then to adjust the FFT based filtering to the Butterworth filter. Since very little information on digital filtering is available, this task must be performed by practical determination of the frequency response of the filter system. It was found that the steepness of the filter function beyond the cut-off frequency is influenced by the sampling rate in relationship to the cut-off frequency. For a cut-off frequency of 120 Hz, the sampling rate must not be higher than 2000Hz with the EASYEST programme. When this rule is violated in TESTPOINT, no filtering effect occurs at all. FFT filter can be applied to transient signals only (number of points must always be a power of two). There is no time lag between the filtered and the unfiltered signal and no overswing. It is an error to believe that the 130Hz 230Hz oscillations are created by internal 'problems' of the Butterworth filter (i.e. selforiginated by the filter modul) as stated in the DIN 18032-2 committee. Evaluation The evaluation of Force Reduction is easy if springs comply with the current level of accuracy available today (see above). No corrective term is then necessary as is found in the 1986/1991 version of DIN 18032-2. 4. Precision Error Considerations It is of major importance to know about the possible errors and their effects on the results (i.e. Force Reduction). Reference Peak Value (1) Mark Harrison's study deals with the factors influencing the peak force of the Artificial Athlete Berlin on concrete. If the accuracy of the drop weight and the drop height are within specification, the peak force will not vary more than +/- 15N. If the spring http://www.isss.de/publications/artificialathlete/athlete2.html (6 of 11)11/01/2007 20:15:59

constant deviates by 40N/mm the peak force error is 65N. It is important to specifiy how the peak force on concrete is to be determined. Experimental data shows that using a 120Hz FFT or Butterworth filter with 2 poles disfigures the result by a few percent. Not using any filtration leads to an incidental result since the high frequent vibration is not repeatable/consistant from impact to impact and from test device to test device. However, a sufficient repeatability is achieved by applying a min. 220Hz filter (see Mark Harrison s study). The quality of the concrete base is less important than believed by some labs. To recognize whether a concrete base or floor is suitable, it is necessary only to examine the concrete surface after the tests. If there is any damage the surface is not suitable. Placing a steel panel/plate on the concrete surface, to harden and reinforce it, helps to eliminate the possiblity of a problem with the concrete base. If the effective mass of a concrete base in the lab is not known, the usability of the base can be determined by comparison tests with the AA on a concrete base with known mass. Reference Peak Value (2) What happens if the peak force value is mistaken in the formula to evaluate FR? The formula is FR = 1 F ss / F concrete and FR = 1 F ss / F concrete where FR = correct Force Reduction F ss = peak force on sport surface F concrete = peak force on concrete x = the error factor and F concrete = the erroneous peak force on concrete and FR = the erroneous Force Reduction Then the error function is FR = 1 ( 1 FR ). x http://www.isss.de/publications/artificialathlete/athlete2.html (7 of 11)11/01/2007 20:15:59

With F concrete = x. F concrete With the same magnitude of the error factor x the error in FR increases dramatically the lower FR (see figure 3) Peak Force on Sports Surface A similar consideration can be applied to the case that F ss is determined with an error. FR = 1 F ss / F concrete FR = 1 F ss / F concrete F ss = y. F ss FR = ( y 1 + FR) / y With the same magnitude of the error factor y the error of FR increases dramatically the lower FR (see figure 4). Spring Constant One of the most interesting factors is the effect from deviations in the spring constant beyond the specified range. In order to understand the problem in principle, the simplified Artificial Athlete (i.e. no lower mass) is used. The incorrect spring constant is K = z. K With this, the formula of paragraph 4.1.4 is modified as follows (see figure 5) (formula has still to be verified): Improvements FR = 1 SQRT{ z. f / ( 1 + f ) } http://www.isss.de/publications/artificialathlete/athlete2.html (8 of 11)11/01/2007 20:15:59

Aside of calibration, it is necessary to have a method to regulate all members of the measuring chain and to have a method to control the compliant functions of the various test devices. In the past, this was often achieved by using samples of sports surfaces which were circulated between the test labs. Since real surface samples are not constant over the time another method was developed by SKZ. The surface replacement called ReferenceNormals - consists of from 3 to 6 washer springs of specified characteristics mounted in a metal cache. The ReferenceNormals are manufactured and 'calibrated' by SKZ. To date, only one specific grade has been created: FR = about 53%. The calibration is performed by comparing a new ReferenceNormal with an Ancester-ReferenceNormal the Force Reduction of which was determined within a Round Robin in Germany. The ReferenceNormal method is included in the 1998 draft of DIN 18032-2 as a calibration method which is believed to eliminate all problems with excessive peak force values on concrete or deliberate use of filters. With the ReferenceNormal, the results of inaccurately functioning AAs are corrected by using an additive term: the difference between the nominal Force Reduction of the ReferenceNormal and the actually measured FR with the device to be calibrated determines the additive parameter: FR = (1 F ss / F concrete ) +? FR The specification of the ReferenceNormal in DIN 18032-2:1998 is incomplete. In practice, however, the method is very helpful since the ReferenceNormal is an easy and reliable means of controlling the accurate operation of the test equipment. The IST has retested its ReferenceNormal 5-times since 1998. The results varied within 0.4%. The DIN must be amended with an acceptable calibration procedure for the ReferenceNormal. The ReferenceNormal can be designed with various grades of softness in order to simulate 30%, 50% and 60% Force Reduction. 5. Practical Consequences Design of Test Apparatus Mechanically, the most important aspect of the Artificial Athlete is the assurance that a minimum level of friction occurs in its moving parts. The friction of the drop weight against the guiding rods is minimized by using teflon-covered tubes 1mm larger in http://www.isss.de/publications/artificialathlete/athlete2.html (9 of 11)11/01/2007 20:15:59

diameter than the rods. Unfortunately, this is not mentioned in DIN 18032-2. DIN 18032-2 does not require the new triple-coil milled spring, (Rein spring named for its developer and manufacturer, the Rein Company in Urach, Germany). The DIN requires only a spring with a static spring constant of 2000MN/m +/- 0.060 and linear characteristic of up to 10kN. This requirement may be met by springs of classic style (singlecoil, bent). However, springs of this type cannot be manufactured to anywhere near the same accuracy. Springs consisting of a package of single springs are problematic since the accuracy of the individual springs, especially their length, is low (taken from engine valves). They have to be prestressed in order to avoid an undefined start section of the loaddeformation characteristic. Such springs need special investigation in order to be sure of getting correct results. Measuring Technique The measuring chain shall consist of commercially designed and manufactured elements from established manufacturers/ suppliers only. All relevant technical data must be available. The amplifier must transmit signals up to 1kHz (3dB). The measuring chain shall include a visual check of the signal (display on computer screen or transient oscilloscope). Calibration The calibration should be performed in two different ways. First, all components of the measuring chain must be checked and adjusted/calibrated according to established rules of measuring technology. Each component must meet the requirements. Verification of the frequency response of the filter modul needs to be conducted. The frequency response must comply with a Butterworth 9-pole filter characteristic. http://www.isss.de/publications/artificialathlete/athlete2.html (10 of 11)11/01/2007 20:15:59

To calibrate the AA, a frequency response diagram must be established using the specific measuring chain. The peak force on concrete must comply with the range of 6.4kN to 6.7kN using a 220Hz 500Hz filter or equivalent. The spring needs static calibration using an appropriate calibration device (see figure 6). Second: the measuring chain including the mechanical parts must be checked with a ReferenceNormal. However, the physically correct method must still be developed (see paper Artificial Athlete Berlin: Operating the ReferenceNormal Right ). The calibration of the ReferenceNormal can be achieved by using specific ISSS owned devices which are regularly circulated among ISSS members. The average of 4 labs (minimum) with compliant results is critical to this procedure. An individual test device needs correction if it differs by more than 0.5% from the assigned/nominal true value of the ReferenceNormal. International Association for Sports Surface Sciences 8264 Eschenz / Switzerland, Hauptstr. 34, Tel. +41-52-740 3005, Fax +41-52-740 3009 e mail: Info@isss.de members area (password protected) last updated December 2003 site comments http://www.isss.de/publications/artificialathlete/athlete2.html (11 of 11)11/01/2007 20:15:59