The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

Similar documents
Bromine 10 T mg/l Br 2 DPD

Phosphate HR T 1-80 mg/l P Vanadomolybdate

Phosphate total HR TT mg/l P b) Phosphomolybdenum Blue

Phosphate total LR TT mg/l P b) Phosphomolybdenum Blue

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

Nitrogen total LR VARIO TT mg/l N b) Persulphate Digestion

DULCOTEST DT1B Photometer

DPD Test N Tube Method *

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Photometer AL250. Scroll Memory (SM) N.I.S.T Traceability. Highlights

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

Instruction Manual. Waterproof Portable Colorimeter C401 / 301 / 201 / 101 / 102 / 103 / 104 / 105. Part of Thermo Fisher Scientific

Chlorine, Free and Total, High Range

Chlorine, Free and Total, High Range

Chlorine, Free and Total, Low Range

CHLORINE, TOTAL (0 to 4.00 mg/l)

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

SC450. Single Parameter Colorimeter Chlorine & ph. Bedienungsanleitung Seite Instruction Manual Page Mode d'emploi Page 39 55

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

Peracetic Acid (PAA) and Hydrogen Peroxide (H 2 O 2 )

Exercise 6: Determination of Hardness of Water

Chematest 25. Operator s Manual A Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland ANALYTICAL INSTRUMENTS

Parameter Method Range # of Tests Code Page. Acidity (as % Oleic acid) titration % acidity 6 HI

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

Reagents for Chemical Test Kits

Cuvette Test LCK 381 TOC Total organic carbon

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

SILICA, Low Range (0 to 1.60 mg/l)

Method to 0.50 mg/l NH 3 N Powder Pillows

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ )

Method to 0.50 mg/l NH 3 N Powder Pillows

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Sodium Chloride - Analytical Standard

Chloramine (Mono) and Nitrogen, Free Ammonia

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

NITROGEN, AMMONIA, High Range, Test N Tube

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

NITROGEN, TOTAL, HR, Test N Tube

Persulfate Digestion Method Method to 40 mg/l N (HR) TNTplus 827

DR/4000 PROCEDURE. IRON, Total

Trihalomethane Formation Potential (THMFP)

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

ENVIRONMENT AGENCY. Chemical disinfecting agents in waters and effluents (2008) Methods for the Examination of Waters and Associated Materials

Understanding Chlorine Measurement. Rebecca Luedee Environmental Sales

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

PRELIMINARY ACTIVITY FOR

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

SMART Spectro. L Mott TEST INSTRUCTIONS. v MN. Spectro pho to m eter

Mercaptoacetic Acid Method*

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

Instruction Manual C401/301/201/102/101. Portable Colorimeter. 99 Washington Street Melrose, MA Phone Toll Free

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows

NITROGEN, TOTAL, Test N Tube * Method 10071

DR/4000 PROCEDURE NITRATE. 2. The display will show:

LOW-RANGE TOTAL CHLORINE

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Application Note #119 Alkalinity and Chloride by Titration

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Photometer-System MD100

Manganese III Digestion Method * (with chloride removal)

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Oxygen Demand, Chemical

For Research Use Only

Experiment 8 Introduction to Volumetric Techniques I. Objectives

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

METHOD STATEMENT. Determinand: Ammonia, Chloride, Nitrate, Nitrite, Orthophosphate, Sulphate & TON. Matrix: Leachates, effluents and wastewaters

Chapter 6 TABLE OF CONTENTS. Chlorine Residual Determination. Section 1: General Section 2: Introduction to Chlorine... 3

INORGANIC CHEMISTRY (LAB MANUAL)

Determination of Orthophosphate Ion

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Oxygen Demand, Chemical

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

burette filled with sulphuric acid conical flask 25.0 cm 3 of sodium hydroxide(aq) concentration 2.24 mol / dm 3

Quaternary Ammonium Compounds

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Isotope: An atom of an element that has the same number of protons as the element, but different numbers of neutrons.

INTERNATIONAL STANDARD

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

CEE 684 (697K) Dichloropropanone Lab

BCA Protein Macro Assay Kit

The content of this operation manual is protected by copyright laws. No part of this operation manual may be reproduced in any form.

Suggested answers to in-text activities and unit-end exercises. Topic 16 Unit 55

DETERMINATION OF CHEMICAL OXYGEN DEMAND COD

Transcription:

Chlorine L a) 0.02-4.0 mg/l Cl 2 DPD 101 CL6 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Instrument Type Cuvette λ Measuring Range MD 100, MD 110, MD 200, ø 24 mm 530 nm a) 0.02-4.0 mg/l Cl 2 MD 600, MD 610, MD 640, MultiDirect, PM 620, PM 630 SpectroDirect, XD 7000, XD 7500 ø 24 mm 510 nm a) 0.02-3 mg/l Cl 2 Material Required material (partly optional): Reagents Packaging Unit Part Number DPD 1 Buffer Solution, Blue Bottle Liquid / 15 ml 471010 DPD 1 Buffer Solution Liquid / 100 ml 471011 DPD 1 Buffer Solution 1 Set 471016 DPD 1 Reagent Solution, Green Bottle Liquid / 15 ml 471020 DPD 1 Reagent Solution Liquid / 100 ml 471021 DPD 1 Reagent Solution 1 Set 471026 DPD 3 Solution, Red Bottle Liquid / 15 ml 471030 DPD 3 Solution Liquid / 100 ml 471031 DPD 3 Solution 1 Set 471036 DPD Reagent Set 1 Set 471056 Application List Waste Water Treatment Disinfection Control Boiler Water Cooling Water Raw Water Treatment Pool Water Control NL EN Handboek Handbook van of Methoden Methods 05/18

Pool Water Treatment Drinking Water Treatment Sampling 1. When preparing the sample, Chlorine outgassing, e.g. through the pipette or shaking, must be avoided. 2. The analysis must take place immediately after taking the sample. Preperation 1. Cleaning of vials: As many household cleaners (e.g. dishwasher detergent) contain reducing substances, this can lead to lower results with the determination of Chlorine. To avoid measurement errors, the glassware used should be free of chlorine consumption. To achieve this, all glassware should be placed in a sodium hypochlorite solution (0.1 g/l) for one hour and then rinsed thoroughly with deionised water. 2. For individual testing of free and total Chlorine, the use of different sets of glassware is recommended (EN ISO 7393-2, 5.3) 3. The DPD colour development is carried out at a ph value of 6.2 to 6.5. The reagents therefore contain a buffer for the ph adjustment. Strong alkaline or acidic water samples must therefore be adjusted between ph 6 and ph 7 before the analysis (use 0.5 mol/l Sulphuric acid or 1 mol/l Sodium hydroxide). Notes 1. After use, ensure the cuvettes are once again closed with the respective samecoloured screw caps. 2. Reagent sets are to be stored in the cool at +6 C to +10 C. NL EN Handboek Handbook van of Methods Methoden 05/18 05/18

Implementation of the provision free chlorine with liquid reagent Select the method on the device In addition, choose the test: free For this method, no ZERO measurements are to be carried out with the following devices: XD 7000, XD 7500 10 ml Fill 24 mm vial with 10 ml sample. Zero Press the ZERO button. Remove the vial from the sample chamber. For devices that require no ZERO measurement, start here. Empty vial. 6 2 Hold cuvettes vertically and add equal drops by pressing slowly. Add 6 drops DPD 1 Buffer Add 2 drops DPD 1 Reagent NL EN Handboek Handbook van of Methoden Methods 05/18

Fill up vial with sample to the 10 ml mark. Invert several times to mix the contents. Test Press the TEST (XD: START) button. The result in mg/l free chlorine appears on the display. NL EN Handboek Handbook van of Methods Methoden 05/18 05/18

Implementation of the provision totale Chlorine with liquid reagent Select the method on the device In addition, choose the test: total For this method, no ZERO measurements are to be carried out with the following devices: XD 7000, XD 7500 10 ml Fill 24 mm vial with 10 ml sample. Zero Press the ZERO button. Remove the vial from the sample chamber. For devices that require no ZERO measurement, start here. Empty vial. 6 2 Hold cuvettes vertically and add equal drops by pressing slowly. Add 6 drops DPD 1 Buffer Add 2 drops DPD 1 Reagent NL EN Handboek Handbook van of Methoden Methods 05/18

3 Add 3 drops DPD 3 Fill up vial with sample to the 10 ml mark. Test Invert several times to mix the contents. 2 min Press the TEST (XD: START) button. 10 11 12 1 2 9 3 8 7 6 5 4 Wait for 2 minute(s) reaction time. Once the reaction period is finished, the measurement takes place automatically. The result in mg/l total Chlorine appears on the display. NL EN Handboek Handbook van of Methods Methoden 05/18 05/18

Implementation of the provision Chlorine differentiated with liquid reagent Select the method on the device In addition, choose the test: differentiated For this method, no ZERO measurements are to be carried out with the following devices: XD 7000, XD 7500 10 ml Fill 24 mm vial with 10 ml sample. Zero Press the ZERO button. Remove the vial from the sample chamber. For devices that require no ZERO measurement, start here. Empty vial. 6 2 Hold cuvettes vertically and add equal drops by pressing slowly. Add 6 drops DPD 1 Buffer Add 2 drops DPD 1 Reagent NL EN Handboek Handbook van of Methoden Methods 05/18

Fill up vial with sample to the 10 ml mark. Invert several times to mix the contents. Test 3 Press the TEST (XD: START) button. Remove the vial from the sample chamber. Add 3 drops DPD 3 Invert several times to mix the contents. NL EN Handboek Handbook van of Methods Methoden 05/18 05/18

2 min Test 10 11 12 1 2 9 3 8 4 7 6 5 Press the TEST (XD: START) button. Wait for 2 minute(s) reaction time. Once the reaction period is finished, the measurement takes place automatically. The result in mg/l free chlorine, mg/l gebundenes Chor, mg/l total chlorine appears on the display. NL EN Handboek Handbook van of Methoden Methods 05/18

Chemical Method DPD Appendix Interferences Persistant Interferences All oxidising agents in the samples react like chlorine, which leads to higher results. Removeable Interferences Interference from Copper and Iron (III) are eliminated by the addition of EDTA. Concentrations above 4 mg/l Chlorine, in the event of using fluid reagents, can lead to results within the measuring range of up to 0 mg/l. In this case, the sample must be diluted with chlorine-free water. 10 ml of the diluted sample should be mixed with the reagent and the measurement taken again (plausibility test). Interference from / [mg/l] CrO 4 2-0.03 MnO 2 0,03 Conformity EN ISO 7393-2 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code 19 20 75) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1/No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # including stirring rod, 10 cm NL EN Handboek Handbook van of Methods Methoden 05/18 05/18