Caustic Dissolution of Chromium Compounds Present in Hanford Tanks

Similar documents
Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA

The Dissolution of Natural Autunite as a Function of Aqueous Bicarbonate

Plasma Response Control Using Advanced Feedback Techniques

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

APPLICATION SINGLE ION ACTIVITY COEFFICIENTS TO DETERMINE SOLVENT EXTRACTION MECHANISM FOR COMPONENTS OF NUCLEAR WASTE

ION EXCHANGE SEPARATION OF PLUTONIUM AND GALLIUM (1) Resource and Inventory Requirements, (2) Waste, Emissions, and Effluent, and (3) Facility Size

ions which are abundant in waste water. Since zeolites are

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

ASTER CONF-~W OSTI MAY DISTRIBUTION OF THIS

Development of a High Intensity EBIT for Basic and Applied Science

(4) How do you develop an optimal signal detection technique from the knowledge of

GA A22689 SLOW LINER FUSION

FUSION TECHNOLOGY INSTITUTE

GA A27806 TURBULENCE BEHAVIOR AND TRANSPORT RESPONSE APPROACHING BURNING PLASMA RELEVANT PARAMETERS

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

BASAL CAMBRIAN BASELINE GEOLOGICAL CHARACTERIZATION COMPLETED

TECHNICAL PROGRESS REPORT. Date submitted: January 18, Principal Investigators: Leonel E. Lagos, Ph.D., PMP David Roelant, Ph.D.

Final Technical Report. Department of Energy. for

Tank 31H Saltcake Dissolution Tests

Abstract of paper proposed for the American Nuclear Society 1997 Winter Meeting Albuquerque, New Mexico November 16-20, 1997

Fission-Fusion Neutron Source

Prevention of Solids Formation

Alex Dombos Michigan State University Nuclear and Particle Physics

C o f l F - 9m307-- SPREADSHEET APPLICATION TO CLASSIFY RADIOACTIVE MATERIAL FOR SHIPMENTa. A. N. Brown

Analysis of Shane Telescope Aberration and After Collimation

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

The Radiological Hazard of Plutonium Isotopes and Specific Plutonium Mixtures

AC dipole based optics measurement and correction at RHIC

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

The Graphite Isotope Ratio Method (GIRM): A Plutonium Production Verification Tool

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

Novel Ceramic Membrane for High Temperature Carbon Dioxide Separation

THE DISCOVERY OF FULLERENES IN THE 1.85 BILLION-YEAR-OLD

DETECTING AND QUANTIFYING LEWISITE DEGRADATION PRODUCTS I N ENVIRONMENTAL SAMPLES USING ARSENIC SPECIATION*

PLASMA MASS DENSITY, SPECIES MIX AND FLUCTUATION DIAGNOSTICS USING FAST ALFVEN WAVE

&OAE- 9b I 0 IS& - - I Determination of Plutonium in Urine: Evaluation of Electrothermal Vaporization Inductively Coupled Plasma Mass Spectroscopy.

INTERMOLECULAR POTENTIAL FUNCTIONS AND HIGH RESOLUTION MOLECULAR SPECTROSCOPY OF WEAKLY BOUND COMPLEXES. Final Progress Report

Hanford Tank Waste Chemistry

GA A23713 RECENT ECCD EXPERIMENTAL STUDIES ON DIII D

Excitations of the transversely polarized spin density. waves in chromium. E3-r 1s

GA A25853 FAST ION REDISTRIBUTION AND IMPLICATIONS FOR THE HYBRID REGIME

Sodium Hydroxide Extraction From Caustic Leaching Solutions

Magnetic Measurements of the Elliptical Multipole Wiggler Prototype

GA A26474 SYNERGY IN TWO-FREQUENCY FAST WAVE CYCLOTRON HARMONIC ABSORPTION IN DIII-D

Development of a Parallel, 3D, Lattice Boltzmann Method CFD Solver for Simulation of Turbulent Reactor Flow

Three-Dimensional Silicon Photonic Crystals

Novel Nanoparticles for Ultrasensitive Detection and Spectroscopy

PRECISION STUDIES OF NUCLEI

Parametric Instabilities in Laser/Matter Interaction: From Noise Levels to Relativistic Regimes

9 7og$y4- International Conference On Neutron Scattering, Toronto August Spin Dynamics of the reentrant spin glass Fe0.7A10.3.

Ch. 4 In-Class Exercise. sodium chloride, glucose, ethanol, lead nitrate, sucrose, methanol

Tell uric prof i 1 es across the Darrough Known Geothermal Resource Area, Nevada. Harold Kaufniann. Open-file Report No.

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

UNIT OPERATIONS AND CHEMICAL PROCESSES. Alan M. Krichinsky

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

A TER. Observation of Xe with the PNNL ARSA System PNNL UC-7 13

Magnetic Resonance Imaging of Polymer Electrolytes and Insertion Electrodes*

Half-Cell, Steady-State Flow-Battery Experiments. Robert M. Darling and Mike L. Perry

Data Comparisons Y-12 West Tower Data

Determinktion of Iodine to Compliment Mass Spectrometric Measurements

Multicusp Sources for Ion Beam Lithography Applications

Impurity Transport Studies of Intrinsic MO and Injected Ge in High Temperature ECRH Heated FTU Tokamak Plasmas

IMPACT OF EDGE CURRENT DENSITY AND PRESSURE GRADIENT ON THE STABILITY OF DIII-D HIGH PERFORMANCE DISCHARGES

DlmRiBUnON OF THIS DOCUMENT IS UNLIMITED. II I A TUBE-EXCITED X-RAY FLUORESCENCE SPECTROMETER FOR USE IN SMALL-DIAMETER BOREHOLES

Clifford K. Ho and Michael L. Wilson Sandia National Laboratories. P.O. Box Albuquerque, NM

FUSION WITH Z-PINCHES. Don Cook. Sandia National Laboratories Albuquerque, New Mexico 87185

Use of Gamma Rays from the Decay of 13.8-sec "Be to Calibrate a Germanium Gamma Ray Detector for Measurements up to 8 MeV

D. L. Strenge PNL-SA A GENERAL ALGORITHM FOR RADIOACTIVE DECAY WITH BRANCHING AND LOSS FROM A MEDIUM DISCLAIMER. July 1995

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

ITP Filtrate Benzene Removal Alternatives

Learning Outcomes: At the end of this assignment, students will be able to:

GA A26057 DEMONSTRATION OF ITER OPERATIONAL SCENARIOS ON DIII-D

K.M. Hoffmann and D. C. Seely

ASTER. Dose Rate Visualization of Radioisotope Thermoelectric. Generators. RECElVED BEC OF THIS DOCUMEMT IS UNLlMIi L, Hanford Company

Peak Reliability Delivering near real-time phase angle deltas using Inter-Control Center Communication Protocol (ICCP)

Measurement of Low Levels of Alpha in 99M0Product Solutions

Destruction of 2,4,6=Trinitrotoluene using Ammonium Peroxydisulfate

GA A26686 FAST ION EFFECTS DURING TEST BLANKET MODULE SIMULATION EXPERIMENTS IN DIII-D

Plutonium 239 Equivalency Calculations

Universal Indicator turns green. Which method is used to obtain pure solid X from an aqueous solution? A. mixture

ADSORPTION ON NANOSURFACES: A DETAILED LOOK AT METAL CLUSTERS USING INFRARED SPECTROSCOPY

STABILIZATION OF m=2/n=1 TEARING MODES BY ELECTRON CYCLOTRON CURRENT DRIVE IN THE DIII D TOKAMAK

Colliding Crystalline Beams

MAGNETICALLY CONTROLLED DEPOSITION OF METALS USING GAS PLASMA. Quarterly Progress Report April - June 1997

12/16/95-3/15/96 PERIOD MULTI-PARAMETER ON-LINE COAL BULK ANALYSIS. 2, 1. Thermal Neutron Flux in Coal: New Coal Container Geometry

The Impacts of Carbon Dioxide Storage in the Saline Arbuckle Aquifer on Water Quality in Freshwater Aquifers in Kansas

A Geological and Geophysical Assessment of the Royal Center Gas Storage Field in North-Central Indiana, a Joint NIPSCO, DOE & GRI Case Study

PROJECT PROGRESS REPORT (06/16/1998-9/15/1998):

RESEARCH OPPORTUNITIES AT THE CNS (Y-12 AND PANTEX) NUCLEAR DETECTION AND SENSOR TESTING CENTERS (NDSTC)

Synthesis of Methyl Methacrylate from Coal-derived Syngas

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

Multi-Scale Chemical Process Modeling with Bayesian Nonparametric Regression

Neutron Detector Gamma Insensitivity Criteria

RECXWH2 W/o s3-1

Simulation of Double-Null Divertor Plasmas with the UEDGE Code

sample-specific X-ray speckle contrast variation at absorption edges $ & ~ 0

August 3,1999. Stiffness and Strength Properties for Basic Sandwich Material Core Types UCRL-JC B. Kim, R.M. Christensen.

Scaling between K+ and proton production in nucleus-nucleus collisions *

Transcription:

DOE/FIU SCIENCE & TECHNOLOGY WORKFORCE DEVELOPMENT PROGRAM STUDENT SUMMER INTERNSHIP TECHNICAL REPORT June 6, 2008 to August 15, 2008 Caustic Dissolution of Chromium Compounds Present in Hanford Tanks Principal Investigator: Alexander Henao (DOE Fellow Student) Florida International University Acknowledgements: Renne Rusell, R&D Scientist Advanced Processing & Apllications Group Pacific Northwest National Laboratory Florida International University Collaborator: Leonel E. Lagos, Ph.D., PMP Prepared for: Department of Energy (DOE) Office of Environmental Management Under Grant No. DE-FG01-05EW07033

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, nor any of its contractors, subcontractors, nor their employees makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe upon privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any other agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. i

ABSTRACT The primary function of the waste treatment plant (WTP) at Hanford site is to treat highlevel and low-activity liquid waste and immobilize it by glass vitrification for final disposal. Currently, there are approximately 200,000 m 3 of radioactive waste in 177 underground storage tanks. All of them will be immobilized, followed by closing the tank farms, disposing of the immobilized low-activity waste (ILAW), shipping immobilized high-activity waste (IHLW) to offsite disposal facilities, decontaminating and decommissioning (D&D), and removing the treatment facilities and infrastructure. Because of the expected high costs associated with HLW immobilization and disposal, pretreatment processes will be performed to reduce the volume of the immobilized HLW. Certain Hanford wastes contain chromium at concentrations that strongly affect the volume of IHLW that can be vitrified. Chromium interferes with the HLW immobilization process; it causes, indirectly, shortness of the heating electrodes and clogging of the pour spout, thus jeopardizing the operation and life of the melter. For these reasons, minimization of the residual chromium concentration in the tank waste is an important pretreatment objective. Chromium is present in significant quantities in several of the Hanford waste tanks. It has been proposed that the chromium will be dissolved through caustic leaching in the Hanford Waste Treatment Plant currently under construction. In caustic conditions, the concentration of dissolved chromium is influenced by the concentration of caustic and various anions. Therefore, it is important to fully understand the effect various anions that are present in the Hanford waste have on the boehmite and gibbsite dissolution so that the process can be optimized. To determine the influence of various anions, a series of dissolution tests were performed with different caustic and anion concentrations. The tests were carried out using a special vessel with a blade spinning at 200 rpm and at a range of 97-100 degrees in temperature. Samples were taken at 0, 1, 2, 4, 8, and 24 hour intervals. This work focused on determining the equilibrium concentration of chromium in solution under the varying caustic and anion combinations and concentrations. ii

ACKNOWLEDGMENTS I would like to acknowledge Pacific Northwest National Laboratory (PNNL), the Department of Energy and Florida International University for their support in this study. Without their support, none of this would have been possible. I would also like to express my appreciation for the support and mentorship of Renne Russell, Don Reinhart, Dr. Leonel E. Lagos, and Dr. Georgio Tachiev. iii

TABLE OF CONTENTS Abstract... ii Acknowledgments...iii Introduction... 1 Experimentation... 2 Inductively Coupled Plasma (ICP)... 4 Data & Results...5 Conclusions...8 References...9 iv

LIST OF FIGURES Figure 1. Schematic drawing of the caustic leaching test setup... 3 Figure 2. Chromium concentration over time..7 LIST OF TABLES Table 1. Amounts (g) Used in Cr Testing... 2 Table 2. Matrix Used in Cr Testing... 3 Table 3. Sample Concentrations of Chromium... 5 v

INTRODUCTION Currently, there are approximately 200,000 m 3 of radioactive waste in the 177 underground storage tanks located at the U.S. Department of Energy s (DOE) Hanford Site. As part of the remediation efforts for these underground storage tanks, DOE plans to retrieve, immobilize, and dispose of this radioactive waste. The waste in the tanks is generally divided into three categories: supernatant, saltcake, and sludge. The liquid supernatant is alkaline, with high concentrations of salts such as sodium nitrate (NaNO3), sodium nitrite (NaNO2), sodium hydroxide (NaOH), sodium carbonate (Na2CO3), sodium phosphate (Na3PO4), and sodium sulfate (Na2SO4). Dilute hydroxide washing is the minimum pretreatment that would be performed on Hanford tank sludge. In this method, the sludge is mixed with dilute (0.1 M or less) NaOH, and then some sort of solid/liquid separation is performed. This is meant to remove water-soluble sludge components (mainly sodium salts) from the HLW stream. Dilute hydroxide is used rather than water to maintain the ionic strength high enough that colloidal suspensions are avoided. Caustic leaching (sometimes referred to as enhanced sludge washing or ESW) represents the baseline method for pre-treating Hanford tank sludge. Caustic leaching is expected to remove a large fraction of the Al, which is present in large quantities in Hanford tank sludge. The Al will be removed by converting aluminum oxides/hydroxides to sodium aluminate. For example, boehmite and gibbsite are dissolved according to the following equations (Weber 1982): AlOOH(s) + NaOH(aq) NaAlO2(aq) + H2O Al(OH)3(s) + NaOH(aq) NaAlO2(aq) + 2H2O Based on its known chemical behavior, Cr(III) was expected to be removed by caustic leaching according to the following equation: Cr(OH)3(s) + NaOH(aq) Na[Cr(OH)4](aq) However, studies conducted at the Pacific Northwest National Laboratory (PNNL) have suggested that the behavior of chromium in the caustic leaching process is more complex than previously thought. Chromium in tank sludge exists in both the +3 and +6 oxidation states. Chromium, when initially present in the +6 oxidation state, is effectively removed from the Hanford tank sludge solids by alkaline washing and caustic leaching. When present in the +3 oxidation state, however, chromium often dissolves poorly in simple alkaline-wash and causticleach solutions. Even when initially present in its +3 oxidation state, prior studies have shown that chromium exists only in caustic-leach solutions in its +6 oxidation state. Therefore, adding an oxidant to the sludge might be expected to facilitate conversion of Chromium (III) to its more alkaline-soluble form (chromate [CrO 4 2- ]) and so enhance its leaching from the sludge. 1

EXPERIMENTATION The composition of the waste in the Hanford tanks is a very complex mixture of chemicals. In order to find out which component of the waste is hindering the dissolution of chromium, the following compounds were studied and analyzed: Oxalate Sludge Supernate Gibbsite Boehmite To obtain a good understanding of the dissolution of chromium, a full scale matrix was created by a PNNL scientist. A specific amount of chromium was added to each of the 15 samples in the reaction vessel. The reaction vessel had a mechanical stirrer, a thermocouple, and a port for sampling while being air-tight. A heating mantle was used to keep the vessel at a constant temperature throughout the test. Samples were taken at 0, 1, 2, 4, 8, and 24 hours. A final sample was also taken when the solution came to room temperature. The samples were then passed through a 0.2-µm Nylon syringe filter to remove all solid matter that might be present in the sample. The next step was to analyze the samples to determine how much chromium had dissolved by measuring its concentration. Table 1 shows the amounts used for each of the 15 samples and Table 2 shows the matrix used in the chromium testing. Figure 1 provides a schematic drawing of the caustic leaching test set-up. Table 1 Amounts (g) Used in Cr Testing Test ID 19M DI Sodium Fe-Rich Supernate Gibbsite Boehmite CrOOH NaOH water Oxalate Sludge CR-1 400.54 397.8 0 0 0 0 0 3.86 CR-2 200.27 198.9 6.5 264 14 57.2 57.2 1.93 CR-3 400.54 397.8 13 0 0 0 0 3.86 CR-4 200.27 198.9 0 264 0 0 0 1.93 CR-5 400.54 397.8 0 0 28 0 0 3.86 CR-6 400.54 397.8 0 0 0 114.4 0 3.86 CR-7 400.54 397.8 0 0 0 0 114.4 3.86 CR-8 200.27 198.9 6.5 264 0 0 0 1.93 CR-9 400.54 397.8 13 0 28 0 0 3.86 CR-10 200.27 198.9 0 264 14 0 0 1.93 CR-11 400.54 397.8 0 0 0 114.4 114.4 3.86 CR-12 200.27 198.9 0 264 0 57.2 0 1.93 CR-13 400.54 397.8 13 0 0 114.4 0 3.86 CR-14 400.54 397.8 0 0 28 114.4 0 3.86 CR-15 200.27 198.9 6.5 264 14 0 0 1.93 2

Table 2. Matrix to Used in Cr Testing Test ID OH- Oxalate Sludge Supernate Gibbsite Boehmite CR-1 X CR-2 X X X X X X CR-3 X X CR-4 X X CR-5 X X CR-6 X X CR-7 X X CR-8 X X X CR-9 X X X CR-10 X X X CR-11 X X X CR-12 X X X CR-13 X X X CR-14 X X X CR-15 X X X X Measuring TC Stir Shaft Control TC Sampling Port Heating Mantle Liquid Level Reaction Vessel Baffle Figure 1. Schematic drawing of the caustic leaching test setup. 3

INDUCTIVELY COUPLED PLASMA (ICP) Inductively coupled plasma (ICP) is an analytical technique used for the detection of trace metals in environmental samples. The primary goal of ICP is to get elements to emit characteristic wavelength specific light which can then be measured. The technology for the ICP method was first employed in the early 1960's with the intention of improving upon crystal growing techniques. Since then, ICP has been refined and used in conjunction with other procedures for quantitative analysis. Following is a cursory look at the driving forces behind this analytical tool, its use in series with other analytical tools, and environmental applications of ICP. Often, ICP is used in conjunction with other analytical instruments, such as the atomic emission spectroscopy (AES) and the mass spectroscopy (MS). This is an advantageous practice, as both the AES and MS require that sample to be in an aerosol or gaseous form prior to injection into the instrument. Thus, using an ICP in conjunction with either of these instruments eliminates any sample preparation time which would be required in the absence of an ICP. 4

DATA & RESULTS Once the samples were filtered and processed, they were sent to an analytical laboratory for analysis. Table 3 provides the concentration of chromium removed from the solutions. CR1-0 5.84E-05 CR1-1 9.46E-04 CR1-2 7.42E-04 CR1-4 7.00E-04 CR1-8 9.36E-04 CR1-24 2.30E-03 CR1-F 2.40E-03 Table 3. Sample Concentrations of Chromium CR5-0 6.46E-05 CR5-1 6.66E-04 CR5-2 6.56E-04 CR5-4 6.74E-04 CR5-8 1.02E-03 CR5-24 2.43E-03 CR5-F 2.56E-03 CR2-0 2.05E-03 CR2-1 3.77E-03 CR2-2 4.73E-03 CR2-4 6.24E-03 CR2-8 8.82E-03 CR2-24 1.38E-02 CR2-F 1.41E-02 CR3-0 8.85E-06 CR3-1 4.74E-04 CR3-2 4.23E-04 CR3-4 4.52E-04 CR3-8 7.90E-04 CR3-24 2.19E-03 CR3-F 2.24E-03 CR4-0 2.61E-03 CR4-1 6.43E-03 CR4-2 7.88E-03 CR4-4 1.01E-02 CR4-8 1.35E-02 CR4-24 2.11E-02 CR4-F 2.35E-02 Cr-6-0 5.58E-05 Cr-6-1 2.69E-04 Cr-6-2 3.17E-04 Cr-6-4 4.54E-04 Cr-6-8 7.14E-04 Cr-6-24 1.91E-03 Cr-6-F 2.02E-03 Cr-7-0 3.38E-05 Cr-7-1 1.86E-03 Cr-7-1repeat 1.85E-03 Cr-7-2 1.19E-03 Cr-7-4 9.59E-04 Cr-7-8 1.18E-03 Cr-7-24 2.44E-03 Cr-7-F 2.75E-03 Cr-8-0 2.19E-03 Cr-8-1 4.46E-03 Cr-8-2 6.66E-03 Cr-8-4 8.13E-03 Cr-8-8 1.11E-02 Cr-8-24 1.76E-02 Cr-8-F 1.77E-02 5

Cr-9-0 5.05E-06 Cr-9-1 7.75E-04 Cr-9-2 6.72E-04 Cr-9-4 6.21E-04 Cr-9-8 8.78E-04 Cr-9-24 2.21E-03 Cr-9-F 2.35E-03 Cr-10-0 2.21E-03 Cr-10-1 5.57E-03 Cr-10-2 7.28E-03 Cr-10-4 8.36E-03 Cr-10-8 1.04E-02 Cr-10-24 1.56E-02 Cr-10-F 1.59E-02 CR-11-0 5.79E-05 CR-11-1 3.86E-04 CR-11-2 4.86E-04 CR-11-4 5.48E-04 CR-11-8 8.25E-04 CR-11-24 2.01E-03 CR-11-F 2.09E-03 CR-12-0 2.34E-03 CR-12-1 4.66E-03 CR-12-2 6.39E-03 CR-12-4 8.02E-03 CR-12-8 1.04E-02 CR-12-24 1.65E-02 CR-12-F 1.66E-02 CR-13-0 6.22E-05 CR-13-1 2.71E-04 CR-13-2 2.93E-04 CR-13-4 4.11E-04 CR-13-8 6.38E-04 CR-13-24 1.80E-03 CR-13-F 1.85E-03 CR-14-0 1.08E-04 CR-14-1 2.58E-04 CR-14-2 3.07E-04 CR-14-4 4.28E-04 CR-14-8 6.58E-04 CR-12-24 1.86E-03 CR-14-F 1.87E-03 CR-15-0 2.22E-03 CR-15-1 4.36E-03 CR-15-2 5.85E-03 CR-15-4 7.20E-03 CR-15-8 9.46E-03 CR-15-24 1.50E-02 CR-15-F 1.56E-02 After obtaining the data from the analytical laboratory, the concentration of chromium vs. time was plotted to observe which of the chemicals was hindering the reaction (Figure 2). 6

Concentration 2.50E-02 2.00E-02 1.50E-02 1.00E-02 5.00E-03 0.00E+00 Chromium Concentration Vs Time CR1-0 CR1-1 CR1-2 CR1-4 CR1-8 CR1-24 CR1-F Time Figure 2. Chromium concentration over time. Only NaOH Full Matrix Sodium Oxalate Fe Rich Sludge Supernate Gibbsite Boehmite Oxalate/Sludge Oxalate/Supernate Sludge/Supernate Gibbsite/Boehmite Sludge/Gibbsite Oxalate/Gibbsite Supernate/Gibbsite Oxalate/Sludge/Supernate 7

CONCLUSIONS The results obtained in the course of this investigation led to the following key conclusions concerning the caustic dissolution of Cr (III) solid phases under alkaline conditions by sodium hydroxide. Studies were most extensive for Cr(III) hydroxide phases because they seem to be the most likely form of Cr(III) in Hanford tank sludge, especially after caustic treatment. 1. Oxalate was previously believed to be the hindering compound that slowed down the reaction of chromium, but by observing the graph, it is concluded that oxalate has no effect on the reaction. 2. When chromium is interacting only with the iron rich sludge, as in sample # 4, we can see that the reaction did not reach equilibrium in a 24-hour period, as the other samples did. 3. It seems that the iron rich sludge is making a side reaction that is keeping the reaction going past the 24-hour equilibrium point. 8

REFERENCES B.M. Rapko, J.D. Vienna. Selective Leaching of Chromium from Hanford Tank Sludge 241-U-108, Pacific Northwest National Laboratory, Richland, Washington. D. J. McCabe, R.A. Peterson, J.A. Pike, W.R. Wilmarth. Aluminum and Chromium Leaching, Workshop Whitepaper, Pacific Northwest National Laboratory, Richland, Washington. H. M. Cho, G. J. Lumetta. Preliminary Feasibility Study of Using Solid-State Nuclear Magnetic Resonance Spectroscopy to Characterize Hanford Tank Waste Solids, Pacific Northwest National Laboratory, Richland, Washington. N. N. krot, A. Ydh.rnov, V. P. Shilov, I. A. Charushnikova, A.M. Fedoseev, V. P.Perminov, N. A. Budantseva, L. N. Astafurova, M. V. Nkonov, T. S. Lapitskaya, A. B. Yusov, V. L Makarenkov, Development of Alkaline Oxidative Dissolution Methods for Chromium(III) Compounds Present in Hanford Site Tank Sludges, Pacific Northwest National Laboratory, Richland, Washington. Traci Bradford and M. Nicole Cook, Traci Bradford and M. Nicole Cook. Website: www.cee.vt.edu/ewr/environmental/teach/smprimer/icp/icp.html#combining%20 ICP%20with%20Atomic%20Emission%20Spectroscopy. 9