The Claviature of Gas Analysis

Similar documents
White Paper. Overview: NDIR Definition:

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Introduction. Chapter 1. Learning Objectives

Relative Sensitivity RS Measurements of Gases

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.


Measurement standards and the general problem of reference points in

2401 Gas (liquid) Chromatography

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

The Theory of HPLC. Quantitative and Qualitative HPLC

Far UV Absorbance Detector

Introduction to GC/MS

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

Chapter 31 Gas Chromatography. Carrier Gas System

Introduction to Fourier Transform Infrared Spectroscopy

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Analytical methods for hydrogen fuel QC Thomas Bacquart, Sam Bartlett, Abigail S.O. Morris, Nick Allen, Arul Murugan

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Research Equipment in the UCA Chemistry Department

UV3000. Accurate, precise, and portable ambient gas point analyzer

Chem!stry. Atomic Structure and Chemical Bonding Concepts: Change, Models & Systems

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Catalysis CAPABILITIES

Technical know-how in thermal analysis measurement

Training Coarse ECOPROBE 5 CHEMISTRY RS DYNAMICS

Chapter 27: Gas Chromatography

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Luminescence transitions. Fluorescence spectroscopy

SIFT-MS. technology overview

Mass Spectrometry (MS)

Multi-residue analysis of pesticides by GC-HRMS

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Gas chromatography. Advantages of GC. Disadvantages of GC

Measurement Technique and its Application to Trace Components of Atmospheric Gas

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

UNIT 3 CHEMISTRY. Fundamental Principles in Chemistry

TANDEM MASS SPECTROSCOPY

Introduction to Mass Spectrometry (MS)

Application Note S/SL

Chapter 12 Mass Spectrometry and Infrared Spectroscopy

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Prima PRO Process Mass Spectrometer

Introduction to Gas Phase FTIR Spectroscopy

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

HYPHENATED TECHNOLOGY GUIDE

Substance Characterisation for REACH. Dr Emma Miller Senior Chemist

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Extrel Application Note

Author. Abstract. Introduction

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

CHEM 241 UNIT 5: PART A DETERMINATION OF ORGANIC STRUCTURES BY SPECTROSCOPIC METHODS [MASS SPECTROMETRY]

Qualitative Analysis of Unknown Compounds

Structural characterization begins with a purity check!

Secondary ion mass spectrometry (SIMS)

a. An emission line as close as possible to the analyte resonance line

Introduction to Fourier Transform Infrared Spectroscopy

Defining quality standards for the analysis of solid samples

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Process Analyzer and Sampling Systems

Questions on Instrumental Methods of Analysis

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

AP CHEMISTRY READING GUIDE

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Mercury Stack Monitor SM-4

Investigation of Water Fragments

Introduction to Gas Chromatography

HYPHENATED TECHNOLOGY GUIDE

(2) Read each statement carefully and pick the one that is incorrect in its information.

Secondary Ion Mass Spectrometry (SIMS)

TO-15 Checklist Determination of VOCs in Air by GC-MS

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

M06/4/CHEMI/HP3/ENG/TZ0/XX CHEMISTRY HIGHER LEVEL PAPER 3. Candidate session number 0 0. Friday 19 May 2006 (morning) 1 hour 15 minutes

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Polymer plants continue to seek ways to increase production and efficiency without compromising safety.

LAB007 Industrial Analytical Chemistry & Process Analyzer System

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

EnCal 3000 Hydrocarbon Dew Point Calculation - C 9 analysis - C 12 analysis

Instrumental Chemical Analysis

Chromatography. Gas Chromatography

In-Situ 13 C/ 12 C Ratio Analysis in Water Carbonates using FTIR

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Rosemary extract liquid

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Real-time ppb CO 2 Impurity Detection by an Advanced FTIR- UVF System

An ion source performs the following two functions:

OCR Chemistry Checklist

Chlorine disinfectant in the water industry

Transcription:

The Claviature of Gas Analysis Mass spectrometric gas analysis for quality assurance of gases and gas mixtures High purity and special gases are becoming increasingly important in the development of modern technologies. The demand placed on purity and diversity of mixture formulations are constantly challenging manufacturers and users in production, quality control and the use of these gases and gas mixtures. The required analytics is becoming increasingly complex and can only be realized by applying and combining a wide variety of methods. Using the example of analytics in a dedicated gas center, examples of tasks and solutions are outlined. By VOLKER FREY, MICHAEL BRUDEL Dr. VOLKER FREY is Deputy Head of the Special Gases Centre of the Westfalen AG in Hörstel, Germany Dr. MICHAEL BRUDEL is responsible for product support and marketing at InProcess Instruments in Bremen, Germany. Various techniques and processes are used for the production and quality assurance of gases and gas mixtures. A flexible and efficient analysis technology is particularly needed for customer-specific gas mixtures. Mass spectrometry (MS) is a valuable addition to standard techniques (GC, IR, UV, etc.) and to a variety of special methods. It is ideally suited to a variety of problems. Westfalen's Special Gases Center, a manufacturer of technical gases founded in Münster in 1923 and now active throughout Germany, focused primarily on maximum flexibility of the mass spectrometer for a wide range of measurement tasks when it purchased the Instrument. The special version of a GAM 400 from InProcess Instruments, which has three gas inlets connected to a quadrupole mass analyzer, came closest to this requirement. Based on joint preliminary tests and intensive discussions, the system was designed and tailor-made for Westfalen. The strengths of the individual analysis methods and in which cases the combination Westfalen's Special Gases Center uses various analytical systems to quantify customer specific gas mixtures. of several methods is necessary, is exemplified by various application examples, which can be assigned to the fields of activity in the Specialty Gases Centre Hörstel: High purity gas analysis; Analytics for the exact characterization of customer-specific gas mixtures; Development of analytical methods for new components in gas mixture formulations and Analysis orders. For each of these areas, specific methods and analysis strategies are in place.

Analysis of high purity gases For this application, the produced high purity gases (nitrogen, argon, oxygen, hydrogen, helium, carbon dioxide) are tested for secondary components (impurities) as part of the routine analysis. Depending on the constituents, the high-purity gases are produced up to 6.0 gas purity (corresponding to 99.9999 percent purity). This implies that the total of the secondary constituents must not exceed 0.0001 vol. percent = 1 vol. ppm. The analytical instrumentation is optimized such that it reliably measures the corresponding secondary constituents within the specified concentration range in a wide variety of gases. Gas chromatography with helium or argon ionization detectors is used for the most part. The advantage of these detectors is the low detection limit (vol. ppb range) of the permanent gases e.g. in the air. The disadvantage results with only two decades from the low range of linearity. Various instruments are used to determine the moisture content in gases. They can be based on dew point mirrors, phosphorus pentoxide, capacitive aluminium oxide measuring cells or oscillating quartz technology. Traces of Oxygen are detected up to the volume ppm range using the redox measurement method. In order to carry out these these measurements, precise calibration gases are needed that have to be produced and tested. The quality assurance of these test gases is done by mass spectrometry. The advantage of this method particularly results with more than six decades from the very large linearity range. On the other hand, the zero point of the component in question has to be determined as accurately as possible. The use of gases with quality 6.0 is not sufficient. Therefore, highly efficient post-cleaning processes are deployed. Analytics of customized gas mixtures The GAM 400 mass spectrometer, here with different inlet systems, serves a mass range of 1 to 300 amu. In this field of work, gas mixtures, which are produced according to the customer's wishes and recipe, are analyzed for their true value. The prerequisite for production of such customized gases is, among other things, a official manufacturing permit and the infrastructure for testing or ensuring the stability of the gas mixtures. Hence, all potential chemical reactions between the individual components and the gas cylinder and the valve material must be examined. Westfalen's Specialty Gases Centre currently stocks approx. 150 individual components, which are gravimetrically combined to customer-specific formulations depending on feasibility. To date, these formulations contain up to 20 individual substances. The concentrations that can be produced and analyzed range depending on the substance from a few vol. ppb to the

percentage range. New recipes are added almost daily to the approx. 4,000 recipes already stored. The combination of different analytical methods is often used to effectively achieve correct results. Beside the classical gas chromatography with different separation columns and detectors (WLD, FID, FPD, ECD), mass spectrometry, infrared spectroscopy (NDIR, FTIR) and the chemiluminescence method (partly parallel) are also used - depending on the analytical question. With over 4,000 different recipes, it is difficult to assess, which techniques should be used and when. In general, the measuring procedure must be unambiguous. For example, in mass spectrometry or IR spectroscopy masses or wave numbers that are interfered by other components of the mixture must not be used. With GCs, it is important that the evaluated components do not have the same retention times. Cross-sensitivity, artifact formation and quenching effects must be considered. Hence, method development and validation take up a considerable part of the time for the entire analyses. Standardized analytical methods are used for frequently analyzed formulations. Analysis of new components in gas mixtures New or additional components specified by the users have to be mixed into existing gas formulations. This determines the further procedure. Before actual production, test and release procedures have to be followed for the new components, which go beyond those described in the previous section. Only then, reference gases are independently of one another produced in accordance with EN 6142. The methods suitable for quantitative measurement are then tested in compliance with DIN EN 6143. All analytical equipment and methods present in the Specialty Gases Centre are considered. Where possible, these gas mixtures are also validated with external standards. Finally, the new formulations are tested for stability. Mass spectrometer systems are highly selective and capable of multi component analysis. Contract analytics In Special Gases Centers as described above, most known gas mixtures are analyzed quantitatively only. Unknown gas mixtures are measured both, qualitatively and quantitatively after the analytical method has been developed. After a qualitative analysis with FTIR and MS (spectra recording in scan mode), next steps for the systematic procedure is determined caseby-case.

Combination of different analytical methods One example is the production of 500 vol. ppb of sulfur isotope 34 (34SO2) in sulfur dioxide in nitrogen. Due to the low concentration of the 34SO2 in the mixture, the mass spectrometer is here not suited for the quantitative analysis. Therefore, the quantitative analysis is performed with a sulfur dioxide analyzer. This UV spectrometer has a detection range from 0.1 vol. ppb to 500 vol. ppb. However, only the mass spectrometer can be used to test the isotope distribution in pure sulfur dioxide. Traces of nitrogen monoxide, sulfur dioxide and carbon monoxide mixed with nitrogen as main component are particularly difficult to analyze. Th gas chromatography at the Special Gas Centre is not sufficient for such mixtures. This is why nitrogen monoxide is analyzed with the chemiluminescence analyzer, while sulfur dioxide and carbon monoxide are quantified with the IR spectroscopy. Application of the mass spectrometer Depending on the method, the mass spectrometer system can be used for a wide range of analyses in the Specialty Gases Center. It is therefore one of the most important and versatile analytical instruments. This is because of the universality of the measurement principle, which is characterized by high selectivity, multi-component capability, short measuring times, high sensitivity and a wide dynamic range. The verification of the accuracy of analytical results by the analysts is of great importance. The MS is used as for special analysis methods of high purity gases, gas mixtures and special gases. Besides the direct quantitative determination of trace components down to the ppm range, it is also possible to measure isotopic compositions. The technique is particularly strong in the determination of non-polar molecules, such as noble gases. The instrument has been specially designed for fast and accurate gas analysis of the mass range 1 to 300 amu. The combination of different gas inlets makes it particularly well suited for the special gas center because it has a batch inlet for the measurement of smallest gas quantities ; a direct capillary inlet for highly reactive components such as chlorine a gas inlet for routine analyses with a continuous gas flow a possibility to switch to a second gas flow, e.g. for calibration or zero gas measurements. The flexible solutions of the instrument technology as InProcess Instruments develops and manufactures them, enable a wide use of mass spectrometry for many different tasks. It is therefore a valuable addition to other analytical methods at the Westfalen's Specialty Gases Center. Like IR spectroscopy (not all gases are IR-active or have only weak absorption bands),

mass spectrometry also has its limits because of its physical principles. The formation of artifact ions in the ion source by gas phase or wall reactions must be considered for certain gas compositions. For example, the exact quantitative determination of a few vol. ppm nitrogen monoxide in mixtures containing nitrogen and oxygen is very difficult. Surface effects in the vacuum region of the mass spectrometer must be particularly taken into account when interpreting the measurement results of trace components. For example, the mass spectrometer is not the method of choice for the determination of traces of water in gas mixtures. For quadrupole analyzers with limited mass resolution, certain restrictions also apply to the quantitative acquisition of components with mass interferences. For example, the exact determination of carbon monoxide (mass number 28) in nitrogen (also mass number 28) by a matrix calculation of the fragments is only possible in the percentage range. A wide range of measurement methods and instruments are necessary for demanding gas analysis. Yet mass spectrometry plays an outstanding role. In addition to high-resolution sector field mass spectrometry and the many special systems for bio- and elemental analysis, quadrupole mass spectrometers are of particular importance for gas analysis because of their flexibility and good price/performance ratio. For the full benefit of this technology, an individual instrument concept and application-related guidance and support are required before and after the purchase of the instrument. Conclusion Quality assurance of ultrapure and special gases is becoming increasingly complex and requires new, sophisticated solutions. Adding a mass spectrometer to the analytical toolset provides new possibilities for gas analysis and quality control. The GAM 400 from InProcess Instruments is a device used in Westfalen's Special Gases Centre for a wide range of measurement tasks, such as isotope purity control, the quantitative detection of noninfrared sensitive compounds and the determination of gas concentrations in mixtures. This quadrupole mass spectrometer specifically designed for the tasks at Westfalen is best suited for fast and precise gas analysis at a mass range of 1 to 300 amu. Several gas inlets allow trace measurements of reactive components as well as high precision measurements with low sample consumption. Quoted from Web Magazine P&A, June 2005