Recent Results from the Cryogenic Dark Matter Search. Bruno Serfass - UC Berkeley on behalf of the CDMS and SuperCDMS collaborations

Similar documents
Scalability of the SuperCDMS experiment

Constraints on Low-Mass WIMP Signals from CDMS. Steven W. Leman (MIT) 18 March 2011 Rencontres de Moriond EW La Thuile, Valle d Aosta, Italy

Results from CRESST and CDMS

Pushing the Limits: Dark Matter Search with SuperCDMS. Wolfgang Rau Queen s University Kingston For the SuperCDMS Collaboration

CDMS-II to SuperCDMS

CDMS. Vuk Mandic. 13. July 2010

Identification of the Surface Event Background in the CDMS II Experiment. Sunil Golwala for the CDMS II Collaboration Caltech August 21, 2008

Present Status of the SuperCDMS program

Supporting Online Material for

Status of the Cryogenic Dark Matter Search Experiment

New Results from the CDMS-II experiment

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

WIMP EXCLUSION RESULTS FROM THE CDMS EXPERIMENT

The complex vacuum configurations contribute to an extra non-perturbative term in the QCD Lagrangian[1],

Searches for Low-Mass WIMPs with CDMS II and SuperCDMS

arxiv: v1 [astro-ph.im] 18 Jan 2012

SuperCDMS: Recent Results for low-mass WIMPS

Search for Axions with the CDMS Experiment

Direct Searches for Dark Matter and the CDMS Experiment

arxiv: v1 [astro-ph.co] 4 Oct 2014

Dark Matter Search Results from the Silicon Detectors of the Cryogenic Dark Matter Search Experiment

CDMS and SuperCDMS. SLAC Summer Institute - CDMS. August 2, 2007 Blas Cabrera Co-Spokesperson CDMS & Spokesperson SuperCDMS

arxiv: v3 [physics.ins-det] 4 Oct 2013

First CDMS II Five-Tower Results. Sunil Golwala SLAC Summer Institute 2008 August 7, 2008

Limits on spin-dependent WIMP-nucleon interactions from the Cryogenic Dark Matter Search

Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with low Transition-Edge-Sensor Transition Temperature

Recent results from the second CDMSlite run and overview of SuperCDMS SNOLAB project

Search for Inelastic Dark Matter with the CDMS experiment. Sebastian Arrenberg Universität Zürich Doktorierendenseminar 2010 Zürich,

A survey of recent dark matter direct detection results

Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors

Systematics of Low Threshold Modulation Searches in CDMS II

Dark Matter Direct Detection

The Cryogenic Dark Matter Search (CDMS) : Status and future. Kipac SLAC April 2009

Status of the EDELWEISS Dark Matter search

Cryogenic Detectors Direct Dark Matter Search. Dark Matter

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

The CDMS-II Dark Matter Search and SuperCDMS

Direct Dark Matter and Axion Detection with CUORE

Direct dark matter search with XMASS. K. Abe for the XMASS collaboration

Search for Low Energy Events with CUORE-0 and CUORE

The XENON1T experiment

The EDELWEISS DM search Phase II to Phase III

DUSEL NATIONAL LAB ROLE ESSENTIAL FOR SNOLAB AND DUSEL EXPERIMENTS SLUO

Axion search with Dark Matter detector

Ge and Dark Matter Searches: CDEX, present and future

Direkte Suche nach Dark Matter

Dark Matter. and TPC Technologies

SuperCDMS at SNOLAB. What is CDMS? Technical Progress. Collaboration. Funding. Schedule and Needs. Why is SuperCDMS 25 kg timely?

arxiv: v1 [astro-ph.co] 17 Mar 2011

Toward A Consistent Picture For CRESST, CoGeNT and DAMA. Chris Kelso Fermilab and University of Chicago Cosmology on the Beach Jan.

The Direct Search for Dark Matter

Cryodetectors, CRESST and Background

Direct Detection Lecture 2: Current Results

arxiv:astro-ph/ v1 24 Jun 2004

Chapter 12. Dark Matter

DarkSide new results and prospects

Overview of Direct Detection Dark Matter Experiments

Results from 730 kg days of the CRESST-II Dark Matter Search

arxiv: v1 [physics.ins-det] 4 Nov 2017

Recent results from PandaX- II and status of PandaX-4T

Background and sensitivity predictions for XENON1T

Quenchings in crystals!

Direct Detection in the next five years: Experimental challenges and Phonon Mediated Detectors

Looking for WIMPs A Review

The LZ Experiment Tom Shutt SLAC. SURF South Dakota

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

arxiv:astro-ph/ v1 8 Jul 2005

What is the probability that direct detection experiments have observed Dark Matter?

ANAIS: Status and prospects

light dm in the light of cresst-ii

Direct Search for Dark Matter

XMASS: a large single-phase liquid-xenon detector

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Esperimenti bolometrici al Gran Sasso: CUORE e CRESST

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

Latest Results on Direct Detection of Dark Matter WIMPs - CDMS & SuperCDMS

arxiv: v1 [physics.ins-det] 22 Dec 2016

Latest results of EDELWEISS II

Precision Measurement Of Nuclear Recoil Ionization Yields For Low Mass Wimp Searches

XENON100. Marc Schumann. Physik Institut, Universität Zürich. IDM 2010, Montpellier, July 26 th,

Dark Matter Search * in China

Juan Estrada Fermi National Accelerator Laboratory 1

Direct Dark Matter Searches

The Search for Dark Matter with the XENON Experiment

The XENON Project. M. Selvi The XENON project

Position calibration of cryogenic dark matter detectors

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

LUX-ZEPLIN (LZ) Status. Attila Dobi Lawrence Berkeley National Laboratory June 10, 2015 WIN Heidelberg

Halo-independent analysis of direct detection data for light WIMPs

Direct Detection of Dark Matter: Not Noble Gases

DarkSide. Bianca Bottino Università di Genova and INFN Sezione di Genova on behalf of the DarkSide collaboration 1

Inelastic Dark Matter and DAMA

Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

Dark Matter, Low-Background Physics

Backgrounds and Sensitivity Expectations for XENON100

Direct Detection of Dark Matter with LUX

DarkSide-50: performance and results from the first atmospheric argon run

TWO-PHASE DETECTORS USING THE NOBLE LIQUID XENON. Henrique Araújo Imperial College London

PandaX Dark Matter Search

Status of Dark Matter Detection Experiments

Transcription:

Recent Results from the Cryogenic Dark Matter Search Bruno Serfass - UC Berkeley on behalf of the CDMS and SuperCDMS collaborations

CDMS/SuperCDMS Collaborations DOE NSF California Institute of Technology Z. Ahmed, J. Filippini, S.R. Golwala, D. Moore Fermi National Accelerator Laboratory D. A. Bauer, F. DeJongh, J. Hall, D. Holmgren, L. Hsu, E. Ramberg, R.L. Schmitt, J. Yoo Massachusetts Institute of Technology E. Figueroa-Feliciano, S. Hertel, S.W. Leman, K.A. McCarthy, P. Wikus NIST K. Irwin Queen s University C. Crewdon*, P. Di Stefano*, O. Kamaev, C. Martinez*, K.Page*, P. Nadeau*, W. Rau, Y. Ricci* Saint Olaf College A. Reisetter Santa Clara University B. A. Young SLAC National Accelerator Laboratory/KIPAC* M. Asai*, A. Borgland*, D. Brandt*, P.L. Brink, W. Craddock*, E. do Couto e Silva*, G. Godfrey*, J. Hasi*, M. Kelsey*, C. J. Kenney*, P. C. Kim*, R. Partridge*, R. Resch*, K. Schneck*, A. Tomada, D. Wright* Southern Methodist University J. Cooley, B. Karabuga, H. Qiu * new collaborators or new ins/tu/ons in SuperCDMS Stanford University B. Cabrera, M. Cherry, L. Novak, R.W. Ogburn, M. Pyle, M. Razeti*, B. Shank*, S. Yellin, J. Yen* Syracuse University R. Bunker, Y. Chen*, M. Kiveni, M. Kos, R. W. Schnee Texas A&M K. Koch*, R. Mahapatra, M. Platt*, K. Prasad*, J. Sander University of California, Berkeley M. Daal,T. Doughty, N. Mirabolfathi, A. Phipps, B. Sadoulet, D. Seitz, B. Serfass, D. Speller, K.M. Sundqvist University of California, Santa Barbara D.O. Caldwell, H. Nelson University of Colorado Denver B.A. Hines, M.E. Huber University of Florida T. Saab, D. Balakishiyeva, B. Welliver * FT-UAM/CSIC and Universidad Autonoma de Madrid* D. G. Cerdeño*, L. Esteban* University of Minnesota H. Chagani*, J. Beaty, P. Cushman, S. Fallows, M. Fritts, T Hofer*, O. Kamaev, V. Mandic, X. Qiu, R. Radpour*, A. Villano*, J. Zhang 2

CDMSII Detectors 250g Ge or 100g Si 1cm thick x 7.5 cm diameter Phonon sensors on one face 4 quadrant with 888 TES sensor each Can lower thresholds significantly 4 R (Ω) 3 2 1 ~ 10mK T c ~ 80mK T (mk) 1 µ tungsten 380µ x 60µ aluminum fins Charge readout on the other face divided into inner fiducial volume and outer guard ring measure ionization in low E field (~ volts/cm) 2.0 kev nuclear recoil phonon pulse, T1Z5 3

CDMSII at Soudan Data taken with 5 Towers (30 detectors) between Oct. 2006 to Sept. 2008 WIMP search 10-100keV recoil published in 2010 (Ge detector): Ahmed et al., Science 327:1619-1621,2010 2 candidate events observed σ 3.8 x 10-44 cm 2 (90% C.L) @WIMP mass 70 GeV/c 2 Combined Limits from CDMS-Edelweiss (PRD 84, 011102(R) (2011)) On-going reanalysis using improved algorithms, include Si detectors Low Threshold (2 kev nr ) Analysis published in 2011 Ahmed et al., PRL 106, 131302 (2011); arxiv:1011.2482 (w/ addional commentary) Use 8 detectors with lowest trigger thresholds Small subset (1/4 of the data) used to study backgrounds at low energy Background limited: No phonon-timing cut since ineffective below ~5 kev, ionization yield is less effective 4

Low Threshold Analysis: Energy Calibration Phonon energy scale calibrated with electron recoil lines at 1.3 kev and 10.37 kev Nuclear recoil energy reconstructed from phonon signal alone after subtracting Neganov-Luke phonons (~15% of signal at low E) Start by assuming same scale as for electron recoils Measure mean ionization yield as function of inferred recoil energy for calibration neutrons down to 4 kev nr, power-law extrapolation to lower energies Electron recoil phonon spectrum, T1Z5 10.39±0.022 kevee Ionization Yield = Phonon-based recoil energy 1.333±0.025 kevee Lindhard (k=0.157) CDMS

Low Threshold Analysis: WIMP candidate selection Nuclear recoil acceptance region defined as (+1.25,-0.5)σ band in ionization energy Maximizes sensitivity to nuclear recoils while minimizing expected backgrounds Neutron calibration T1Z5 detector 6

Low Threshold Analysis: WIMP candidate selection Nuclear recoil acceptance region defined as (+1.25,-0.5)σ band in ionization energy Maximizes sensitivity to nuclear recoils while minimizing expected backgrounds T1Z5 detector 7

Low Threshold Analysis: WIMP candidate selection Nuclear recoil acceptance region defined as (+1.25,-0.5)σ band in ionization energy Maximizes sensitivity to nuclear recoils while minimizing expected backgrounds 1.3 kev line Compton Surface Zero-charge 8

Low WIMP Mass Limits Conservatively assume all candidates could be from WIMP NO background subtraction! Limits set using optimum interval method: S. Yellin, PRD, 66, 032005 (2002); arxiv:0709.2701v1 (2007) CDMS SUF (1 kev thresh) CDMS Soudan (10 kev thresh) DAMA/LIBRA For spin-independent, elastic scattering, 90% CL limits incompatible with DAMA/LIBRA and CoGeNT excess CDMS Low Threshold CoGeNT XENON10 XENON100 CDMS all det CoGeNT, L-shell peaks and constant bkgnd removed CDMS T1Z5 Ahmed et al., PRL 106, 131302 (2011); arxiv:1011.2482 Note: CoGeNT region not updated for revision to surface event contamination m χ =7 GeV/c 2 (90% CL) σ SI ~7x10-41 2x10-40 cm 2 Hooper et al., PRD 82 123509 (2010) If only a small fraction of the low-energy excess events in CoGeNT are due to WIMPs, then constraints from CDMS II can be avoided 9

Search for Annual Modulation CDMS II data nearly two annual cycles, from Oct. 2006 to Sept. 2008 Data quality and detector selection criteria in this analysis are identical to low threshold analysis Nuclear recoil acceptance region defined as ±2σ band in ionization energy to increase sensitivity We consider 3 energy intervals between 5 and 11.9 kev nr : [5,7.3], [7.3,9.6], and [9.6,11.9] kev nr For nuclear recoils, the electron recoil equivalent energy measured by CoGeNT would be [1.2,1.8], [1.8,2.5], and [2.5,3.2] kev ee 5 kev nr threshold high enough to have a nearly 100% trigger efficiency 11.9 kev nr maximum energy to match the highest energy of CoGeNT For electron recoils with the same total phonon, the equivalent E rang would be [3,4.4], [4.4,5.9], and [5.9,7.4] kev ee 10

Search for Annual Modulation What effect are we trying to test? In the lowest energy bin, [5, 7.3] kev nr, the nuclear-recoil rate measured for CDMS is 0.29 [kev nr kg day] -1 Maximum likelihood estimate for the CoGeNT modulation amplitude is 0.35±0.015 [kev nr kg day] -1 Would require modulation fraction in CDMS of nearly 100% (same for full energy range) 11

Stability Cut Efficiencies Test stability nuclear-recoil band and charge fiducial ( Qinner ) cut efficiencies using calibration data Using Feldman-Cousins method, determine confidence limits on the amplitude and phase of annual modulation Qinner NR band Averages run-by-run Contours: 68%, 95%, 99% Nuclear-recoil cut: efficiency modulation upper limit of 1.2% at 90% confidence level Qinner cut: efficiency modulation upper limit 2.3 % at 90% confidence level Consistent with no modulation (similar constraints for all energy bins) 12

Results: Nuclear Recoil Singles No significant evidence for annual modulation In the energy range [5, 11.9] kev nr, all modulated rate with amplitudes greater than 0.07 [kev nr kg day] -1 are ruled out with a 99% confidence. Annual modulation signal of CDMS and CoGeNT are incompatible at >95% C.L. (preliminary) for the full energy range (if CoGeNT signal originates in a nuclear-recoil population) CoGeNT PRELIMINARY CDMS PRELIMINARY Contours: 68%, 95%, 99% 13

Results: Nuclear Recoil Singles No significant evidence for annual modulation In the energy range [5, 11.9] kev nr, all modulated rate with amplitudes greater than 0.07 [kev nr kg day] -1 are ruled out with a 99% confidence. Annual modulation signal of CDMS and CoGeNT are incompatible at >95% C.L. (preliminary) for the full energy range (if CoGeNT signal originates in a nuclear-recoil population) CDMS CoGeNT CoGeNT PRELIMINARY CDMS PRELIMINARY Contours: 68%, 95%, 99% 14

Results: Electron-recoil-dominated Singles/Multiples Data sample with no ionization-yield cut No significant evidence for annual modulation for both singles and multiples Little overlap with the energy range of CoGeNT under the hypothesis of an ER modulation. (3.2 kevee max for CoGeNT) This result cannot exclude the possibility that the modulation observed by CoGeNT is due to electron-recoils. PRELIMINARY Singles Singles Multiples Contours: 68%, 95%, 99% PRELIMINARY PRELIMINARY Multiples 15

Conclusion Both CDMS and CoGeNT use Ge target: model-independent check of whether the reported CoGeNT modulating signal is due to (standard) WIMPs No significant evidence for annual modulation for nuclear recoils between 5-11.9 kev nr Annual modulation signal of CDMS and CoGeNT are incompatible at >95% C.L. for the full energy range No significant evidence for annual modulation for electron-recoil dominated sample in the same energy range (corresponding to 3 7.4 kev ee ), however little overlap with the energy range of CoGeNT A paper will be put on the archives in the coming few days SuperCDMS soon ready to take physics data! 15 larger (1 inch) detectors with double sided phonon-charge sensors installed in Soudan Detector commissioning on-going More in Enectali Figueroa-Feliciano s talk (Fri 11:10am)! 16

Extra slides

NR scale

Electron Recoil Background 1.3 kev line Compton Surface 2σ zero charge band Zerocharge

Limits without T1Z5 After removing T1Z5, the limits are ~30% worse at 8 GeV

Zero Charge Events Zero charge events seen in WIMP search singles, WIMP search multiples, and Ba calibration data with similar spectra

CDMS II exposure

Stability Cut Efficiencies Qinner NR band

Results: Nuclear Recoil Singles

Results: Electron-recoil-dominated Singles/Multiples