anion-exchange column

Similar documents
columns IonPac AS18 Anion-Exchange Columns

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

columns IonPac AS17-C Anion Exchange Column

Dionex IonPac AS28-Fast-4µm column

columns IonPac AS22 Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

columns IonPac SCS 1 Silica Cation Separator

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of trace anions in concentrated hydrofluoric acid

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

Determination of Trace Anions in Organic Solvents

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Determination of Inorganic Anions in Wastewater by Ion Chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

suppressors SRS -ULTRA Self-Regenerating Suppressor

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

High-Performance Chromatography Superior isocratic separation of

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Inline sample preparation for the determination of anions in sodium hydroxide

for IonPac AG11-HC IonPac AS11-HC

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Determination of Trace Anions in Concentrated Hydrofluoric Acid

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determination of Trace Anions in Concentrated Glycolic Acid

groups I and II cations, amines, divalent transition metals

The determination of trace anions in concentrated phosphoric acid

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

suppressors Eluent Suppressors for Ion Chromatography

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Determination of Cr(VI) in Water, Waste Water, and Solid Waste Extracts

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

IC Columns Introduction

IonPac Trace Cation Concentrator

Expanded capabilities in ammonium and amine detection

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Ion Chromatography: Green Chemistry for a Green Environment. Ken Kirkbride Somerset, New Jersey October 12, 2011

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Overcoming Challenging Matrices in Ion Chromatography

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

Determination of trace anions in high-nitrate matrices by ion chromatography

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Thermo Scientific Dionex eluent suppressors for ion chromatography

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Utility of the Charge Detector in Ion Chromatography Applications

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Determination of trace anions in concentrated glycolic acid

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

ION CHROMATOGRAPHY SYSTEM S 150

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Sample Preparation for Ion Chromatography

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

Determination of trace concentrations of oxyhalides and bromide in municipal and bottled waters

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of urea in ultrapure water by IC-MS/MS

4. Ion chromatography (IC) 4.1. Educational aims and objectives

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

IonPac SCS 1 IonPac SCG 1

Determination of trace anions in organic solvents using matrix elimination and preconcentration

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

IC5000 Ion Chromatography System

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts By Ion Chromatography

PRODUCT MANUAL. for the. IONPAC CG14 GUARD COLUMN (2 x 50 mm, P/N ) (4 x 50 mm, P/N )

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

ProPac WCX-10 Columns

Cation Exchange HPLC Columns

Determination of Adsorbable Organic Halogen in Wastewater

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Transcription:

columnsionpac ASA Anion-Exchange Column The IonPac ASA is a carbonateselective anion-exchange column designed for the fast separation of inorganic anions, including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate. Separation of these anions can be achieved in less than minutes using an isocratic carbonate/bicarbonate eluent. The IonPac ASA column offers excellent retention of fluoride out of the water dip and resolution of carbonate from chloride and bromate. Solvent compatibility permits easy column clean-up after the analysis of complex matrices. Superior Chromatographic Performance Fast, isocratic separation of inorganic anions and oxyhalides including chlorite, bromate, and chlorate in minutes. Superior retention and quantification of fluoride. Ideal for trace analysis of chloride and sulfate in high-carbonate samples. Meets or exceeds performance requirements of U.S. EPA Methods. (A) and (B). Compatible with organic solvents to enhance analyte solubility, modify column selectivity, or for effective column cleanup. Direct transfer of -mm applications to the -mm column format for more economical operation, threeto fourfold reduction in eluent consumption, and fourfold increase in mass sensitivity. Determination of Inorganic Anions in Diverse Sample Matrices Source water and drinking water Municipal and industrial wastewater Industrial cooling water Semiconductor devices Hazardous waste extracts and dump site leachates Acid rain Carbonated beverages Caustic samples Electronic grade reagents

High-Efficiency Particle Structure The IonPac ASA packing is a unique structure composed of a highly crosslinked core and a MicroBead anion-exchange layer attached to the surface, as shown in Figure. The substrate for the IonPac ASA column is a 9-µm diameter macroporous resin bead consisting of ethylvinylbenzene crosslinked with % divinylbenzene. The anion-exchange layer is functionalized with quaternary ammonium groups. The latex-bead anionexchange layer has a controlled thickness, which results in excellent mass-transfer characteristics and consequently, highly efficient peaks. Isocratic Separation of Inorganic Anions and Oxyhalides The IonPac ASA has been optimized for the fast, isocratic separation of inorganic anions and oxyhalides. Figure illustrates the isocratic separation of the common inorganic anions and oxyhalides in less than minutes using a carbonate/ bicarbonate eluent coupled with suppressed conductivity detection. Versatile Operation The IonPac ASA can be operated for fast analysis of inorganic anions using a. mm carbonate/. mm bicarbonate eluent as illustrated in Figure. Figure illustrates the flexibility of the ASA with a borate gradient for the resolution of fluoride, acetate, formate, and chlorite along with the common inorganic anions and oxyhalides. Determination of Inorganic Anions and Low Molecular Weight Organic Acids Low molecular weight organic acid and monovalent and polyvalent inorganic anions encountered in the chemical and power industries can be determined in a single run on the IonPac ASA. Figure illustrates an optimized separation of weakly retained anions, including fluoride, acetate, formate, and chlorite, using a borate linear gradient. Ethylvinylbenzene-Divinylbenzene Core Anion-Exchange Latex Coating -nm Diameter MicroBeads Figure. Macroporous resin with anion-exchange functionalized latex layer. Figure. Isocratic separation of inorganic anions and oxyhalides on the IonPac ASA column. Figure. High-efficiency IonPac ASA packing permits fast anion analysis. 9 9 Column: IonPac AGA, ASA, mm Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl Detection: Suppressed conductivity, ASRS, AutoSuppression recycle mode Peaks:. Fluoride. mg/l (ppm). Chlorite.. Bromate.. Chloride.. Nitrite.. Bromide.. Chlorate.. Nitrate. 9. Phosphate.. Sulfate. 9 9 Column: IonPac AGA, ASA, mm Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl AutoSuppression recycle mode Peaks:. Fluoride. mg/l (ppm). Chlorite.. Bromate.. Chloride.. Nitrite.. Phosphate.. Sulfate.. Bromide. 9. Chlorate.. Nitrate. 9

IonPac ASA for Anionic Contaminants on Semiconductor Devices The anionic contamination present on the surface of magnetic recording heads, also known as sliders, used in hard disk drives is a major determinant for whether the thin-film metallurgy will corrode during processing or subsequent use. Due to the small surface area of the samples, previous Ion Chromatography (IC) methods required measuring several sliders at a time and taking an average value. A new technique has been developed using microextraction followed by microbore IC to measure anionic contamination on a single slider. The slider is placed in an PEEK extraction cell body (/- x / in. i.d. inlet fitting and - ferrule style outlet fitting) and extracted with. ml DI water at. ml/min. for minutes and then concentrated on an AMC- MicroConcentrator column. The ASA column is used to separate the anionic contaminants on the surface of a single film slider. Figure illustrates the separation of anionic contaminants using a carbonate/bicarbonate eluent on a -mm IonPac ASA column. IonPac ASA for Inorganic Anions in Caustic Samples Anionic impurities in caustic soda (sodium hydroxide) and caustic potash (potassium hydroxide) are monitored by manufacturers and users for quality control of these products. Figure illustrates the separation of anionic contaminants in % caustic soda. Using an isocratic carbonate/bicarbonate eluent on the IonPac ASA column, chloride, chlorate, and sulfate can be determined in less than minutes. 9 Column: IonPac AGA, ASA, mm Eluent: Gradient from mm borate/. mm hydroxide to. mm borate/. mm hydroxide in min Flow Rate:. ml/min Inj. Volume: µl chemical suppression mode Peaks:. Fluoride. mg/l (ppm). Acetate.. Formate.. Chlorite.. Bromate.. Chloride.. Carbonate. Nitrite. 9. Bromide.. Chlorate.. Nitrate.. Phosphate.. Sulfate. Figure. Borate gradient separation of anions using the IonPac ASA column. Column: IonPac AGA, ASA, mm Conc. Column: IonPac AMC- Eluent:. mm Sodium carbonate/. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume:. ml,preconcentrated AutoSuppression external water mode Peaks:. Fluoride. ng/cm (calculated). Carbonate. Chloride.. Unknown. Unknown. Nitrate.9. Phosphate.. Sulfate. 9 Figure. Determination of anionic contaminants on thin-film sliders used in hard disk drives. Column: IonPac AGA, ASA, mm Eluent:. mm Sodium carbonate,. mm Sodium bicarbonate Flow Rate:. ml/min Inj. Volume: µl Sample prep: Diluted :, neutralized with ASRN AutoSuppression external water mode Peaks:. Chloride. mg/l (ppm). Chlorate.. Sulfate. 9 9 9 Figure. Determination of anionic impurities in caustic soda using the IonPac ASA column. The % caustic soda sample is diluted :, then neutralized using an ASRN AutoNeutralizer.

Rugged and Reliable Column Technology The highly crosslinked core of the IonPac ASA packing permits the use of HPLC solvents to alter column selectivity, control analyte solubility, facilitate column cleanup, and, more importantly, allows for the determination of inorganic anions in complex matrices. Figure illustrates the separation of trace-level anions in electronics-grade solvent using the IonPac ASA column. Column: Eluent: Flow Rate: Detection: Sample IonPac AGA, ASA, mm. mm Sodium carbonate/. Sodium bicarbonate. ml/min Suppressed conductivity, ASRS, AutoSuppression recycle mode. ml electronics-grade isopropanol concentrated on TAC-LP;. ml DI water wash Peaks:. Chloride. µg/l (ppb). Unidentified. Unidentified. Sulfate. 9 Figure Determination of anions in electronic-grade solvent using the IonPac ASA column. SPECIFICATIONS Dimensions: IonPac ASA Analytical Column: x mm and x mm IonPac AGA Guard Column: x mm and x mm Maximum Operating Pressure: psi Mobile Phase Compatibility: ph ; % HPLC solvents Analytical Column Substrate Characteristics: Bead Diameter: 9. µm Pore Size: Å Crosslinking (%DVB): % Analytical Column Latex Characteristics: Functional Group: Alkyl quaternary ammonium ion Latex Crosslinking:.% Latex Diameter: nm Hydrophobicity: Medium hydrophobic Capacity*: µeq ( x mm analytical column) µeq ( x mm guard column) µeq ( x mm analytical column) µeq ( x mm guard column) Column Construction: PEEK with - threaded, ferrule-style end fittings. All components are nonmetallic. * The IonPac AGA guard columns are packed with a microporous, pellicular resin and are optimized for concentration work. The guard latex is designed for trace-anion concentrator mehtods.

Ordering Information For optimum ease-of-use and economy, the IonPac ASA column should be used with the ASRS Anion Self-Regenerating Suppressor. For added ease-of-use, Dionex offers a. M Carbonate Eluent Concentrate and a. M Bicarbonate Eluent Concentrate and a line of anion standards to make your chromatography analysis even easier. Please refer to the part numbers listed or refer to the Dionex Product Selection Guide for more details. When performing gradient anionexchange applications on the ASA, an Anion Trap Column (ATC) should be installed between the gradient pump and the injection valve to remove anionic contaminants from the eluent. For -mm concentrator work, use the IonPac AGA guard column, TAC Anion Concentrator Column, or AMC- Anion MicroConcentrator when a single piston pump such as the DQP or DXP pump is used for sample delivery. Use the TAC-LP Anion Concentrator Column when the sample is delivered with a syringe or with a low pressure autosampler such as the AS or AS. For -mm concentrator work, use the IonPac AGA guard column or the AMC- Anion MicroConcentrator when a single piston pump such as the DQP or DXP pump is used for sample delivery. To order in the U.S., call () -9, or contact the Dionex Regional Office nearest you. Outside the U.S., order through your local Dionex office or distributor. Refer to the following part numbers. IonPac ASA Analytical Column ( x mm)...p/n IonPac AGA Guard Column ( x mm)...p/n IonPac ASA Analytical Column ( x mm)...p/n IonPac AGA Guard Column ( x mm)...p/n. M Carbonate Anion Eluent Concentrate ( ml; for use with... ASA column)...p/n. M Bicarbonate Anion Eluent Concentrate ( ml; for use with ASA column)...p/n ATC- Anion Trap Column (for use with -mm columns)...p/n ATC (-mm) Anion Trap Column (for use with -mm columns)...p/n TAC- Trace Anion Concentrator ( x mm)...p/n TAC-LP Trace Anion Concentrator ( x mm)...p/n AMC- Anion MicroConcentrator ( x mm)...p/n

IonPac, Anion Self-Regenerating Suppressor, AutoSuppression, and ASRS are registered trademarks and MicroBead and ASRN are trademarks of Dionex Corporation. Printed on recycled and recyclable paper with soy-based ink. Dionex Corporation Dionex Corporation Dionex U.S. Regional Offices Dionex International Subsidiaries Titan Way Salt Lake City Technical Center Sunnyvale, CA () - Austria () Belgium () Canada (9) -9 France 9 Germany -99- P.O. Box West South, Suite A Westmont, IL () 9- Italy () Japan () - The Netherlands () Switzerland () 99 United Kingdom () 9 Sunnyvale, CA Salt Lake City, UT Houston, TX () - * Designed, developed, and manufactured under an NSAI registered ISO 9 Quality System. 9-9- Atlanta, GA () - () - () 9-99 Marlton, NJ () 9- http://www.dionex.com LPN - M 9/99 999 Dionex Corporation