Hydraulic and Mass Transfer Performances of a Commercial Hybrid Packing: The RSP200X - Key Modelling Parameters for Gas Treatment Applications

Similar documents
Mass Transfer Rate Parameters of Sulzer EX Laboratory Scale Gauze Structured Packing

A Rate-Based Equation-Oriented Parallel Column Model: Application to Dividing Wall Columns

Numerical Simulation of Two-Phase Flow and Interfacial Species Transfer in Structured Packings

Supporting Information

Application of the Wallis Plot for the Determination of the Loading Limits of Structured Packings and Sandwich Packings

SEPARATION PERFORMANCE OF STRUCTURED PACKED COLUMNS: A COMPARISON OF TWO MODELLING APPROACHES

Study of Clear Liquid Height and Dry Pressure Drop Models for Valve Trays

SELECTIVE REMOVAL OF CARBON DIOXIDE FROM AQUEOUS AMMONIA SOLUTIONS

Simulation and Design of a Dividing Wall Column with an Analysis of a Vapour Splitting Device

CFD Modelling of the Fluid Flow Characteristics in an External-Loop Air-Lift Reactor

Removal of Carbon Dioxide from Indoor Air Using a Cross- Flow Rotating Packed Bed

Numerical Simulation of Film Flow over an Inclined Plate: Effects of Solvent Properties and Contact Angle

A Novel RTD Compartment Model for Tray Efficiency Predictions

Michael Schultes, Werner Grosshans, Steffen Müller and Michael Rink, Raschig GmbH, Germany, present a modern liquid distributor and redistributor

Production of a Green Multi-Purpose Fuel by Reactive Distillation

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Eulerian-Lagrangian Analysis of Multiphase Flow in Urea Prilling Process with Phase Changing

NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE TEMPERATURE DISTRIBUTION INSIDE OIL-COOLED TRANSFORMER WINDINGS

Indirect Series of Falling Film Distillation Column to Process Synthetic Naphtha

The Modified Analogy of Heat and Momentum Transfers for Turbulent Flows in Channels of Plate Heat Exchangers

Numerical Study on Heat Transfer Enhancement in a Rectangular Duct with V-Shaped Ribs

PHEx: A Computational Tool for Plate Heat Exchangers Design Problems

STRUCTURED PACKING EFFICIENCY VITAL INFORMATION FOR THE CHEMICAL INDUSTRY

CHAPTER 3 MODELLING AND ANALYSIS OF THE PACKED COLUMN

Comparison of the Heat Transfer Efficiency of Nanofluids

A MODIFIED MODEL OF COMPUTATIONAL MASS TRANSFER FOR DISTILLATION COLUMN

A Numerical Study of the Effect of a Venetian Blind on the Convective Heat Transfer Rate from a Recessed Window with Transitional and Turbulent Flow

A NEW PRESSURE DROP MODEL FOR STRUCTURED PACKING

Effect of External Recycle on the Performance in Parallel-Flow Rectangular Heat-Exchangers

Falling Film Evaporator: Drying of Ionic Liquids with Low Thermal Stress

CFD Investigation of Heat Transfer and Flow Patterns in Tube Side Laminar Flow and the Potential for Enhancement

Investigation of Packing Effect on Mass Transfer Coefficient in a Single Drop Liquid Extraction Column

Supplementary Information for Engineering and Analysis of Surface Interactions in a Microfluidic Herringbone Micromixer

Novel Control Structures for Heterogeneous Reactive Distillation

A New Batch Extractive Distillation Operational Policy for Methanol Recovery

Isopropyl Alcohol Vapour Removal from Diluted Gaseous Stream by Adsorption: Experimental Results and Dynamic Model

Analysis of Frictional Pressure Drop based on Flow Regimes of Oil-water Flow in Pipeline

Modelling interfacial heat transfer in a 2-phase flow in a packed bed

Compression and Expansion at the Right Pinch Temperature

Taking Reactive Distillation to the Next Level of Process Intensification

CFD SIMULATIONS OF FLOW, HEAT AND MASS TRANSFER IN THIN-FILM EVAPORATOR

Experimental and Numerical Investigation on Thermal Behavior of PCM in Storage Tank

Experimental Study on Port to Channel Flow Distribution of Plate Heat Exchangers

Evaluation of the Effect of Relative Humidity of Air on the Coefficients of Critical Flow Venturi Nozzles

Prediction of Viscosity of Slurry Suspended Fine Particles Using Coupled DEM-DNS Simulation

Thermodynamic model to study removal of Chlorine, Silicon Tetrafluoride and other uncommon materials from off gases

Condensation and Evaporation Characteristics of Flows Inside Three Dimensional Vipertex Enhanced Heat Transfer Tubes

Hybrid Separation Scheme for Azeotropic Mixtures Sustainable Design Methodology

Modeling and analysis of brake drum with extended fins on the

Biogas Clean-up and Upgrading by Adsorption on Commercial Molecular Sieves

VALIDATION OF CFD-MODELS FOR NATURAL CONVECTION, HEAT TRANSFER AND TURBULENCE PHENOMENA. J. Stewering, B. Schramm, M. Sonnenkalb

Part 1 Principles of the Fluid Dynamic Design of Packed Columns for Gas/Liquid Systems

Proppant Conductivity Analysis 40/70 Black Ceramic

Drum Burst due to Runaway Reaction and the Limits of MOC

Comparison of Conventional and Middle Vessel Batch Reactive Distillation Column: Application to Hydrolysis of Methyl Lactate to Lactic Acid

Comparison of Agitators Performance for Particle Suspension in Top-Covered Unbaffled Vessels

A Generalized Ease Of Separation Index for Selection of Optimal Configuration of Ternary Distillation

Particle resuspension

Design of A chemical Absorption System for The Separation of Propane/Propylene Mixture

Effect of Composition-Dependent Viscosity of Liquids on the Performance of Micro-Mixers

Rigorous Modeling of a CO 2 -MEA Stripping System

Thermal Decomposition Behavior of di-tert-butyl Peroxide Measured with Differential Adiabatic Calorimeter

A User-Defined Pervaporation Unit Operation in AspenPlus on the Basis of Experimental Results from Three Different Organophilic Membranes

Experimental study of gas-liquid heat transfer in a 2-phase flow in a packed bed

Mass Transfer II Prof. Nishith Verma Department of Chemical Engineering Indian Institute of Technology, Kanpur. Lecture No. # 9

MINIMIZATION OF ENTROPY GENERATION AND PRESSURE DROP FOR HYBRID WIRE MESHREGENERATIVE HEAT EXCHANGER

Physical modelling of the drained flow on a suction box of a papermachine

Three-dimensional Modelling of Reactive Solutes Transport in Porous Media

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

Numerical investigation of solid-liquid two phase flow in a non-clogging centrifugal pump at offdesign

INFLUENCE OF VAPOR FEED DESIGN ON THE FLOW DISTRIBUTION

CFD Simulation in Helical Coiled Tubing

Enhancement of Heat Transfer Effectiveness of Plate-pin fin heat sinks With Central hole and Staggered positioning of Pin fins

AQUEOUS SOLUTIONS OF PYRROLIDINE FOR CARBON DIOXIDE CAPTURE

Effect of the Type of Impellers on Mixing in an Electrochemical Reactor

Research Article Experimental Evaluation of Sulfur Dioxide Absorption in Water Using Structured Packing

Experimental and Numerical Investigation of Two- Phase Flow through Enlarging Singularity

Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions

MSWI Flue Gas Two-Stage Dry Treatment: Modeling and Simulation

Use of Stripping or Rectifying Trays for a Distributed Control Strategy in Distillation Column

Estimation of the Number of Distillation Sequences with Dividing Wall Column for Multi-component Separation

CFD Flow and Heat Transfer Simulation for Empty and Packed Fixed Bed Reactor in Catalytic Cracking of Naphtha

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

Mass Transfer in a Small Scale Flue Gas Absorber Experimental and Modeling

Module 9: Packed beds Lecture 29: Drag, particles settling. Flow through a packed bed of solids. Drag. Criteria of settling.

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

A Comparative Study of Carbon Capture for Different Power Plants

CFD-Modeling of Turbulent Flows in a 3x3 Rod Bundle and Comparison to Experiments

CFD Simulation of Turbulent Flow Structure in Stratified Gas/Liquid Flow and Validation with Experimental Data

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

MODELING AND EXPERIMENTAL STUDY OF CARBON DIOXIDE ABSORPTION INTO AQUEOUS AMINE BASED SOLVENTS

THE EFFECT OF TWO PHASE (AIR-WATER) FLOW CHARACTERISTICS ON MOMENTUM FLUX DUE TO FLOW TURNING ELEMENTS AT ATMOSPHERIC CONDITIONS

NUMERICAL SIMULATION OF FLUID FLOW BEHAVIOUR ON SCALE UP OF OSCILLATORY BAFFLED COLUMN

Numerical Analysis of Flow Dynamics of Cyclone Separator Used for Circulating Fluidized Bed Boiler

Turbulence Laboratory

Numerical simulations of hydrogen peroxide decomposition in a monolithic catalyst for rocket engines applications

A Rate-Based Equation-Oriented Parallel Column Model: Application to Dividing Wall Columns

Mahmood Bazmi*, Seyed Hassan Hashemabadi*,, and Mahmood Bayat**

Optimal Operation of Batch Reactive Distillation Process Involving Esterification Reaction System

A CFD study of gas-solid separation in a downer pyrolysis reactor: An eulerian-eulerian approach

Transcription:

A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 69, 2018 Guest Editors: Elisabetta Brunazzi, Eva Sorensen Copyright 2018, AIDIC Servizi S.r.l. ISBN 978-88-95608-66-2; ISSN 2283-9216 The Italian Association of Chemical Engineering Online at www.aidic.it/cet Hydraulic and Mass Transfer Performances of a Commercial Hybrid Packing: The RSP200X - Key Modelling Parameters for Gas Treatment Applications Pascal Alix a *, John Roesler a, Xavier Courtial b, Gauthier Perdu b, Michael Schultes c a IFP Energies nouvelles, BP 3, 69360 Solaize, France b PROSERNAT Tour PACIFIC, 11-13 cours Valmy, 92977, Paris La Défense Cedex, France c RASCHIG GmbH, Mundenheimer Straße 100, D-67061 Ludwigshafen, Germany pascal.alix@ifpen.fr The use of the last generation of Raschig s structured packings, Raschig SuperPack (RSP) has been investigated for scrubbing columns operating at high liquid loads, for their potential to increase capacity while maintaining mass transfer efficiencies at high levels. IFPEN has measured pressure drops, flooding limits, liquid and gas side mass transfer coefficients and interfacial areas for the RSP 200X. Flooding limits were in agreement with literature, however at high liquid loads and for tested X-Style RSP they were 30-40% lower than those calculated with the Winsorp Software. This indicates that extrapolation of flooding models should be used with caution to size column diameters for fluid systems and liquid loads that differ from those from which these models were derived. With the support of the present results a modified version of Winsorp has been elaborated for high liquid loads and X-Style RSP. RSP 200X develops a high interfacial area, close to the one of a standard 250 m 2 /m 3 structured packing. One important difference however has been noted about the impact of the gas flowrate on the interfacial area. While for standard packings the gas flow rate is often considered to have only a small effect on area when operating below the loading point, the effect measured on RSP200X is significant and of the same order as for liquid load. Measurements of k L a e further confirm that these latest generations of packings show different trends when compared to standard structured packings. Detailed characterization tests are therefore highly recommended to estimate the performances of these packings in terms of hydraulics and mass transfer properties. In some distant future, it is believed that CFD calculations (gas and gas/liquid) will help to better understand and model such phenomena. 1. Introduction The latest generation of Raschig s structured packings RSP (Raschig Super-Pak) can be considered for scrubbing columns operating at high liquid loads, for a potential to increase hydraulic capacity while maintaining intensive mass transfer efficiencies. RSP packings are more open than standard high capacity structured packings (see figure 1b), and for that reason they are usually called hybrid packings. The RSP200X (Schultes, 2017) is a relevant case study since it can develop an effective area close to the one of 250 m 2 /m 3 packings. In parallel it can handle high and wide range of liquid loads (from 10 to 120 m 3 /m 2 /hr). Experiments have been conducted with two different columns to measure hydraulic and mass transfer performances of the RSP200X. This paper gives some results that illustrate the performances of this hybrid packing, and highlights the need to consider the effect of gas flowrate on mass transfer rates. 2. Experimental facilities / methods Two test columns available at IFPEN premises in Solaize (France) have been used for this work. The first one is a 146 mm inner diameter stainless steel column with a 3 meter bed height. It operates at room temperature and pressures from 1.2 to 2 bar abs. Liquid loads, Q L, of 200 m 3 /m 2 /h, and gas load factors, F s, of 5 Pa 0,5 can be reached if needed. This first column will be called D146 in this manuscript. The second one is a 1000 mm inner diameter transparent column with a 3 meter bed height. It operates at room temperature and pressure.

Liquid loads of 100 m 3 /m 2 /h, and gas load factors of 4 Pa 0,5 can be reached if needed. This second column will be called D1000 in this manuscript. Both columns (D146 and D1000) are used for most of the measurements. Hydraulic parameters (pressure drop, flooding limits) have been measured with air/water system. Effective area, a e, has been measured with the absorption of CO 2 from air into NaOH (0,1N) system, which leads to a pseudo-first order fast chemical reaction (Wang, 2015, Hoffmann et al., 2007). Liquid side mass transfer coefficient, k L a e, has been measured by absorption of CO 2 diluted with air into a 3%wt MDEA solution (Roesler et al., 2016) which leads to a slow chemical reaction. Gas side mass transfer coefficient, k G a e, has been measured in the 146 mm column only, by absorption of SO 2 diluted with air into NaOH (2N) (Hoffmann et al., 2007) which leads to an instantaneous chemical reaction. For k G a e measurements, the bed height is reduced to 2 blocks (about 0.4 m), and a liquid pre-distributor is used. The experimental protocol has considered the end effects of the setup and they are subtracted in the conclusion: the k G a e had been determined from measurements with and without packing. For all measurements, gas and liquid concentrations are measured at column inlet and outlet. 3. Hydraulics performances Pressure drop and flooding limits were measured for Q L from 10 to 120 m 3 /m 2 /h. IFPEN measurements have been compared to the results of Wang (2015) and the calculations from two versions of the Raschig software: Winsorp and Winsorp 2017, the latter reflecting updates including this work. It should be noted that Wang used a 430mm inner diameter column with a bed height of 3.05 m. This column will be called D430 in this manuscript. As shown in Figure 1a for Q L =60 m 3 /m 2 /h, IFPEN and Wang results are in good agreement. The D146 results are a little bit staggered which indicates that there is not a major effect of diameter on the present measurements. Little by-pass at the wall and/or experimental error could explain a lower pressure drop with the D146 at F s =1,3 Pa 0,5. However, the study has a discrepancy between the results and the ones given by the early version of Winsorp software (before 2017) which over predicts flooding limits by 30-40%. Investigations with Raschig have shown that the software was based on distillation tests at the lower liquid loads only. The IFPEN tests have explored the higher loading rates and indicate that extrapolation of flooding models should be used with caution to size column diameters for fluid systems and liquid loads that differ from those from which these models were based on. With the support of the new results, a modified version of the software, Winsorp ( 2017 ), has been elaborated for high liquid loads and X-style RSP. Figure 1 indicates the performance determined in various IFPEN set-up s, by Wang, and tabulation by the two versions of Winsorp. a/ b/ Figure 1 : a/ Pressure drop of the RSP200X. Comparison of IFPEN measurements on D146 and D1000, with results of Wang (2015) on D430, and calculations of both Winsorp versions (original and revised in 2017). For Q L =60 m 3 /m 2 /h. b/ Pictures of RSP packings. 4. Mass transfer performances The experiment conducted at IFPEN has characterized the mass transfer parameters of RSP200X: interfacial area, mass transfer coefficients of the liquid phase, gas phase.

4.1 Effective area : a e Figure 2 gives the ratio of effective areas measured by IFPEN relative to those of Wang (2015, D430), as a function of the ratio Q L /Q L,ref for a fixed F s = 1,5 Pa 0,5. The latter is an intermediate value that is lower than the loading limit. It appears that IFPEN values can be considered in agreement with those of Wang since a 15% difference falls within typical experimental uncertainties (Hoffmann et al., 2007). However it has been found that the IFPEN values are systematically lower. Meanwhile, the figure 2 indicates that effective area measured in the D146 column is similar to the one measured in the 1000 mm column (within 5%). Therefore the difference with the results of Wang cannot be attributed either to a diameter effect or to a model effect (thermodynamics and kinetics models are identical). An effect of the liquid distributor (Wang uses a fractal liquid distributor) or a difference in the temperature used for the chemical reaction rate could explain such differences. Figure 2 : Ratio of effective areas measured by IFPEN (with D1000 and D146) and by Wang (2015) on the D430 as a function of the ratio Q L /Q L,ref, at F s = 1.5 Pa 0,5. Q L,ref =60 m 3 /m 2 /h. Figure 3 : Ratio of measured effective area to the one measured at F s = 0,65 Pa 0,5, as a function of F s /F s,ref at a fixed liquid load of Q L =60 m 3 /m 2 /h for IFPEN and Wang (2015) results.

For a fixed Q L =60 m 3 /m 2 /h, Figure 3 gives the ratio a e /a e,ref as a function of the ratio F s /F s,ref for both IFPEN and Wang (2015) results, where a e,ref is the effective area measured at F s = 0,65 Pa 0,5 at the respective columns. Figure 3 shows that the gas load impacts the effective area for the D430 and D1000 columns, a e could be increased by 20% (solid line). This was not expected since it cannot be explained by the hydraulics regime: the loading point is reached at F s = 2,3 Pa 0,5 for this liquid load (see Figure 1). The behaviour of the D146 is a little bit different, gas load effect is lower and not significant below a ratio of 2. This specific point has been explained by a moderate diameter effect. The impact of the gas load on the effective area has been observed for some random packings (Wang et al., 2005), however it is not common for structured packings. Hybrid packings like RSP200X are considered between random and structured packings, this could explain present results. This seems to indicate that, for some hybrid packings, an effect of the gas load should be considered to improve the accuracy of correlative models of mass transfer parameters. 4.2 Liquid side mass transfer : k L a e Figure 4 gives k L a e values measured by IFPEN as a function of the ratio Q L /Q L,ref, at F s = 1.5 Pa 0,5. Measurements are compared to those of Wang (2015). First, it should be noted that Wang uses the physical desorption of Toluene from water to measure k L a e. Thus the raw data from Wang should be corrected when the transfer of CO 2 is used in experimental tests of k L a e. In that purpose, the raw data are multiplied by the ratio of the square root of liquid diffusivities of Toluene and CO 2 into water, since there is no impact of the MDEA at 3%wt. Figure 4 shows that IFPEN and Wang measurements are in reasonable agreement. On the other hand, the values from the D146 column are significantly lower than those from D430 and D1000 columns. This confirms the existence of a significant diameter effect on the liquid phase, whereas only moderate size effects are seen on hydraulic and effective area measurements. The hydraulic diameter of the RSP200X mesh is close to 0.02 m, thus the ratio of the column to hydraulic diameter equals 7.3 for the D146. This value is lower than the one recommended by Olujic (1999) to eliminate size effects and could explain such results. Figure 5 gives the ratio of the experimental k L a e to the one measured at F s = 0,5 Pa 0,5, as a function of ratio F s /F s,ref. The liquid load is fixed, Q L =60 m 3 /m 2 /h. D1000 results have been selected since those from D146 are impacted by the column diameter. A gas load effect is clearly shown in Figure 6 where k L a e increases by more than 20% for F s = 2 Pa 0,5. This is coherent with effective area results, and confirms the need to consider a higher than usual gas load effect for structured packings. Figure 4 : k L a e as a function of the ratio Q L /Q L,ref, at F s = 1,5 Pa 0,5 corrected measurements. Q L,ref =60 m 3 /m 2 /h.. IFPEN measurements vs. Wang

Figure 5 : Ratio of k L a e with the one measured at F s = 0.5 Pa 0,5, as a function of F s /F s,ref and at Q L =60 m 3 /m 2 /h. IFPEN measurements (D1000). 4.3 Gas side mass transfer : k G a e The k G a e values have been measured in the D146 column (see chapter 2.). The IFPEN column is operated around 2 bar abs while the Wang column (2015) operates at atmospheric pressure. With these pressure differences, k G values cannot be compared directly. One should calculate the Sherwood number which considers the impact of the gas diffusivity, D G,SO2 : For the present structured packing :, (1) 4 (2) a g is the geometric specific area of the RSP200X, which is equal to 200 m 2 /m 3. It must be noted that IFPEN k G values have been calculated by dividing k G a e with interfacial areas measured in the D146 column which differ slightly from those measured with the D1000 column (see 4.1) but are coherent with the k G a values. Figure 6 gives the Sherwood number as a function of the gas Reynolds number, and compares IFPEN values to those of Wang (2015). The gas Reynolds number takes into account the impact of the pressure on the hydraulics : (3) Where G is the gas dynamic viscosity (Pa.s), and G is the gas density (kg/m 3 ). Figure 6 shows that IFPEN measurements are in good agreement with Wang measurements. This indicates that there is a negligible diameter effect on k G which was not the case for the k L (see 4.2). The present measurements could therefore be used to build correlations for bigger columns. At Re G =3000, the Wang value is not in agreement with other ones and seems to be too low. This could be explained by the fact that at such high gas flowrates the SO 2 concentrations in the gas leaving the packing bed become very low such as to generate higher experimental errors. Upon extrapolation to the intercept, the Sherwood number follows a power law dependency of 0,83 relative to the gas Reynolds number, which is in agreement with a majority of publications that recommend 0,8 (Wang et al., 2005). This also confirms the fact that there is no significant diameter effect on present results.

Figure 6 : Gas Sherwood number as a function of the gas Reynolds number. IFPEN measurements (D146) vs. Wang measurements (D430, 2015). 5. Conclusions Experiments with the RSP200X Raschig hybrid structured packing have been performed in two test facilities with respective inner diameters of 146 and 1000mm. Pressure drop, flooding limits, and mass transfer parameters have been measured with system models. Hydraulics tests show that extrapolation of available flooding models should be used with caution to size column diameters, for fluid systems and liquid loads that differ from those from which these models were derived. With the support of present results, a modified version of Winsorp ( 2017 ) has been elaborated by Raschig for high liquid loads and X-style RSP. Mass transfer tests show that a gas velocity effect should be consider on interfacial area of hybrid packings like RSP, which was not expected for any structured packing. This is confirmed by k L a e measurements. A diameter effect is highlighted for the D146 column, however this effect is on the liquid phase only (k L ). For the gas phase (k G ) this diameter effect becomes negligible. Finally, the present test results are in good agreement with those of Wang obtained with a 430 mm inner diameter column and other system model used to determine k L a e. References Hoffmann A., Mackowiak JF., Gorak A., Haas M., Löning JM., Runowski T., Hallenberger K., 2007, Standardization of mass transfer measurements. A basis for the description of absorption processes, Chem Eng. Res. And Design, 85(A1), 40-49 Olujic Z., 1999, Effect of column diameter on pressure drop of a corrugated sheet structured packing, TransIChemE, 77, 505-510. Roesler J, Royon-Lebeaud A, Alix P. Liquid side mass transfer coefficient measurements in tall structured packing beds by reactive absorption with dilute MDEA solutions. Paper Presented at 2016 AIChE Annual Meeting, San Francisco, CA, USA, November 13-18, 2016, Paper n 8467941. Schultes M., 2017, Raschig Super Pak. A new packing structure with innovative advantages. Product Bulletin 501. Wang GQ., Yuan XG., Yu KT., 2005, Review of mass transfer correlations for packed columns, Ind. Eng. Chem. Res., 44, 8715-8729 Wang, 2015, Mass transfer coefficient and effective area of packing. Thesis manuscript, The University of Texas.