The electron accelerator of the ISOF-CNR Institute: its characteristics and use

Similar documents
Energy device for monitoring 4-10 MeV industrial electron accelerators

Energy Monitoring Device for Electron Beam Facilities

Industrial Irradiators for Radiation Processing

Soft Breakdown in Ultra-Thin Gate Oxides

Industrial Applications of Accelerators: Traditional and new

Epitaxial SiC Schottky barriers for radiation and particle detection

PECULIARITIES OF FORMING THE RADIATION SITUATION AT AN AREA OF NSC KIPT ACCELERATORS LOCATION

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Estec final presentation days 2018

Research Laboratory for Quantum Beam Science

Introduction to Power Semiconductor Devices

Activities at the Calliope facility at ENEA - Casaccia

APPLIED RADIATION PHYSICS

Radiation exposure of personnel during IORT: radiation protection aspects.

Chapiter VII: Ionization chamber

Determination of Ambient Dose Equivalent at INFLPR 7 MeV Linear Accelerator

ATL-INDET /04/2000

Test Simulation of Neutron Damage to Electronic Components using Accelerator Facilities

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Instrumentation for Verification of Dose

Simulation of Radiation Effects on Semiconductors

Semiconductor Detectors

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

Introduction to Radiation Testing Radiation Environments

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

X-Rays From Laser Plasmas

Instrumentation for Verification of Dose

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

ICALEPCS Oct. 6-11, 2013

Irradiation by Ionizing Radiation Comparison of Ebeam, Xray with Gamma

TPC8116-H TPC8116-H. High Efficiency DC/DC Converter Applications Notebook PC Applications Portable Equipment Applications CCFL Inverter Applications

DESIGN AND CONSTRUCTION OF LOW ENERGY ELECTRON ACCELERATORS AT SINP MSU

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Chapter V: Cavity theories

Final Examination EE 130 December 16, 1997 Time allotted: 180 minutes

General characteristics of radiation dosimeters

Modern physics ideas are strange! L 36 Modern Physics [2] The Photon Concept. How are x-rays produced? The uncertainty principle

Sheng S. Li. Semiconductor Physical Electronics. Second Edition. With 230 Figures. 4) Springer

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Dielectric Wall Accelerator (DWA) and Distal Edge Tracking Proton Delivery System Rock Mackie Professor Dept of Medical Physics UW Madison Co-Founder

Investigation of dose rate effects in radiation chemistry with laser-driven pulsed sources at ELI Beamlines

Occupational Radiation Protection at Accelerator Facilities: Challenges

EXAMINATION QUESTIONS (6)

Spawning Neutrons, Protons, Electrons and Photons from Universities to Society

Diagnostics for Burning Plasma Physics Studies: A Status Report.

Test Simulation of Neutron Damage to Electronic Components using Accelerator Facilities

MMIX4B22N300 V CES. = 3000V = 22A V CE(sat) 2.7V I C90

ELECTRON INTERACTIONS

Basic physics Questions

Control of the fabrication process for the sensors of the CMS Silicon Strip Tracker. Anna Macchiolo. CMS Collaboration

Simulation Modeling in Dosimetry

Radiation Detection and Measurement

THE USE OF IONISING RADIATION IN THE MANUFACTURE OF MEDICINAL PRODUCTS

Results from Silicon Photo-Multiplier neutron irradiation test

Radiation damage considerations in accelerator beam environments

7. a XV-2 high spatial resolution lm detector (Kodak). Important parameters of these detectors are given in Table1. The ionization chambers and the di

Radiation Effect Modeling

TOSHIBA Field Effect Transistor Silicon P Channel MOS Type (U-MOSⅣ) TPC8114. DC (Note 1) I D 18 A Pulse (Note 1) I DP 72

Device 3D. 3D Device Simulator. Nano Scale Devices. Fin FET

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

Power semiconductor devices

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

Neutron Dosimetry with Ion Chamber-Based DIS System

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type (Ultra-High-Speed U-MOSIII) TPC8017-H

Semiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH

Quality Assurance. Purity control. Polycrystalline Ingots

COST MP0601 Short Wavelength Laboratory Sources

Jeancarlo Torres, CHP. Naval Surface Warfare Center Carderock Division

Chapter 9: Calibration of Photon and Electron Beams

Towards Proton Computed Tomography

S5p INTENTIONALLY BLANK

Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility

Optical and THz investigations of mid-ir materials exposed

4. Inelastic Scattering

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

TOSHIBA Field Effect Transistor Silicon N-Channel MOS Type (U-MOSⅤ-H) TPC8037-H

MSN551 LITHOGRAPHY II

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type (π MOSIII) 2SK2610

Correction of the electric resistivity distribution of Si wafers using selective neutron transmutation doping (SNTD) in MARIA nuclear research reactor

Development of a Radiation Hard CMOS Monolithic Pixel Sensor

New Functions. Test mode and Specimen failure. Power cycle test system with thermal analysis capability using structure function.

MIL-STD-883E METHOD THERMAL CHARACTERISTICS

Neutron Metrology Activities at CIAE (2009~2010)

TOSHIBA Field Effect Transistor Silicon P Channel MOS Type (U-MOS III) TPCF8102

Electrical Characterization with SPM Application Modules

ARACOR Eagle- Matched Operations and Neutron Detector Performance Tests

Thermal and Electrical Breakdown Versus Reliability of Ta2O5 under Both Bipolar Biasing Conditions

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type (U-MOS IV) TPC8028

TOSHIBA Field Effect Transistor Silicon N-Channel MOS Type (Ultra-High-speed U-MOSIII) TPCA8011-H

Development of Radiation Hard Si Detectors

LET! (de / dx) 1 Gy= 1 J/kG 1Gy=100 rad. m(kg) dose rate

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

Centre for Electronic Imaging

MMIX4B12N300 V CES = 3000V. = 11A V CE(sat) 3.2V. High Voltage, High Gain BIMOSFET TM Monolithic Bipolar MOS Transistor

Defining quality standards for the analysis of solid samples

A 6 GeV Compact X-ray FEL (CXFEL) Driven by an X-Band Linac

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Transcription:

The electron accelerator of the ISOF-CNR Institute: its characteristics and use P. Fuochi, U. Corda, and M. Lavalle ISOF-CNR Institute, Via P. Gobetti 101, I-40129 Bologna, Italy LINAC Laboratory: ISOF-CNR, Via Biancafarina 2485, 40060 Fossatone di Medicina (BO) Italy

The electron accelerator The Institute of Photochemistry and High Energy Radiation (now merged into the Institute for Organic Synthesis and Photoreactivity) was established in 1970 in Bologna. One of the main tasks of the Institute, which became the main reference centre for radiation chemistry in Italy, was to perform basic and applied research in the field of the effects and application of ionizing radiation. For this purpose the Institute was equipped with 60 Co γ-sources and a 12 MeV linear electron accelerator. The 12 MeV linear accelerator (maximum energy with no load), built by Vickers, came into operation in 1973. It is an L-band (i.e. working at a radiofrequency of 1.3 GHz) travelling wave accelerator operating in the π/2 mode. The electron beam is pulsed and the pulse width can be varied from 10 ns to 5 µs with a repetition rate from single shot up to 1000 pps. Thus the accelerator can be used in single shot or in continuous mode and a pulse counter allows the delivery of any preset number of pulses. Pulse to pulse reproducibility is within ± 2% per day. The maximum current (peak current) obtainable is between 5 and 7 A with 10 ns pulses and 1 A for long pulses (µs). The most probable energy of the electrons is 11 MeV for pulses between 10 and 100 ns dropping to 8 MeV at 2 µs. The beam energy can be varied by changing the pulse width and/or the average beam current. The typical configuration for routine irradiation is: pulse repetition rate: 50 Hz average beam current: 100 µa pulse length: 2 µs peak pulse current: 1 A electron energy: 8 MeV Since there is no scanning system, in order to obtain good uniformity of dose distribution ( ±10%) on the sample under irradiation, aluminium scatter plates are used to spread the beam for samples having dimensions 110 cm 2, while for samples up to 40 x 40 cm, a computer driven x-y moving system is used to move these samples in front of the accelerator window.

The 12 MeV Vickers linear accelerator. View of the accelerating waveguide. The accelerator s and the klystron s rooms are shielded with a copper Faraday cage to avoid electronic noise in the irradiation room. Scheme of the LINAC

Energy spectra for the 10 ns, 1 µs and 2 µs beam pulses. Beam current, arbitrary unit 1 0.8 0.6 0.4 0.2 2 µs 1 µs 10 ns 0 6 7 8 9 10 11 12 13 Beam energy (MeV) Depth-dose curves measured at 90 cm from the LINAC, scatterplate= 0.9 mm Al 1.6 1.4 1.2 1 0.2 µs pulses E p = 11.5 MeV Depth dose distributions measured using the wedge technique. Dose, a.u. 0.8 0.6 2 µs pulses E p = 8 MeV 0.4 0.2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 mm in Al

Dosimetry and irradiation process control A graphite charge collector is used to monitor the beam current and the electron fluence (e /cm 2 ). The collected charge is led to a charge detection system placed outside the irradiation room and displayed on a digital counter. Calibration against the modified Fricke chemical dosimeter allowed direct conversion of the collected charge (e /cm 2 ) to absorbed dose (Gy). The modified Fricke chemical dosimeter is also the reference dosimeter for the calibration of radiochromic films which are used as routine dosimeter. Alanine pellets are used as transfer dosimeter in intercomparison dose measurements with other laboratories. An energy monitor allows to measure the energy of the beam. Routine measurements of the beam energy and the fluence, and hence of the dose, are done regularly before and after each irradiation sequence. 20 18 16 14 Dose (Gy/pulse) 12 10 8 6 4 2 The graphite charge collector. 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Fluence (10 10 e - /cm 2 pulse) Calibration curve for the graphite charge collector vs. absorbed dose in super Fricke solution.

e - 100 mm To the digital current integrators 2. Connected to ground Ceramic pillars Wall thickness: 10 mm Aluminium cage dimensions: (14cm x 14cm x 10cm) 1. 0.95 0.90 0.85 long pulses (0.5-5 µs) short pulses (0.05-0.5 µs) 3. Energy ratio 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 E p (MeV) 1. front view of the energy device 2. cross-sectional view of the energy device 3. calibration curves for the energy device

Applied radiation research using the 12 MeV Linac The electron accelerator is used in a number of researches and tests connected to industrial applications which are listed below. 1. Treatment of food products and pharmaceuticals. Some studies have been conducted in this field to evaluate the effectiveness of electron irradiation in decontamination of pharmaceuticals, spices and poultry meat from pathogenic micro-organisms. 2. Curing of composites. Thick composite materials made of carbon fibres in organic matrices (epoxy resins) have been cured with high-energy electron beams. The polimerization of the methylmethacrylate in presence of rubber is under study.

3. 1. 4. 2. COMPOSITE MATERIALS. 1. and 2.: glass fibres and epoxy resins layers, aluminium honeycomb structure inside 3. and 4.: carbon fibres and epoxy resins layers, aluminium honeycomb structure inside 5. 5. epoxy resin and carbon fibres composite

Applied radiation research using the 12 MeV Linac 3. Sterilization of human bone tissues for implants. Femoral heads are sterilized to be used as biocompatible material in prosthesis implants, skull fragments are sterilized before their implants in the same patient.

1. 2. HUMAN BONE STERILIZATION. 1. disposable container for surgical specimen 2. the hermetic envelope, whit the container, is in front of the LINAC window, ready for the irradiation

Applied radiation research using the 12 MeV Linac 4. Modification of semiconductor devices. Starting from 1982, research in the field of electron irradiation of power semiconductor devices has been conducted at FRAE Institute (now ISOF). In collaboration with Italian power semiconductor manufacturing industries an extensive program of irradiation tests have been undertaken. Fast switching diodes and thyristors, Gate Turn Off thyristors (GTO), power MOS transistors and Insulated Gate Bipolar Transistors (IGBT) were irradiated with electron beams at different doses in order to achieve modelling of the electrical parameters and specific adjustment of carrier lifetime. The results led the above mentioned firms to introduce this technology for series production in place of the conventional high-temperature heavy metal diffusion for lifetime control. Equipment and methods for series production have been developed, tested and since 1986 put into operation

MODIFICATION OF SEMICONDUCTOR DEVICES. 1. silicon wafers 2. the system for the power semiconductor irradiation 3. power semiconductor devices in the process load unit 1. 2. 3.

MODIFICATION OF SEMICONDUCTOR DEVICES. 1. silicon slice for thyristor 2. finished device: thyristor 3. and 4. final device set up: 3. stud case 4. press pack case 1. 2. 3. 4.

Applied radiation research using the 12 MeV Linac The linac is also used to perform irradiation tests on MOS devices with ultra-thin oxides. Present studies, conducted in collaboration with the Dept. of Physics and Dept. of Electronics and Informatics of the University of Padova, on total dose effects (devices were irradiated up to 150 Mrad) include measurements of radiation induced leakage current (RILC) and soft breakdown in gate oxides MOS capacitors. These studies have demonstrated that the RILC in these devices is due to neutral traps generated in the oxide during irradiation and that RILC conduction mechanism can be explained by a sort of electron tunnelling through gate oxide assisted by radiation induced neutral traps. These results, obtained using the linac as electron source, are similar to those obtained with γ-, x-rays and high energy ions with LET<10 MeVcm 2 mg -1. The use of a linac in place of gamma cells (usually used for total dose experiments) results to be more convenient because of the reduced time to reach high doses necessary to study the RILC phenomenon.

X-Ray generation A water-cooled tantalum converter is used to produce X-rays. The target thickness (1.5 mm) has been selected in order to optimise the bremsstrahlung production using the 2µs pulses.

1 150 120 90 X-Ray distribution Polar distribution of the forward X-ray emission from the converter. dose, a.u. 0 180 e - 210 1 240 270 1 0.9 dose, u.a. 0.8 0.7 0.6 X-Ray penetration Depth-dose profile of the bremsstrahlung beam. 0.5 0.4 0.3 0 10 20 30 g/cm 2

LICHTENBERG TREES IN PMMA CILINDERS. The Lichtenberg tree effect is the electrical discharge pattern resulting from an instantaneous breakdown of an electrical field. The field results from the rest of high-speed electrons injected into the material. When the field exceed the insulating strength of the material a local discharge occurs whit consequent damage on the material itself.