рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Similar documents
PAA-ANALYZERS PRINCIPLE OF OPERATION

Zetasizer Nano-ZS User Instructions

Automatic titrators, TitroMatic

Dewpoint Meter Data Sheet / Instructions

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Data Sheet / Instructions. Dewpoint MeterO

O P E R A T I N G M A N U A L

Chemistry MultiMeasure Sensor PS-2170

473-SHX Dew Point Mirror

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

Dielectric Analysis of Insulation Liquids

REVIEW OF LAB TECHNIQUES

MEASUREMENT: PART II

Process Instrumentation analyzers

10 samples per second

The Determination of an Equilibrium Constant

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

SILICA, Low Range SiLR

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Instruction Manual HI Refractometer for Sodium Chloride Measurements

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

473 Dew Point Hygrometer

Dielectric Analysis of Solid Insulations

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Kinetics of Crystal Violet Bleaching

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Bright Advance Corporation

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

REVIEW OF LAB TECHNIQUES

WeatherHub2 Quick Start Guide

Acceleration/Velocity/Displacement VIBRATION METER

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

473 Dew Point Hygrometer

Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Microscale Acid-Base Titration

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

Circular Motion and Centripetal Force

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

CTC 155 / 350 / 660 Dry-block calibrator

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Bante210 Benchtop ph Meter Instruction Manual

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Determining the Conductivity of Standard Solutions

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Determining the Concentration of a Solution: Beer s Law

PiCUS Calliper Version 3

Determining the Concentration of a Solution: Beer s Law

OPERATING MANUAL. EIB-Kombisensor AS 315 N

AIRBIO : AIRBONE DISINFECTION

3B SCIENTIFIC PHYSICS

iworx Sample Lab Experiment GB-2: Membrane Permeability

Residual Chlorine Monitor

IV. EQUIPMENT a. Horiba LA 950 main unit b. Dry sample unit that has a silencer behind it c. Cell slide unit that holds

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

INE-PHS-3E ph Meter Operating Manual

Instruction Manual. Qubit Fluorometer. probes.invitrogen.com/qubit

JAPAN QUALITY. Automated Clinical Analyzer

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Mini Environmental Quality Meter

PC Control / Touch Control

VIBRATION METER. Instruction Manual.

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

MODELS Number WW4.x For Europe & Others V 50HZ

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

PRELIMINARY ACTIVITY FOR

High Resolution High Sensitivity SDR Super Wide Dynamic Camera

University of Minnesota Nano Center Standard Operating Procedure

Photosynthesis. LabQuest OBJECTIVES

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Operating Instructions for Digital Manometer. Model: MAN-SD

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

TitriSoft 2.5. Content

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Spectrometer User s Guide

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

Getting started with BatchReactor Example : Simulation of the Chlorotoluene chlorination

JAPAN QUALITY. Automated Clinical Analyzer

HI Propylene Glycol Refractometer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Operating Instructions. Titration Excellence Terminal

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

Transcription:

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically Complete Set ph PRO Controller - 1 pcs. ph electrode - 1 pcs. Calibration solution ph 4.01 and ph 7.01 Tube with micro-fittings - 4 pcs. Suspended fixture - 2 pcs Microprocessor control Automatic ph level control Automation of hydroponics 1 из 7

Content The device and its functions...3 Technical feature...3 Connection...4 Settings...4 Display symbols...5 ph level setting (hysteresis)...5 Manual control...5 Settings...6 Calibration...6 Settings by default... 7 Warranty... 7 Operation conditions... 7 2 из 7

E-MODE phph controller ph+ IN OUT IN OUT From the reagent container To the hydroponic system Device 2 peristaltic pumps Graphic display and keyboard to set the device Traditional PI-regulator ph electrode to measure рн level Measuring range: 0~14 ph Operating temperature: 0~80 C Store electrodes in a special solution to avoid their drying. To clean electrodes from sediments use electrode cleaner. Not to damage the electrode use a sampler. Do not place electrode s cable into a solution. Sampler s pump should work continuously. WARNING! It is important to check peristaltic pump operation with the first start in the manual mode. To turn to automatic mode it is necessary to fill in ph regulators tubes in a manual mode. Functions ph level measurement and its regulation(with any liquid on the basis of PI-law and peristaltic pump) Displaying current ph level measurements Manual addition of reagents (ph up and ph down) according to set dosing Technical feature Tank volume - 10-2000 L Dosing pause - 0,5-48 h. Уровень ph - от 3.0 до 14.0 Manual dosing - up to 50 ml Language: Russian, English Voltage: 220-240 V Current frequency: 50 hz Power consumption: 10 W Dimensions: 100 х 200 х 150 mm Protection: IP64 Weight: 1,8 kg 3 из 7

рн Controller 220V PH ELECTRODE ph - ph + TANK WITH SOLUTION WARNING! Reagents (acid ph down, alkali ph up) should be used as solution 20% - 30%. More concentrated reagents can disable the device! Recommendations: Do not setup ph hysteresis below 0.5, as it can complicate nutrient absorption, even lead to plants death and reagents overuse. Connection Place the device anywhere 1,5m far from the tank (ph sensor cable 2m). Place the electrode into the tank (see pic.) If the system is more than 200L make active circulation inside the tank with a nutrient solution. Place the pumps hoses into the tank with solution/water. Connect the other 2 hoses with the pumps input; the other ends of the hoses should be placed into the bottles with acid and alkali according to the pumps marking on the panel. Then plug in the device (220V). Then setup a necessary to maintain ph level (point 2) and tank volume (point 4.2). Settings When the device is plugged in, then the display shows logo, and operating mode is on. 4 из 7

regulator mode ph level dosage scales 1. Display Symbols «A» in the upper left corner means the device is in automatic mode and reagents are added automatically when needed. If automatic mode is off, «A» is changed for «M», and the reagents will not be added, only current ph level is displayed. Under the current ph level on the display it is shown the ph level maintained by the device. The picture shows the device is set to maintain hysteresis (lower and upper ph levels) from «LO» - 5,5 to «HI» - 6,5 (recommended by default). Hysteresis setup is described in point 2. The scales of reagents dosing are displayed on the right. If both scales are empty, then ph level is fine. If one of the scales is colored (see pic.), then one of the reagents is periodically added (in this case ph up). The extent of scale coloring indicates the dose volume of the reagent. At the bottom of the screen there is a menu bar. To enter menu, press «ОК», the first window in the menu bar is highlighted. This window is to enter ph hysteresis setup. To move in the menu bar, use and. ph difference settings 2. Setting ph (hysteresis) Select ph level setting window in the menu bar and press «ОК» again. Set upper ph level, then with button turn to lower ph level setting and set a lower ph level. Upper ph level should be higher than the lower one. The ph range of the solution is maintained within this range. You can move in the menu with button only. To exit ph level settings place cursor on «Exit» and press «ОК» button. ph level volume of reagent dosage scales regulator selection 3. Manual control Manual control mode is used to dose reagents manually. Available dosing: 1-10ml. Highlight the line with in the menu bar (middle window). Press «ОК» to open the window of manual control. The window on the left displays current ph level, and below selected dosage. 2 graphic scales on the right show selected dosage for both reagents. Select a necessary reagent and its dosage, press «ОК», a corresponding pump turns on to add a selected reagent into solution. To exit this mode, turn to Exit in the menu bar and press «ОК». 4. Settings With in the menu bar select middle window and press «ОК» to open Settings window. 4.1. Select language You can select Russian or English. 5 из 7

4.2. Controller settings You can setup parameters and modes for control and regulation. The first line is to setup tank volume to maintain a set ph level in. Available volume: 20-200L. The second line is to setup dosing interval: 0,5 48 hours. The third line is to select controller s mode: on/off. 4.3. Calibration It is recommended to check the accuracy of the device readings once in half a year. To calibrate and check the device different solutions can be used, but their ph level should not be lower than 3.5 and higher than 12. It is recommended that the difference of upper and lower levels of solutions should not to be less than 3. The complete set includes 2 calibration solutions: ph 4,01 and ph 7,01. NOTE! The device is calibrated and use-proven before sell! IMPORTANT: operating temperature should not exceed 27 С when calibrating. RECOMMENDATIONS: To calibrate with the calibrating solutions included open the packs with those calibrating solutions. Pour the solutions into the bottles with hermetic plugs and mark their ph level. Sink the electrode into the First solution and keep it there for one minute. Compare the ph level of the solution with the data of the device. Rinse the electrode with tap water and wipe it dry. Then do it step by step again with the second solution. If the data you get and those of the device differ no more than +/- 0.3 ph, then the readings of the device are correct. Calibration Select «Low ph level» in the menu and sink the electrode into the solution with the lower ph, then with and ph buttons set the ph level of the solution you use, wait until the readings of the indicator (upper line) stops changing or changes within minimum levels. Take the electrode out of the calibrating solution, rinse and wipe it. After that, pressing button, select «High ph level» and sink the electrode into the solution with high ph. Set the readings of the second solution. Also wait till the readings of the indicator stops changing and select «Save», press «OK» button. The ph level of the solution the electrode is put in should be displayed near the indicator. If you want to get back the initial settings, then get to a corresponding option and press «OK». Calibration is finished. NOTE! While calibrating do not touch the electrode or its cable. Exactly follow the instructions in the user manual. Do not take the electrode from the first calibrating solution until «Upper ph level» gets to the second menu point. 6 из 7

Settings by default: Tank volume: Dosing pause: Automatic mode: 20L 1 min on Warranty Warranty period: 1 year since the day of purchasing. Free service and warranty repair is carried out by the specialists of E-mode laboratory. The address of the authorized service center: Russia, 614099 Perm, Dzerzhinskii Str. 59, office 405. The warranty is valid in case the operation conditions are complied with and there is a seller s stamp with the date of purchasing. Operation conditions Working with fertilizers and ph regulators use personal protection equipment. Operation temperature (of the environment): 0 С - 45 С Operation humidity level: 0% - 90%. The device is not waterproof, protect it from moisture. Use voltage regulator to avoid power surges in the mains. Voltage (admissible range): 220 2240V. AC frequency (admissible range): 50 hz / 47...63 hz. Keep the device and its spare parts out of reach of children. Sale date/stamp Serial number 7 из 7