METHODOLOGY (3) where, x o is the heat source separation and α is the. entrainment coefficient α.

Similar documents
CFD MODELLING OF PLUME INTERACTION IN NATURAL VENTILATION 3TU, UK

Atrium assisted natural ventilation of multi storey buildings

Numerical studies on natural ventilation flow in an enclosure with both buoyancy and wind effects

Chapter 7. Three Dimensional Modelling of Buoyancy-Driven Displacement Ventilation: Point Source

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

GUIDANCE ON THE USE OF COMPUTATIONAL FLUID DYNAMICS FOR MODELLING BUOYANCY DRIVEN FLOWS

Plumes and jets with time-dependent sources in stratified and unstratified environments

Evaluation of LES and RANS CFD modelling of multiple steady states in natural ventilation

Buoyancy-driven ventilation between two chambers

A NEW MODEL FOR ESTIMATING NEUTRAL PLANE IN FIRE SITUATION

OpenFOAM selected solver

FIRE SAFETY DESIGN USING LARGE EDDY SIMULATION MODELS: EME BUILDING OF BUET: A CASE STUDY

Tutorial for the heated pipe with constant fluid properties in STAR-CCM+

REDUCING COMPUTATIONAL TIME IN TURBULENT JET MODELLING FOR GAS DISPERSION SIMULATION

Calculating equation coefficients

USE OF CFD TOOL ANSYS FLUENT FOR FIRE SAFETY IMPROVEMENT OF AN INDOOR SPORTS ARENA

EXPERIMENTAL SETUP The experimental test-room was representative of a full-sized office space. This was a natural

SIMULATION OF PRECESSION IN AXISYMMETRIC SUDDEN EXPANSION FLOWS

INTERNAL FLOW IN A Y-JET ATOMISER ---NUMERICAL MODELLING---

Natural Convection Heat Loss from A Partly Open Cubic Enclosure Timothy N Anderson 1,a * and Stuart E Norris 2,b

Transient natural ventilation of a room with a distributed heat source

Air Flow Modeling in a Mechanically Ventilated Room

Hydrogen Vehicle Leak Modelling in Indoor Ventilated Environments.

Tutorial for the supercritical pressure pipe with STAR-CCM+

CFD as a Tool for Thermal Comfort Assessment

NUMERICAL AND EXPERIMENTAL INVESTIGATIONS OF AIR FLOW AND TEMPERATURE PATTERNS OF A LOW VELOCITY DIFFUSER

A Numerical Investigation on Active Chilled Beams for Indoor Air Conditioning

TURBULENCE MODELING OF AIR CIRCULATION IN AN ENCLOSURE WITH MULTIPLE OPENINGS AND LOCAL HEAT SOURCES

THE RESPONSE OF A PLUME TO A SUDDEN REDUCTION IN BUOYANCY FLUX

Comparison of two equations closure turbulence models for the prediction of heat and mass transfer in a mechanically ventilated enclosure

INTER-COMPARISON AND VALIDATION OF RANS AND LES COMPUTATIONAL APPROACHES FOR ATMOSPHERIC DISPERSION AROUND A CUBIC OBSTACLE. Resources, Kozani, Greece

Numerical simulation of Helium dispersion in a semi-confined airfilled

GENERALISATION OF THE TWO-SCALE MOMENTUM THEORY FOR COUPLED WIND TURBINE/FARM OPTIMISATION

NUMERICAL MODELLING OF TEMPERATURE AND AIR FLOW DISTRIBUTION IN ENCLOSED ROOM

CFD modeling of dust dispersion through Najaf historic city centre

A Discussion of Low Reynolds Number Flow for the Two-Dimensional Benchmark Test Case

Simulation of Free Convection with Conjugate Heat Transfer

Natural Convection from a Long Horizontal Cylinder

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Analysis of the Cooling Design in Electrical Transformer

VERTICAL TURBULENT BUOYANT HELIUM JET CFD MODELING AND VALIDATION

EVALUATION OF FOUR TURBULENCE MODELS IN THE INTERACTION OF MULTI BURNERS SWIRLING FLOWS

Documentation of the Solutions to the SFPE Heat Transfer Verification Cases

Large-eddy simulations for wind turbine blade: rotational augmentation and dynamic stall

CHARACTERISTIC OF VORTEX IN A MIXING LAYER FORMED AT NOZZLE PITZDAILY USING OPENFOAM

SIMULATION OF MIXED CONVECTIVE HEAT TRANSFER USING LATTICE BOLTZMANN METHOD

Jets and Plumes. Agenda. Definition of jets, plumes, and others. Engineering applications of Jets/Plumes. Basic properties of Jets/Plumes

Validation 3. Laminar Flow Around a Circular Cylinder

Numerical simulations of the edge tone

Large eddy simulation of a forced round turbulent buoyant plume in neutral surroundings

Computer Evaluation of Results by Room Thermal Stability Testing

Flow analysis in centrifugal compressor vaneless diffusers

Model Studies on Slag-Metal Entrainment in Gas Stirred Ladles

Numerical Simulations of Turbulent Flow in Volcanic Eruption Clouds

A numerical study of heat transfer and fluid flow over an in-line tube bank

INVESTIGATION INTO RISE TIME OF BUOYANT FIRE PLUME FRONTS

Basic Features of the Fluid Dynamics Simulation Software FrontFlow/Blue

LARGE EDDY SIMULATION OF MASS TRANSFER ACROSS AN AIR-WATER INTERFACE AT HIGH SCHMIDT NUMBERS

DNS of Buoyancy Driven Flow Inside a Horizontal Coaxial Cylinder

Numerical Computation of Inception Point Location for Flat-sloped Stepped Spillway

Numerical prediction of indoor temperature stratification

A Discussion on The Effect of Mesh Resolution on Convective Boundary Layer Statistics and Structures Generated by Large-Eddy Simulation by Sullivan

Buoyancy Fluxes in a Stratified Fluid

OPTIMAL DESIGN OF CLUTCH PLATE BASED ON HEAT AND STRUCTURAL PARAMETERS USING CFD AND FEA

Numerical investigation of swirl flow inside a supersonic nozzle

Available online at ScienceDirect. Energy Procedia 78 (2015 )

DEVELOPMENT OF CFD MODEL FOR A SWIRL STABILIZED SPRAY COMBUSTOR

Simulation of unsteady muzzle flow of a small-caliber gun

Buoyancy-Driven Single-Sided Natural Ventilation in Buildings with Large Openings Yi Jiang a and Qingyan Chen b,*

arxiv: v1 [physics.flu-dyn] 11 Oct 2012

Application of COMSOL Multiphysics in Transport Phenomena Educational Processes

Towards a Numerical Benchmark for 3D Low Mach Number Mixed Flows in a Rectangular Channel Heated from Below

CFD MODELLING OF CONVECTIVE HEAT TRANSFER FROM A WINDOW WITH ADJACENT VENETIAN BLINDS

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate

Effect of Periodic Variation of Sol-air Temperature on the Performance of Integrated Solar Collector Storage System

Enhancement of Natural Convection Heat Transfer in a Square Enclosure with Localized Heating from Below

CFD Analysis of High Temperature and High Velocity System: Plasma Torch

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Module 6: Free Convections Lecture 26: Evaluation of Nusselt Number. The Lecture Contains: Heat transfer coefficient. Objectives_template

Introduction to CFD modelling of source terms and local-scale atmospheric dispersion (Part 1 of 2)

Computation of Unsteady Flows With Moving Grids

Towards LES models of jets and plumes

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Application of Computational Fluid Dynamics in Discontinuous Unsteady Flow with Large Amplitude Changes; the Shock Tube Problem

Transport by Gravity Currents in Building Fires RONALD G. REHM, K National Institute of Standards and Technology Gaithersburg, Maryland USA

Modeling night-time ventilation in Stanford s Y2E2 building

Experimental Verification of CFD Modeling of Turbulent Flow over Circular Cavities using FLUENT

University of Huddersfield Repository

VALIDATION OF REYNOLDS AVERAGED MODEL AND LARGE EDDY SIMULATION IN ACTUAL FLOOR HEATING ROOM. Hiroki Ono 1 and Koji Sakai 1

CFD AND EXPERIMENTAL ANALYSIS OF SINGLE PHASE BUOYANCY DRIVEN COUNTER-CURRENT FLOW IN A PIPE

Turbulence: Basic Physics and Engineering Modeling

If there is convective heat transfer from outer surface to fluid maintained at T W.

COMPUTATIONAL ANALYSIS OF LAMINAR FORCED CONVECTION IN RECTANGULAR ENCLOSURES OF DIFFERENT ASPECT RATIOS

Numerical Methods in Aerodynamics. Turbulence Modeling. Lecture 5: Turbulence modeling

CFD ANALYSIS OF IMPINGING AXISYMMETRIC TURBULENT FOUNTAINS

Circular Bearing Performance Parameters with Isothermal and Thermo-Hydrodynamic Approach Using Computational Fluid Dynamics

Process Chemistry Toolbox - Mixing

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

CFD analysis of the transient flow in a low-oil concentration hydrocyclone

THERMO-FLOW CHARACTERISTICS OF A PIN-FIN RADIAL HEAT SINKS ACCORDING TO THEIR FIN HEIGHT PROFILE

Transcription:

BSO12 First Building Simulation and Optimization Conference Loughborough, UK 10-11 September 2012 MODELLING BUOYANT THERMAL PLUMES IN NATURALLY VENTILATED BUILDINGS Faisal Durrani 1, Malcolm J Cook 2, and James J McGuirk 2 1 School of Civil and Building Engineering, Loughborough, LE11 3TU, UK 2 Department of Aeronautical and Automotive Engineering, Loughborough, LE11 3TU, UK ABSTRACT The aim of the work reported in this paper was to evaluate the performance of Large Eddy Simulation (LES) for modelling natural ventilation driven by twin plumes. The flow is characterised by an interface height which separates the warm buoyant air above from the cooler air below, and a merging height for coalescence of the two plumes. Comparison between the LES predictions and theory for the interface height and volume flow rate in the merged plumes is good, giving confidence that LES has potential for modelling this important class of flows. INTRODUCTION Natural ventilation can be used as part of a low energy strategy in reducing carbon emissions from buildings. Buoyancy-driven natural ventilation harnesses the buoyancy forces associated with temperature differences between the interior and exterior environments to drive a ventilation flow through a building. Amongst other parameters, the behaviour of thermal plumes and especially their interaction with each other (e.g. thermal plumes from a computer and its user) contributes largely to the final ventilation flow pattern. Heat sources within naturally ventilated buildings can be represented by sources that are isolated (Abdalla et al., 2007), a line heat source (Bastiaans et al., 2000) or by a uniformly distributed heat source over the entire floor area (Gladstone and Woods, 2001). Kaye and Linden (2004) using salt bath modelling and Durrani et al. (2011) using a Reynolds averaged Navier Stokes approach, studied the interaction of twin thermal plumes. Computational Fluid Dynamics (CFD) has been used widely to analyse natural ventilation. However, much of this work has considered steady-state solution techniques using RANS. Due to their inherent time averaging nature, RANS can significantly reduce the computational time but at the cost of losing instantaneous flow behaviour of any turbulence present in the flow. Hence, for those unsteady turbulent flow applications where the unsteady motions are of importance, Large Eddy Simulation (LES) can provide an alternative option in terms of high accuracy of simulation and acceptable computational time. With the recent developments in high performance computing, it has become possible to use transient methods such as LES. LES resolves the large eddies which carry most of the energy of the flow and play the main part in the resulting flow patterns. The effects of the smaller scales, which are mostly isotropic, are represented using an approximate mathematical model known as a subgrid scale model. This reduces the computational power required as compared to a Direct Numerical Simulation (DNS) approach in which the entire flow field is resolved. To the authors knowledge, very little work has been done to study buoyancy-driven thermal plume interactions using LES. Nam and Bill Jr (1993) simulated turbulent plumes using a modified k-ε turbulence model. Zhou et al. (2001) and Abdalla et al. (2007) used the LES approach to study thermal plumes, however the former focused on forced plumes while the latter on single isolated plumes. The aim of the work presented in this paper was to simulate twin thermal plumes in a naturally ventilated enclosure using LES. The results are intended to elucidate the interaction of the two plumes and to evaluate the performance of LES in modelling natural ventilation by comparing the results with existing analytical models. EXPERIMENTAL AND ANALYTICAL WORK Linden and Kaye (2006) suggest that for two unequal plumes the interface height is given by: ξ = ξ + ε (1) where ξ is the normalised interface height and ε is the small perturbation to the interface height given by: ε ξ v A H 2 C 3 2 5ξ 1 4 2 (2) 4 + 5ξ 1 For two unequal plumes with a buoyancy flux ratio ψ=0.5 the location of the virtual origin ξ v is given by Figure 9, Kaye and Linden (2004): Copyright IBPSA-England, 2012-117 -

ξ v = 0.11 x o α (3) where, x o is the heat source separation and α is the entrainment coefficient. Linden et al. (1990) derived the relationship between the normalised interface height ξ = h/h and the effective opening area, A* as: where, A H 2 = C3 2 ξ2 (4) 1 ξ C = 6α 9α 1 10 3 5 π 2 3 (5) Linden et al. (1990) used a value of 0.1 for the entrainment coefficient α. A is the effective opening area formulated by Hunt and Linden (2001) to represent openings of area a t and a b at the top and bottom of the space respectively: A = C D a t a b 1 2 C D 2 1 2 (6) a C 2 t + a 2 b e where C D and C e are the coefficients of expansion and discharge respectively. Linden et al. (1990) utilised top-hat profiles to represent their Gaussian counter-parts. Figure 1 illustrates a profile of the Gaussian and top-hat velocity profiles. The relationship between the tophat quantities and their Gaussian counterparts for a 3D point heat source are given by Cook (1998): Figure 1: Velocity profile of a plume representing the Gaussian and "top-hat" profiles (source: Cook, 1998) METHODOLOGY The Computational Domain and Boundary conditions The computational domain selected was a rectangular enclosure with a floor area of 1m x 1m and height 1m (Figure 2). Two heat sources, q 1 and q 2 were located close to the centre of the floor each with area 0.0009m 2 and separated by a distance of 0.1m (centre to centre). The strength of the heat sources was q 1 =20W and q 2 =10W. Long rectangular openings were specified along the top and bottom side edges of the enclosure each with an open area of 0.05m 2. The two openings at the bottom of the enclosure allow ambient air into the domain while the pair of openings at the top allows warm air out of the domain. V T = V G 2 (7) The volume flux is given by: b T = 2b G (8) Q = π b 2 T V T and the buoyancy is calculated using: (9) F = gβq ρc p (10) where, gis acceleration due to gravity, βis the exapnsion coefficient, q is the strength of the heat source, C p is the specific heat capacity and ρis the reference density. Figure 2: Computational domain in CFX - 118 -

At each opening, the following condition was imposed on pressure: p loss = 1 2 fρu n 2 (11) where, f is the loss coefficient and U n is the velocity component normal to the opening boundary. Initial conditions were such that the velocity components in the computational domain were set to zero and the temperature inside the room was the same as the ambient. This would ensure that the plumes would evolve in a stagnant flow and that stratified flow would develop quickly. The software package and LES method The software package used for the CFD simulations was CFX (2011). This software uses the finite volume method to discretise the incompressible continuity, momentum and energy equations. The solver is fully implicit thus making it stable with respect to time step size. The LES technique was applied to resolve the flow with the Smagorinsky model (Lilly, 1967) as the sub-grid scale model. The selection of the time step was based on the value of the Courant number (CFL). The CFL number reflects the distance that fluid will flow in one time step, as a proportion of a cell length and is given by: A statistically steady state was considered to be achieved when the following criteria had been met: ventilation flow rate was unchanging; velocity, temperature and pressure values for multiple monitor points inside the domain were stable These criteria were achieved after 90s of simulation time. In addition, a buffer of another 30s was modelled followed by a further 30s during which statistical analysis of the turbulence was carried out. Mean flow field Once the flow had reached steady state, the performance of LES was tested by comparing the interface height prediction with theory. With the formulation presented by Linden and Kaye (2006), for unequal plumes merging below the interface height, the normalized interface height should be ξ =0.677. Figure 3 illustrates the steady state mean temperature field. A vertical temperature profile plotted away from the plume centres helped determine the interface height (Figure 4). CFL = V t x (12) where V is the linear velocity, t is the time step size and x is filter width. The simulation ran with an adaptive time step initially with a value of 0.01s. The adaptive time step criterion was to maintain the CFL number in the range of 0.5-1.0. Once this criterion was achieved, the simulation was continued with a constant time step time step value i.e. 0.02s. Although the solver is implicit, for accuracy it is recommended that the CFL number is maintained in the range of 0.5-1.0. Coefficient loops solve the equations within each time step. In this work, the aim was to keep the inner coefficient loops within the 3 to 5 range. The convergence criteria for each time step were that the root mean square (RMS) residuals of velocity, temperature and pressure should be less than 1 10-6. RESULTS Determining convergence Steady state is reached when the flow in the computational domain has evolved and the transition and turbulent mixing is established. As per Linden et al. (1990) two homogeneous stratified layers are expected. Thus, temperature monitor plots were placed in the domain (but away from the two plumes) from the floor to the ceiling at 0.2m intervals to monitor the formation of such a regime. Figure 3: Mean temperature contour (x-y plane, z=0.5m) As can be seen from Figure 4 the air temperature remains constant below the height of 0.5m and above 0.8m with the interface located within this range. This is in contrast to the step change in temperature at the interface height shown by the analytical models. The transition layer between the lower ambient temperature fluid and the upper warm fluid extends over approximately 0.2m. Cook (1998) and Abdalla et al (2007) have also predicted this smeared interface using RANS and LES respectively. Abdalla et al (2007) suggest that this may be attributed to the turbulent diffusion of heat induced by the unsteady motion at the interface. - 119 -

Height above floor [m] 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 24.5 25 25.5 26 26.5 27 27.5 Air temperature [ o C] Temperature (LES) Interface height (theory) Figure 4: Mean temperature profile, (x,y,z)=(0.1,0-1,-0.1) Instantaneous field Figures 5 and 6 display the instantaneous temperature profiles passing through the centre of the domain. Figure 6 helps in visualising the 3D spread of the plume. The plots qualitatively suggest that the plumes are turbulent for the full distance from the heat source to the ceiling. This was indicated by the presence of no laminar flow patterns. To confirm the 3D turbulent motion of the plume, a graph is plotted of the instantaneous w-velocity component along the z-axis normalized by the maximum velocity along y-axis (v max ). Figure 7 illustrates this three dimensional motion and suggests that both the plumes contain significant three dimensional motion right from the heat sources. In addition, it is worth noticing that the plume of q 1 is more turbulent than the plume of q 2 as indicated by the larger variations in w/ v max value. Figure 6: Temperature contour over a y-z plane (x=0.5) Height above heat source (m) 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0-0.3-0.1 0.1 0.3 w/v max q1 q2 Figure 7: Instantaneous velocity along z-axis normalised by max value of velocity along y-axis Figure 5: Temperature contour over an x-y plane (z=0.5) Close to the heat sources the two plumes entrain surrounding air, they then grow in a radial direction until they merge with one another. This results in a merged plume of warm buoyant air that rises up towards the ceiling after which it spreads to the sidewalls and forms the upper layer of warm air. - 120 -

Figure 5 and 6 also confirm the presence of smaller coherent structures in the upper warm layer. It is worth noticing that the interface surface is not planar but rather undulating over a height of approximately 0.2m. This supports the findings in the mean flow field plot (figure 4) suggesting that the temperature across the interface is more diffuse than a step change. Small scale information that is obtained using LES such as the structure of small scales in the plumes is not available when using a RANS simulation. Figure 8 shows a RANS simulation for a similar case (Durrani et al., 2011). z below = 2.28 1 + ψ 1/3 1/3 Q 3/5 F 1 1/5 (14) and z above = 3.013(1 + ψ) 1/5 Q 3/5 F 1 1/5 + z v (15) Vertical velocity profiles with height 0 0.2 0.4 0.6 0.8 1 X [m] 0.35 m 0.4 m 0.45 m 0.5 m 0.55 m 0.6 m 0.65 m 0.7 m 0.75 m 0.8 m Figure 8: Temperature contour using RANS Plume merging height In order to determine the merge height (z m ) of the two plumes, the buoyancy or the velocity profiles can be plotted. These Gaussian profiles can be used to determine the merge height (Kaye and Linden, 2004). When the velocity profiles of the two plumes have merged it is reasonable to consider the plumes to have merged. Figure 9 illustrates the merging of the velocity profiles of the two plumes. It can be observed that above the height of 0.55m the profiles coalesce and hence the plumes are considered to have merged. It was also noted that the ratio of the peak velocities was ψ 1/3 whereas the ratio of the peak buoyancies was ψ 2/3 which was in accordance with Kaye and Linden (2004). Far-field flow In order to test the performance of LES, a series of flow rate predictions were made in the merged plume similar to Baines (1983) and Kaye and Linden (2004). The volume flux in a plume is given theoretically by (Kaye and Linden, 2004): Q = 5F 4α 1/3 6αz 5 5/3 (13) For a value of α = 0.09, Kaye and Linden (2004) report that the flow rates above and below the point of coalescence can be written as: z/xo Figure 9: Merging Gaussian profiles of the two plumes 9 8 7 6 5 4 3 2 1 0 0 0.2 0.4 0.6 0.8 1 Q 3/5 F 1-1/5 /x o Theory LES Figure 10: Variation of plume flow rates with height above the heat source (time averaged) The LES values were calculated using the top-hat velocity profiles in the plumes using the relationships provided by Cook (1998). The LES values clearly provide a good fit to the theoretical predictions (Figure 10). However, it can be seen that the LES simulations tend to over-predict the flow rates. This may be due to over-prediction of the plume entrainment. - 121 -

CONCLUSIONS LES has been used to investigate buoyancy-driven natural ventilation resulting from two coalescing plumes. The time averaged interface height that separates the upper warm layer from the lower ambient air is an important feature of such flows. Theory suggests that the interface height should be at a height of 0.677m whereas the LES results suggest a range (i.e. 0.5 to 0.8m) encompassing the theoretical value. This was predicted taking into account the virtual origin phenomena. The LES results of a range, rather than a single value for the interface height, suggests that the interface height remains unsteady throughout the flow process rather than being fixed as theory suggests. The instantaneous plots of temperature and velocity illustrate the turbulent nature of the plumes. The temperature plots were also helpful in identifying the presence of small coherent structures in the upper warm layer that are thought to contribute to the unsteadiness of the interface plane. Vertical velocity plots in the plumes at different heights helped determining the merging height of the two plumes. The LES solution of the plume volume flow rate, Q, in the merged plume agreed favourably with the theoretical predictions. The slight over-predictions at some heights is thought to be caused by small variations in the plume entrainment. It is concluded that LES provides a greater insight than RANS into the turbulent processes that underpin buoyancy-driven natural ventilation and that the results obtained agree well with theoretical models of the same flow. It is possible that LES could provide valuable insight into the transient evolution and pseudo steady-state behaviour of such flows, which is important in predicting the prevailing air flow directions at inlets and outlets, ventilation rates and temperature distribution in naturally ventilated spaces. The authors are building on the validation work reported here to look at the potential of using LES for larger, more realistic geometries. REFERENCES Abdalla, I. E., Cook, M. J., Rees, S. J. and Yang, Z. (2007). "Large-eddy simulation of buoyancydriven natural ventilation in an enclosure with a point heat source." International Journal of Computational Fluid Dynamics 21(5-6): 231-245. ANSYS_CFX_version_12.1 (2011). www.ansys.com (accessed 08 Novemeber 2011). Baines, W. D. (1983). "A technique for the measurement of volume flux in a plume." Journal of Fluid Mechanics(132): 247-256. Bastiaans, R. J. M., Rindt, C. C. M., Nieuwstadt, F. T. M. and van Steenhoven, A. A. (2000). "Direct and large-eddy simulation of the transition of two- and three-dimensional plane plumes in a confined enclosure." International Journal of Heat and Mass Transfer 43(13): 2375-2393. Cook, M. J. (1998). "An Evaluation of Computational Fluid Dynamics for Modelling Buoyancy-Driven Displacement Ventilation." PhD thesis, (De Montfort University, Leicester.). Durrani, F., Cook, M. J. and McGuirk, J. J. (2011). CFD modelling of plume interaction in natural ventilation. Building Simulation 2011. Sydney. Gladstone, C. and Woods, A. W. (2001). "On buoyancy-driven natural ventilation of a room with a heated floor." Journal of Fluid Mechanics 441:.293-314. Hunt, G. R. and Linden, P. F. (2001). "Steady-state flows in an enclosure ventilated by buoyancy forces assisted by wind." Journal of Fluid Mechanics(426): 355-386. Kaye, N. B. and Linden, P. F. (2004). "Coalescing axisymmetric turbulent plumes." Journal of Fluid Mechanics 502: 41-63. Lilly, D. K. (1967). "The representation of smallscale turbulence in numerical simulation experiments." Proc. of the IBM scientific Computer Symposium on Environmental Sciences. (IBM Form No. 320-1951): 195-210. Linden, P. F. and Kaye, N. B. (2006). "Interacting turbulent plumes in a naturally ventilated enclosure." International journal of ventilation 4(4): 301-310. Linden, P. F., Lane-Serff, G. F. and Smeed, D. A. (1990). "Emptying filling boxes: the fluid mechanics of natural ventilation." Journal of Fluid Mechanics 212: 309-335. Nam, S. and Bill Jr, R. G. (1993). "Numerical simulation of thermal plumes." Fire Safety Journal 21(3): 231-256. Zhou, X., Luo, K. H. and Williams, J. J. R. (2001). "Large-eddy simulation of a turbulent forced plume." European Journal of Mechanics - B/Fluids 20(2): 233-254. NOMENCLATURE a b area of the lower opening (m 2 ) a t area of the upper opening (m 2 ) b G Gaussian plume width (m) b T top-hat plume width (m) C D coefficient of discharge (-) Ce coefficient of expansion (-) C p specific heat capacity (J/kg K) CFL Courant number (-) F Buoyancy flux (kg/m 2 s 2 ) - 122 -

g acceleration due to gravity (m/s 2 ) H h total height of computational domain (m) mean interface height (m) f loss coefficient (-) Q volume flux (m 3 /s 1 m 2 ) q heat source strength (W) v G v T U n x 0 z m Gaussian velocity (m/s) top-hat value for velocity (m/s) normal velocity (m/s) source separation (m) plume merge height (m) x,y,z Cartesian coordinates (m) α plume entrainment coefficient (-) β coefficient of thermal expansion (-) ρ density (kg/m3) ε perturbation in interface height (-) ξ normalised interface height (h/h) (-) ξ v V location of virtual origin (m) linear velocity (m/s) ψ buoyancy flux ratio (-) P loss t x pressure loss across the opening (Pa) time step size (s) filter width (m) - 123 -