SUPPORTING INFORMATION

Similar documents
Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

GAMINGRE 8/1/ of 7

Supporting Information

DISCOVER-AQ Houston as a case study for understanding spatial and temporal trends in urban particulate matter

Measurements of Parameters Controlling the Emissions of Organophosphate Flame Retardants in Indoor Environments

Author. Abstract. Introduction

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Key Words: Organophosphate esters; Gel permeation chromatograph; Solid phase extraction; Human serum; Gas chromatography-mass spectrometer

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD

Distinct photoproducts of hydroxylated polybromodiphenyl ethers from different photodegradation pathways: A case of 2'-HO-BDE-68

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Supplementary Materials: Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry

Supporting Information

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Supporting Information. Organophosphate Esters in Sediment of the Great Lakes

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Application Note. Abstract. Authors. Introduction. Food Safety

637. Thiamethoxam. HPLC method

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

METHOD 8430 ANALYSIS OF BIS(2-CHLOROETHYL) ETHER AND HYDROLYSIS PRODUCTS BY DIRECT AQUEOUS INJECTION GC/FT-IR

Sulfotepp impurities in Chlorpyrifos EC formulations

Journal of Chemical and Pharmaceutical Research

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

NCFS Sample Preparation and Instrumental Parameters

GC Analysis of Polybrominated Flame Retardants Application

Analysis of Total PCBs and PCB Congeners and Trans-nonachlor in Fish by Gas Chromatography/ Negative Chemical Ionization Single Ion Mass Spectrometry

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

Ultra-Inert chemistry for Trace Level Analysis

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Determination of Cannabinoids (THC) in Biological Samples

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

METHOD 8111 HALOETHERS BY GAS CHROMATOGRAPHY

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

BFRs, CFRs, PFRs: Where are we with the Toxic Alphabet Soup?

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Supporting Information for Temporal Trends of Halogenated Flame Retardants in the Atmosphere of the Canadian Great Lakes Basin ( )

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Shock synthesis of amino acids from impacting cometary and icy planet surface analogues

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

METHOD 3600B CLEANUP

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Benzoylecgonine in Urine by SAMHSA GC/MS

5Cl-AKB48 and 5Br-AKB48

Sensitive Detection of Pyrethroids in Surface Water and Sediment

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

Supporting Information. Organophosphate Esters in Canadian Arctic Air: Occurrence, Levels and Trends

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

Technical note on seasonal adjustment for M0

Method - Determination of aromatic amines in mainstream cigarette smoke

JWH-018 and JWH-022 as Combustion Products of AM2201

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

Limit-test of NDMA and NDEA in Sartans. by GC-MS (Liquid-direct-injection)

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

ORGANOPHOSPHORUS PESTICIDES 5600

Analysis of BTEX in Natural Water with SPME

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Appendix II- Bioanalytical Method Development and Validation

Opiates in Urine by SAMHSA GC/MS

GC-CI-MS analysis of TMS derivatives

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

U.S. EPA Method 8270 for multicomponent analyte determination

A New Web-Based Application for Modeling Gas Chromatographic Separations

1-(1,3-benzodioxol-5-yl)-2-(ethylamino)hexan-1-one

Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge Application

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Transcription:

SUPPORTING INFORMATION High Levels of Organophosphorus Flame Retardants in the Great Lakes Atmosphere Amina Salamova, Yuning Ma, Marta Venier, and Ronald A. Hites* School of Public and Environmental Affairs, Indiana University Bloomington, Indiana 70 Experimental Details Instrumental Analyses. The samples were analyzed for the following compounds: Chlorinated phosphate esters: tris(-chloroethyl)phosphate tris(-chloro--propyl)-phosphate tris(,-dichloro--propyl)phosphate Alkyl phosphate esters: tri-n-butyl phosphate tri(butoxyethyl)phosphate tris(-ethylhexyl)phosphate Aryl phosphate esters: triphenyl phosphate tri-o-tolyl-phosphate tri-p-tolyl-phosphate tris(,-dimethylphenyl)-phosphate tris(-isopropylphenyl)phosphate tris(-butylphenyl) phosphate (TCEP) (TCPP) (TDCPP) (TnBP) (TBEP) (TEHP) (TPP) (TOTP) (TPTP) (TDMPP) (TIPPP) (TBPP) Analyses were performed on an Agilent 790 series gas chromatograph coupled to an Agilent 97 mass spectrometer operating in the electron impact mode. Chromatographic separations were achieved using a DB-MS Ultra Inert capillary column (0 m 0 µm film thickness, Agilent Technologies, Santa Clara, CA). Injections ( µl) were made in the pulsed splitless mode, and the injection port was held at 0 ºC. The GC oven temperature was programmed as follows: 70 ºC for min, 0 ºC/min to 70 ºC, held for min, 0 ºC/min to 0 ºC, held for min, ºC/min to 0 ºC, and then 0 ºC/min to 00 ºC, held for min. The total run time was minutes. The helium carrier gas (99.999%; Liquid Carbonic, Chicago) was used at a constant flow rate of. ml/min. The temperature of the GC-MS transfer line was maintained at 0 ºC. The electron energy was set at 70 ev, and the ion source temperature was set at 0 C. Selected ion monitoring of the following ions was used to detect and quantitate these compounds:

Compound m/z TnBP 99 TEHP 99 TCEP 9 TCPP TDCPP 9 TPP TBEP TOTP TPTP TIPPP TDMPP 0 TBPP 79 Quality Control and Quality Assurance. Details on IADN quality control and quality assurance procedures are described in the IADN Quality Assurance Program Plan (U.S. EPA 00). Briefly, four quality control criteria were used to ensure the correct identification and quantitation of the target compounds: (a) The gas chromatographic retention times matched those of the standard compounds within ± 0. minutes. (b) The signal-to-noise ratio was greater than :. (c) The isotopic ratios for selected ion pairs were within ± % of the theoretical values. (d) The recoveries of recovery standards [d -tris(-chloroethyl)phosphate (TCEP) and C triphenyl phosphate] were between 0% and 0%. The average surrogate recoveries were in the range of 70-00%. Either a laboratory blank (a quartz fiber filter or a XAD- cartridge extracted in the laboratory the same way as the samples) or an OP spike recovery sample was run with every batch of -0 samples. In total, laboratory blanks were extracted, and the average total ΣOP mass in these blanks were. ±. ng. Only TnBP and TPP were detected in the laboratory blanks with the average levels of.7 ±.0 ng and. ± 0. ng, respectively. These masses in the blanks correspond to < 0% of the mass collected in any of the rural or remote air samples and < % of the mass collected in either of the urban samples. The average recoveries for the spiked samples were ~7%. Field blanks were collected at every site seasonally and were used to assess the extent of background contamination present in the field. Field blanks were collected using the same type of quartz fiber filters and XAD- resin cartridges. The blanks were installed and kept in a collocated sampler for the same period of time as regular samples without turning on the sampler motor. ΣOPs concentrations in the field blanks comprised ~%, %, %, %, and 7% of these concentrations in Chicago, Cleveland, Eagle Harbor, Sleeping Bear Dunes, and Sturgeon Point samples, respectively. On average, ΣOPs concentrations in the field blanks comprised ± % of these concentrations in all of the samples. TnBP, TDCPP, TCEP, and TPP were the most abundant OPs in these blanks and comprised ± 7%, ± %, ± 7 %, and 9.7 ±.% of average sample levels, respectively. TCPP, TBEP, TEHP, and TBPP were detected in blanks at < % of average sample levels. The rest of the OPs were not detected in the field blanks. Concentrations below the annual field blank site-by-site averages were treated as non-detects.

Materials. TnBP was purchased from Acros Organics, distributed by Fisher Scientific, Pittsburgh, PA. TCEP, TCPP, and were purchased from AccuStandard, New Haven, CT. TPP, TOTP, TPTP, TDMPP, and TIPPP were purchased from Wellington Laboratories, Guelph, ON. TBEP and TEHP were from MP Biomedicals, Santa Ana, CA. TBPP was from Sigma-Aldrich, St. Louis, MO. All solvents used for the extraction and cleanup procedures were residueanalysis grade. Glassware was baked at 00 0 C for at least hours prior to use. FIGURE S. Locations of the United States Integrated Atmospheric Deposition Network (IADN) sampling sites.

Figure S. Structures of the compounds discussed in the text, their abbreviations, and their Chemical Abstracts Registry Numbers. Section A represents alkyl phosphate esters, section B represents chloroalkyl phosphate esters, and section C represents aromatic phosphate esters.

0 Chicago 0 Cleveland ln(σop) conc. Sturgeon Point Sleeping Bear Eagle Harbor Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan FIGURE S. Seasonal variations in ΣOP concentrations (plotted as the natural logarithms of their concentrations in pg/m ) at the five IADN sites.

ln (ΣCl-OP) conc. 9 7 0 - A. Slope =.0 ± 0. P = 0.00 ln (ΣOP) conc. 9 7 0 - B. Slope = 0. ± 0.0 P = 0.00 - - - - 0 ln (Penta-BDE) conc. - - - - 0 ln (Penta-BDE) conc. ln (TPP) conc. C. Slope = 0.9 ± 0.7 P = 0.0 ln (TPP) conc. D. Slope = 0.7 ± 0.0 P = 0.007 - - - - 0 ln (Penta-BDE) conc. - - - - 0 ln (TBB + TBPH) conc. Chicago Cleveland Sturgeon Point Sleeping Bear Eagle Harbor FIGURE S. Pairwise correlations of the natural logarithms of the seasonally averaged concentrations (in pg/m ) for: (A) Penta-BDE and ΣCl-OPs; (B) Penta-BDE and ΣOPs; (C) Penta-BDE and TPP; and (D) TBB+TBPH and TPP at the five IADN sites. The regression lines (in black), the probabilities of the regressions being not significant (P), and the slopes are given in each plot.