Benzene Contamination in BabyFood and Beverages by New Generation of Static Headspace Autosampler coupled to Fast GC-TOFMS

Similar documents
Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

HIGH SPEED GC-TOFMS FOR ESSENTIAL OILS PROFILING IN ROUTINE QUALITY ASSESSMENT

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Application Note. Abstract. Authors. Introduction

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Certified Reference Material - Certificate of Analysis

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Application. Gas Chromatography February Introduction

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Application. Gas Chromatography March 1998

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Study of Residual Solvents in Various Matrices by Static Headspace

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline (2-AP), Using TurboMatrix Headspace Trap Coupled with GC/NPD and GC/MS

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Maximizing Sample Throughput In Purge And Trap Analysis

UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

TIME OF FLIGHT GC/MSTOF

Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

DETERMINATION OF PHTHALATES FROM BOTTLED WATER BY GC-MS

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

TOF. Plus. Time of Flight GC/MS. The New Concept of High Speed TOF-MS. Extremely Compact Design. High Sample Throughput

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Highly Sensitive and Rugged GC/MS/MS Tool

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Multi-residue analysis of pesticides by GC-HRMS

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Application Note 032

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Certified Reference Material - Certificate of Analysis

Volatile Organic Compounds in Every Day Food

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

ENVIRONMENTAL analysis

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Blood Alcohol Determination using Static Headspace Analysis with Optimized Sample Throughput

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1

Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Author. Abstract. Introduction

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Solid Phase Micro Extraction of Flavor Compounds in Beer

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Transcription:

Benzene Contamination in BabyFood and Beverages by New Generation of Static Headspace Autosampler coupled to Fast GC-TOFMS Authors: Daniela Cavagnino DANI Instruments SpA viale Brianza, 87 Cologno Monzese Milano Italy Key Points: Valve & Loop SHS Approach No Sample Toluene as Internal Standard Introduction It s demonstrated that the combination of benzoate salts with ascorbic acid produces low levels (ng/g) of benzene. Benzoates are widely used as food preservatives and especially beverages, like fruit-flavored soft drinks, suffer potentially for benzene formation. Benzene contamination was recently found also in benzoate free foods, especially in carrots products for infants. The chemical process that leads to benzene formation is still unclear: heat-treatments seem to have a key role, promoting the benzene release from suspected precursors (beta-carotene and terpenes). Due to benzene high carcinogenic activity, its presence in food and beverages is of great concern. In particular, contamination in baby food is even more critical, since infants are more exposed to toxicity than adults. The new generation of Static Headspace Autosampler coupled to Fast GC-TOFMS system, is proposed for benzene contamination assessment in different food and beverages products. Besides a quick sample preparation offered by the static headspace technique, lower detection limit and outstanding repeatability are achieved. Fast GC allows to complete the chromatographic run in 1 minutes, maintaining the required separation power and improving the sample throughput. The use of Fast GC enhances the potential of High Speed TOF-MS technology, in which the acquisition rate can be increased without sacrificing sensitivity or losing spectral information. High quality mass spectra and effective deconvolution algorithm guarantee a reliable identification, even in case of co-elution and matrix interferences. The obtained results confirm that the described system offers the specificity and sensitivity required to detect benzene in different food and beverages samples.

Method The official limits for benzene in food and beverages are based on drinking water regulation. The Food and Drugs Administration (FDA) refers to the US EPA MCL of 5 ppb for drinking water while the European Union has more stringent regulation down to 1 ppb. The Static Headspace sampling technique coupled to GC- TOFMS has been used to verify the compliance to the limit of detection. Two important parameters affects the sensitivity of a headspace analysis: the partition coefficient and the phase ratio, as shown in Figure 1. The DANI MasterSHS based on the Valve&Loop technology (Figure 2) assured very high repeatability of the injection thanks to the electronic control during vial pressurization and loop filling steps. The operative conditions are summarized in Table 1. SAMPLE VIAL Partition Coefficient Phase Ratio K = Cs / Cg β = Vg / Vs Analyte Concentration in the headspace Cg = C / (K+β) Cs = Concentration in the liquid sample after equilibration Cg = Concentration in the gas phase after equilibration Vs = Volume of the liquid phase (sample) Vg = Volume of the gas phase (headspace) Figure 1. Parameters affecting the headspace analysis VENT CARRIER AUXILIARY GAS MANIFOLD LOOP TO GC ü Highest Inertness ü Highest repeatability OVEN SAMPLE VIAL Figure 2. Valve&Loop technology of the DANI Master SHS

Sample preparation - Soft Drinks A carbonated Cola drink and an Orange Vitamin Juice have been purchased from local market and kept at low temperature (5 C).1mL of sample was transferred in 2mL vial with the addition of a dilute solution of KOH (1% m/m) to adjust the ph to 1 [1]. Toluene was added as internal standard to a final concentration of 1 ppb and an external calibration curve of benzene normalized against the IS has been used for quantitation. A second batch of standards have been prepared by using d6-benzene as IS at 1 ppb instead of Toluene for comparison purposes Vitamin Juice Carbonated Cola Sample preparation - Baby Food Three different types of homogenized baby food with different carrots content have been evaluated Baby Jar (A) Baby Jar (B) Master GC Column SolGel Wax 1m,.1mm id,.1um th Ovent Temp 4 C (1 min), 25 C, 23 C (1 min) SSL Temp 25 C Carrier Gas He @.5mL/min, 23 C (1min) Split Ratio 15:1 Baby Jar (C) Carrots 35% Carrots 78% Carrots 55% 1g of sample have been weighted in a 2mL vial with the addition of diluted KOH solution (1% m/m) till ph=1 The same calibration approach has been used by using benzene-d6 or Toluene as IS at a final concentration of 1 ppb Master SHS Incubation Temp 5 C Incubation Time 3 min Shaking Medium Vial Pressure 1 bar Loop Volume 1 ml Manifold Temp 6 C Transfer Line Temp 7 C Master TOFMS Ionization Source 7eV Source Temp 2 C Transfer Line Temp 25 C Mass Range 4-55 amu Acquisition Freq. 1 spectra/sec Table 1. Operative conditions for the system MasterSHS-GC-TOFMS (A) (B) (C) Results The carcinogenic property of Benzene are well known and it is also well known the major source of exposure comes from the environment as active and passive smoke and automobile exhaust. However, high levels of benzene metabolites have been reported in children and non-smoking people without occupational exposure, indicating a possible additional source of benzene like food, which contributes to the total intake. Therefore over the last few years, some laboratories started to publish results showing some cases of soft drinks containing few ppb levels. There are evidence that benzene can be generated by the interaction of benzoate salts (typically added as a preservative) and ascorbic acid, reaction favored by high T, UV light and acidic conditions. However, from a survey done by the Food Standard Agency in UK on 15 drinks, benzene was sporadically present and only in 4 cases above the official limit of 1 ppb set by the World Health Organization for benzene in drinking water. Also in our study no benzene has been detected above the detection limit for both the soft drink samples, as shown in Figure 3, along with the repeatability and the linearity data. Further testing are going on by keeping the sample at higher temperature, simulating a bad storage condition.

7 replicates of spiked Cola drink RSD% = 2.6 Benzene 1ppb Extracted ion m/z = 78 3 25 2 15 1 5 Linearity with Toluene IS (m/z = 91) y =,2533x R 2 =,9993 Standard Benzene.1 ppb Sample Cola 6 5 4 3 2 1 Linearity with d6- benzene IS (m/z = 84) y =,5245x R² =,9996 Sample Vitamin Juice 5 points calibration in the range.1-1 ug/kg The standards have been prepared in a benzene-free cola matrix The extrapolated limit of detection (SNR=3) for benzene is.4 ng/g evaluated in the spiked Cola sample Figure 3. Soft drinks samples analysis, Precision, Linearity, and LOD data The baby food samples resulted all positive with a concentration of benzene in the range.9-2.4 ng/g. The heat-induced formation of benzene is still not clearly elucidated, but likely responsible of the higher benzene levels in carrots based baby food. Possible precursors include carotenoids, terpens and aminoacids.industrial food processing is more responsible since the use of higher temperatures for longer time and higher pressures compared to home-cooking preparation. Besides, baby food are submitted to even stronger sterilization conditions and this could explain their relatively high concentration of benzene compared to carrots containing processed food for adults. Quantification Benzene residue (ng/g) (IS Toluene) Quantified Benzene residue (ng/g) (IS d6-benzene) Baby Jar (A) Carrots 35% Baby Jar (B) Carrots 78% Baby Jar (C) Carrots 55% <.1 1.1 2.4 <.1 1. 2.1 Linearity with Toluene IS (m/z = 91) 6 Linearity with d6- benzene IS (m/z = 84) 2 Extracted Ion m/z=78 5 4 3 y =,577x 2 R 2 =,9996 1 16 12 8 4 y = 1,76x R 2 =,9993 5 points calibration have been prepared in distilled water with the same addition of diluted KOH solution The possible advantageous salting out effect by addition of Na 2 SO 4 has been also evaluated by adding 1g of salt, without significant improvement in benzene recovery The repeatability was confirmed with RSD < 3% Figure 4. Baby food samples analysis Standard in water.1 ppb Sample Jarred Baby Food (A) NIST matching >9

Conclusion Heat-treated processed food containing carrots analyzed in our laboratory shows benzene content above the accepted limit in drinking water, indicating a possible additional human exposure. Benzene in food and specifically in baby food has to be further investigated worldwide by the official food control organizations as potential significant intake in addition to the major environmental exposure, contributing to a possible cumulative effect. Some levels of benzene in beverages containing benzoate salts and ascorbic acid can be promoted by bad storage at elevated temperature and UV light exposure. However, for samples which have been submitted to proper storage conditions, no significant risk of benzene formation is evident. SHS-GC-TOFMS methodology has been demonstrated as a very suitable method to detect low levels of benzene in different food matrices (<.1 ug/kg). Typically Benzene-d6 is used as IS for this application. Toluene can be used alternatively considering the similar water/air partition coefficient of benzene and toluene (respectively 2.9 and 2.82 at 4 C). Finally, full spectra information from the TOF- MS assures high specificity for an unequivocal identification of the target analyte. Reference [1] Lachenmeier et al., Food Addit Contam, 28, 25, 1216-1224 [2] Lachenmeier et al, The Open Toxicology Journal, 21, 4, 39-42 [3] Food Survey March 26, www.food.gov.uk

www.dani-instruments.com The contents of this publication are for reference and illustrative purposes only. Information, descriptions and specification are subject to change without notice. DANI Instruments assumes no responsibility and will not be liable for any errors or omissions contained herein or for incidental, consequential damages or losses in connection with the furnishing, performance, or use of this material. AN_155