Extrel Application Note

Similar documents
Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Catalysis CAPABILITIES

Extrel is widely respected for the quality of mass spectrometer systems that are

RGA modelling and simulation to include pressure dependence in the ion source

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

vacuum analysis plasma diagnostics surface science gas analysis

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Mass Spectrometry in MCAL

Practical Quadrupole Theory: Peak Shapes at Various Ion Energies

Introduction to the Q Trap LC/MS/MS System

Hiden HPR60 Molecular Beam Mass Spectrometer System

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Chemistry 311: Topic 3 - Mass Spectrometry

Interface (backside) & Extraction Lens

LECTURE 5 SUMMARY OF KEY IDEAS

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Hiden EQP Applications

Lecture 6 Plasmas. Chapters 10 &16 Wolf and Tauber. ECE611 / CHE611 Electronic Materials Processing Fall John Labram 1/68

high temp ( K) Chapter 20: Atomic Spectroscopy

Lecture 22 Ion Beam Techniques

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Ionization Techniques Part IV

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Lecture 3 Vacuum Science and Technology

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

CHAPTER 6: Etching. Chapter 6 1

Quadrupole Miniaturization: Revisited

Secondary ion mass spectrometry (SIMS)

Suzanne Bell Second Edition

Harris: Quantitative Chemical Analysis, Eight Edition

Control of gas discharge plasma properties utilizing nonlocal electron energy distribution functions DOE-OFS Plasma Science Center

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Determination of Minimum Detectable Partial Pressure (MDPP) of QMS and its Uncertainty

MS/MS .LQGVRI0606([SHULPHQWV

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

ICPMS Doherty Lecture 1

TANDEM MASS SPECTROSCOPY

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Lecture 15: Introduction to mass spectrometry-i

High power impulse plasmas for thin film deposition

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Combinatorial RF Magnetron Sputtering for Rapid Materials Discovery: Methodology and Applications

Mass Spectrometer A Comparison of Positive and Negative Ion RGA Methods

Study of DC Cylindrical Magnetron by Langmuir Probe

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Introduction to Plasma

Section 5: Thin Film Deposition part 1 : sputtering and evaporation. Jaeger Chapter 6. EE143 Ali Javey

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

Langmuir Probes as a Diagnostic to Study Plasma Parameter Dependancies, and Ion Acoustic Wave Propogation

a. An emission line as close as possible to the analyte resonance line

Effect of Noble Gas. Plasma Processing Laboratory University of Houston. Acknowledgements: DoE Plasma Science Center and NSF

MS Goals and Applications. MS Goals and Applications

Secondary Ion Mass Spectroscopy (SIMS)

1. The range of frequencies that a measurement is sensitive to is called the frequency

Propose a structure for an alcohol, C4H10O, that has the following

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

10/8/2013. Alternatives to Mass Spectrometry and Some Real-time Monitoring Measurements. Project Driven Tasks -- Process Gas Measurements

Review of investigation of influence of operational parameters on metrological characteristics of QMS within EMRP IND12 project

Introduction to GC/MS

Etching Issues - Anisotropy. Dry Etching. Dry Etching Overview. Etching Issues - Selectivity

FIB - SIMS. Focussed Ion Beam Secondary Ion Mass Spectrometry.

Secondary Ion Mass Spectrometry (SIMS)

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

TPRS with MATLAB and quantitative mass spec review. Cassandra Siler

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Secondaryionmassspectrometry

Effect of small amounts of hydrogen added to argon glow discharges: Hybrid Monte Carlo fluid model

Two-electron systems

Defining quality standards for the analysis of solid samples

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Enhanced High Aspect Ratio Etch Performance With ANAB Technology. Keywords: High Aspect Ratio, Etch, Neutral Particles, Neutral Beam I.

arxiv: v1 [physics.plasm-ph] 10 Nov 2014

Chapter 13: Partial Pressure Analysis

Types of Analyzers: Quadrupole: mass filter -part1

MS Goals and Applications. MS Goals and Applications

~1 V ~20-40 V. Electron collector PLASMA. Ion extraction optics. Ionization zone. Mass Resolving section Ion detector. e - ~20 V Filament Heater

Mass Spectrometry. Electron Ionization and Chemical Ionization

Theory of Gas Discharge

Ion Trajectories in the Injection Quadrupole for SIFT-MS

TMT4320 Nanomaterials November 10 th, Thin films by physical/chemical methods (From chapter 24 and 25)

MAX300-BIO Bioreactor and Fermentation Gas Analyzer. Providing Solutions for Gas Analysis

M M e M M H M M H. Ion Sources

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Reactive Etching and Surface Damage

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Week 5: Fourier Tranform-based Mass Analyzers: FT-ICR and Orbitrap

RECOMMENDATIONS FOR NOMENCLATURE OF MASS SPECTROMETRY

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

Transcription:

Extrel Application Note Real-Time Plasma Monitoring and Detection of Trace H 2 O and HF Species in an Argon Based Plasma Jian Wei, 575 Epsilon Drive, Pittsburgh, PA 15238. (Presented at the 191st Electrochemical Society Meeting, May 4-9, 1997) A plasma monitoring system was constructed by combining a molecular beam sampling system with a quadrupole deflector energy filter coupled to a quadrupole mass filter. The plasma is sampled via rapid pressure reduction into an intermediate chamber as a molecular beam, eliminating secondary reactions due to collisions with neutrals and other ions after sampling. Ionic species of differing energies are separated through the use of a quadrupole deflector energy filter, allowing differentiation of the source of the ionic signal (plasma versus sheath). To detect trace H 2 O and HF in Ar based plasmas, the quadrupole mass spectrometer needs both high mass resolution and high abundance sensitivity. High mass resolution and high abundance sensitivity can be achieved through the operation of a quadrupole in the second Mathieu stability region. Using this high resolution mode, a quadrupole can be used to separate H 2 O + from 36 Ar ++ and HF + from and 40 Ar ++. I. INTRODUCTION The chemical composition of a plasma can be complicated. The challenge in the analysis of the plasma chemistry is to measure the composition as it is in the plasma. The implementation of the molecular beam sampling scheme with a sampling skimmer and two stage differential pumping, enables the sampling of the ions, radicals and neutrals before they collide with one another or with the analyzer chamber wall. By using two distinct pumping stages, the sampling orifice can be made larger, improving sensitivity, while pumping the scattered background gases more efficiently than possible in a one stage system. The analysis of the plasma ions may also require the sampling of ions in a certain energy range or the mapping of the ion energy distribution. For example, at a suitably high pressure, all of the ions originating directly in the plasma are at the same potential, while there is a potential gradient in the sheath that surrounds the plasma. The incorporation of an energy filter into the mass spectrometer system allows simple characterization of the energy distribution of the ion samples by sampling the plasma at high energy resolution, and varying the center-point energy of the energy filter, resulting in an energy scan. One can characterize ions with a specific energy by simply selecting the appropriate center-point energy. Detection and monitoring of contamination species in a plasma source is a critical issue in semiconductor manufacturing processes. For example, when Ar plasma is used for the sputtering of metal films, trace water in the plasma source can cause a detrimental effect to the films. Monitoring of the plasma source with a high resolution quadrupole mass spectrometer can allow the detection and quantitation of these contaminants in real time. The Ar plasma generates both single- and doublecharged ions. With a normal residual gas analyzer (RGA), the Ar ++ ions will cause ion interference at 18 and 20 m/z and prevent the detection of trace H 2 O and HF in the Ar plasma. The difference in mass-to-charge ratio between H 2 O + and 36 Ar ++ is 0.0268 amu, and that between HF + and 40 Ar ++ is 0.0250 amu. The detection of trace H 2 O and HF in the Ar based plasma thus requires both high mass resolution and high abundance sensitivity (contribution of the intensity from a given mass at the baseline of the neighboring masses) from the quadrupole mass spectrometer. The operation of the quadrupole mass filter in the second Mathieu stability region has demonstrated a resolving power (full width at half maximum) of better than 0.001 amu at m/z 4 (1) and about 0.005 amu at m/z 28 (2). Second stability operation has also shown an enhancement of more than two orders of magnitude in abundance sensitivity over the operation in the first stability region (1). The addition of the second stability operation to the quadrupole mass spectrometer will greatly enhance its capability in product quality control and monitoring in plasma applications. 1 of 5

II. EXPERIMENTAL The plasma monitoring measurements were performed on an Extrel two stage molecular beam sampling system, shown in Figure 1. A molecular beam sampling approach with two stage differential pumping is used here to avoid the collision of the ions, radicals and neutrals with one another and with the chamber walls. The floating skimmer, which separates the plasma source and the first stage chamber, provides the mechanism to sample the positive or the negative ions. The beam chopper can be utilized to perform modulated beam measurements to differentiate beam components from residual gas background (scattered species) or, via a suitable bias voltage, to exclude the ions from the plasma source when the neutrals and radicals are being analyzed. Radicals and neutrals are then ionized by the electron impact (EI) ionizer situated in the second stage chamber. The quadrupole deflector energy filter behind the EI ionizer is designed to select ions in a particular kinetic energy range or to provide an energy scan for the ions. The off-axis arrangement for the quadrupole mass filter and ion detector also reduces the background noise from photons, electrons and other high kinetic energy species originating in the plasma. sampling system chamber. The schematic for the DC glow discharge is shown in Figure 2. Figure 2. Schematic for DC glow discharge chamber. The mass filter used in the plasma monitoring study was an Extrel Merlin MEXM-500 system consisting of a 19 mm diameter quadrupole operating at 1.2 MHz. Merlin control electronics were used for instrument control and data acquisition. Three different gas mixtures were analyzed in the DC plasma. Two mixtures were maintained at 1.0 Torr: 99.99% pure Argon; and a mixture of SF 6 (1%), H 2 (3.67%), Ar (1.0%) and N 2 (balance). Pure C 2 H 6 was used for the appearance potential measurements, with the gas pressure maintained at 0.11 Torr. The DC glow discharge voltage applied to the cathode was about -2kV, except for the C 2 H 6 plasma where the voltage was -3.8 kv. The DC glow discharge current was maintained at a fix current ranging from 4 to 9 ma. When the ions from the plasma were analyzed, the EI filament was turned off. For the high resolution second stability work, an Extrel Merlin MEXM-500B mass spectrometer system (9.5 mm quadrupole operated at 2.1 MHz) was used. The experiment was carried out in a vacuum chamber equipped with two variable leak valves, with ions generated from the resulting residual gasses using an axial molecular beam ionizer with a heated cathode tungsten filament. The 36 Ar isotope (abundance: 0.337%) from a leak of Ar gas into the chamber was used to generate the 36 Ar ++ ions, and ionization fragments of perfluorotributylamine (PTA) was used to react with the background H 2 O to provide the HF + ions. Figure 1. Schematic of the Plasmatron chamber. The plasma source which was monitored in this work was a DC glow discharge, mounted directly to the molecular beam 2 of 5

III. RESULTS AND DISCUSSION A. Plasma Monitoring with the First Mathieu Stability Region Figure 3 shows the EI mass spectrum for the neutral plasma products from the DC glow discharge in C 2 H 6. The C 2 H 6 pressure in the discharge chamber was maintained at 0.11 Torr and the resulting background pressure in the ionizer chamber was 2.9 10-7 Torr. The DC Glow discharge voltage was kept at -3.8 kv, with the discharge current at 7.0 ma.. The ions from the plasma source were blocked off with a high positive voltage on the beam chopper. The electron impact ionizer was operated with the electron energy set at 15 ev. The ion signals at 15, 16 and 26 m/z are due to the products from the glow discharge and these product species are CH 3, CH 4 and C 2 H 2 respectively. Figure 4 shows the appearance potential measurements performed on the C 2 H 2 species. Estimate on the appearance potential by a linear fit to the data yields a fitted value of 12.33 ev (the true value would require a calibration of the appearance potential with a known standard compound). Figure 5 shows the mass spectrum for the positive ions produced from the DC glow discharge in Ar. The Ar pressure in the discharge chamber was maintained at 1.0 Torr. The ions at 40 and 20 m/z are 40 Ar + and 40 Ar ++ respectively. The naturally occurring 36 Ar isotope shows up at 36 m/z and the background H 2 O at 18 m/z. Due to a low concentration of doubly charged Ar ++ ions, the contribution of 36 Ar ++ at 18 m/z is very small. The ion energy distribution for the 40 Ar + is shown in Figure 6. The 40 Ar + from the plasma peaks at about 17.5 ev with a FWHM (full width at half maximum) of about 1eV. This narrow energy distribution indicates that most of the 40 Ar + ions got to the quadrupole mass filter without a collision with other gas species. Figure 7 shows the energy scan for the 40 Ar + ions coming from the DC glow discharge of Ar at 2.0 Torr. Other parameters were kept the same as those used for Figure 6. The broader distribution of the ion kinetic energy demonstrates that the 40 Ar + ions experienced more gas phase collisions at a higher Ar pressure in the plasma chamber. Figure 3. EI mass spectrum for neutral plasma products from C 2 H 6. Figure 5. Positive ions from Ar DC glow discharge plasma. Figure 4. The appearance potential measurements for C 2 H 2 Species. Figure 6. Ion energy scan for Ar + ions from the DC glow discharge at 1 Torr. 3 of 5

signal-to-noise level on the baseline. This demonstrates the high resolving power (high mass resolution) as well as the high abundance sensitivity with the second stability operation of the quadrupole mass filter. Figure 7. Ion energy scan for Ar + ions from the DC glow discharge at 2 Torr. The energy scans shown in Figures 6 and 7 also demonstrate that the energy resolution of the quadrupole deflector energy analyzer is better than 1 ev. Figure 8 shows the mass spectrum for the negative ions from the DC glow discharge in the gas mixture containing SF6. The most dominant ions are F - at 19 m/z. The tailing for the F - peak indicates the presence of ions with very high kinetic energy. Energy scan on the F - ions (not shown here) demonstrated a very broad energy distribution (close to 100 ev). Figure 9. Separation of H 2 O + and 36 Ar ++ in the second stability region. Figure 10 shows the separation of HF + and 40 Ar ++ in the second stability region. The Ar pressure in the ionizer was 9.3 10-6 Torr. About 10% of the Ar ions produced were Ar ++ ions and HF + ions were produced by the chemical reactions between the ionization fragments of perfluorotributylamine (PTA) with the background H 2 O. As a comparison with the results shown in Figure 9, similar mass resolution and abundance sensitivity are shown here. Figure 8. Negative ions from the DC glow discharge in the gas mixture with SF 6. B. Trace H2O and HF in Ar Based Plasmas and Second Mathieu Stability Region Figure 9 shows the separation of H 2 O + and 36 Ar ++ in the second stability region. The Ar pressure in the ionizer was 1.05 10-5 Torr, with a partial pressure of 3.5 10-8 Torr for the 36 Ar isotope. The ratio between Ar + and Ar ++ was about 10%. The H 2 O + ions were due to the residual water background in the ionizer. The FWHM of the H 2 O + peak is about 0.008 amu. The tailing of the H 2 O + peak into the mass position of 36 Ar ++ is negligible and the abundance sensitivity is only limited by the Figure 10. Separation of HF + and 40 Ar ++ in the second stability region. IV. CONCLUSIONS The molecular beam sampling system in plasma analysis avoids the secondary reactions due to collisions with neutrals and other ions after sampling. With two distinct pumping stages, the sampling orifice can be made larger to improving sensitivity, while the scattered background gases 4 of 5

can be more efficiently pumped than possible in a one stage system. The coupling of a quadrupole deflector energy analyzer with the quadrupole mass filter makes it possible to selectively sample the plasma ions at a certain kinetic energy. This energy analyzer can also provide the energy scan capability for the plasma ions. The operation of the quadrupole mass filter in the second Mathieu stability region can be used to detect trace H 2 O and HF in the Ar based plasma. The small differences in the mass-to-charge ratios between H 2 O + and 36 Ar ++ (0.0268 amu) and between HF + and 40 Ar ++ (0.0250 amu) require the high mass resolution and high abundance sensitivity in the second Mathieu stability region. REFERENCES 1. Randall E. Pedder and Richard A. Schaeffer, Proceedings of the 43rd ASMS Conference on Mass Spectrometry and Allied Topics, Atlanta, Georgia, May 21-26, 1995. 2. Randall E. Pedder and Richard A. Schaeffer, Proceedings of the 44th ASMS Conference on Mass Spectrometry and Allied Topics, Portland, Oregon, May 12-16, 1996. 5 of 5