DIRECT EXPERIMENTAL TESTS AND COMPARISON BETWEEN SUB-MINIATURE FISSION CHAMBERS AND SPND FOR FIXED IN-CORE INSTRUMENTATION OF LWR

Similar documents
HIGH TEMPERATURE FISSION CHAMBERS: STATE-OF-THE-ART. L. Martin J.L. Perrin M. Tixier Centrale PHENIX CNPE Creys-Malville Philips Photonics.

Gas-filled Detectors

FEASIBILITY STUDY OF NEW MICROSCOPIC FISSION CHAMBERS DEDICATED FOR ADS

Assessment of Gamma Sensitivity of Platinum SPGD using Monte Carlo Method ,,,,,,

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

Energy device for monitoring 4-10 MeV industrial electron accelerators

Investigation of Prompt Fission Neutron and Gamma Spectra with their covariance matrices. Application to 239 Pu+n th, 238 U+n 1.

CHAPTER 4: NUCLEAR INSTRUMENTATION MODULE 2: LOG RANGE DETECTORS

Lesson 14: Reactivity Variations and Control

Review of Nuclear Heating Measurement by Calorimetry in France and USA C. Reynard-Carette, G. Kohse, J. Brun, M. Carette, A. Volte, A.

Journal of Physics: Conference Series. Related content. To cite this article: C Reynard-Carette et al 2012 J. Phys.: Conf. Ser.

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge

He-3 Neutron Detectors

Validation of the Neutron and Gamma Flux Distributions in the JSI TRIGA Reactor Core

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

A new detector for neutron beam monitoring

A Dummy Core for V&V and Education & Training Purposes at TechnicAtome: In and Ex-Core Calculations

New GCSE 4473/01 ADDITIONAL SCIENCE FOUNDATION TIER PHYSICS 2

New neutron detector based on Micromegas technology for ADS projects

General Overview of Gas Filled Detectors

HR-Z SERIES Mild Radiation Resistance LVDT

Determination of the boron content in polyethylene samples using the reactor Orphée

Code Strategy for Simulating Severe Accident Scenario

Chem 481 Lecture Material 4/22/09

FUEL PERFORMANCE EVALUATION THROUGH IODINE ACTIVITY MONITORING K.ANANTHARAMAN, RAJESH CHANDRA

PhD Qualifying Exam Nuclear Engineering Program. Part 1 Core Courses

Neutronics Experiments for ITER at JAERI/FNS

EXPERIENCE IN NEUTRON FLUX MEASUREMENT CHAINS VERIFICATION AT SLOVAK NPPS

Profile SFR-10 CARNAC FRANCE Saint Paul Lez Durance FRANCE

What do we know from GCSE?

The Nuclear Heating Calculation Scheme For Material Testing in the Future Jules Horowitz Reactor

The moderator temperature coefficient MTC is defined as the change in reactivity per degree change in moderator temperature.

USA HTR NEUTRONIC CHARACTERIZATION OF THE SAFARI-1 MATERIAL TESTING REACTOR

Materials Science. Fission Chamber Calibration Tests at NRU

Experimental Studies on the Self-Shielding Effect in Fissile Fuel Breeding Measurement in Thorium Oxide Pellets Irradiated with 14 MeV Neutrons

Electro - Principles I

Subcritical Multiplication and Reactor Startup

INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS (INAA)

YEAR 11 Physics Unit 1

NEUTRON DIAGNOSTICS FOR VOID MONITORING IN BOILING WATER REACTORS

PoS(FNDA2006)010 FAST NEUTRON DETECTORS BASED ON MICROMEGAS TECHNOLOGY. S. Andriamonje * I. Giomataris and J. Pancin

A Photofission Delayed γ-ray Spectra Calculation Tool for the Conception of a Nuclear Material Characterization Facility

The Lead-Based VENUS-F Facility: Status of the FREYA Project

Task 3 Desired Stakeholder Outcomes

CHARACTERISTICS OF LIGHT CHARGED PARTICLE EMISSION IN THE TERNARY FISSION OF 250 CF AND 252 CF AT DIFFERENT EXCITATION ENERGIES

Temperature Measurement

Adaptation of Pb-Bi Cooled, Metal Fuel Subcritical Reactor for Use with a Tokamak Fusion Neutron Source

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

ESNII + WP7 Fuel Safety

Kr-85m activity as burnup measurement indicator in a pebble bed reactor based on ORIGEN2.1 Computer Simulation

Lamarsh, "Introduction to Nuclear Reactor Theory", Addison Wesley (1972), Ch. 12 & 13

Forms of Ionizing Radiation

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

ANALYTICAL EVALUATION OF THE UNCERTAINTY OF ON-LINE AXIAL POWER DISTRIBUTION MEASUREMENT WITH THE FOUR-SECTION EX-CORE DETECTOR

NUCLEAR ENGINEERING. 6. Amongst the following, the fissionable materials are (a) U233andPu239 (b) U23iandPu233 (c) U235andPu235 (d) U238andPu239

QUALIFICATION OF THE APOLLO 2 ASSEMBLY CODE USING PWR-UO 2 ISOTOPIC ASSAYS.

Radiation Detection and Measurement

Reactors and Fuels. Allen G. Croff Oak Ridge National Laboratory (ret.) NNSA/DOE Nevada Support Facility 232 Energy Way Las Vegas, NV

Polycrystalline CdTe Detectors: A Luminosity Monitor for the LHC

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

Measurement of Average Thermal Neutron Flux for PGNAA Setup

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Original Paper Fission Gas Bubbles Characterisation in Irradiated UO 2 Fuel by SEM, EPMA and SIMS

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

MONTE CALRLO MODELLING OF VOID COEFFICIENT OF REACTIVITY EXPERIMENT

Delayed neutrons in nuclear fission chain reaction

Radiation Detection and Measurement

Nuclear Data for Innovative Fast Reactors: Impact of Uncertainties and New Requirements

JRC Place on dd Month YYYY Event Name 1

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Reactivity Coefficients

Digital simulation of neutron and gamma measurement devices

DETERMINATION OF THE SERVICE LIFE FOR THE EXCORE NEUTRON DETECTOR CABLES IN SEABROOK STATION

A Deterministic against Monte-Carlo Depletion Calculation Benchmark for JHR Core Configurations. A. Chambon, P. Vinai, C.

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

Issues for Neutron Calculations for ITER Fusion Reactor

pickup from external sources unwanted feedback RF interference from system or elsewhere, power supply fluctuations ground currents

Study of X-ray diagnostics for corium-sodium interaction during severe accident scenario

Step 2: Calculate the total amount of U-238 present at time=0. Step 4: Calculate the rate constant for the decay process.

Control of the fission chain reaction

APPENDIX 1 DESCRIPTION OF HOT WIRE ANEMOMETER

Introduction. Introduction. Forces An. Forces An. Forces in Action. Forces in Action. Pressure and Pressure. Pressure and Pressure.

Int. Coaf. Physics of Nuclear Science and Technology

Recent Activities on Neutron Calibration Fields at FRS of JAERI

EVALUATION OF PWR AND BWR CALCULATIONAL BENCHMARKS FROM NUREG/CR-6115 USING THE TRANSFX NUCLEAR ANALYSIS SOFTWARE

QUALIFICATION SPECIFICATION

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

EPRI Project. Hard-to-Measure Nuclides in Effluents

PROPOSAL OF INTEGRAL CRITICAL EXPERIMENTS FOR LOW-MODERATED MOX FISSILE MEDIA

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

EEE4106Z Radiation Interactions & Detection

MONTE CARLO POWER ITERATION: ENTROPY AND SPATIAL CORRELATIONS

Reactor Operation Without Feedback Effects

When a body is accelerating, the resultant force acting on it is equal to its

Year 9 AQA GCSE Physics Revision Booklet

Toward the Realization of Fusion Energy

Study of irradiation effects in materials with high-neutron-flux fission reactors

Physics/Additional Science

Electrocution (large quantities of charge flow through the body to earth) Insulating mats or shoes

Transcription:

DIRECT EXPERIMENTAL TESTS AND COMPARISON BETWEEN SUB-MINIATURE FISSION CHAMBERS AND SPND FOR FIXED IN-CORE INSTRUMENTATION OF LWR G. Bignan, J.C. Guyard Commisariat à l Energie Atomique CE CADARACHE DRN/DER/SSAE BP 1 13108 SAINT PAUL LEZ DURANCE FRANCE C. Blandin, H. Petitcolas Commissariat à l Energie Atomique CE GRENOBLE DRN/DRE/SRS 17, rue des Martyrs 38054 GRENOBLE FRANCE Abstract A fixed in-core instrumentation is an attractive tool for future LWR in order to obtain precious information on the core status (transient follow-up, on-line 3D neutrons flux and power map...). In this context, CEA laboratories have a great experience of the neutron detectors which are major candidates for such instrumentation: Sub-miniature Fission Chamber and Self-powered Neutron Detector. In order to compare advantages and disadvantages of each detector, a direct experimentation is being carried out in the SILOE research reactor. The design of the experiment, the different results and their interpretation are presented in this paper.

Introduction A fixed in-core instrumentation represents a significant improvement for future LWR in order to obtain precious information on the core status (transient follow-up, on-line 3D power map and neutron flux...). In this context, CEA laboratories have a large measure of experience concerning the neutron detectors which are major candidates for such instrumentation: Sub-miniature Fission Chamber and Self-powered Neutron Detector [1,2]. In order to compare the advantages and disadvantages of each detector, two direct experimentations are being carried out at the Siloe Research Reactor: the first one which is under way at the moment (March-November 1996) consists of the comparison between Sub-miniature Fission Chambers and Rhodium SPNDs (e.g. concerning the static mode of the reactor). The second one, which is planned for 1997 (January-September 1997), will consist of the comparison between Sub-miniature Fission Chambers and prompt SPNDs such as hafnium, platinum and cobalt (e.g. concerning the transient mode of the reactor). After a description of the detectors, the design of the experiments is presented. Finally, the first results and their interpretation are given and discussed. The detectors Sub-miniature Fission Chamber (SMFC) Compared to the classical 3 mm diameter fission chamber usually used for mobile instrumentation in LWRs, a technological gap has been made in order to perform a fixed in-core instrumentation; due to the fact that six or seven neutron detectors have to be located axially, a maximum diameter of 1.5 mm is necessary. This led us to design a new technological sub-miniature fission chamber containing about 200 µg of fissile material ( 235 U or ratio 234 U/ 235 U for regenerating deposit) with a tight feedthrough between the fission chamber body and the coaxial wire (see Figure 1). Such a detector is expected to have an efficiency of about 10-18 A/n.cm -2 s -1 and to be directly sensitive to neutron flux. However, a fission chamber needs a power supply ( 30 volts) and with such a geometry (detector body Φ: 1.5 mm, length: 25 mm, coaxial wire 30 meters) needs a careful design to avoid insulation leakage [1]. One of the big interests of the experiment is to know the behaviour of this tight feedthrough (n 6 of Figure 1) under high temperature and high neutron and gamma dose rate. Self-powered Neutron Detector (SPND) As explained before, in the first experiment, only Rhodium SPNDs are used and in the second one, it will be a question of hafnium, platinum and cobalt (this second step being oriented to the transient follow-up). Different shrouding of the detectors (for example steel shrouding) could be used in order to optimise the neutron detection and to evaluate separately: the thermal sensitivity, the epithermal neutron sensitivity and the gamma sensitivity [2,3].

The experiments The experimental tests are and will be performed in the research and irradiation SILOE reactor (water reactor of 35 MW located at the CEA centre in Grenoble). This modular reactor uses plate fuels and has some positions with intense thermal neutron flux (between 5.10 13 n.cm -2 s -1 and 10 14 n.cm -2 s -1 ). Such positions are interesting for testing the mechanical behaviour of the detectors under high neutron and gamma dose rate (leak of insulation?). For the purpose explained above (direct comparison between Fission Chamber and SPND), two experiments are planned. They are described below. The CAFET experiment (ChAmbres à Fissions En Temperature) This first experiment is being carried out at the moment (March-November 1996) and concerns the static mode of the reactor. The CAFET device consists of a thimble in aluminium insulated, from a thermal point of view, with helium gas (see Figure 2). The thimble contains two Sub-miniature Fission Chambers, two Rhodium SPNDs, two thermocouples, a heating coaxial and two copper-cobalt activation detectors, these last two being necessary to evaluate, at the end of the irradiation time, the absolute thermal neutron fluence (it will be about 10 21 n.cm -2 ). The power deposit on the metallic structure due to particle rays (about 2.4 W/g at the thimble location) induces the major part of the heating inside the thimble. A temperature adjustment is also possible using the heating coaxial located inside the thimble. The behaviour of the neutron detectors versus the temperature (especially the Rhodium SPND number 084 and 085 see Figure 2) can be compared to other SPNDs located outside the thimble (SPND number 082 and 083 from Figure 2) which are at the temperature of the reactor coolant water (about 35 C). This CAFET experiment allows us to obtain, for each stabilised irradiation level (e.g. percentage of full power), the following parameters: Global efficiency (A/n cm-2.s-1); Statistical uncertainty; Linearity of the detector response versus the reactor power; Effect of temperature; Behaviour of the insulation (especially for Sub-miniature Fission Chambers).

The VARAPPE experiment (VAriation RApide de PuissancE) This second experiment will be carried out between January and September 1997 and will concern the transient mode. The VARAPPE device is especially designed for the study of the dynamic characteristics of Fission Chambers and prompt SPNDs. It consists of placing in a stainless steel thimble, two Sub-miniature Fission Chambers and various prompt SPNDs with different emitting material such as: hafnium, platinum and cobalt (see Figure 3). The transient mode will be obtained by vertically moving the detectors in front of a cadmium foil at a speed of about 1 ms -1. For each detector, it should be possible to evaluate: The response time; The prompt current part obtained with the moving compared to the equilibrium signal. Technological improvements of SPND performed in order to improve the insantness will be tested during this second experiment (compensation of the sheath current, minimisation of the current coming from γ ray...) [4]. First results and interpretation An irradiation cycle of the SILOE Reactor (about one month) consists of three phases: At start-up, different steps of neutron flux at different percentages of nominal power; A long stable phase at nominal power; A slow shutting down of the reactor at the end of the cycle. The value of the neutron flux inside and outside the thimble has been evaluated using the APOLLO neutron transport code [5]. Previous work has indicated the good confidence of this approach. The Sub-miniature Fission Chambers (SMFC) For the different irradiation levels, the two SMFCs follow, very precisely, the value of the thermal neutron flux as indicated in the table below (and in Figure 4): Power Reactor (MW) Thermal Neutron Flux (n.cm-2s-1) Average signal det 1 (volts) 15 4,42 10 13 0,350 1,050 20 5,78 10 13 0,452 1,276 25 7,14 10 13 0,541 1,512 30 8,23 10 13 0,597 1,716 35 9.89 10 13 0,659 1,986 Average signal det 2 (volts)

Such acquisitions lead to the following results: There is a very good linearity between the signals and the neutron flux; The efficiency ε 1 of Fission Chamber number 1 is about 7 10-19 A/n.cm -2 s -1 ; The efficiency ε 2 of Fission Chamber number 2 is about 2 10-18 A/n.cm -2 s -1. This difference between detector 1 and 2 is due to the difference of 235 U deposit inside the SMFC (70 µg for detector 1 and 200 µg for detector 2); The statistical uncertainty (at 2 standard deviation) is of 4% for detector 1 and of about 2% for detector 2 (for the full operating range); There is no change in the behaviour of the SMFC due to either temperature or neutron and gamma irradiation (the insulation resistance without flux is about 10 11 Ω); The signal loss due to the consumption of 235 U nuclei is about 4,5% per irradiation cycle (fluence of 7.8 10 19 n.cm -2 ). As described here, our first approach consists of using the average current given by the detector as in saturation mode, that is to say: i = Nq = Φnεq With: i: average current (A) N : average number of events in the detector/s q : average charge per event (c) Φ n : thermal neutron flux (n.cm -2 s -1 ) ε: efficiency (A/n.cm -2 s -1.C) However, due to the low value of the applied voltage (30 V) we have to be sure that there is no shift of the efficiency. It is assumed using the fluctuation mode (i.e. Campbelling mode [6]) in the following manner. From an electronic point of view, we have the next diagram: V H.V. R C

With: R: entrance resistance of the electronic amplifier (10 4 Ω) C: capacity of the cable ( 1 pf) HV: High Voltage (V) V: measured signal (V) 1 t If h(t) is the impulse response of the circuit; h( t) = C e RC We can say (if q 2 >> q 2 ): V = Nq σ 2 v 0 + = Nq 0 2 h(t)dt + 2 h (t)dt Consequently: V 2 σv 2 = 2NRC = 2RCΦ n ε 2 V 1 or Φ n = 2 2RCε σv This second approach is under analysis at moment. The first results confirm the validity of the Campbelling mode and indicate the good complementarity between the two approaches. The Self-Powered Neutron Detector For the different irradiation levels, the SPND follow, very precisely, the value of the reactor power as indicated in Figure 5 which gives the thermal neutron flux versus the reactor power obtained by thermic assessment. The acquisitions lead to the following results: The efficiency of Rhodium SPND is of 5,3 10-21 A/n.cm -2 s -1 ; The uncertainty on the thermal neutron flux evaluation is of 6% (at 2 standard deviation); There is a very good linearity between the thermal flux given by SPND and reactor power; There is no change in the SPND behaviour due to the temperature (the insulation resistance is of about 7 10 8 under neutron flux whatever the SPND see Figure 5).

Conclusion Such direct experiment is very fruitful in order to compare on-line the sensitivity and the behaviour of the major candidates for fixed in-core instrumentation. It can be said that the New Technology Fission Chamber looks promising in terms of sensitivity and uncertainty which are profitable compared to SPND. Nevertheless, this technology is more complex than the SPND one (need for power, risk of insulation leakage) in terms of reliability and robustness. The second experiment planned in 1997 (VARAPPE device described earlier) will allow us to obtain, by the end of 1997, a global feasibility document including SMFC, slow and optimised prompt SPND. REFERENCES [1] G. BIGNAN, J.C. GUYARD Sub-miniature Fission Chamber with Tight Feedthrough PATENT CEA n 94-14293 (November 1994). [2] M. AGU, H. PETITCOLAS Self-powered detector response to thermal and epithermal neutron flux Nuclear Science and Engineering n 107 (1991). [3] M. AGU, H. PETICOLAS Self-powered neutron detectors for measuring epithermal neutron flux American Society for Testing and Materials (ASTM) Philadelphia (1989). [4] C. BLANDIN, H. PETICOLAS Prompt SPND for instantaneous fuel power determination during fast power transients Ninth International Symposium on Reactor Dosimetry (PRAGUE SEPT 1996) [5] A. KAVENOKY, R. SANCHEZ The APOLLO Spectrum Code International Conference on Reactor Physics PARIS (APRIL 1987) [6] C.F. KNOLL Radiation detection and measurement WILEY et SONS (1989)

Figure 1. New technology sub-miniature fission chamber Figure 2. Schematic view of the CAFET device

Figure 3. Schematic view of the VARAPPE device

Figure 4. Average signal versus neutron flux for fission chambers n 1 and 2 (counting time 10s) Figure 5. SPND responses