H. Maesaka*, K. Togawa, T. Inagaki, K. Onoe, T. Tanaka, A. Higashiya, H. Baba, H. Matsumoto, H. Tanaka, Y. Otake and T. Shintake FLS 2010, SLAC

Similar documents
Status of X-ray FEL/SPring-8 Machine Construction

The CeB6 Electron Gun for the Soft-X-ray FEL Project at SPring-8

Free-electron laser SACLA and its basic. Yuji Otake, on behalf of the members of XFEL R&D division RIKEN SPring-8 Center

H. Maesaka*, H. Ego, T. Hara, A. Higashiya, S. Inoue, S. Matsubara, T. Ohshima, K. Tamasaku, H. Tanaka, T. Tanikawa, T. Togashi, K. Togawa, H.

SCSS Prototype Accelerator -- Its outline and achieved beam performance --

PAL LINAC UPGRADE FOR A 1-3 Å XFEL

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

Short Pulse, Low charge Operation of the LCLS. Josef Frisch for the LCLS Commissioning Team

Generation and characterization of ultra-short electron and x-ray x pulses

FURTHER UNDERSTANDING THE LCLS INJECTOR EMITTANCE*

Low slice emittance preservation during bunch compression

LOLA: Past, present and future operation

4 FEL Physics. Technical Synopsis

REVIEW OF THE WORLDWIDE SASE FEL DEVELOPMENT

Linac optimisation for the New Light Source

X-ray Free-electron Lasers

LCLS-II SCRF start-to-end simulations and global optimization as of September Abstract

Microbunching Workshop 2010 March 24, 2010, Frascati, Italy. Zhirong Huang

Development of Cs 2 Te photocathode RF gun system for compact THz SASE-FEL

Towards a Low Emittance X-ray FEL at PSI

LCLS Injector Prototyping at the GTF

Femto-second FEL Generation with Very Low Charge at LCLS

Beam Dynamics. Gennady Stupakov. DOE High Energy Physics Review June 2-4, 2004

FLASH/DESY, Hamburg. Jörg Rossbach University of Hamburg & DESY, Germany - For the FLASH Team -

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Linac Driven Free Electron Lasers (III)

Small Emittance Sources/Guns

ASTRA simulations of the slice longitudinal momentum spread along the beamline for PITZ

X-band Experience at FEL

Dark Current at Injector. Jang-Hui Han 27 November 2006 XFEL Beam Dynamics Meeting

Injector Experimental Progress

Status of Proof-of-Principle Experiment of Coherent Electron Cooling at BNL

Linac Based Photon Sources: XFELS. Coherence Properties. J. B. Hastings. Stanford Linear Accelerator Center

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

FACET-II Design Update

What have we learned from the LCLS injector?*

Experimental Optimization of Electron Beams for Generating THz CTR and CDR with PITZ

SPARCLAB. Source For Plasma Accelerators and Radiation Compton. On behalf of SPARCLAB collaboration

THz Electron Gun Development. Emilio Nanni 3/30/2016

Diagnostic Systems for High Brightness Electron Injectors

Echo-Enabled Harmonic Generation

R&D experiments at BNL to address the associated issues in the Cascading HGHG scheme

Beam Echo Effect for Generation of Short Wavelength Radiation

Jlab FEL Photoemission DC Guns

Commissioning of the new Injector Laser System for the Short Pulse Project at FLASH

Laser acceleration of electrons at Femilab/Nicadd photoinjector

OVERVIEW OF FELS UNDER CONSTRUCTION INCLUDING FELs AT FERMI ELETTRA, SPRING-8 AND FRASCATI SPARC

Summary of COTR Effects.

Coherence properties of the radiation from SASE FEL

Recent Status of Polarized Electron Sources at Nagoya University

ICFA ERL Workshop Jefferson Laboratory March 19-23, 2005 Working Group 1 summary Ilan Ben-Zvi & Ivan Bazarov

Simulations of the IR/THz Options at PITZ (High-gain FEL and CTR)

New Electron Source for Energy Recovery Linacs

AREAL Test Facility for Advanced Accelerator and Radiation Sources Concepts

SPPS: The SLAC Linac Bunch Compressor and Its Relevance to LCLS

Transverse emittance measurements on an S-band photocathode rf electron gun * Abstract

X-Band RF Harmonic Compensation for Linear Bunch Compression in the LCLS

ILC Particle Sources -Electron and PositronMasao KURIKI (Hiroshima University)

Vertical Polarization Option for LCLS-II. Abstract

Simulations of the IR/THz source at PITZ (SASE FEL and CTR)

START-TO-END SIMULATIONS FOR IR/THZ UNDULATOR RADIATION AT PITZ

VELA/CLARA as Advanced Accelerator Studies Test-bed at Daresbury Lab.

Waseda University. Design of High Brightness Laser-Compton Light Source for EUV Lithography Research in Shorter Wavelength Region

Diagnostics at the MAX IV 3 GeV storage ring during commissioning. PPT-mall 2. Åke Andersson On behalf of the MAX IV team

An Adventure in Marrying Laser Arts and Accelerator Technologies

OPTIMIZATION OF COMPENSATION CHICANES IN THE LCLS-II BEAM DELIVERY SYSTEM

EXPERIMENTAL STUDIES WITH SPATIAL GAUSSIAN-CUT LASER FOR THE LCLS PHOTOCATHODE GUN*

DIAGNOSTIC TEST-BEAM-LINE FOR THE MESA INJECTOR

S2E (Start-to-End) Simulations for PAL-FEL. Eun-San Kim

Demonstration of Energy-Chirp Control in Relativistic Electron Bunches at LCLS Using a Corrugated Structure. Karl Bane, 7 April 2017,, KEK

WG2 on ERL light sources CHESS & LEPP

High average current photo injector (PHIN) for the CLIC Test Facility at CERN

Physical design of FEL injector based on performance-enhanced EC-ITC RF gun

Photo Injector Test facility at DESY, Zeuthen site

Undulator radiation from electrons randomly distributed in a bunch

SwissFEL INJECTOR DESIGN: AN AUTOMATIC PROCEDURE

4GLS Status. Susan L Smith ASTeC Daresbury Laboratory

Research Topics in Beam Physics Department

The New Superconducting RF Photoinjector a High-Average Current & High-Brightness Gun

Chopping High-Intensity Ion Beams at FRANZ

X-band RF driven hard X-ray FELs. Yipeng Sun ICFA Workshop on Future Light Sources March 5-9, 2012

SLS at the Paul Scherrer Institute (PSI), Villigen, Switzerland

LCLS Commissioning Status

Research Laboratory for Quantum Beam Science

Hiromitsu TOMIZAWA XFEL Division /SPring-8

Experimental Measurements of the ORION Photoinjector Drive Laser Oscillator Subsystem

Investigation of the Feasibility of a Free Electron Laser for the Cornell Electron Storage Ring and Linear Accelerator

Operational Performance of LCLS Beam Instrumentation. Henrik Loos, SLAC BIW 2010, Santa Fe, NM

Observation of Coherent Optical Transition Radiation in the LCLS Linac

Potential use of erhic s ERL for FELs and light sources ERL: Main-stream GeV e - Up-gradable to 20 + GeV e -

Length of beam system = 910m. S. Reiche X var = ~50m ~ 650m / Y. Kim FEL-KY ~150m. ~60m. LaserHutch2 (access during operation)

The VELA and CLARA Test Facilities at Daresbury Laboratory Peter McIntosh, STFC on behalf of the VELA and CLARA Development Teams

Introduction to single-pass FELs for UV X-ray production

THE LCLS-II INJECTOR DESIGN*

BEAM TESTS OF THE LHC TRANSVERSE FEEDBACK SYSTEM

INNOVATIVE IDEAS FOR SINGLE-PASS FELS

STATUS OF THE NOVOSIBIRSK ENERGY RECOVERY LINAC

ACCELERATOR LAYOUT AND PHYSICS OF X-RAY FREE-ELECTRON LASERS

MaRIE. MaRIE X-Ray Free-Electron Laser Pre-Conceptual Design

Dark current at the Euro-XFEL

Transcription:

H. Maesaka*, K. Togawa, T. Inagaki, K. Onoe, T. Tanaka, A. Higashiya, H. Baba, H. Matsumoto, H. Tanaka, Y. Otake and T. Shintake FLS 2010, SLAC 1

Introduction Outline X-ray FEL Project at SPring-8 SCSS Test Accelerator Electron gun design Performance Emittance measurement Coherent OTR Search Operational experience Summary 2

3

4 X-ray FEL Project at SPring-8 X-ray wavelength: < 0.1 nm Self-amplified spontaneous emission (SASE) process Beam energy: 8 GeV Key technologies Low-emittance thermionic electron gun: 0.6 π mm mrad High-gradient C-band accelerator: 35 MV/m Short-period in-vacuum undulator: λ u = 18 mm, K < 2.2 First XFEL light will be delivered in 2011.

5 SCSS Test Accelerator To check the feasibility of XFEL Extreme ultraviolet (EUV) FEL facility Wavelength: 50 60 nm for saturated output Beam energy: 250 MeV Electron gun is identical to that of XFEL Saturated EUV laser light is stably generated. Trend graph of FEL intensity

6

Thermionic-Gun-based Injector Simple Thermionic cathode with heater and high-voltage power source No laser system Stable Stable emission rate Long life time But low current and long pulse length Use fast chopper and velocity bunching No grid electrode, because it causes emittance degradation. 1ns Cathode φ3mm 500kV 3µs 1A B Collimator Pulse deflector (φ5mm) (Stripline electrodes) 1ns, 1A 238 MHz Pre-buncher cavity 7

Requirements from XFEL Gun Design Normalized emittance: < 1 π mm mrad Beam current: > 1 A Bunch length: 1 ns (after the chopper) Bunch charge: 1 nc Voltage: 500 kv (as high as possible) Cathode To reduce space-charge effect CeB 6 single crystal 3mm diameter ~ > 1400 deg.c for 1A beam Thermal Emittance K. Togawa et al., Phys. Rev. ST Accel. Beams 10, 020703 (2007) 8

Cathode Assembly 10MV/m CeB6 cathode is mounted in a graphite sleeve Heated to ~ 1400 deg.c by graphite heater 500 kv pulse voltage (3µs) is applied to 50 mm gap (10 MV/m) 3mm 9

High Voltage Power Supply 50 kv Inverter power supply Voltage stability: ~10 ppm (rms) Oil-filled compact pulse modulator ~ 3 µs pulse Same as klystron power source Gun high-voltage tank Pulse transformer steps up the voltage to 500 kv. AC 420V Dummy tube absorbs extra power Stable impedance and easy cooling 50kV Inverter power supply Thyratron Pulse forming network Oil-filled compact pulse modulator 1:21 Dummy tube ~200A 500kV Gun high-voltage tank Beam 1A Cathode Pulse transformer 10

11

Normalized Emittance Charge density profile Phase space profile 0.6 π mm mrad (rms) Without 10% tail component Energy: 500 kev Current: 1 A Measured by double-slit method 12

13 Estimation of Slice Emittance from SASE-FEL Energy Curve FEL energy curve was compared with simulation Slice emittance of SCSS test accelerator: ~ 0.7 π mm mrad Gun emittance is conserved after x300 bunch compression

14

Coherent OTR Search Courtesy of K. Togawa Bunch compression ratio was changed by the RF phase of S-band accelerator. SCSS test accelerator 250MeV Superposition of 5 shots Very stable Observed point 1mm OTR Image 15

Courtesy of K. Togawa OTR Intensity v.s. Bunch Compression OTR intensity as a function of S-band RF phase. Compression factor (calculation) is also plotted. Lasing point Total compression factor ~ 300 SCSS test accelerator 250 MeV ~0.25 nc/bunch Intensity was normalized by charge and γ 2 We didn t observe non-linear amplification of OTR. The gun emits a temporally and spatially smooth beam. 16

17

18 Operation at the SCSS test accelerator Cathode heater is always on. Except for shutdown periods CeB6 surface is cleaned by evaporation (10nm/hour) Sometimes cathode temperature is adjusted to keep the emission. (once per three month) High voltage is turned on at 9:00 and off at 19:00 on weekdays Fault rate Less than once per day. Mainly caused by thyratron misfire. No spark around the cathode. Down time due to the gun fault is only 0.4 %.

19 History of the SCSS test accelerator 2001-2003: Gun R&D 2004-2005: Construction of the SCSS test accelerator 2005 Oct.: Started operation 2006 Jun.: First lasing 2006 Oct.: Dummy tube trouble 2007 Oct.: FEL saturation 2008 Jan.: Cathode replacement after 20,000 hour operation (heating time) 2010 Aug.: Cathode replacement?

CeB6 cathode after 20,000 hour heating. Courtesy of Shintake-san The cathode surface became concave of 0.2 mm deep from the initial flat surface. It corresponds to evaporation speed of 10 nm/hour ( 10 nm/h x 20,000 h = 200 micron-meter) Concave geometry made beam slightly focusing, but did not break emittance. Electron microscope study showed (1) Surface is fairly smooth, (2) covered by carbon contamination (lowered electron emission). 20

Future Plan New gun for XFEL Identical to the SCSS test accelerator Delivered soon High-voltage test will be done in the coming April Possible R&D areas More stable power source Thyratron Solid-state switch Dummy tube more stable and longer life dummy load Multi-bunch operation Done by longer pulse generator for the chopper Low charge operation with better emittance Need thin collimator or thin cathode Higher current We can do that with higher cathode temperature. But cathode life time is shortened. Higher voltage Need improvements to prevent the cathode and the insulator from arcing Higher repetition rate Cathode itself is OK for khz order Depending on the high voltage power supply 21

22 Summary Thermionic gun CeB6 single crystal 3mm diameter ~> 1400 deg.c 500 kv, 1 A Low emittance and smooth beam 0.6 π mm mrad No coherent OTR No spiky modulation Operation experience Stably operated for four years. Fault rate: less than once per day Down time: only 0.4 % (2008 2009) Cathode lifetime: ~ 20,000 hours (heating time)

23

24

Chopper 1ns bunch is extracted by pulse deflector from 3 µs beam. No grid electrode 1ns chopped Cathode B φ3mm 500kV 3µs 1A 1ns, 1A Collimator (φ5mm) Pulse deflector (Stripline electrodes) 238 MHz Pre-buncher cavity 25

26 Beam Profile and Emittance after the Chopper Fluorescent screen image Emittance Round, flat and smooth beam is generated. Emittance was measured by slit scan method. 1.1 π mm mrad (Without 10% tail) This value can be larger than the true emittance because of the space charge effect and the poor resolution of the fluorescent screen

Beam trajectory 27

Emission Curve 28

29 Longitudinal Bunch Profile Measured by RF Zero Phasing Method Courtesy of K. Togawa Peak Current vs. S-band TWA Phase (Data) (Calculation)

30 OTR Measurement Setup Courtesy of K. Togawa Gold target (t~250nm) Transmission of vacuum window Kovar glass Quartz Sapphire Sapphire window Wavelen`gth [µm] Sensitivity of CCD camera

2008/01/28 First experience, but team did nice work. We replaced CeB6 crystal in SCSS accelerator, after 20,000 hour heating. Courtesy of Shintake-san Anode flange had color change. 31

32 Fault Statistics FY 2008 FY 2009 Total Operation time Total down time Gun down time # of Gun faults 116444 min. (~200 days) 83552 min. (139 days) 199996 min. 3861 min. 3.3 % 3193 min. 3.8 % 7054 min. 3.5 % 640 min. 0.55 % 227 min. 0.27 % 867 min. 0.43 % 147 (~0.7 /day) 43 (0.3 /day) 190 (~0.6 /day) Gun faults Mainly comes from the trip of the high-voltage power supply Down time is only 0.4 %. Trip rate: less than once per day

Dummy Tube Trouble Occurred in Oct. 2006. Cathode of the dummy tube is shorted to the ground. Inside of the vacuum vessel. Insulation of the heater cable was insufficient. Now, it s improved. 33

Choice of Thermionic Electron Source We chose the thermionic gun followed by chopper and velocity bunching system. Using the thermionic emitter, the system becomes simple, eliminating use of laser system (for photo-cathode gun), which requires more frequent maintenance than the thermionic cathode gun. We believe electron cloud emitted from the thermionic cathode has smooth temporal and spatial distribution. There is no any internal structure. It is the nature of the thermionic electron emission (statistics). In the chicane bunch compressor, CSR effect will amplify the density modulation in the incoming electron bunch. Fluctuation of laser beam (fine structure of temporal power profile) might be a source of CSR instability. Quiet electron beam from the thermionic emitter is desirable to cure CSR instability. (need to see X-ray lasing) Thermionic gun system does not require the laser heater to smear the fine structure in the bunch. For future upgrade, seeding scheme require smooth beam. 34

35 Emittance Record in SCSS to XFEL/SPring-8 2001~2003 SCSS R&D CeB 6 thermionic gun 2004~2005 SCSS Test Accelerator Construction 0.6 π.mm.mrad @ 1 A DC, 500 kv 2006 June First Lasing 49 nm at test accelerator. 2007 Oct. Saturation at 50~ 60 nm X 300 Compression 2006 April XFEL/SPring-8 Construction was funded. Beam optics design. Technical design. 2007 Technical design, contract. 2008 Mass-production of hardware components. 2009 March. Linac, Undulator hall building completed. Hardware installation. 0.7 π.mm.mrad @ 300 A, 0.7 psec, 250 MeV, 0.3 nc X 10 Compression 2010 Oct. High power processing 8 GeV accelerator. 2011 April~ Beam commissioning. First lasing at 1 A. 0.8 π.mm.mrad @ 3k A, 8GeV

1 π mm-mrad emittance beam from thermionic cathode was challenge, or crazy? this picture is copied from LCLS Conceptual Design Report, SLAC-R-593 UC-414 Eliminating control grid from cathode. Smaller size cathode, from 8 mm to 3 mm diameter. Higher gun voltage, 150 kv to 500 kv. Using single crystal CeB6 cathode. 36

37 Thermionic Gun looks better. RF-Photocathode gun. Thermionic gun The non-linear space charge field runs with bunch. emittance increases and energy spread increases. Time dependent rf-kick can be cured by solenoid. Electrons run in static field. Uniform beam linear field no emittance dilution no energy spread Fluctuations will be copied from the laser to the electron.

38 and, we need a quiet beam. Intensity modulation on laser pulse will be copied on electron density coming out from RF photocathode It might be a source (seeding) of CSR instability.

39 Source of Modulation in Photocathode RF-Gun Laser two color mixing P 1 λ 1 multi-line oscillation in high gain medium λ 2 P 2 This modulation is copied on electron beam and cause CSR instability. Even a small power cause intense modulation, due to heterodyne amplification. P = 1 W, P = 10 mw P = 200 mw 1 2 B f = f f B 1 2 c c c f = = λ λ λ λ B λλ 1 2 λ λ 2 1 2 1 B = 1 2 I THz laser source uses this. λ = 501 nm, λ = 500 nm λ = 250 µ m I 2 I / I max min 2 1 M = = I max + I min 1 + I 2 / I 1

Modulation transfer (Smearing effect) 40

41 Modulation Transfer T. Shintake, "Focal Point Laser Field as Optical Seeder", Proc. FEL2006, Berlin Germany RF-Gun carries modulation wavelength 1 um or longer to downstream, and amplified with CSR and convert into visible light in chicane through wavelength compression

Use Small Size Cathode First Strategy for smaller thermal emittance 42 Thermionic cathode Operating Temperature 1500 C w e 3 = kt B = 223 mev 2 Thermal Emittance γ rc kt B ε xn = = 2 2 mc 0 0.4 π mm-mrad RF photo-cathode injector. Assume ~ 2 mm laser spot size. 3mm diameter cathode (CeB6) is used in a low emittance injector. (SCSS SPring-8/RIKEN) γ rc kt B e ε xn = = 0.35 π mm-mrad 2 2 mc 0 T e is measured effective electron temperature of copper cathode using 266 nm laser (ref. 2). k T e = 0.27 ev (2360 C). Same order!

43 CeB6 Thermionic Electron Gun K. Togawa

1500 deg.c. Highest temp. in system Evaporating CeB6 at 1 nm/hour Self Surface Cleaning Surface Smoothing Very stable e-emission 1 % decay per month trim heater power each 3-months Long life ~20,000 hour Graphite Heater 1700 deg. C CeB6 Single Crystal 3 mm diameter 1 A, 10 MV/m, 500 kv Cathode Holder (graphite) forms parallel field four slots provide spring action. SUS316 (clean-z) Target image of pyro-temp measurement. Edge does not case high voltage break down 44

Operational Experience of 500 kv Gun Gun sits inside HV pulse tank, filled with oil. Applying 500 kv pulse. Electro-polished SUS 3 micro-sec pulse driven by klystron modulator. SUS316 (clean-z) No baking HV processing is a few hours to reach 500 kv No HV breakdown at 500 kv for 4 years, daily operation. 45

Measured Emittance at the Gun 46

47 Q&A on the CeB6 electron gun Why don t we use LaB6? CeB6 has twice longer lifetime than LaB6. Can we use needle shape cathode like electron microscope for the FEL? No. We need Ampere class beam. Available beam current density from CeB6 cathode is < 30 A/cm2. To obtain 1 A, we need at least 2 mm diameter. The current is also space charge limited. For longer lifetime, it is better to keep cathode temperature lower, and lower current density, thus we use 3 mm diameter cathode. Can we apply DC voltage on the gun? No. DC high voltage will cause a large dark current flow from cathode electrode and HV breakdown. At pulse width shorter than 10 micro-sec, HV breakdown limit becomes a few times higher than DC limit. Thus we use 3 micro-sec, 500 kv pulse driven by pulse power modulator. Do we need to apply mechanical polish the cathode electrode? No, polishing with diamond powder causes HV breakdown. Electro polishing is the best choice for stainless steel.

CeB6 Crystal Cathode has reached its lifetime after 20,000 hour operation. 48 January 2008, right after the new year holiday, the emission current decreased quickly by 50%. It has been nicely running for user experiment till end of December 2007, (60 nm full saturation) This crystal was installed in October 2005. Lifetime is 20,000 hours, which is shorter than we expected. But, it is fairly long enough, we decided to regularly change the crystal every year at summer shutdown. To replace cathode and tuning beam to recover full saturated lasing was two-week job.