PRINCIPLE OF ICP- AES

Similar documents
AN INTRODUCTION TO ATOMIC SPECTROSCOPY

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Classification of spectroscopic methods

PRINCIPLES OF AAS atomization flame furnace atomization absorption

Atomic Emission Spectroscopy

ATOMIC SPECROSCOPY (AS)

a. An emission line as close as possible to the analyte resonance line

Atomic Absorption & Atomic Fluorescence Spectrometry

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

2101 Atomic Spectroscopy

Molecular Luminescence Spectroscopy

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Atomic Absorption Spectroscopy

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

OES - Optical Emission Spectrometer 2000

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

9/13/10. Each spectral line is characteristic of an individual energy transition

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

3 - Atomic Absorption Spectroscopy

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

ICP-OES Application Note Number 35

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Atomic Spectroscopy AA/ICP/ICPMS:

Ionization Techniques Part IV

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

SmartNotes. What is meant by the term interference?

Emission spectrum of H

Atomic Absorption Spectroscopy (AAS)

Determination the elemental composition of soil samples

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

COMPARISON OF ATOMIZERS

high temp ( K) Chapter 20: Atomic Spectroscopy

Atomic absorption spectroscopy

Ch. 8 Introduction to Optical Atomic Spectroscopy

CH. 21 Atomic Spectroscopy

Lecture 7: Atomic Spectroscopy

Chemistry Instrumental Analysis Lecture 17. Chem 4631

CHAPTER 4: ANALYTICAL INSTRUMENTATION

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Electromagnetic Radiation (EMR)

Handbook of Inductively Coupled Plasma Spectrometry

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Lecture 16 Instrumentation for ICP AES-VIII-Instruments

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

Chemistry Instrumental Analysis Lecture 18. Chem 4631

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

DEPARTMENT OF CHEMISTRY UNIVERSITY OF SWAZILAND

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Atomization. In Flame Emission

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

INTRODUCTION TO OPTICAL ATOMIC SPECTROSCOPY (Chapter 8)

Basic Digestion Principles

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

II. Spectrophotometry (Chapters 17, 19, 20)

DETERMINATIONS OF THE POLLUTION LEVEL OF THE ENVIRONMENT WITH HEAVY METALS

Analysis Repeatability of Trace and Major Elements in a Water Sample

A Review on Inductively Coupled Plasma Optical Emission Spectrometry

BRIEFING 1730 THEORY AND PRACTICE OUTLINE

Spectrometric Methods of Analysis. OCN 633 Fall 2013

FLAME PHOTOMETRY AIM INTRODUCTION

Chapter 8: An Introduction to Optical Atomic Spectrometry

Spectroscopy Problem Set February 22, 2018

ICP-OES DETERMINATION OF IRON. Introduction:

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

very high temperature for excitation not necessary generally no plasma/arc/spark AAS

Prof. Dr. Biljana Škrbić, Jelena Živančev

Optimizing Analytical Performance in ICP-OES Applications

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Sample Analysis Design Polyatomic Interferences

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Sources of Errors in Trace Element and Speciation Analysis

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Liberty Series II. Liberty. Liberty Series II. Analytical Methods book. Publication No October (i) Publication date: 10/99

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Analysis of domestic sludge using the Agilent 4200 MP-AES

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

NATURE AN POLUUTION DEGREE OF WATER ASSETS STUDIED BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Evaluation, Control and Diagnosis of an ICP Through Simple Experiments

Spectroscopy Division, and * Central Workshop, Bhabha Atomic Research Centre, Trombay, Mumbai , India

Partial Energy Level Diagrams

Plasma Interface Element2

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Transcription:

INTRODUCTION Non- flame atomic emission techniques, which use electrothermal means to atomize and excite the analyte, include inductively coupled plasma and arc spark. It has been 30 years since Inductively Coupled Plasma Atomic Emission Spectrometry ICP AES ( also known as ICP- optical emission spectrophotometry ICP-OES) began to be widely used, and is now one of the most versatile methods of inorganic analysis. Its features are often compared to atomic absorption spectrophotometry, in which the excitation temperature in the range 2000 to 3000 K, while the excitation temperature of argon ICP is 5000 to 10000 K, which efficiently excites many elements. Also, using inert gas (argon) makes oxides and nitrides harder to be generated.......

PRINCIPLE OF ICP- AES An ICP source consists of a flowing stream of argon gas ionized by an applied radio frequency field. This field is inductively coupled to the ionized gas by water-cooled coil surrounding a quartz torch that supports and confines the plasma. A sample aerosol is generated in an appropriate nebulizer and spray chamber and is carried into the plasma through a tube located within the torch. The sample aerosol is directed into the ICP, subjecting the constituent atoms to temperature of about 5000 to 10000 o K. This high temperature results in almost complete dissociation of molecules, significant reduction in chemical interferences. The high temperature of the plasma excites atomic emission efficiently. The radiation emitted by the excited atoms is recorded by one or more optical spectrometers and when calibrated against standards the technique provides a quantitative analysis of the original sample.

INSTRUMENTATION : There are four basic components to an ICP AES Instrument. An ICP-AES instrument consists of a sample delivery system, an IC plasma to generate the signal, one or more optical spectrometers to measure the signal, and a computer for controlling the analysis.

INSTRUMENTATION : cont d 1- Sample delivery system There are three basic parts to the sample introduction system. The Peristaltic pump draws up sample solution and delivers it to the Nebulize which converts the solution to an aerosol that is sent to the Spray chamber where The larger droplets fall to the bottom of the chamber and exit through the drain as mentioned in FAES..Various types of spray chambers commonly used.

INSTRUMENTATION : cont d 2 - IC plasma : The device which produces the IC plasma is commonly referred to as the ICP torch. It consists of two to four Argon flows depending on the manufacturer: Nebulizer gas (inner Argon flow) carries the analyte aerosol Sheath gas for producing a laminar flow to improve low excitation energy elements eg group I & II elements

ICP torch Torch is surrounded by high-energy induction coil connected to radio frequency generator which produce large electrical discharge in the troch. Resistance in the movement of electrons and argon gas through the quartz tubes leads to generation of heat. Sample is introduced in the argon stream in form of liquid aerosol or vapor This step allow the evaporation of the solvent. The next steps are atomization and excitation of the analyte.

INSTRUMENTATION : cont d 2 - IC plasma.. continued : components of an ICP torch

INSTRUMENTATION : cont d 2 - IC plasma.. continued : The sample aerosol is directed into the center of the plasma. The energy of the plasma is transferred to the aerosol. The main function of the energy source is to get atoms sufficiently excited such that they emit light. The temperature of the plasma is very high and varies from zone to zone.

INSTRUMENTATION : cont d 2 - IC plasma : the Radio Frequency generator the Load coil the Torch

INSTRUMENTATION : CONT D 3- Spectrometer Once the atoms in a sample have been excited by the plasma, they will emit radiation at specific wavelengths. No two elements will emit radiation at the same wavelengths. The function of the spectrometer is to diffract the emitted radiation from the plasma into wavelengths. Then each wavelength will be directed to a detector. These detectors are connected to a computer for data analysis..

APPLICATIONS Plasma sources are rich in characteristic emission lines, which makes them useful for both qualitative and quantitative elemental analysis. The inductively coupled plasma yield significantly better quantitative analytical data than other emission sources do. The excellence of these results stems from their high stability, low noise, low background, and freedom from interferences. ICP-AES is a major technique for elemental analysis. The sample to be analyzed, if solid, is normally first dissolved and then mixed with water before being fed into the plasma.

Cont d Trace elements in a wide variety of aqueous matrices: drinking water, river, lake and ground water, waste water and effluent, and seawater. Trace elements in solids after digestion: sediment, soil, sludge, road dust, air particulate matter, plant tissue and grain, rocks and minerals, etc. Trace elements in samples of body fluids, including blood, plasma, and urine.

ICP - AES Advantage : 1. The plasma provides simultaneous excitation of many elements. 2. The analyst is not limited to analytical lines involving ground state transitions but can select from first or even second ionization state lines. For the elements Ba, Be, Mg, Sr, Ti, and V, the ion lines provide the best detection limits. 3. The high temperature of the plasma ensures the complete breakdown of chemical compounds (even refractory compounds ) and impedes the formation of other interfering compounds e.g. oxides, thus virtually eliminating matrix effects.

4. The ICP torch provides a chemically inert atmosphere and an optically thin emission source, that is not subject to self absorption except at very high concentrations. 5. Excitation and emission zones are spatially separated : this results in a low background. Argon is Inert non reactive with sample. 6. Low background, combined with a high S/N ratio of analyte emission, results in low detection limits, typically in the ppb range. 7-Wide linear region of analytical curve. Analysis of samples from ppb to ppm range in the same method. 8-High number of measurable elements - elements that are difficult to analyze in atomic absorption spectrometry such as Zr, Ta, rare earth, P and B can be easily analyzed.

Conclusion ICP AES is now highly rated as a multipurpose analysis technique. It is well regarded as an environmental measurement technique, along with atomic absorption spectrometry and its use is expected to expand even further in the future. Plasma sources are rich in characteristic emission lines, which makes them useful for both qualitative and quantitative elemental analysis. ICP- AES yield significantly better quantitative analytical data than other emission sources do. The excellence of these results stems from their high stability, low noise, low background, and freedom from interferences.

Weaknesses of ICP-AES : Differing viscosities can affect amount of sample uptake. Matrices can change nature of plasma Certain matrices can attack torch. Matrices can contain interfering spectral components. Instrumental Drift : Instrument reading can drift over a period of time due to physical changes in the optical system, or the configuration of the plasma. Standards need to be run at the beginning and end of each run in order to estimate and correct for this drift. Internal standards are used to compensate for differing matrices from sample to sample. Not effective for low levels of alkalis (less than 1-5 ppm). Only elemental data is provided - no direct structural information. Solids, can usually be dissolved using various techniques.