New experimental limit on the electric dipole moment of the neutron

Similar documents
CryoEDM: a cryogenic experiment to measure the neutron Electric Dipole Moment

The Search for the Neutron Electric Dipole Moment

Measuring the Neutron Electric Dipole Moment - A Tiny Number with Big Implications

Apparatus for measurement of the electric dipole moment of the neutron using a cohabiting atomic-mercury magnetometer

The cryogenic neutron EDM experiment at ILL

New measurements of neutron electric dipole moment

Improvements to the Mercury Electric Dipole Moment Experiment

Electric dipole moments: theory and experiment

arxiv: v1 [nucl-ex] 7 Oct 2011

CryoEDM The search for the electric dipole moment of the neutron

Creation of polarized ultracold neutrons and observation of Ramsey resonance for electric dipole moment measurement

TUNING NEUTRON RF-PULSE FREQUENCY

A next generation measurement of the electric dipole moment of the neutron at the FRM II

High-precision studies in fundamental physics with slow neutrons. Oliver Zimmer Institut Laue Langevin

Depolarization of ultracold neutrons during their storage in material bottles

NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENTS

Search for a Permanent Electric Dipole Moment of 199 Hg

Geometric-phase-induced false electric dipole moment signals for particles in traps

Nuclear spin maser with a novel masing mechanism and its application to the search for an atomic EDM in 129 Xe

The hunt for permanent electric dipole moments

Neutron and electron electric dipole moments (EDMs)

Neutron electric dipole moment

Congruences in ordered pairs of partitions

Parameters characterizing electromagnetic wave polarization

The New Search for a Neutron EDM at the SNS

A new UCN source at TRIUMF for EDM, β decay, gravity etc.

University of Huddersfield Repository

Spin Feedback System at COSY

Search for an electric dipole moment with polarized beams in storage rings

Storage ring proton EDM experiment and systematic error studies

Charged Particle Electric Dipole Moment Searches in Storage Rings

Xe nuclear spin maser and search for atomic EDM

University of Huddersfield Repository

SuperSUN new infrastructure for experiments with ultracold neutrons at ILL

An option of «UCN pump» for ESS. V.V. Nesvizhevsky. Institut Max von Laue Paul Langevin, 71 av. des Martyrs, Grenoble, France.

Present status and future prospects of nedm experiment of PNPI-ILL-PTI collaboration

Low-energy heating of ultracold neutrons during their storage in material bottles

Magnetic Field measurements with Csmagnetometers

Time Reversal and the electron electric dipole moment. Ben Sauer

EDM measurement in 129 Xe atom using dual active feedback nuclear spin maser

Nuclear spin maser and experimental search for 129 Xe atomic EDM

Electric dipole moment experiments

Institute Laue-Langevin, Grenoble

Victor Ezhov Petersburg Nuclear Physics Institute NRC KI ISINN 2015 May 25-29, Dubna

10.4 Continuous Wave NMR Instrumentation

The neutron Electric Dipole Moment

Electron EDM Searches

2EF Development of a SQUID-based 3 He Co-magnetometer Readout for a Neutron Electric Dipole Moment Experiment

Møller Polarimetry on Atomic Hydrogen

Project of ultracold neutron source with superfluid helium at WWR-M reactor (PNPI, Gatchina) and scientific research program А.P.

A new measurement of the electron edm. E.A. Hinds. Centre for Cold Matter Imperial College London

Experimental Atomic Physics Research in the Budker Group

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Polarized Molecules: A new Option for Internal Storage-Cell Targets?

PROGRESS TOWARDS CONSTRUCTION OF A FERMION ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

n-n" oscillations beyond the quasi-free limit or n-n" oscillations in the presence of magnetic field

Chapter 7. Nuclear Magnetic Resonance Spectroscopy

The nedm Project: A new cryogenic measurement of the electric dipole moment of the neutron

Improvements to the Mercury Electric Dipole Moment Experiment

The Search for the Electron Electric Dipole Moment at JILA

Atomic magnetometers: new twists to the old story. Michael Romalis Princeton University

* Neutron magnetic storage and neutron lifetime measuring

Fast Ion Confinement in the MST Reversed Field Pinch

New search for the Neutron Electric Dipole Moment using Ultracold Neutrons at the Spallation Neutron Source

Measurement of the electron EDM using Cold YbF Molecules:

Preparation of facilities for fundamental research with ultracold neutrons at PNPI

The KATRIN experiment

Shuichiro Kojima, Chikako Funayama, Shunya Tanaka, Yu Sakamoto, Yuichi Ohtomo, Chika Hirao, Masatoshi Chikamori, Eri Hikota

Ultrasensitive Atomic Magnetometers

Fundamental MRI Principles Module 2 N. Nuclear Magnetic Resonance. X-ray. MRI Hydrogen Protons. Page 1. Electrons

Search for a Permanent Electric Dipole Moment in Ra EDM Spin EDM Spin EDM. Spin. Pseudo-scalar. s d

Generating Photon Number States on Demand via Cavity Quantum Electrodynamics

Challenges in optics requirement and control of Storage Rings for Precision Measurement of EDM

Plasma Physics Prof. V. K. Tripathi Department of Physics Indian Institute of Technology, Delhi

EDM. Spin. ν e. β - Li + Supported by DOE, Office of Nuclear Physics

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

PROGRESS TOWARDS CONSTRUCTION OF A FERMIONIC ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

The 46g BGO bolometer

nedm: A Survey of Neutron Electric Dipole Moment Experiments

Compendium of concepts you should know to understand the Optical Pumping experiment. \ CFP Feb. 11, 2009, rev. Ap. 5, 2012, Jan. 1, 2013, Dec.28,2013.

Spin-tracking studies for EDM search in storage rings

Neutron lifetime experiment HOPE

A Brief Introduction to Medical Imaging. Outline

Precision neutron flux measurement with a neutron beam monitor

Neutron Electric Dipole Moment Experiment at PSI. Kazimierz Bodek for the nedm Collaboration

Tests on Superconductor Gravitational Effects

Neutrino Oscillations and the Matter Effect

Magnetic Measurements

Project P2 - The weak charge of the proton

A method to polarise antiprotons in storage rings and create polarised antineutrons

High Precision Spin Manipulation at COSY

Quasi-specular albedo of cold neutrons from powder of nanoparticles

EXAMINATION QUESTIONS (6)

New Search for Mirror Neutrons at HFIR

Fundamental MRI Principles Module Two

EDMs of stable atoms and molecules

Neutrino Helicity Measurement

Nuclear electric dipole moment in the Gaussian expansion method

arxiv:physics/ v1 3 Aug 2006

Measurement of Nucleon Strange Form Factors at High Q 2

Transcription:

New eperimental limit on the electric dipole moment of the neutron Article (Published Version) Harris, P G, Baker, C A, Green, K, Iaydjiev, P, Ivanov, S, May, D J R, Pendlebury, J M, Shiers, D, Smith, K F, van der Grinten, M and Geltenbort, P (1999) New eperimental limit on the electric dipole moment of the neutron. Physical Review Letters, 82 (5). pp. 904-907. ISSN 0031-9007 This version is available from Susse Research Online: http://sro.susse.ac.uk/22302/ This document is made available in accordance with publisher policies and may differ from the published version or from the version of record. If you wish to cite this item you are advised to consult the publisher s version. Please see the URL above for details on accessing the published version. Copyright and reuse: Susse Research Online is a digital repository of the research output of the University. Copyright and all moral rights to the version of the paper presented here belong to the individual author(s) and/or other copyright owners. To the etent reasonable and practicable, the material made available in SRO has been checked for eligibility before being made available. Copies of full tet items generally can be reproduced, displayed or performed and given to third parties in any format or medium for personal research or study, educational, or not-for-profit purposes without prior permission or charge, provided that the authors, title and full bibliographic details are credited, a hyperlink and/or URL is given for the original metadata page and the content is not changed in any way. http://sro.susse.ac.uk

New Eperimental Limit on the Electric Dipole Moment of the Neutron P. G. Harris,* C. A. Baker, K. Green, P. Iaydjiev, and S. Ivanov Rutherford Appleton Laboratory, Chilton, Didcot, Oon OX11 0QX, United Kingdom D. J. R. May, J. M. Pendlebury, D. Shiers, K. F. Smith, and M. van der Grinten University of Susse, Falmer, Brighton BN1 9QJ, United Kingdom P. Geltenbort Institut Laue-Langevin, BP 156, F-38042 Grenoble Cede 9, France (Received 17 September 1998) The latest neutron electric dipole moment (EDM) eperiment has been collecting data at the Institut Laue-Langevin (ILL), Grenoble, since 1996. It uses an atomic-mercury magnetometer to compensate for the magnetic field fluctuations that were the principal source of systematic errors in previous eperiments. The first results, in combination with the previous ILL measurement, yield a possible range of values of 27.0, d n, 5.0 3 10 226 e cm (90% C.L.). This may be interpreted as an upper limit on the absolute value of the neutron EDM of jd n j, 6.3 3 10 226 e cm (90% C.L.). [S0031-9007(99)08421-5] PACS numbers: 13.40.Em, 07.55.Ge, 11.30.Er, 14.20.Dh In order for particles to have electric dipole moments, the forces concerned in their structure must violate both space parity (P) and time reversal (T) symmetries [1]. P violation is a well-known feature of the weak interaction, but CP (and hence T) violation has thus far been found only in the neutral kaon system [2]. This leaves open a wide range of possibilities for competing theories that attempt to eplain its origin. Etensions to the standard model, such as additional Higgs fields, right-handed currents, or supersymmetric partners typically give rise to neutron electric dipole moment (EDM) contributions which are of order 10 225 to 10 227 e cm [3]; dipole moments of this size might also come from CP violation in QCD. Eperimental measurements of particle EDMs, and in particular that of the neutron, are providing some of the strongest additional constraints on these theories. The RAL Susse eperiment at ILL. This EDM eperiment uses the Ramsey resonance technique to measure with very high precision the precession frequency of ultracold neutrons in a weak magnetic field. The precession frequency will change in the presence of an electric field if the neutron has an EDM. Systematic errors in the most recent of these measurements, both those carried out at the Institut Laue Langevin (ILL) in Grenoble [4] and those at PNPI in Russia [5], were dominated by fluctuations in the magnetic field, for which it was impossible to compensate adequately with the eternal magnetometers in use at the time. Following an idea of Ramsey [6], the current EDM eperiment incorporates for the first time a comagnetometer based upon the storage of polarized atoms simultaneously with and in the same cell as the neutrons. However, instead of the 3 He atoms originally proposed by Ramsey, 199 Hg was used in this case; this was suggested by the University of Washington group, following its own measurement of its EDM [7]. The presence of the comagnetometer reduces by about a factor of 20 what was thought to be the dominant systematic error of the previous eperiment, by measuring the magnetic field in much more nearly the same volume as that occupied by the neutrons. It should be noted that, although the eperiment was substantially rebuilt to allow for the inclusion of the magnetometer, the environment (magnetic shielding, ambient temperature stability, high-voltage generation, etc.) remains similar. Here an outline of the eperimental technique is presented; full details will be published in an upcoming archival paper. EDM measurement principle. The measurement is made with neutrons stored in a cell permeated by uniform E and B fields. The terms 2m n? B and 2d n? E are added to the Hamiltonian determining the states of the neutron. Given parallel E and B fields, the Larmor frequency n "" with which the neutron spin polarization precesses about the field direction is hn "" 2m n? B 1 2d n? E. (1) For antiparallel fields, hn "# 2m n? B 2 2d n? E. Thus the goal is to measure, with the highest possible precision, any shift in the transition frequency n as an applied E field alternates between being parallel and then antiparallel to B. A schematic of the apparatus is shown in Fig. 1. The neutrons are prepared in a spin-polarized state by transmission through a thin, magnetized iron foil, and enter a 20-liter storage cell, composed of a hollow upright quartz cylinder closed at each end by aluminum electrodes that are coated with a thin layer of diamondlike hard carbon [8]. The storage volume is situated within four layers of mu metal, giving a shielding factor of about 10 000 to eternal magnetic field fluctuations. A highly uniform 1 mt vertical magnetic field is generated by a coil wound around 904 0031-9007 99 82(5) 904(4)$15.00 1999 The American Physical Society

Four-layer mu-metal shield Quartz insulating cylinder Main storage cell High voltage lead Coil for 10 mg magnetic field Upper electrode 24000 22000 20000 1/T Hg u.v. lamp Vacuum wall PMT to detect Hg u.v. light Neutron Counts 18000 16000 14000 RF coil to flip spins Magnet UCN polarising foil S N Mercury prepolarising cell Hg u.v. lamp UCN guide changeover Ultracold neutrons (UCN) 12000 10000 Resonant freq. 29.7 29.8 29.9 30.0 30.1 Applied Frequency (Hz) = working points FIG. 2. The Ramsey resonance curve for spin-up neutrons, N ". The corresponding pattern for N # is inverted but otherwise identical. UCN detector FIG. 1. Approimate scale: 1 m The neutron EDM eperimental apparatus. the vacuum tank with a uniform pitch in z, the vertical diameter of the cylinder. Approimately 20 s are needed to fill the storage cell with neutrons, after which the entrance door is closed pneumatically. The electric field is generated by applying high voltage to the upper electrode while keeping the lower electrode grounded. The transition frequency n of the neutrons is measured using the Ramsey separated oscillatory field magnetic resonance method. During the storage period, the neutrons interact coherently with two short ( 2 s) intervals of oscillating magnetic field having a chosen frequency close to the Larmor frequency. The two intervals are separated by a long period T 120 150 s of free precession. The last step is to count the number of neutrons N " and N # which finish in each of the two polarization states. This is achieved by opening the entrance door to the storage cell and allowing the neutrons to fall down onto the polarizing foil, which now acts as a spin analyzer. Only those in the initial spin state can pass through to the detector, which is a proportional counter in which neutrons are detected via the reaction n 1 3 He! 3 H 1 p. During one-half of the counting period, an rf field is applied in the region above the polarizing foil; this flips the spins of the neutrons, thereby also allowing those in the opposite spin state to be counted. Figure 2 shows N " from a succession of batch cycles, each with a slightly different offset between the precession frequency and the oscillating field frequency. The normal data-taking procedure entails choosing a working point at a half-height position close to the center of the resonance pattern in Fig. 2, where the slope of the curve is greatest. The batches are cycled continuously for 1 2 days, while about once per hour the direction of E is reversed. The data are fitted to a cosine curve to yield the resonant frequency. It can be shown that the uncertainty s dn on the dipole moment due to neutron counting statistics noise alone is then s dn h 2aET p N, (2) where N is the total number of neutrons counted and a is the visibility of the central resonance fringe: a N "ma 2 N "min N "ma 1 N "min, (3) with a similar value for N #. For the data involved in this analysis, approimate average values of the variables in Eq. (2) were a 0.5, E 4.5 kv cm, T 130 s, and N 13 000 neutrons per batch, with each batch cycle taking about 210 s. From one day of data, therefore (and allowing for pauses between runs and control measurements at zero voltage), s dn was about 6 3 10 225 e cm. The mercury magnetometer. Under normal running conditions, small changes in B (at the level of a few ng) cannot be avoided, and they invariably produce shifts in the neutron precession frequency that far eceed those from the d n? E interaction. A high-precision magnetometer is therefore essential. The current eperiment uses atoms of 199 Hg (with 3 3 10 10 atoms cm 3 ) stored simultaneously in the same cell as the neutrons. Gravity causes the center of mass of the (ultracold) neutrons to be about 0.5 cm lower than that of the (hot) Hg atoms; this may crudely be compared with the 30-cm separation of the magnetometers in the previous ILL eperiment [4] and the 10-cm separation between the pair of cells used in the measurement at PNPI [5]. The 199 Hg is polarized by optical pumping in a oneliter antechamber. Once the main storage cell has been filled with neutrons and the entrance door closed, the polarized mercury is allowed in to join the neutrons. The spins, first of the mercury and then of the neutrons, are rotated into the y plane (i.e., perpendicular to B) by 905

magnetic resonance. They both precess freely for 130 150 s. The magnetic field has a strength of 10 22 G, and the precession frequencies are therefore about 30 Hz and 8 Hz for neutrons and mercury, respectively. The mercury spin precession is monitored continuously with a circularly polarized beam of 254 nm resonance radiation which passes through the main storage cell in the direction. This light suffers an absorption proportional to the component of the Hg spin vector. It is detected in a photomultiplier tube; the ac component of the tube output, which has the form of an eponentially decaying sinusoidal oscillation corresponding to the precession and slow depolarization of the mercury atoms, is digitized at 100 Hz by a 16-bit analog-to-digital converter. With a typical 199 Hg spin relaation time of 70 s, a storage time of 130 s, and an initial signal-to-noise ratio of 1000, the magnetic field can be measured by one batch with an rms error of about 2 ng. For comparison, the neutron counting statistics rms error per batch currently corresponds to an uncertainty in B of nearly 10 ng. It should be noted that the EDM of 199 Hg itself has been shown to be less than 8.7 3 10 228 e cm [7], which is far smaller than the neutron EDM sensitivity of this eperiment. The successful performance of the mercury magnetometer [9] has essentially eliminated magnetic field drift as a source of systematic uncertainty. This is demonstrated in Fig. 3, in which the measured neutron precession frequency is plotted as a function of time over a period of one day; data are shown both before and after correction by the mercury frequency measurements. In searching for frequency shifts corresponding to the hourly polarity reversals in the raw signal, it is difficult to eliminate the drift noise entirely; however, the corrected signal (or, equivalently, the ratio of neutron to mercury atom precession frequencies) may simply be plotted as a function of the applied electric field, and a linear fit yields a slope which is directly proportional to the electric dipole moment. Results. There have been ten reactor cycles of 50 days length since data taking with the mercury magnetometer in place began in 1996, during which time Neutron Frequency (Hz) 29.9845 29.9840 29.9835 29.9830 29.9825 29.9820 29.9815 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Time (hours) Raw neutron frequency Corrected frequency FIG. 3. Neutron resonant frequency measurements, showing both the raw and the mercury-corrected measurements. 906 5 10-11 T 322 measurement runs have been completed. Analysis of the data obtained yields a value for the EDM of d n 1.9 6 5.4 3 10 226 e cm, (4) with a 2 n of 0.97 for 321 degrees of freedom, corresponding to a confidence level of 62%. Grouping the runs by reactor cycle, as shown in Fig. 4, the 2 n is 0.37 for 9 degrees of freedom (giving a confidence level of 95%). Systematic effects are judged to be negligible in comparison with the uncertainty due to counting statistics. This result by itself yields an upper limit on the neutron EDM of jd n j, 9.4 3 10 226 e cm 90% C.L.. The data obtained prior to the installation of the internal mercury cohabiting magnetometer yielded d n 23.4 6 2.6 3 10 226 e cm [4], with 2 n 2.2 for 14 degrees of freedom. The large 2 reflected the overall scatter in the data from random shifts in the magnetic field that were not fully compensated by the rubidium magnetometers. This time-varying systematic effect had a spread which may be accommodated by multiplying the uncertainty obtained from neutron counting statistics by p 2 n, giving an overall statistical uncertainty of 3.9 3 10 226 e cm. In addition, it may have caused an overall offset due to incomplete cancellation in the long-term average. As a conservative estimate, this should certainly be less than 3.1 3 10 226 e cm, which would have been the false EDM signal obtained (with an uncertainty of 2.5 3 10 226 e cm) if the average frequency shift observed in the three magnetometers had been applied to the neutrons instead. Thus, the final result was d n 23.4 6 3.9 stat 6 3.1 syst 3 10 226 e cm, (5) thereby giving a net uncertainty of 4.9 3 10 226 e cm. This was published as 23 6 5 3 10 226 e cm [4]. The new data support the previous analysis: it now seems clear that the observed scatter was due to magnetic field fluctuations rather than to other, unknown, systematic effects. Neutron EDM (10-26 e cm) 60 50 40 30 20 10 0-10 -20-30 -40-50 -60-70 -80 106 108 110 112 114 116 Reactor cycle number FIG. 4. Results of the neutron EDM measurements, grouped by reactor cycle.

Combining the results of the two sets of data, an overall value of d n 21.0 6 3.6 3 10 226 e cm (6) is obtained, corresponding to a 90% confidence interval of 27.0, d n, 5.0 3 10 226 e cm. (7) Placing limits that are symmetric about zero, the upper limit on the absolute value of jd n j is therefore found to be jd n j, 6.3 3 10 226 e cm 90% C.L.. (8) Although concerns frequently arise about the combining of different data sets in this manner, the authors are of the opinion that in this case the systematic errors of the earlier data set are sufficiently well understood to warrant its inclusion. Systematic errors. Although the result obtained is consistent with a neutron EDM of zero, it is important to evaluate possible systematic effects that might nonetheless contribute to the generation of an artificial signal or mask a real EDM. Such effects, discussed briefly here, will be covered in some detail in the upcoming archival paper. Leakage currents and sparks. Any azimuthal component of leakage current around the storage cell will result in a small additional magnetic field either parallel or antiparallel to B, which will reverse polarity with the electric field and thus give rise to a spurious EDM signal. However, as our leakage currents are typically 1 na, even the etreme case of a complete circulation around the bottle would result in an apparent EDM of less than 1 3 10 226 e cm. In confirmation of this, we have studied the measured EDM as a function of leakage current and have found no measurable effect. Any electrical activity that occurs during a measurement cycle will normally disturb the mercury to such an etent that a reliable frequency estimate is impossible to obtain, and the cycle is therefore automatically rejected. A number of other possible processes, e.g., spark-induced changes in the residual magnetization of the mu-metal shields or shifts in the storage cell position in response to high-voltage induced forces, might produce systematic shifts in the magnetic field; however, the mercury magnetometer provides more than adequate compensation for any such effects. The v 3 E effect. If the neutrons have a net rotational motion, any radial component of the electric field will be seen in their rest frame as a combination of electric and magnetic fields. However, any such flow of neutrons is epected to be destroyed by wall collisions before the first Ramsey pulse is applied. We calculate that the maimum error to be epected from this source and from higher-order v 3 E effects is below 1 3 10 226 e cm. Other high-voltage induced effects. The high-voltage stack is a source of ac as well as dc currents which might affect the precession frequencies of mercury and neutrons. For a real EDM, the frequency shift between positive and negative polarities changes sign as the magnetic field reverses; the frequency shift from an ac magnetic field does not. Roughly half of the data were taken for each direction of the magnetic field, and the difference between the measured EDMs for the two subsets is 0.3 6 5.4 3 10 226 e cm, which gives no evidence for the presence of such a systematic effect. In conclusion, the inclusion within the eperimental apparatus of a cohabiting magnetometer has enabled the neutron EDM to be measured with a statistical accuracy comparable to previous measurements, and with systematic uncertainties reduced to a negligible level. The similar nature of the neutron frequency fluctuations in the two sets of data discussed above supports the hypothesis that the fluctuating systematic errors limiting the previous measurement at the ILL were due to slowly varying systematic shifts in the magnetic field. It therefore seems reasonable to assume that there were no larger unknown systematic errors conspiring, by chance, to mask a true EDM signal in the earlier data set. Under this assumption, the two sets of data combine to yield an overall limit on the absolute value of the neutron EDM of jd n j, 6.3 3 10 226 e cm. The authors are most grateful to N. F. Ramsey for many useful discussions and ideas, and to Y. Chibane, M. Chouder, and A. I. Kilvington for their invaluable assistance in the early development of the mercury magnetometer; and likewise to the group of E. N. Fortson at the University of Washington, who made available information about the techniques that they had devised for magnetometry using atomic mercury. The eperiments would of course not have been possible at all without the cooperation of, and generous provision of neutron facilities by, the ILL itself. This work has been funded by a grant from the U.K. Particle Physics and Astronomy Research Council (PPARC). *Currently on leave of absence from the University of Susse, Falmer, Brighton BN1 9QJ, United Kingdom. Currently on leave of absence from Institute of Nuclear Research and Nuclear Energy, Sofia, Bulgaria. Currently on leave of absence from St. Petersburg Nuclear Physics Institute, St. Petersburg, Russia. [1] S. M. Barr, Int. J. Mod. Phys. A 8, 209 (1993). [2] J. H. Christenson, J. W. Cronin, V. L. Fitch, and R. Turlay, Phys. Rev. Lett. 13, 138 (1964). [3] J. Ellis, Nucl. Instrum. Methods Phys. Res., Sect. A 284, 33 (1989). [4] K. F. Smith et al., Phys. Lett. B 234, 191 (1990). [5] I. S. Altarev et al., Phys. At. Nucl. 59, 1152 (1996). [6] N. F. Ramsey, Acta Phys. Hung. 55, 117 (1984). [7] J. P. Jacobs et al., Phys. Rev. A 52, 3521 (1995); see also J. P. Jacobs et al., Phys. Rev. Lett. 71, 3782 (1993); S. K. Lamoreau et al., Phys. Rev. Lett. 59, 2275 (1987). [8] M. G. D. van der Grinten et al., Nucl. Instrum. Methods Phys. Res., Sect. A (to be published). [9] K. Green et al., Nucl. Instrum. Methods Phys. Res., Sect. A 404, 381 (1998). 907