Study of the evolution of the mechanical properties of orthodontic arches by stimulated infrared thermography

Similar documents
ACTIVE THERMOGRAPHY FOR MATERIALS NON-DESTRUCTIVE TESTING

Thermal behavior study of the mold surface in HPDC process by infrared thermography and comparison with simulation

Multiscale analysis of thermography imaging dynamic for sol-gel coating discrimination

Active Infrared Thermography applied to detection and characterization of non emergent defects on asphalt pavement

Infrared thermography as a tool to elaborate procedures for predictive maintenance of ball mills equipment

Which picture shows the larger flux of blue circles?

EXPERIMENT NO. 4. Thermal Radiation: the Stefan-Boltzmann Law

Thermal Systems. What and How? Physical Mechanisms and Rate Equations Conservation of Energy Requirement Control Volume Surface Energy Balance

Effect of object-to-camera distance on temperature and spatial resolution of a Thermal imaging system FLIR SC 5000

Fig. 1. Schema of a chip and a LED

Detection of rolling bearing degradation using infrared thermography

Combined Acoustic Emission and Thermographic Testing of Fibre Composites

2D Simulations and Electro-Thermal Analysis of Micro-Heater Designs Using COMSOL TM for Gas Sensor Applications

PHYS2627/PHYS2265 Introductory quantum physics LABORATORYMANUAL Experiment 1: Experiments of Thermal Radiation

In-Line Inspection of Hot-Rolled Steel Billets by Heat Flux Thermography

CIGRE SC A2 & D1 JOINT COLLOQUIUM 2011, KYOTO JAPAN. Assessment of Overload Capabilities of Power Transformers by Thermal Modelling.

Inverse Heat Flux Evaluation using Conjugate Gradient Methods from Infrared Imaging

Use of Matlab package for external local calibration of IR camera with microbolometric FPA detector

INTRODUCTION Radiation differs from conduction and convection in that it does not require the presence of a material medium to take place.

POE Concepts and Learning Objectives

Page 2 of 14 Report Ref. No

Temporal analysis for implicit compensation of local variations of emission coefficient applied for laser induced crack checking

Processing Induced Change of Thermal Transport Properties of NiTi-Shape Memory Alloy

Detection of Subsurface Defects using Active Infrared Thermography

Carbonized Electrospun Nanofiber Sheets for Thermophones

In situ quantitative diagnosis of insulated building walls using passive infrared thermography

Use of Infrared Thermography for Building Inspection

Thermal Resistance Measurement

Thermal Radiation: The Stefan-Boltzmann Law

Temperature Measurement

Atmospheric "greenhouse effect" - How the presence of an atmosphere makes Earth's surface warmer

Surface crack detection using infrared thermography and ultraviolet excitation

Lock-in Thermography on Electronic Devices Using Spatial Deconvolution

Principles Of Engineering Detailed Outline

Transmission Stability and Infrared Windows: The Effects of Transmissivity on Data Accuracy

Good practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors

Non-Destructive Inspection of Brazed Joint by Pulsed Phase Thermography

Supporting Information: Semiconductor-based Multilayer Selective Absorber for Unconcentrated Solar Thermal Energy Conversion

Thermal modelling for on-interposer thermoelectric sensors

QIRT th International Conference on Quantitative InfraRed Thermography

RESISTOR, FIXED, SURFACE MOUNT, THIN FILM, NON-HERMETICALLY SEALED BASED ON TYPE TNPS. ESCC Detail Specification No. 4001/029

Test Method of Specified Requirements of FTTS-FA-010. Far Infrared Textiles

Detection of rolling bearing degradation using infrared thermography

STUDY OF OPTICAL-ENERGY PARAMETERS OF PLANETARY EMISSION DETECTORS IN SOLAR MODULES WITH PARABOLOCYLINDRICAL HUB V. Mayorov, V. Trushevsky, Ph.D. L.

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

Experimental Modal Analysis of a Flat Plate Subjected To Vibration

Analysis algorithm for surface crack detection by thermography with UV light excitation

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Introductory Physical Science & Force, Motion, and Energy Correlation with the New Hampshire Grade 10 Science Curriculum Frameworks

Reflow Soldering Processes Development Using Infrared Thermography

Defining quality standards for the analysis of solid samples

Multi-scale approach of the mechanical behavior of RC structures Application to nuclear plant containment buildings

Examination of metallic surfaces for IR gray body sources

PHOTOLUMINESCENCE SPECTRA AND QUANTUM YIELDS OF GOLD NANOSPHERE MONOMERS AND DIMERS IN AQUEOUS SUSPENSION

MIL-STD-883E METHOD THERMAL CHARACTERISTICS

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

Atmospheric "greenhouse effect" - How the presence of an atmosphere makes Earth's surface warmer

University of Connecticut Department of Electrical and Computer Engineering. ECE 4901: Fall 2017 Spring 2018

Comparison between time- and frequency-domain induced polarisation parameters

Technical Note 103. Response Enhancement for the Loral CCDs. using Ultra-Violet Flooding. A. P. Oates (RGO)

Calibrating the Thermal Camera

Last Revision: August,

Analysis of the thermal heating of poly-si and a-si photovoltaic cell by means of Fem

A dynamic model of electric resistor's warming and its verification by micro-thermocouples

Memory Thermal Management 101

Automated Stability Testing Delivering Rapid Product Development

On the FPA infrared camera transfer function calculation

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 14.

Calculation of the heat power consumption in the heat exchanger using artificial neural network

Thermocouple Dynamic Errors Correction for Instantaneous Temperature Measurements in Induction Heating. Krzysztof Konopka 1

Numerical Modeling of the Thermal Behavior of Corrosion on Reinforced Concrete

Electrolytic Tiltmeter Temperature Coefficients: Source, Definition and Use to Improve Accuracy

Thermo-Mechanical Response of Functionally Graded Materials for Extreme Environments

EGU Land surface temperature measurement with an infrared camera, in-situ Emissivity measurement

An Acoustic Emission Approach to Assess Remaining Useful Life of Aging Structures under Fatigue Loading PI: Mohammad Modarres

Standard Practice for Heat Aging of Plastics Without Load 1

THERMO-ELASTO-PLASTIC MODEL FOR SHOT PEENING : A NUMERICAL AND EXPERIMENTAL APPROACH

INC 331 Industrial Process Measurement. Instrument Characteristics

PROCESS CONTROL BASIS FOR A COST-EFFECTIVE SELECTIVE SOLDERING PROCESS

Pulsed IR Thermography for Package Applications

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Investigation of Jet Impingement on Flat Plate Using Triangular and Trapezoid Vortex Generators

INFRARED THERMOGRAPHIC NONDESTRUCTIVE TESTING OF COMPOSITE MATERIALS: DETERMINING THERMAL PROPERTIES, DETECTING AND CHARACTERIZING HIDDEN DEFECTS

Defect detection with thermal imaging and phase shifting methods in lock-in thermography

CHEM 681 Seminar Mingqi Zhao April 20, 1998 Room 2104, 4:00 p.m. High Resolution Transmission Electron Microscopy: theories and applications

Physics Curriculum Guide for High School SDP Science Teachers

Importance of the Running-In Phase on the Life of Repairable Systems

Transient Thermal Measurement and Behavior of Integrated Circuits

Chapter 3. Experimentation and Data Acquisition

LASER SPOT THERMOGRAPHY FOR CRACK DETECTION IN ALUMINUM STRUCTURES

Trench IGBT failure mechanisms evolution with temperature and gate resistance under various short-circuit conditions

Liquid water is one of the

8.5 GREENHOUSE EFFECT 8.6 GLOBAL WARMING HW/Study Packet

Heriot-Watt University

Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

Ultrasonic and optical stimulation in IR thermographic NDT of impact damage in carbon composites

Experimental study of mechanical and thermal damage in crystalline hard rock

Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

Thermal Interface Materials (TIMs) for IC Cooling. Percy Chinoy

Study of Reliability Test Methods for Die-attach Joints on Power Semiconductors

Transcription:

14 th Quantitative InfraRed Thermography Conference Study of the evolution of the mechanical properties of orthodontic arches by stimulated infrared thermography by N. Chahine*, K.Mouhoubi**, A. Diakhate**, S. Harakeh****, P. Millet*, JL. Bodnar ** * Univ. Reims Champagne Ardenne, LISM EA4695, UFR Odontologie - 51100 Reims - CHU Reims, Pôle de Médecine Bucco-Dentaire, F-51100 Reims, France. ** GRESPI / CATHERM, UFR Sciences Exactes et Naturelles, BP 1039, 51687 Reims cedex 02, France *** U.F.R. ODONTOLOGIE, 2,rue du Général Koenig, 51100 REIMS, France **** Steve Harakeh, Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Kingdom of Saudi Arabia Abstract Electron microscopic observation of the surface of orthodontic arches reveals observable differences between new and used arches after four weeks in the mouth. This qualitative observation led us to consider their study by stimulated infrared thermography. These dental arches consist of a nickel-titanium (NiTi) shape memory alloy and are highly stressed during the stay in the mouth. Over the months, there will be evolution of their mechanical properties with multifactorial causes. In this study, we will demonstrate that it is possible to differentiate between the used arcs from the new arcs by observing their thermal response during a controlled heating. 1. Introduction This study focuses on the analysis of alterations affecting orthodontic arches. These orthodontic arches are used in dentistry to correct the positioning of the teeth. These devices must have remarkable strength and elastic properties. They are generally made of a nickel and titanium alloy called NiTi. This shape memory alloy allows to exert a constant pressure on the tooth and thus corrects its position during treatment. The duration of this orthodontic treatment is of the order of 12 to 15 months, it is more expensive because of the frequent replacement of the arches. The oral medium exposes the arc to many stresses and constraints, including both mechanical and chemical (acidity, tartar...). Such conditions will alter its properties and require its regular replacement. In general, the bow remains in the mouth for 4 weeks before being replaced. The renewal of the arches makes the treatment expensive due to the number of interventions needed. Based on this, it would be interesting to identify the causes of such alterations occurring in these devices and deal with them. In this work, we will identify the defects using a control method called infrared thermography. The advantages of this method are numerous: one of the interests lies in its ease of implementation and in its limited cost. Moreover, this method is non-destructive and allows the repetition of the same tests. Finally, it allows the analysis of defects on the surface when the analysis is carried out in both a static mode and more in depth if this analysis is carried out in a dynamic mode. This is why the analysis of the results will be conducted in two stages: a first stage include analysis of static (without heat input) and a second stage in dynamic mode (with heat input). The chosen approach will allow the comparison between the thermal responses of new and used samples when subjected to a thermal excitation or not. This protocol will make it possible to identify the altered characteristics in the samples and will make it possible to demonstrate the correlation between the presence of defects and the specific characteristics of these samples.the final goal is to find solutions for those alterations. 2. Device and experimental protocol 2.1. Device 2.1.1. Static analysis The sample was attached at both ends using two connectors (see Figure 1). The observation is carried out using a Flir thermal imaging camera (model SC655) clocked at 6.25 Hz when the sample is in thermal equilibrium with the ambient environment. License: https://creativecommons.org/licenses/by/4.0/deed.en 1

2.1.2. Dynamic analysis Fig. 1. Arc fixed on the device Fig. 2. Stabilized power supply Fig. 3. Thermal image of an electric current arc Fig. 4. Temperature response of an arc in dynamic regime The arc is maintained with the same connectors but is traversed by an electric current delivered by a stabilized power supply (see Figures 1 and 2). The dental arch serves as an electrical resistance, the observation of its heating by joule effect with a thermal camera allows studying it in dynamic regime. The thermally stressed section (located between the 2 terminals) has a length of 50 mm for all the samples studied. A voltage of 1.7 V at 2.4 A (ie a power of 4 W) was applied to the portion of the arc for a period of 15 seconds. The total observation time is 35 seconds, 15 seconds of heating and 20 seconds for cooling of the sample. The thermal transition makes it possible to highlight the defects present in the material. The observation is carried out as before using a thermal camera (FLIR, equipped with a 2.8-fold macro lens), driven by thermal imaging software (ThermaCAM Researcher Pro 2.01), clocked at an acquisition frequency of 6.25 Hz. 2.2. Experimental protocol The objective was to identify and quantify the extent of alterations of orthodontic arches. These alterations may be surface defects due to oxidation or deposition zones (tartar, etc.) or internal defects such as micro-cracks or microlaminations. The causes of these defects will be discussed based on the appearance or the development of these defects. Our interest is to use infrared thermography to detect there defects and characterize them. The analysis will be done by the extraction of the thermograms before heating (static) them or at the end of the warm-up phase (dynamic), where the temperature is the highest. The static analysis should allow us to highlight the superficial defects characterized by emissivity variations because the samples are in thermal equilibrium with the medium and the measured signal can depend only on the emissivity parameter and the environmental conditions. While results obtained from the dynamic phase will allow us to highlight the presence of internal defects as a result of subjecting the sample to an internal heat flow related to local thermal and electrical conductivity variations induced by the presence of these defects in the sample. The thermograms obtained using a thermal camera will allow us to carry out qualitative and quantitative analyzes. The qualitative analysis will yield a first sorting between samples but a quantitative approach is necessary to classify the samples in a rigorous and objective manner. The count of faults identified on each arc and the measurement of various parameters concerning them will be done using the open source software ImageJ and more particularly thanks to its counting module "Analysis particles" (see description in the table below) : after performing a thresholding operation on the 2

thermal image, it would be possible to obtain a large number of very interesting information on the defects observed and their characteristics such as their numbers, their areas or their perimeters. This information will be useful in positioning the arcs relative to each other according to different criteria that will make them possible to cross. Table 1. Defect counting with ImageJ Fig. 5. Raw image Fig. 6. 8-bit switching Fig. 7. thresholding Fig. 8. Counting 3. Presentation of the samples studied New Used Fig. 9. New and used arches 3

18 orthodontic arches were analyzed. These arches were made from nickel titanium shape memory alloy which gives them super elastic properties. There were new samples measuring 17 cm in length or used ones with varying lengths according to the cut made by the practitioner according to the dentition of the patient (7 to 17 cm). The orthodontic arches analyzed came from different manufacturers (AZDENT, AMERICAN ORTHO, ORTHOCLASSIC), their sections varied according to two modalities: round sections of 0.16 mm of diameter or rectangular sections of dimensions 0.16 x 0.22mm. 4. Results obtained 4.1. Qualitative approach In this analysis we limit ourselves to a direct description of the thermograms. The goal was to observe the presence or absence of defects. 4.1.1. Static analysis The 18 new and used samples were studied at room temperature (thermal equilibrium). It is shown below a comparison between new / used Orthoclassic brand arches. Table 2. Static arc comparison Reflect Reflect Defects Fig. 10. New arches Fig. 11. Used arches Direct observation makes it difficult to detect defects on the arcs for two reasons: the weakness of the thermal contrast and the presence of reflections, which makes identification difficult when defects exist. Thus in Figure 11 (used), it is noticed that at least 2 thermally active areas of comparable intensities. However, a more careful observation shows us that we are dealing in one case with a reflection identified by a soft outline, and in other cases with surface defects identified by sharp and irregular contours. Static analysis on the series of samples studied was made difficult and inconclusive. The cause of this phenomenon can be explained in a simple way using the equation of thermography : 4 4 4 L(λ, ) = τ atm,λ,. ε λ,. σ. T ech + ρ ech,λ,. ε amb,λ,. σ. T amb + (1 τ atm,λ, ). σ. T air (1) With respectively τ_ (λ, ), ε_ (λ, ), ρ_ (λ, ) the transmissivity, emissivity and directional spectral reflectiveness of the different media (atmosphere, samples, ambient). T medium temperatures and σ Stefan-Boltzmann's constant. It is known that the signal measured by the camera can have several causes : The sample's own emission (thermal effect) Sample contribution 4 τ atm εσt ech Multiple reflections of the ambient environment on the sample (Radiative effect) Atmospheric emission Contribution of the environment 4 ρ ech ε amb σt amb 4 (1 τ atm )σt air However, in the static regime, the orders of magnitude between the actual emission of the sample and the environmental contributions are comparable, which has the effect of exaggerating the relative importance of the radiative 4

and atmospheric effects. On the other hand, in a dynamic regime (joule heating here) the own emission of the sample is preponderant compared to the other contributions because it follows a rapid evolution in T4 which has the effect of reducing their parasitic contribution in the 'analysis. 4.1.2. Dynamic analysis In the table below, it would be observed that the thermal images of a new and used sample coming from the same manufacturer subjected to a thermal disturbance (joule effect). It may be concluded that the new samples have a thermally homogeneous surface in contrast to the used sample. Table 3. Comparaison arcs American ortho en dynamique Defects Fig. 12. New arch Fig.13. Used arch The following table shows two new and used samples from another manufacturer (Azdent) which subjected to the same thermal disturbance and was observed in the presence of temperature inhomogeneity on the two arcs. It would be noted that the used sample has more thermally active zones. Table 4. Comparaison arcs Azdent en dynamique Defects Defects Fig. 14. New arch Fig. 15. Used arch These observations on a number of samples indicate that as a rule the new samples may have defects but in a limited number in comparison to the used samples having more defects. Note also that the dynamic regime can identify a larger number of defects. 5

Number of defects 14 th Quantitative InfraRed Thermography Conference, 25 29 June 2018, Berlin, Germany 4.2. Quantitative approach In this analysis, we are interested in the number of defects and their characterization. We will study the thermograms obtained in a dynamic mode. 4.2.1. Dynamic regime analysis The fault count was performed as previously indicated using the ImageJ software. As can be seen in the following table the number of defects has been accounted for, as well as the area of defects that has been estimated. Status New Used Number of Number of Type defects Total area defects Total area 1 3 84 15 86 2 0 0 24 166 3 4 4 10 18 4 9 13 6 16 5 5 6 19 167 6 5 5 12 41 7 5 14 12 411 8 5 98 23 225 9 2 80 18 385 10 3 3 13 38 11 6 357 9 226 12 2 167 17 226 13 5 45 26 194 14 0 0 15 104 15 3 19 10 205 16 2 77 27 188 17 4 179 24 254 18 8 30 15 153 Table 5. Defect characterization First, we wanted to verify the previous observation that used samples had a higher number of defects. The histogram below clearly confirms this observation. For each variant of the same type of sample (same manufacturer, same diameter) the ratio number of used defect / number of new defect can be greater than 4 in certain cases (see for example type 8 and 14). Fig. 16. Comparison of the number of new/used faults Then studied the distribution of the samples according to a multicriterial approach, we crossed the two measured parameters (number of defects and area of the defects) and observed the distribution of the points of measurement. Once 6

Area of defects 14 th Quantitative InfraRed Thermography Conference, 25 29 June 2018, Berlin, Germany again we noticed a clear distribution when these two criteria are crossed: we have two distinct distributions of the measurement points (see graph below) : 450 400 350 300 250 200 150 100 New Used New average Used average 50 0 0 5 10 15 20 25 30 Number of defect Fig. 17. Multi-criteria analysis For the new samples, we observed a grouping in the lower left part of the graph. However, this was not the case in the used samples which were grouped in the right part in a slightly higher position, which means that the new samples have on average a number of defects lower than those present in the used samples. Moreover, the areas of these defects, as present in the new samples, are on average slightly less than those found of the used arcs. In summary, we have more defects, more in the used which is consistent with the intuition that we can have and the observations made in static mode. The table below shows that the differentiation criterion between the two types of arcs is the number of defects more than their size. As seen in the following table when comparing the difference between the barycenter of the two series and the standard deviations of the total population of the samples, it was found that this ratio is greater along the axis corresponding to the parameter "number of defects". Used samples Table 6. Recap Statistics on all samples Barycentric deviation New samples Average number of defects 3,9 16,4 10,2 12,4 162 Standard deviation number of defects 2,4 6,3 7,7 Average defect area (px²) 65,6 172,4 119 106,8 94 Defect area standard deviation (px²) 91,6 112,5 113 Ratio of barycentric deviation to standard deviation of total population (%) 7

5. Conclusion This study made it possible to differentiate between two sets of samples of orthodontic arches, new and used, and to quantify their state of deterioration by studying their thermal responses in static and dynamic regimes (with joule heating). Static analysis did not significantly and reliably differentiate the two sample series due to the preponderance of detection artifacts related to ambient conditions such as reflection. The presence of many reflections did not allow to effectively differentiate the two batches of samples. To correct this, it was necessary to warm the samples to reduce the influence of these effects. For this, the samples were subjected to an electric current of a power of 4 W for 15 s. Thermal disruption allowed the Joule samples to heat up and thus increase the thermal contrast of the defects while reducing the influence of the reflections. The dynamic analysis showed that the new samples had fewer defects than the used ones as may be expected. An additional quantitative analysis using the ImageJ software made it possible to count these defects and measure their surface area. The crossing of these parameters showed that the two series of samples could be correctly differentiated by these two quantities: the used samples have a significantly greater number of defects, and their average size seems slightly larger than that of the new samples. In conclusion, we can say that stimulated infrared thermography is an effective method of analysis that allowed us to highlight the presence of alteration in the orthodontic arches. This work is not complete yet and work is in progress to identify the origin of these alterations. 8