ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Similar documents
costech instruments ECS 4010 Elemental Combustion System CHNS-O

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

The art of elemental analysis

Elemental Analysis: CHNS/O characterization of polymers and plastics

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

OXITEST Oxidation Test Reactor

Elemental Analysis: NCS characterization of paper

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

Agilent G2350A Atomic Emission Detector (AED)

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Rapid Catalyst Screening Reactors

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Introducing 7820A GC System. Reliability, Simplicity & Affordability!

Varian Galaxie Chromatography Data System for Preparative HPLC

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

GAS CHROMATOGRAPHY (GC)

Fusion UV/Persulfate TOC Analyzer

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

PRINCIPLE. III. EQUIPMENT a. FlashEA 1112 b. Micro balance c. Computer IV. MATERIALS a. Two forceps (curved tip)

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Carbon (Organic, and Inorganic)

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

Advanced technics in the. (TIC/TOC/TNb)

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Protein Sequencer PPSQ-31A / 33A C297-E055B

Petrochemical. Transformer Oil Gas Analysis - TOGA

Fusion UV/Persulfate TOC Analyzer

Hydra-C Application Note: 1076

TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:

883 Basic IC plus. The smallest Metrohm ion chromatograph

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

ionos The most advanced stable isotope software ever created

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Kjeltec 2300 Analyzer Unit

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Analyze... Cheese. Ice Cream. Sour Cream. Yogurt. Butter. Margarine. Deboned Poultry. Beef. Condiments. Cookies. Crackers. Snack Foods. and more...

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

AutoChem II 2920 A Catalyst Characterization Laboratory

Thermo Scientific GasBench II

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

High-Pressure Volumetric Analyzer

DYNAMIC SORPTION. Dynamic Sorption Breakthrough Analyzer. Gas Purification

NEW. A class of its own. Centrifuge 5430 / 5430 R

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

BioDrop DUO dsdna Application Note

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

ISSP User Guide CY3207ISSP. Revision C

The Plus for your lab!

DMA-80L TECHNICAL SPECIFICATIONS

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Last updated: Copyright

Mira Metrohm Instant Raman Analyzer. Always ready to measure

41. Sim Reactions Example

Scientific Instruments for Radiocarbon Dating and Accelerator Mass Spectrometry

473 Dew Point Hygrometer

novaa 800 D Atomic Absorption Spectrometer

110 Lowell Rd Hudson, NH USA Tel:

Agilent MassHunter Quantitative Data Analysis

473-SHX Dew Point Mirror

Compact Orifice FlowMeter

Lab Activity H4 It s Snow Big Deal

La RMN quantitative appliquée aux petites molécules

DYNAMIC SORPTION. Dynamic Sorption Breakthrough Analyzer. Gas Purification. Ceramics. Energy. Carbons. Pharma

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

The Clinical Chemistry System that offers more so you do less!

Automatic titrators, TitroMatic

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

473 Dew Point Hygrometer

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

DI 3500 Discrete Aoalvzer

ConFlo III An Interface for High Precision d 13 C and d 15 N Analysis with an Extended Dynamic Range

Product Descriptions and Offerings

ADI 2040 Process Analyzer

Skin Damage Visualizer TiVi60 User Manual

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Edgetech Instruments Inc.

Transcription:

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

ECS 8020 CHNS-O Analyzer Organic Elemental Analysis ECS 8020 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method. ECS 8020 is a state-of-the-art system for the elemental analysis based on sample combustion and separation of gases with a chromatographic column. The combustion products, i.e. CO2, H2O, N2 and SO2, are separated and quantified by a high resolution TCD detector. ECS 8020 is fully automatic, from the available samplers to the oxygen dosage, from the monitoring of consumables status to the automatic leak test.

ECS 8020 is composed by: Dual furnace combustion system (for a better combustion and optimization of catalysts) Safety quick fit system for reactors connection (easy and safe way to set the instrument) Customized GC column Detection system Data acquisition and handling Several configurations may be set for the determination of the target element. Typical configurations are for: CHNS; CHN; CN; CNS; O Choose the best configuration by choosing the right chemicals, consumables and prepacked reactors. The versatility of ECS 8020 can be expressed as: Sample weight Sample type Liquid or solid sample

Three different samplers are available: Pneumatic autosampler up to 147 positions Electronic autosampler with 32, 50, 100 positions Manual sampler Automatisms make it particularly user-friendly: Automatic oxygen dosage system (for a better consumption of oxygen and consumables) Automatic consumables status monitoring Automatic leak test Standby mode (gas, energy and time savings) Automatic oxygen dosage: main highlights. Details of sample are registered: Position Type Weight ECS 8020 will dose the oxygen for the right combustion. No oxygen or consumables wastes.

EAS Clarity Powerful softwarefor powerful instrument Getting data, analyzing data, presenting data Integration There is extensive possibility to modify chromatograms. The chromatogram can be changed by entering global parameters or interactively, through direct graphic modification of the baseline. Overlay Simultaneously displays a virtually unlimited number of c h r o m a t o g r a m s a n d t h e i r mathematical modification. Calibration Internal and external standard calculation methods. Automated measuring support Sequence tables for any set of samples.

What the user can do Summary result tables Displays and prints selected results from all simultaneously displayed chromatograms. User settings User selects parameters for peak display and the specification for axes, including color from an extensive array of color settings. Text labels and lines, either as part of the area or anchored to a chromatogram, may also be inserted. Export Optional exportation of all results, with or without the chromatogram, in various formats, into a file or clipboard. Import Imports chromatograms or mathematical curves, which have been saved in text or AIA formats, from other programs. Special features LIMS Clarity offers connectivity with LIMS both for sample submission and result output. This can be done via convenient ASCII transfers. Method and calibration history Each chromatogram can easily be displayed under the same conditions as when it was printed, exported or saved. Column performance Calculations of peaks in terms of symmetry, efficiency, resolution; all by several methods. Batch Automatically batch processes, displays, exports or prints any number of chromatograms. Language localization available Basic version in English language. At the moment, there are French, German, Russian, Spanish and Chinese localizations available in single installation package.

ECS 8020 key points ü Fully automated analysis system ü High sensitivity, accuracy and precision ü Flexibility and versatility of applications ü Detector does not require reference gas ü Powerful software for viewing results from a computer ü Touch-screen display for an easy settings management ü Consumables status monitoring for an optimization of catalysts usage ü Three types of samplers available: electronic / pneumatic / manual. ü Easy connection to Mass Spectrometers and other detectors for stable isotopes analysis ü Low operation and management costs ü Standby mode for gas, energy and time savings

ECS 8020 application fileds ü Organic chemistry and pharmaceutical ü Soil science and geology- marine science (distinction between organic and inorganic carbon is available trough the previous acidification of the sample) ü Environmental analysis ü Petrol chemistry and energy ü Materials characterization ü Food (special configuration for big size samples is easily available)

Analytical and Technical Features ECS 8020 Features Type Analysis time Analytical range Accuracy* Precision* Sampler Dual furnace system Safety quick fit system Touch screen display Standby mode CHNS-O CN CHN CHNS O C H N S O <0.2% (certified standard; purity >99.9%) <0.1% (certified standard; purity >99.9%) Pneumatic autosampler Electronic autosampler Manual sampler 5 min 8 min 10/25 min 4 min 0.002-20 mg 0.002-5 mg 0.002-20 mg 0.002-6 mg 0.002-2 mg 147 positions max 32, 50, 100 positions * Accuracy and precision are related to samples nature and homogeneity. Physical Specifications Dimensions Weight Power supply Adsorbed power Gas requirements 81x50x37 cm 68 kg 230V, 50/60Hz 5A, 1100W Helium (99.999% purity), 3-5 bar Oxygen (99.999% purity), 3-5 bar Air (oil free compressed air)

Analytical and Technical Features Analytical Conditions Gas carrier Leak test Furnace temperature Oven temperature Oxygen volume need Flow rate Gas separation Detector Software data analysis Calibration Active calibration Helium Automatic Left Furnace : max 1100 C RightFurnace : max 1100 C Max 110 C Automatically calculated by the oxygen doser Electronic Flow Rate 0.8-4 m GC Column High Sensitivity TCD EAS Clarity Linear, Quadratic, Cubic As needed Sample Sample size Sample type Capsule 0.1-500mg (depending on sample nature) Up to 1 g for soil samples Liquid Solid High purity tin and/or silver capsule Accessories Installation kit Sampling kits Microbalance Consumables Technical assistance Small samples; big samples; deluxe kit Proprietary NC Technologies S.r.l. By phone or email within 24 hours customerservice@nctechnologies.it

Via Milano,15/A - 20060 Bussero (MI), Italy Phone: +39 02 950 34 69 www.nctechnologies.it