OPTICS IMPROVEMENTS OF THE K500 AXIAL INJECTION LINE

Similar documents
The Accelerator System for ReA3 the New Re-accelerated RIBs Facility at MSU

Preliminary Simulation of Beam Extraction for the 28 GHz ECR Ion Source

COMMISSIONING OF THE COUPLED CYCLOTRON SYSTEM AT NSCL

Design Note TRI-DN Low Energy Beam Transport Line for the CANREB Charge State Breeder

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Diagnostics Requirements for the ARIEL Low Energy Beam Transport

THE DESIGN AND COMMISSIONING OF THE ACCELERATOR SYSTEM OF THE RARE ISOTOPE REACCELERATOR ReA3 AT MICHIGAN STATE UNIVERSITY*

DEVELOPMENT OF LARGE SCALE OPTIMIZATION TOOLS FOR BEAM TRACKING CODES*

CYCLOTRON DEVELOPMENT PROGRAM AT JYVÄSKYLÄ

NSCL and Physics and Astronomy Department, Michigan State University Joint Institute for Nuclear Astrophysics

Refurbishment of the Electrostatic Accelerators of ithemba LABS

In-Flight Fragment Separator and ISOL Cyclotron for RISP

Development of Large Scale Optimization Tools for Beam Tracking Codes

Minicourse on Experimental techniques at the NSCL Fragment Separators

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

SLS at the Paul Scherrer Institute (PSI), Villigen, Switzerland

TRIUMF Document: 10049

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

HIGH CURRENT PROTON BEAM INVESTIGATIONS AT THE SILHI-LEBT AT CEA/SACLAY

Beam dynamics studies of H-beam chopping in a LEBT for project X

Small Isochronous Ring (SIR) project at NSCL, MSU. Eduard Pozdeyev NSCL, Michigan Sate University

Lattice Design and Performance for PEP-X Light Source

UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL

Extraction by stripping in the INFN-LNS Superconducting Cyclotron:

HIRFL STATUS AND HIRFL-CSR PROJECT IN LANZHOU

PIP-II Injector Test s Low Energy Beam Transport: Commissioning and Selected Measurements

3.2.2 Magnets. The properties of the quadrupoles, sextupoles and correctors are listed in tables t322_b,_c and _d.

Progress of RAON Heavy Ion Accelerator Project in Korea

Effect of the gas mixing technique on the plasma potential and emittance of the JYFL 14 GHz electron cyclotron resonance ion source

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

LOLA: Past, present and future operation

ELECTRON COOLING EXPERIMENTS IN CSR*

Design Note TRI-DN CANREB HRS Multipole Corrector

Extraction from cyclotrons. P. Heikkinen

6 Bunch Compressor and Transfer to Main Linac

EFFECT OF THE FIRST AXIAL FIELD SPECTROMETER IN THE CERN INTERSECTING STORAGE RINGS (ISR) ON THE CIRCULATING BEAMS

Upgrade of the HIT Injector Linac-Frontend

Introduction to accelerators for teachers (Korean program) Mariusz Sapiński CERN, Beams Department August 9 th, 2012

Bremsstrahlung and Ion Beam Current Measurements with SuSI ECR Ion Source

Optimization of the SIS100 Lattice and a Dedicated Collimation System for Ionisation Losses

Chopping High-Intensity Ion Beams at FRANZ

Modeling of an Extraction Lens System

Beamline Design for a Stern-Gerlach Deflection Experiment in CEBAF 1D Spectrometer Line

LCLS Injector Prototyping at the GTF

Medical Linac. Block diagram. Electron source. Bending magnet. Accelerating structure. Klystron or magnetron. Pulse modulator.

12. Acceleration and Normalized Emittance *

arxiv: v2 [physics.acc-ph] 21 Jun 2017

Use of Crab Cavities for Short X-ray Pulse Production in Rings

Basic Principle of Cyclotron

Development of the UNILAC towards a Megawatt Beam Injector

Investigation on the spiral inflector and central region of the IsoDAR test-bench cyclotron

2.6 Electron transport lines

ON BEAM INTENSITY UPGRADE IN THE COMMERCIAL CYCLOTRONS OF NEGATIVE HYDROGEN IONS

MAGNETS AND INSERTION DEVICES FOR THE ESRF II

A Multi Mega Watt Cyclotron Complex. to Search for CP violation in neutrino sector

Commissioning of PETRA III. Klaus Balewski on behalf of the PETRA III Team IPAC 2010, 25 May, 2010

Electron Beam Polarimetry at JLab Hall C Dave Gaskell PST 2009 September 7, 2009

TRI-DN-12-11: Electron High Energy Dump Transport (EHDT) Optics Design. Release: 7 Release Date: 2014/02/07

Update on Development of High Current Bunched Electron Beam from Magnetized DC Photogun

Developments of the RCNP cyclotron cascade

The SARAF 40 MeV Proton/Deuteron Accelerator

Study of Analyzing and Matching of Mixed High Intensity Highly Charged Heavy Ion Beams

STATUS OF THE TARN II PROJECT. T. Tanabe Institute for Nuclear Study, University of Tokyo, Tanashi, Tokyo 188, Japan

STUDY ON SPACE CHARGE COMPENSATION OF LOW ENERGY HIGH INTENSITY ION BEAM IN PEKING UNIVERSITY*

Accelerator Physics Final Exam pts.

S2E: Solenoidal Focusing

S2E: Solenoidal Focusing

Conceptual design of an accumulator ring for the Diamond II upgrade

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

04.sup Equations of Motion and Applied Fields *

IBA C400 Cyclotron Project for hadron therapy

The Booster has three magnet systems for extraction: Kicker Ke, comprising two identical magnets and power supplies Septum Se

Heavy Ion Accelerators for RIKEN RI Beam Factory and Upgrade Plans. Upgrade Injector

arxiv: v1 [physics.acc-ph] 16 Aug 2015

Target and Ion Source Development for Better Beams in the ARIEL Era

Performance of the ANL ECR Charge Breeder. with Low Mass Beams. Investigations with low mass species. Review of charge breeder design

Operation of the MAMI accelerator with a Wien filter based spin rotation system

Status of the EBIT in the ReA3 reaccelerator at NSCL

Status of the MAGIX Spectrometer Design. Julian Müller MAGIX collaboration meeting 2017

Notes on the HIE-ISOLDE HEBT

Design of a Sector Magnet for High Temperature Superconducting Injector Cyclotron

GTF Transverse and Longitudinal Emittance Data Analysis Technique * J.F. Schmerge, J.E. Clendenin, D.H. Dowell and S.M. Gierman

TEST MEASUREMENTS WITH THE REX-ISOLDE LINAC STRUCTURES*

arxiv: v3 [physics.acc-ph] 21 Mar 2018

Front end, linac upgrade, and commissioning of J-PARC. Y. Liu KEK/J-PARC, Japan

PRODUCT & SERVICE LIST

Tolerances for magnetic fields in the Gun-To-Linac region of the LCLS Injector *

STUDY OF THE TRANSVERSE BEAM EMITTANCE OF THE BERN MEDICAL CYCLOTRON

IFMIF mini-workshop on Beam Instrumentation. Ciemat, Madrid (Spain) 2-3 July 2007

Progress in April December 2007 Schedule in Jan. March 2008

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

02. Multipole Fields *

UPGRADE OF THE HIT INJECTOR LINAC-FRONTEND

Beam Diagnostics for Low Energy Proton and H - Accelerators. Vic Scarpine Fermilab 2012 BIW April 16-19, 2012

Tuning Techniques And Operator Diagnostics for FACET at SLAC National Accelerator Laboratory. Chris Melton SLAC Accelerator Operations

CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH THE CLIC POSITRON CAPTURE AND ACCELERATION IN THE INJECTOR LINAC

Lattice Design for the Taiwan Photon Source (TPS) at NSRRC

03.lec Solenoid Focusing*

arxiv: v1 [physics.acc-ph] 20 Jun 2013

ILC Damping Ring Alternative Lattice Design (Modified FODO)

Transcription:

Cyclotrons and Their Applications 27, Eighteenth International Conference OPTICS IMPROEMENTS OF THE K5 AXIAL INJECTION LINE M. Doleans, S. Chouhan, D. Cole, G. Machicoane, F. Marti, P. Miller, J. Moskalik, M. Steiner, J. Stetson, X. Wu, P. Zavodszky, A. Zeller, Q. Zhao, NSCL/MSU, East Lansing, MI 48824, U.S.A. Abstract Recent improvements in the K5 injection beam line optics have increased the injection efficiency into the K5 cyclotron and lead to record primary beam powers on the production target at the CCF (Coupled Cyclotron Facility). For example, consecutive improvements in the design of the electrostatic focusing system below the ion source have gradually increased the beam brightness. Also, degradation of the beam brightness by field aberrations in the existing analyzing bending magnets has been identified and remedied. During this effort, the offline source Artemis-B has been a key factor allowing in-depth R&D without reducing beam time for the CCF operation. In the beam studies, emphasis has been put toward systematic quantification of the beam brightness using Allison-type emittance scanners. arious improvements in the K5 injection beam line optics will be presented and discussed. REIEW OF INJECTION BEAMLINE IMPROEMENTS In the last three years, a sustained R&D effort has been carried at the NSCL to improve the beam brightness in the CCF injection beam line. For example, a new superconducting ion source, SuSI [1,2], has been built to replace the existing SC ion source and to increase the primary beam power for heavy ions. Early beam commissioning results of SuSI are discussed in [3]. In parallel, Artemis-B [4], an offline replica of the 14 GHz RT (Room Temperature) source Artemis was built in 25 and extensively used since for ion source and beam optics development. Artemis-B test stand has also been very valuable for the commissioning of new hardware prior to its installation in the injection beam line of the CCF. A current layout of the injection beamline is shown in Figure 1. RT (Artemis) SC K5 Double Quad. Doublet Einzel Lens Quad. Triplet emittance scanner Rf buncher J56SN J54SN 14SN J37SN J42Q J47Q J3DS J39DS J46SN R9DS J9DS RT leg R9DS R14SN R17Q emittance scanner J3DS J37SN J39DS SC leg J42Q J46SN J47Q J51DE J9DS J14Q Figure 1: Layout of the CCF beam injection line. Side view of RT (upper left), side view of SC and injection line (upper right) and top view of injection line (bottom). Magnetic focusing solenoids were replaced by electrostatic focusing systems under both sources to avoid possible space charge effects. After the charge state selection, magnetic and electrostatic elements are used for focusing. 319

Cyclotrons and Their Applications 27, Eighteenth International Conference Recent Hardware development included: Allison-type emittance scanner Electrostatic focusing elements before charge state selection New 9-degree analyzing magnets Horizontal and vertical movable slits system On-going hardware development includes: Beam chopper Grid-less two-harmonics rf-buncher Electrostatic spherical bender In addition to new hardware, swapping/addition of some beam line focusing elements were done to improve the beam matching into the K5 cyclotron. Finally, to help shortening the beam tuning time, automatic tuning software is being developed. In the next sections, developments related to the emittance scanner, to the electrostatic focusing elements below the and to the new analyzing magnet will be detailed. step motor Beam s1 x + p -p D s 2 FC Figure 2: NSCL Allison-type emittance scanner. See text for details. ALLISON EMITTANCE SCANNER The systematic use of the emittance scanner during R&D work on Artemis-B has been a key factor in the improvement of the injection beam line optics. The design of the NSCL Allison emittance scanner and is based on a similar device operated at LBL [5]. As shown in Figure 2, the emittance scanner box has entry and exit slits (s 1 and s 2 ) of 6x.5mm size separated by a distance D=75 mm. Between the slits, two deflecting voltage plates (± p ) are separated by a distance g=12 mm. After the second slit a Faraday Cup (FC) collects the beamlet currents. The emittance box is scanned across the beam using a step g motor and at each position the voltages on the plates are scanned to collect all possible beamlet angles. The relation between the voltage on a the plates and the angle is p = 2g D where is the extraction voltage and for example, particles with x =5 mrad extracted at =25 k need p =4 to be collected in the Faraday cup of the emittance scanner box. After the emittance is measured, a brightness curve (i.e. beam current within emittance) is generated. Examples of emittance measurements and details about the emittance scanner software were presented in [6]. arious focusing elements were tested below Artemis-B and the beam brightness measured in each case. Particularly, the difference between magnetic focusing elements and electrostatic elements was investigated. x' FOCUSING AFTER : MAGNETIC S ELECTROSTATIC Basic scaling laws Ion beams extracted from have multiple charge states and possibly multiple species (e.g. when a support gas is used). These beams are nonrelativistic and the electrostatic and magnetic rigidities are given by Eρ = 2 Bρ = 2m e A Q with m the atomic mass unit and e the elementary charge and with A/Q the mass to charge ratio of the considered ion. For convenience, the second equation can be rewritten Bρ [ T m] 4.554 1 3 A Q [ k ] For example, a 4 Ar 7+ beam extracted at 25 k from the has Bρ ~.544 T-m. As shown in [7], below β~1.7x1-2 electrostatic focusing devices are more efficient than magnetic elements. At the CCF, beams injected into the K5 cyclotron have typical velocities β~.3 and magnetic and electrostatic focusing options are almost equally efficient. Nonetheless, the previous equations show that the electrostatic rigidity is independent of the mass and charge of the ion whereas the magnetic rigidity scales with the square root of their ratio. As explained in the next section, this difference makes the magnetic option more susceptible to beam brightness degradation from space charge effects. Space charge effects for magnetic focusing At the CCF, focusing solenoids were originally used as focusing elements between the ion sources and the analyzing magnets. In some cases, images of the beam on 32

Cyclotrons and Their Applications 27, Eighteenth International Conference viewer plates of the K5 injection line appeared hollow [8]. This observation was attributed to the effect of space charge forces from ions with higher Q/A than the ion of interest [9]. To avoid such problems it was proposed to replace the magnetic focusing solenoids with electrostatic focusing elements. Beam simulations using a Particle-In- Cell code were performed to estimate the possible gain in beam brightness [1]. Though hollow beams were observed, the degradation of the beam emittance caused by the space charge forces wasn t quantified experimentally. Such a beam study was recently conducted on Artemis B and detailed results can be found in [11]. The main results from this study are reproduced below. beam current in Faraday cup (eua) 4 35 3 25 2 15 1 5 Ar 1+ Ar 11+ Ar 9+ Ar 8+ Ar 7+ Ar 6+ Ar 5+ Ar 4+ 1 125 15 175 2 225 25 current in 9-deg analyzing magnet (A) 15 W 9 W Ar 3+ Figure 3: Charge State Distribution (CSD) for Argon beam measured on Artemis-B for 15 W and 9 W of rf microwave power injected into the plasma. Deformations on the outside edge of the beam can be observed on every pictures. This effect is due to the focusing solenoid leads, which run parallel to the beam axis for a few centimeters and generate azimuthal magnetic field components. The azimuthal components interact with the axial velocity of the ions and lead to radial aberrations [12]. Ar1+ Ar9+ Ar8+ Ar7+ Ar6+ Ar5+ Ar4+ Figure 4: Pictures of the different charge states of an Argon beam on a beam viewer located one meter after the analyzing magnet for the 15 W case. Ar11+ Ar1+ Ar9+ In the measurements, an Argon beam was produced by the Artemis-B ion source without support gas and extracted at 2k. The source was kept in the same conditions throughout the measurements and only the microwave power level was changed. In a first case, the source was run with only 15 W of microwave power. In a second case, the source was run at 9 W. The CSD (Charge State Distribution) for these two cases is shown in Figure 3. The total beam current extracted from the source was.5 ma and 2 ma for the low and high power case respectively. In both measurements, the transmission efficiency from the to the faraday cup after the analyzing magnet was 8%. In the 9 W case, the proportion of higher charge state ion (i.e. Q>7+) is dramatically increased compared to the 15 W case. This is the most important difference between the two cases since space charge effects from higher Q/A ions on lower Q/A ions is the main cause of beam brightness degradation. Pictures for the different charge states of the Argon beam were recorded on a beam viewer located one meter after the Faraday cup and are shown in Figure 4 for the low power case and in Figure 5 for the high power case. To obtain the pictures, the magnetic fields in the focusing solenoid and in the analyzing magnet were successively adjusted according to the magnetic rigidity of each particular charge state. Ar8+ Ar5+ Ar7+ Ar4+ Ar6+ Ar3+ Figure 5: Same as Figure 4 but for the 9 W case. The beam pictures for the 15 W and 9 W are significantly different. For the lower power case, all the charge state pictures have similar features beside for the difference in overall intensity and for some finer details that are not yet understood (e.g. bright spots in the middle). For the higher power case, the difference between the pictures of the different charge states is much more pronounced with the lower charge states (i.e. Q<6+) having hollow distributions. The significant difference between the low and high power measurements is consistent with effects from space charge forces. In the low power case, the beam current for all the charge states is small and space charge forces are negligible. In the high power case, the higher Q/A beams produce significant 321

Cyclotrons and Their Applications 27, Eighteenth International Conference repulsive forces on the core part of the lower Q/A beams that lead to hollow beam distributions. 4 Ar 4+ - 9W 4 Ar 9+ - 9W Figure 6: Transverse emittances for Ar 4+ and Ar 9+ beams for the 9 W case. The Ar 4+ emittances are hollow while the Ar 9+ emittances are centered on a core. For the 15 W case no hollow emittances could be observed. Further characterization was done for Ar 4+ up to Ar 9+ by measuring the horizontal (xx ) and vertical (yy ) beam emittances in the Allison emittance scanner. The scanner was located 2.5 m after the analyzing magnet and a solenoid was used in between to refocus the beam. The measured emittances for Ar 4+ and Ar 9+ in the high power case are shown in Figure 6. The phase space distributions for Ar 9+ are centered on intense cores while the distributions for Ar 4+ appear hollow. This result is in qualitative agreement with the pictures observed on the beam viewers upstream. The percentage of beam included within a given emittance for Ar5+ for the two different cases of microwave power are plotted in Figure 7. The emittance of Ar5+ has degraded significantly as the microwave power was increased, going from 6 % of beam included within 1 π.μm for the case at 15 W to about 3 % for the case at 9 W. The experimental results collected on Artemis-B are consistant with the beam brightness degradation by space charge forces. In the low space charge regime, the focusing solenoid is an efficient focusing element. In the high space charge regime, using a solenoid can lead to significant beam emittance degradation. Because space charge effects were found to be a problem for some beams at the NSCL, development of electrostatic focusing systems below the s was pursued. beam current within emittance (%) 1 9 8 7 6 5 4 3 2 1 15W xx' 15W yy' 9W xx' 9W yy' Low space charge High space charge Ar5+ 25 5 75 1 125 15 175 2 225 25 emittance (π.μm) Figure 7: Transverse beam emittances for Ar 5+ beam and for the two different cases of microwave power. For the low power case, the space charge forces are small and have a negligible effect on the beam brightness. In the high power case, the space charge forces are significant and the brightness is degraded. Electrostatic focusing system design The first electrostatic system designed and installed at the NSCL was a small bore electrostatic quadrupole triplet. Because of its modest three-inch aperture, the beam transmission efficiency from the to the analyzing magnet was poor (~25% compared to ~8% for the solenoid) but encouraging results were nonetheless achieved in the CCF using this device [8]. The limitation in the beam transmission was overcome by the installation of a Large Bore Triplet (LBT) with six-inch aperture. In spite of the better transmission, beam simulation studies showed that the aberrations in the LBT were limiting the beam brightness [1]. As shown in [13], the intrinsic aberrations in electrostatic quadrupoles are of third order and the criteria for negligible emittance degradation can be written β << f β and ε are the transverse beta function and geometrical emittance of the beam respectively, L is the length of the quadrupole. and f is the focal length given by L ε a f = L with the extraction voltage from the and with a and the radial aperture and voltage on the quadrupole electrodes. Using typical values, f=.5 m, L=1cm and ε=15 π.μm, one finds the criteria β << 13 m to avoid large aberrations. Using quadrupoles to focus beams typically gives β >> 1m. Thus, aberrations in the quadrupoles can be large and limit the beam brightness which is consistent with results from beam simulations. 2 322

Cyclotrons and Their Applications 27, Eighteenth International Conference As mentioned in [13], increasing the length of the quadrupole reduces the aberrations. Since the aberrations are of third order, an octupole can also be used for active correction. Based on these two observations, a Double quadrupole Doublet with correcting octupole (DD) was designed and procured. The DD is currently installed under the RT at the CCF as shown in Figure 1. Eventually, another scheme was proposed to reuse the LBT. In this scheme, an Einzel Lens (EZ) was fabricated and installed between the source and the LBT. The Einzel reduces the divergence of the beam and the beam size in the LBT and limits the brightness degradation in this device. The system EZ+LBT is currently installed under the SC at the CCF as shown in Figure 1. beam current (eua) 8 7 6 5 4 3 2 1 DD EZ+LBT Solenoid (low space charge) Ar7+ 5 1 15 2 25 emittance (pi.mm.mrad) Figure 8: Beam brightness for the two electrostatic systems currently used under the production sources at the CCF. The beam brightness for the solenoid system with low space charge effects is also given for comparison. All cases are for a 2 k 4 Ar 7+ beam from Artemis-B. analyzing magnet could significantly degrade the beam brightness. Limiting the beam size below 25 mm in the dipole by appropriately tuning the focusing elements above was done to mitigate the degradation of the beam brightness. Nonetheless, forcing a small beam size inside the dipole impacted the charge states selection because of the larger beam size at the collimating aperture. Thus, procuring new analyzing magnets with smaller field aberrations was pursued. Table 1: Main parameters for the new analyzing magnets Parameter alue Unit Bending angle 9 degrees Bending radius 4.6 cm Gap 1 cm Pole face angles 28.5 degrees # of coils per magnet # of turns per coil 2 36 Magnetic field 1.64 kg Current 2 Α oltage 16 Power 3.2 kw The main design parameters for the new magnet are given in Table 1. The new 9-degree dipole is a room temperature H-type magnet that can transport a 2 π.μm beam without significant degradation of its brightness while still achieving good charge state separation. - - In Figure 8, the beam brightness for the DD and EZ+LBT systems are compared to the one for a solenoid with low space charge effects. Within the estimated 75 π.μm acceptance of the K5 cyclotron [14], the three systems are almost equivalent. Nonetheless, as mentioned above, the beam brightness using electrostatic systems is mildly affected by space charge effects whereas it can be significantly degraded when a solenoid is used. In all cases of Figure 8, the focusing devices were tuned to obtain a waist in the analyzing magnet downstream. This tuning scheme was applied to avoid significant sextupole aberrations in the analyzing magnet. New magnets with a larger linear aperture have since been designed and procured. NEW 9-DEGREE ANALYZING MAGNET Beam dynamics studies on Artemis B have shown that the beams have typically geometric transverse emittances around 2 π.μm. For beams with such emittances, the field aberrations of the old 9-degree Figure 9: New analyzing magnet installed under Artemis- B in July 27. The port on the left can be used for pumping. The 2-D design was done with Poisson and the 3-D design with TOSCA. The fabrication is done in collaboration with the Texas A&M University Cyclotron Institute (TAMU-CI). Four new magnets are planned for 323

Cyclotrons and Their Applications 27, Eighteenth International Conference the NSCL and five for TAMU-CI. The magnet yokes and beam chambers are being fabricated at the NSCL while the coils were wound by TAMU-CI. Two new magnets have already been built and installed under Artemis and Artemis-B ion sources at the NSCL. A picture of the new magnet during its installation on Artemis-B is shown in Figure 9. The quality control of the magnet was done using an identical beam test in the experiment and beam simulations. The simulations were done with KOBRA [15] using the 3D field maps calculated in TOSCA. For the commissioning test, a 4 Ar 7+ beam extracted at 2 k is deflected horizontally and vertically using a steerer located one meter above the magnet and the beam centroid position is recorded on a beam viewer located 1.5 m after the magnet for each steerer setting. In the experiment, the magnetic steerer gave deflections of approximately 1 mrad/a. The simulated and measured response curves shown in Figure 1 are in good agreement proving that the magnet is performing according to design. centroid position on viewer (mm) centroid position on viewer (mm) 4 3 2 1-1 -2-3 -4-3 -2-1 1 2 3 4 3 2 1-1 -2-3 dx measured dx simulated Horizontal steerer current (A) dx measured dx simulated dy measured dy simulated dy measured dy simulated -4-3 -2-1 1 2 3 ertical steerer current (A) Beam loss on the cyclotron deflectors and stripper foil lifetime are becoming two limiting factors to further increase the beam power. Ongoing R&D activities are trying to address these limitations. REFERENCES [1] P.A. Závodszky et al., Nucl.Instr.Meth.B 241 (25) 959 [2] P.A. Závodszky et al., Rev. Sci. Instr. 77, 3A334 (26) [3] P.A. Závodszky et al., First Commissioning Results of the SuSI IS these proceedings [4] G. Machicoane et al., Rev. Sci. Instr. 77, 3A322 (26). [5] M. Leitner, Emittance Scanner Specification for the 88 Injector Beamlines Technical Note, LBL [6] G. Machicoane et al., R&D effort at NSCL with the off line ion source Artemis-B, Proceedings of the 17th International Workshop on Ion Sources, Lanzhou China, September 26 [7] M. Reiser, Theory and design of charged particle beams, Wiley series in beam physics, ISBN -471-3616-9 [8] J.W. Stetson et al., A Comparison of Electrostatic and Magnetic Focusing of Mixed Species Heavy Ion Beams at NSCL/MSU Proceedings of PAC5, Knoxville, Tennessee, May 25. [9] N. Kazarinov Rev. Sci. Instr. 75, 1665 (24) [1] Q. Zhao et al., Simulations of Solenoid and Electrostatic Quadrupole Focusing of High Intensity Beams from Ion Source at NSCL, Proceedings of PAC5, Knoxville, Tennessee, May 25. [11] G. Machicoane et al., Experimental Evidences for Emittance Degradation by Space Charge Effects when using a focusing Solenoid below an ion Source, Proceedings of ICIS27, Jeju, South Korea, August 27 [12] F. Marti, NSCL internal note system [13] R. Baartman, Aberrations in electrostatic quadrupoles TRI-DN-95-21, TRIUMF, June 1995 [14] S. L. Snyder, Study and Redesign of the NSCL K5 Injection, Central Region and Phase Selection Systems, Ph.D. Thesis, Michigan State University, 1995 [15] P. Spaedtke, KOBRA3-INP, 25. Figure 1: Simulated and experimental beam centroid response curves to horizontal (top) and vertical (bottom) deflection from a steerer located upstream of the new analyzing magnet. The centroid is measured on a beam viewer downstream of the analyzing magnet. CONCLUSION Significant increase in primary beam power has been achieved in the last three years at the CCF. A few beams have reached more than a kilowatt on production target and the improvements made in the injection beam line have largely contributed to the increase in performance. 324