Book 14 Edition 1.1 March Socketable Flat LED Module and LED Light Engine

Similar documents
E/ECE/324/Rev.2/Add.127/Amend.4 E/ECE/TRANS/505/Rev.2/Add.127/Amend.4

LED Modules. Fortimo LED Line

Catalog # Project. Comments

LED Modules. Fortimo LED Line

3M Pak 10 Plug, PK10 series PK10-XXXPX-X-DA. 3M Pak 10 Socket, PK10 series PK10-XXXSX-X-DA

Best color perception in spotlighting and downlighting

Experience bright and vivid colors

3M Pak 50 Boardmount Socket, P50 series P50-XXXS-XXX-EA. 3M Pak 50 Boardmount Plug, P50 series P50-XXXP-XXX-EA

Measurement method for the proficiency testing program

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

Economic and Social Council

3M HDC Socket.100 Right Angle, PCB, 3 or 4-Row, Solder Tail or Press-Fit HDC Series

The slimmest Panel with highest efficacy in the market

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

Economic and Social Council

Economic and Social Council

INTERNATIONAL STANDARD

SnapLED 150. Reliability and robustness AUTOMOTIVE. SnapLED 150 cold clinching technology provides automotive exterior

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE

Tunable White LED compact

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement

HONOURTEK Delux Array Series HRA0407 Preliminary

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE

Impact of New SSL Standards on Goniospectroradiometric Measurements

SignalSure 150. Mid power solution AUTOMOTIVE. SignalSure 150 is a compact, surface-mount, mid power LED signaling

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

LED light engines LED linear / area

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

LED light engines LED linear / area

Evaluating performance of LED based luminaires Guidance Paper

LED light engines LED linear / area. Modules LLE ADVANCED

LED light engines LED compact. Module DLE G4 ADV Modules DLE

3M CF Card Header CompactFlash Type I, Low Profile, Long Guides, SMT, Inverse

LED light engines LED linear / area

Revision of GRE/2017/05

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

HONOURTEK Delux Array Series HRA0303 Preliminary

Optical differentiation with third party lenses

Economic and Social Council

LED light engines LED linear / area. Module RLE PL1 EXC2 OTD Modules RLE EXCITE

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

Method of Measuring Machinery Sound Within an Equipment Space

The official directions are written in Chinese, this English edition is for your reference only -1-

Experience bright and vivid colors

PrevaLED COIN 50 COB G1

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED

LED light engines LED linear / area

Product Data Sheet PD-0036-B. 3M PC Boardmount Plug and Receptacle, 2 mm 95X Series

industry hall : highbay luminaire NJ700 LED Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 07/2013

LED Modules. Fortimo LED Strip NA LV4. 24in 2200lm

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

MODEL NAME : LLDMWW0-15K*0*A

Data Sheet. HLMP-4700 T-1 3 / 4 (5 mm), T-1 (3 mm), Low Current LED Lamps HLMP-4700, HLMP-4719, HLMP-4740 HLMP-1700, HLMP-1719, HLMP-1790

HLMP-1600, HLMP-1601, HLMP-1620, HLMP-1621 HLMP-1640, HLMP-1641, HLMP-3600, HLMP-3601 HLMP-3650, HLMP-3651, HLMP-3680, HLMP-3681

Cree XLamp CXA2 Studio LED

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

TEST REPORT IEC Photobiological safety of lamps and lamp systems

LuxSpace recessed high efficiency, visual comfort and a stylish design

LED light engines LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE Shallow G1 ADV Modules QLE ADVANCED

Technical Application Guide for Phaeton LED Floodlight

NO LONGER ORDERABLE LUXEON S. Best punch and easy integration. For NEW designs consider these replacement products: ILLUMINATION

LED light engines LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE EXCITE

LED light engines LED linear / area. Module QLE G3+ ADV Modules QLE ADVANCED

Cree XLamp CXB2530 LED

PrevaLED COIN 50 DC COB G1

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

LED light engines LED linear / area

3M MetPak CP2 Press-Fit Header 2 mm Type C, 55 Signal Contacts, Left Guidance CP2 Series

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED

RS1A - RS1M Fast Rectifiers

LED light engines LED linear / area

ISO INTERNATIONAL STANDARD. Geographic information Spatial referencing by coordinates

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

LUXEON UV U1. Highest power density, superior efficiency, powered by leading Chip Scale Package (CSP) technology ILLUMINATION

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

LED light engines LED linear / area

E/ECE/324/Rev.2/Add.127/Amend.7 E/ECE/TRANS/505/Rev.2/Add.127/Amend.7

Square. CertaFlux LED. Datasheet. CertaFlux LED Square 2500lm 8xx HV/LV1

Conductive Polymer Aluminum Capacitors SMD (Chip), Low Impedance

CL-L102-C7D. 1. Scope of Application. These specifications apply to LED package, model CL-L102-C7D. 2. Part code

NEMA MW (R2014) Dynamic Coefficient of Friction of Film-Insulated Magnet Wire

Data sheet FIXED CHIP RESISTORS; RECTANGULAR TYPE & WIDE TERMINATION. AEC-Q200 qualified. RoHS COMPLIANCE ITEM Halogen and Antimony Free

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

Data Sheet. ADJD-xMxx. High Power Light Strip, Ring & Round. Description. Features. Applications. Specifications

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

PRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 3000K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 1.0.

Brighter and Cooler. 95CRI Luna 200. Best Lumen / Watt LED Flip Chip COB Module

Table of Contents. DS133 LUXEON TX Product Datasheet Lumileds Holding B.V. All rights reserved.

INTERNATIONAL STANDARD

Installation guide 862 MIT / MIR

Surface Mount Multilayer Ceramic Chip Capacitors for Safety Certified Applications

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 EXC umodule SLE EXCITE

POLE WHEELS. Where the shaft is very large a cost-effective alternative is to add a pole band (see following section).

LED light engine / OLED LED linear / area

Transcription:

Book 14 Edition 1.1 March 2017 Socketable Flat LED Module and LED Light Engine

Book 14 Summary (informative) Background The Zhaga Consortium is a global lighting-industry organization that aims to standardize components of LED luminaires, including LED light engines, LED modules, LED arrays, holders, electronic control gear (LED drivers) and connectivity fit systems. Zhaga has created a set of interface specifications, known as Books. Each Book defines one or more components of an LED luminaire by means of the mechanical, photometric, electrical, thermal, and control interfaces of the component to its environment. This makes such products interchangeable in the sense that it is easy to replace one product with another, even if they have been made by different manufacturers. Contents This Book 14 defines three socketable LED light engines (with integrated electronic control gears) and three socketable LED modules (without integrated electronic control gears). The intended application is in free air or in a Luminaire that does not introduces a significant temperature increase. Each LED module and LED light engine is identified by a designation. The LED Modules and the LLEs feature contact caps which fit in corresponding contact holders of the luminaire. The contact caps and contact holders have keys matching specific electrical characteristics of the LED module or the LED light engine. Each key is identified by a designation. This Book should be read together with Zhaga Book 1. Intended Use The LED modules and the LED light engines defined in this Book 14 are intended to be installed and replaced by professionals and non-professionals.

COPYRIGHT The is published by the Zhaga Consortium, and has been prepared by the members of the Zhaga Consortium. All rights are reserved. Reproduction in whole or in part is prohibited without express and prior written permission of the Zhaga Consortium. DISCLAIMER The information contained herein is believed to be accurate as of the date of publication. However, neither the Zhaga Consortium, nor any member of the Zhaga Consortium will be liable for any damages, including indirect or consequential, from use of the or reliance on the accuracy of this document. CLASSIFICATION The information contained in this document is for public use. NOTICE For any further explanation of the contents of this document, or in case of any perceived inconsistency or ambiguity of interpretation, visit www.zhagastandard.org or contact info@zhagastandard.org.

Table of Contents 1 General... 6 1.1 Introduction... 6 1.2 Scope... 6 1.3 Conformance and references... 6 1.3.1 Conformance... 6 1.3.2 References... 7 1.4 Definitions... 7 1.5 Acronyms... 7 1.6 Symbols... 7 1.7 Conventions... 7 1.7.1 Precedence... 7 1.7.2 Cross references... 7 1.7.3 Informative text... 7 1.7.4 Terms in capitals... 7 1.7.5 Units of physical quantities... 8 1.7.6 Decimal separator... 8 1.7.7 Limits... 8 2 Overview (Informative)... 9 2.1 General... 9 2.2 Description of the LED Module and the LED Light Engine... 9 2.3 Outline of this Book... 9 Part 1: Interface Definition 3 Mechanical interface... 12 3.1 Drawing principles... 12 3.2 Overview of the mechanical interface... 12 3.3 Definition of the mechanical interface of the LED Module and LED Light Engine... 12 3.3.1 Definition of Book 14 LED Modules or LLEs for different categories... 12 3.3.2 Definition of the support Cap... 14 3.3.3 Definition of contact Caps... 15 3.3.4 Mass... 17 3.4 Definition of the mechanical interface of the Luminaire... 18 3.4.1 Definition of Book 14 Luminaires for different categories... 18 3.4.2 Definition of the support Holder... 19 3.4.3 Definition of contact Holders... 21 4 Photometric interface... 24 4.1 Light Emitting Surface... 24 4.2 Operating conditions... 24 4.3 Luminous flux... 24 4.4 Luminous intensity distribution... 24 4.5 Luminance uniformity... 24 4.6 Correlated color temperature... 24 Zhaga Consortium, March 2017 i

4.7 Color rendering index... 24 5 Electrical interface... 25 5.1 Electrical interface between LED Module and Luminaire... 25 5.1.1 Nominal input current and forward voltage... 25 5.1.2 Electrical insulation... 26 5.1.3 Hot plugging... 26 5.2 Electrical interface between LLE and Luminaire... 26 5.2.1 Mains power... 26 5.2.2 Electrical insulation... 26 6 Thermal interface... 27 7 Control interface... 28 7.1 Dimming (optional)... 28 Part 2: Compliance Tests 8 Compliance test tools... 30 8.1 LED Module/LED Light Engine test tools... 30 8.1.1 Gauges for test of mechanical interface... 30 8.1.2 Test Fixture PETF (photometric and electrical)... 38 8.2 Luminaire test tools... 39 8.2.1 Gauges for test of mechanical interface... 39 9 LED Module/LED Light Engine Compliance Tests... 50 9.1 LED Module/LED Light Engine mechanical interface tests... 50 9.1.1 Test of the dimensions D, W, H and A of the LLE... 50 9.1.2 Test of the contact Cap of the LED Module or LLE... 50 9.1.3 Test of the retention path of the contact Cap of the LED Module or LLE... 50 9.1.4 Test of the contact position of the contact Cap of the LED Module or LLE... 51 9.1.5 Test of the key dimensions of the contact Cap of the LED Module or LLE... 51 9.1.6 Test of the key of the contact Cap of the LED Module or LLE... 51 9.1.7 Test of the support Cap of the LED Module or LLE... 52 9.2 LED Module/LED Light Engine photometric interface tests... 52 9.2.1 Test on luminous flux... 52 9.2.2 Test on correlated color temperature (CCT)... 52 9.2.3 A.1.2.4 Test on color rendering index... 52 9.3 LED Light Engine Electrical interface tests... 52 9.4 LED Module Electrical interface tests... 52 9.5 LED Module/LED Light Engine thermal interface tests... 53 9.6 LED Light Engine control interface tests... 53 9.6.1 Test of dimming functionality... 53 9.7 LED Module/LED Light Engine Product Data Set test... 53 10 Luminaire compliance tests... 54 10.1 Luminaire mechanical interface tests... 54 10.1.1 Test of the dimensions L, W, H and A1 of the Luminaire... 54 10.1.2 Test of the contact Holder of the Luminaire part 1... 54 10.1.3 Test of the contact Holder of the Luminaire part 2... 54 10.1.4 Test of the contact Holder of the Luminaire part 3... 55 10.1.5 Test of the key of the contact Holder of the Luminaire part 1... 55 Zhaga Consortium, March 2017 ii

10.1.6 Test of the key of the contact Holder of the Luminaire part 2... 55 10.1.7 Test of support Holder of the Luminaire... 56 10.2 Luminaire for LED Light Engine Electrical interface tests... 56 10.3 Luminaire for LED Module Electrical interface tests... 56 10.4 Luminaire Product Data Set test... 57 Annexes Annex A Product Data Set requirements... 59 A.1 LED Module/LED Light Engine Product Data Set... 59 A.2 Luminaire Product Data Set... 59 Annex B History of Changes... 60 Zhaga Consortium, March 2017 iii

List of Figures Figure 1-1: 3D-drawings of the Book 14 LED Module or LED Light Engine (informative).... 6 Figure 2-1: Schematic overview of the Book 14 LED Module or LLE with Caps and Luminaire with Holders.... 9 Figure 3-1: Mechanical dimensions of the Book 14 LED Module and LED Light Engines... 12 Figure 3-2: Mechanical dimensions of the support Cap... 14 Figure 3-3: Mechanical dimensions of the contact Cap (Key GR6d-1 as example)... 15 Figure 3-4: Key specific dimensions of the contact Cap... 17 Figure 3-5: Mechanical dimensions of Book 14 luminaires... 18 Figure 3-6: Mechanical dimensions of the support Holder... 19 Figure 3-7: Mechanical dimensions of the contact Holder (Key GR6d-1 as example)... 21 Figure 3-8: Key specific dimensions of the contact Holder... 23 Figure 8-1: Mechanical dimensions... 30 Figure 8-2: Mechanical dimensions... 32 Figure 8-3: Mechanical dimensions of the GO gauge... 33 Figure 8-4: Mechanical dimensions NOTGO gauge... 33 Figure 8-5: Mechanical dimensions... 35 Figure 8-6: Mechanical dimensions for GR6D-1... 36 Figure 8-7: Mechanical dimensions for GR6D-1 until and with GR6D15... 37 Figure 8-8: Mechanical dimensions... 38 Figure 8-9: Mechanical dimensions... 39 Figure 8-10: Mechanical dimensions... 41 Figure 8-11: Mechanical dimensions... 43 Figure 8-12: Mechanical dimensions for GR6d-1... 44 Figure 8-13: Mechanical dimensions for GR6D-1 until and with GR6D15... 45 Figure 8-14: Mechanical dimensions for GR6d-1... 46 Figure 8-15: Mechanical dimensions for GR6D-1 until and with GR6D15... 47 Figure 8-16: Mechanical dimensions of GO gauge... 48 Figure 8-17: Mechanical dimensions of NOTGO gauge... 48 Zhaga Consortium, March 2017 iv

List of Tables Table 3-1: Values of dimensions for the Book 14 LED Modules and LED Light Engines... 13 Table 3-2: Values of dimensions for the support Cap... 14 Table 3-3: Values of dimensions for the contact Cap... 16 Table 3-4: Values of dimensions for the Book 14 Luminaire... 18 Table 3-5: Values of dimensions for the support Holder... 20 Table 3-6: Values of dimensions for the contact Holder... 22 Table 5-1: Electrical input characteristics of the LED Module... 25 Table 5-2: Electrical output characteristics of the Luminaire... 25 Table 5-3: Mains power characteristics of the LLE and the Luminaire... 26 Table 8-1: Values of dimensions... 31 Table 8-2: Values of dimensions... 32 Table 8-3: Values of dimensions... 34 Table 8-4: Values of dimensions... 35 Table 8-5: Values of dimensions... 36 Table 8-6: Values of dimensions... 38 Table 8-7: Values of dimensions... 40 Table 8-8: Values of dimensions... 42 Table 8-9: Values of dimensions... 43 Table 8-10: Values of dimensions... 45 Table 8-11: Values of dimensions... 47 Table 8-12: Values of dimensions... 49 Table B-1: Changes from Edition 1.0 to Edition 1.1.... 60 Zhaga Consortium, March 2017 v

General 1 General 1.1 Introduction The Zhaga Consortium is a global organization that aims to standardize components of LED Luminaires. A LED Luminaire is a lighting fixture for general lighting that contains a light source based on solid-state technology. Such light sources, including LED Modules and LED Light Engines, typically consist of one or more LEDs combined with an Electronic Control Gear (LED driver). Other components of LED Luminaires include LED Arrays, Holders, and connectivity fit systems. Zhaga has created a set of interface specifications, known as Books, which define the interfaces between a component and its environment. Book 1 is a special Book in the sense that it provides common information, which is relevant to all other Books in the series. In addition, Book 1 defines requirements and compliance tests, which are applicable across multiple Zhaga books. Such Books refer to those requirements and compliance tests as applicable. 1.2 Scope Figure 1-1: 3D-drawings of the Book 14 LED Module or LED Light Engine (informative). This Book 14 defines three socketable LED Light Engines (with integrated Electronic Control Gears) and three socketable LED Modules (without integrated Electronic Control Gears). These LED Modules and LLEs have a rectangular shape and are typically applied in general lighting applications. These products are intended to be installed and replaced by professionals and non-professionals. Figure 1-1 shows informative 3D-drawings of such a LED Module or LLE. The intended application is in free air or in a Luminaire that does not introduces a significant temperature increase. Each LED Module and each LED Light Engine is identified by a designation. The LED Modules and the LLEs feature contact Caps which fit in corresponding contact Holders of the Luminaire. The contact Caps and contact Holders have keys matching specific electrical characteristics of the LED Module or LED Light Engine. Each key is identified by a designation. 1.3 Conformance and references 1.3.1 Conformance All provisions in the Zhaga interface Specifications are mandatory, unless specifically indicated as recommended, optional or informative. Verbal expressions of provisions in the Zhaga interface specifications follow the rules provided in Annex H of ISO/IEC Directives, Part 2. For clarity, the word shall indicates a requirement that is to be followed strictly in order to conform to the Zhaga interface specifications, and from which no deviation is permitted. The word should indicates that among several possibilities one is recommended as particularly suitable, without mentioning or excluding others, or that a certain course of action is preferred but not necessarily required, or that (in the negative form) a certain possibility or course of action is deprecated but not prohibited. The word may indicates a course of action Zhaga Consortium, March 2017 6

General permissible within the limits of the Zhaga interface specifications. The word can indicates a possibility or capability, whether material, physical or causal. 1.3.2 References For references that are not listed in this section, see [Book 1]. For undated references, the most recently published edition applies. [Book 1], Book 1: Overview and Common Information. [IEC60598-1] Luminaires Part 1: General requirements and tests, IEC 60598-1. [NEMA SSL 7A] Phase Cut Dimming for Solid State Lighting: Basic Compatibility, NEMA SSL 7A-2013. 1.4 Definitions This section defines terms that have a specific meaning in the context of this Book 14. Terms that have a specific meaning across all Zhaga Books are defined in [Book 1]. Book-14 LED Light Engine Cap Holder 1.5 Acronyms LED Light Engine according to the specifications in this book. The part of the LED Light Engine or LED Module which fits in the Holder of the Luminaire. The Cap/Holder combination serves to retain the LED Light Engine or LED Module in the Luminaire. The Cap/Holder combination may also provide electrical connections between LED Light Engine or LED Module and the Luminaire. The part of the Luminaire which fits to the CAP of the LED Light Engine or LED Module. The Cap/Holder combination serves to retain the LED Light Engine or LED Module in the Luminaire. The Cap/Holder combination may also provide electrical connections between LED Light Engine or LED Module and the Luminaire. Acronyms that have a specific meaning across all Zhaga Books are defined in [Book 1]. 1.6 Symbols Symbols that have a specific meaning across all Zhaga Books defined in [Book 1]. 1.7 Conventions This section defines the notations and conventions used in the s. 1.7.1 Precedence In the case of any perceived discrepancy between the definitions provided in Part 1 of this document, Interface Definition and the definitions provided in Part 2 of this document, Compliance Testing, the definitions provided in Part 2 take precedence over the definitions provided in Part 1. 1.7.2 Cross references Unless indicated otherwise, cross references to sections include the sub sections contained therein. 1.7.3 Informative text Informative text is set in italics, unless the whole section is marked as informative. 1.7.4 Terms in capitals Terms that have a specific meaning in the context of this Book 14 are capitalized. See section 1.4. Zhaga Consortium, March 2017 7

General 1.7.5 Units of physical quantities Physical quantities are expressed in units of the International System of Units. All lengths that omit an explicit unit indication are in millimeters. 1.7.6 Decimal separator The decimal separator is a comma. 1.7.7 Limits Values that are indicated as typical, as well as values between parentheses, are informative. Zhaga Consortium, March 2017 8

Overview (Informative) 2 Overview (Informative) 2.1 General General information with respect to the s and certification of products that comply with this Book 14 can be found in [Book 1], section 2. 2.2 Description of the LED Module and the LED Light Engine Luminaire Contact Holder Support holder Support Cap LED Module or LLE Contact Cap Figure 2-1: Schematic overview of the Book 14 LED Module or LLE with Caps and Luminaire with Holders. A schematic overview of the Book 14 LED Module or LLE with Caps and Luminaire with Holders is depicted in Figure 2-1. This Book 14 defines: 3 LED Module/LLE categories with different dimensions and identified by designations, Contact Cap, contact Holder, support Cap and support Holder and 15 keys for contact Caps and contact Holders, also identified by designations. In the current Edition 1.1 of the Book 14, 9 keys for contact Caps and Holders are defined while the rest is reserved for future applications. Each LED Module/LLE category can be combined with each key. 2.3 Outline of this Book This Book 14 consists of two parts: Part 1, Interface Definition, defines the LED Module/LED Light Engine-Luminaire interface in terms of the five sub interfaces: The mechanical interface (section 3). The photometric interface (section 4). The electrical interface (section 5). The thermal interface (section 6). The control interface (section 7). Part 2, Compliance Tests, defines: Specific tools, which are used for testing compliance of a LED Module, LED Light Engine or a Luminaire (section 8). Zhaga Consortium, March 2017 9

Overview (Informative) The LED Module/LED Light Engine tests (section 9). The Luminaire tests (section 10). The Annexes to this Book 14 provide the following additional information: Requirements on the information that shall be part of the Product Data Sets (Annex A). History of changes (Annex B) Zhaga Consortium, March 2017 10

Part 1: Interface Definition Zhaga Consortium, March 2017 11

Mechanical interface 3 Mechanical interface 3.1 Drawing principles For the purpose of this section, the provisions in [Book 1] - section 3.1, apply. 3.2 Overview of the mechanical interface A Book 14 LED Module or LLE shall have one support Cap as defined in section 3.3.2 and one contact Cap as defined in section 3.3.3. For each LED Module or LLE to be mounted in a Book 14 Luminaire, the Luminaire shall have one support Holder as defined in section 3.4.2 and one contact Holder as defined in section 3.4.3. For each of the 3 LED Module/LLE categories Book 14 defines: The maximum outline of the LED Module or LED Light Engine (Section 3.3.1) Position of the support Cap and contact Cap in the LED Module and LLE (Section 3.3.1) Position of the support Holder and contact Holder in the Luminaire (Section 3.4.1) 3.3 Definition of the mechanical interface of the LED Module and LED Light Engine For the purpose of this section, the provisions in [Book 1] - section 3.3, apply. 3.3.1 Definition of Book 14 LED Modules or LLEs for different categories The mechanical dimensions of the Book 14 LED Module or LED Light Engine are defined in Figure 3-1. For each of the LED Module/LLE categories (L60W5, L120W5 and L150W5) the restrictions are listed in Table 3-1. W H D (3) (3) (2) (1) B E A F Figure 3-1: Mechanical dimensions of the Book 14 LED Module and LED Light Engines Notes to Figure 3-1: (1) is the reference plane of the contact Cap. This is the same reference plane as the reference plane (1) in Figure 3-3. (2) is the reference plane support Cap. This is the same reference plane as the reference plane (1) in Figure 3-2. (3) is an optional base of the cap. Dimensions E and F delineate the free space for insertion and withdrawal movement. Zhaga Consortium, March 2017 12

Mechanical interface Dimension LED Module/LLE category designation L60W5 L120W5 L150W5 Min. Max. Min. Max. Min. Max. A 553,0 555,0 1152,0 1156,0 1451,5 1456,0 B -- 6,0 -- 6,0 -- 6,0 D -- 565,0 -- 1166,0 -- 1466,0 W -- 50 -- 50 -- 50 H -- 35 -- 35 -- 35 E 7,3 -- 7,3 -- 7,3 -- F 3,7 -- 3,7 -- 3,7 -- Table 3-1: Values of dimensions for the Book 14 LED Modules and LED Light Engines Zhaga Consortium, March 2017 13

Mechanical interface 3.3.2 Definition of the support Cap The mechanical properties of the support Cap as defined in Figure 3-2 shall comply with the restrictions listed in Table 3-2. Figure 3-2: Mechanical dimensions of the support Cap Notes to Figure 3-2: (1) is the reference plane of the support Cap. This is the same reference plane as the reference plane (2) in Figure 3-1 and the reference plane (1) in Figure 3-6. The dashed line defined by the dimensions H, I, K, L and M is the demarcation between the space which may be occupied by parts of the LLE and the space which may be occupied by parts of the support Holder and Luminaire. The anchor shall be dimensioned sufficiently for maximum allowed lamp mass. Dimension Min. Max. A 11,6 11,8 B 6,3 6,5 C 4,7 5,1 G -- 4,5 H 17,0 I 11,0 K 3,0 L 23,6 M 0,5 Table 3-2: Values of dimensions for the support Cap Zhaga Consortium, March 2017 14

Mechanical interface 3.3.3 Definition of contact Caps The mechanical dimensions of the contact Cap as defined in Figure 3-3 shall comply with the restrictions listed in Table 3-3. By way of example dimensions are shown for key GR6d-1. The key-specific dimensions are defined in Figure 3-4. Figure 3-3: Mechanical dimensions of the contact Cap (Key GR6d-1 as example) Notes to Figure 3-3: (1) is the reference plane of the retention system. This is the same reference plane as the reference plane (1) in Figure 3-1 and the reference plane (1) in Figure 3-7. (2) is the reference plane of the fit system. This is the same reference plane as the reference plane (2) in Figure 3-7. The retention spring need to pass beyond level point U1 / R3 The dimensions R1, R2 and R3 define functional level points for retention spring function. The dimension K is the width of the guiding groove. The dashed line defined by the dimensions P, M, Q, Q1 and Q2 is the demarcation between the space which may be occupied by parts of the LLE and the space which may be occupied by parts of the contact Holder and Luminaire. The contacts are indicated by (7). The edges of the contacts should be chamfered or rounded. (9) indicates the polarity of the forward voltage (in DC operation) on the contacts of the contact cap. Zhaga Consortium, March 2017 15

Mechanical interface Dimension Min. Max. A 12 12,5 C 5,1 5,5 D 6,0 E1 2,8 3,2 E2 0,45 0,55 F1 1,9 2,3 G 6,2 6,7 H 4,8 5,2 I 4,2 -- J 0,9 1,3 K 0,9 -- L 12,3 12,8 M 4,8 O 2,5 3 P 6,1 Q 23,6 Q1 12,0 Q2 8,0 R1 1,2 -- R2 -- 1,1 R3 1,7 2 S -- 6,6 U -- 4,5 U1 0,7 -- U2 1,5 2,3 X 1,4 1,6 Y 1,1 1,3 Table 3-3: Values of dimensions for the contact Cap The key-specific dimensions of the contact caps are defined in Figure 3-4. Zhaga Consortium, March 2017 16

Mechanical interface Figure 3-4: Key specific dimensions of the contact Cap 3.3.4 Mass The mass of a Book 14 LED Module or LLE shall be less than or equal to 2,0 kg. Zhaga Consortium, March 2017 17

Mechanical interface 3.4 Definition of the mechanical interface of the Luminaire For the purpose of this section, the provisions in [Book 1] - section 3.3, apply. 3.4.1 Definition of Book 14 Luminaires for different categories For each LLE to be mounted in the Luminaire, the Luminaire shall provide a keep-out zone with dimensions L, W and H. The position of this keep-out zone with respect to the Holders and the distance between the Holders are defined in Figure 3-5. For each of the LLE categories (L60W5, L120W5 and L150W5) the restrictions are listed in Table 3-4. Figure 3-5: Mechanical dimensions of Book 14 luminaires Notes to Figure 3-5: (1) is the reference plane of the contact Holder. Dimension LED Module/LLE category designation L60W5 L120W5 L150W5 Min. Max. Min. Max. Min. Max. A1 550 552 1150 1152 1450 1452 H 35-35 - 35 - K 2,6-2,6-2,6 - L 565-1166 - 1466 - M 7,6 8,6 7,6 8,6 7,6 8,6 W 50-50 - 50 - Table 3-4: Values of dimensions for the Book 14 Luminaire Zhaga Consortium, March 2017 18

Mechanical interface 3.4.2 Definition of the support Holder The mechanical properties of the support Holder as defined in Figure 3-6 shall comply with the restrictions listed in Table 3-5. Notes to Figure 3-6: Figure 3-6: Mechanical dimensions of the support Holder (1) is the reference plane of the support Holder. This is the same reference plane as the reference plane (2) in Figure 3-1 and the reference plane (1) in Figure 3-2. The dashed line defined by the dimensions I, J, K, L and M is the demarcation between the space which may be occupied by parts of the LLE and the space which may be occupied by parts of the support Holder and Luminaire. Dimensions C1 and C2 define different force application plate / spring positions: C1 is the resting position without Cap inserted, C2 is the resting position with Cap inserted. Spring function for defined seating position. Zhaga Consortium, March 2017 19

Mechanical interface Dimension Min. Max. A 12,3 12,9 B 7,1 7,7 C1 -- 4,6 C2 5,1 -- G 6,2 6,8 H 7,6 8,6 I 11,0 J 17,0 K 3,0 L 23,6 M 0,5 Table 3-5: Values of dimensions for the support Holder Zhaga Consortium, March 2017 20

Mechanical interface 3.4.3 Definition of contact Holders The mechanical dimensions of the contact Holder as defined in Figure 3-7 shall comply with the restrictions listed in Table 3-6. By way of example dimensions are shown for key GR6d-1. The key-specific dimensions are defined in Figure 3-8. Figure 3-7: Mechanical dimensions of the contact Holder (Key GR6d-1 as example) Notes to Figure 3-7: (1) is the reference plane retention system. This is the same reference plane as the reference plane (1) in Figure 3-1 and the reference plane (1) in Figure 3-3. (2) is the reference plane fit system. This is the same reference plane as the reference plane (2) in Figure 3-3. Dimension V defines rotating axis of retention spring. The above spring solution is one example. Other designs are allowed provided that retention positions U and U2 as well as the reference position are reached. (4) is the retention spring The dimensions U and U2 define maximum retention spring movement. The dashed line defined by the dimensions P, M, Q, Q1 and Q2 is the demarcation between the space which may be occupied by parts of the LLE and the space which may be occupied by parts of the contact Holder and Luminaire. The dimensions S1, S2 and S3 define different force application plate positions: o S1 is resting position without Cap inserted, o S2 is resting position with Cap inserted, o S3 is maximum position during insertion and withdrawal. (11) indicates the forward voltage (in DC operation) on the contacts of the contact Holder in case. Zhaga Consortium, March 2017 21

Mechanical interface Dimension Min. Max. A 12,6 13,2 C 5,7 6,2 D 6,0 E1 3,3 3,7 E2 0,9 1,2 F1 1,5 2,5 F2 8,0 -- G 5,6 6,1 H 4,0 4,6 I 2,7 3,8 J -- 2,0 K 0,6 0,8 L 13,0 13,5 M 2,7 N -- 4,9 O 5,1 -- P 4,0 Q 23,6 Q1 12,0 Q2 8,0 S1 -- 2,0 S2 6,6 S3 8,7 -- U 4,8 U2 2,5 V 8,7 -- X 1,5 2,0 Y 1,5 2,0 r1 -- 0,5 r2 -- 1,0 r3 1 -- 1,0 Table 3-6: Values of dimensions for the contact Holder 1 This radius applies along the circumference of insert for the Holder Zhaga Consortium, March 2017 22

Mechanical interface The key-specific dimensions of the contact Holders are defined in Figure 3-8. Figure 3-8: Key specific dimensions of the contact Holder Zhaga Consortium, March 2017 23

Photometric interface 4 Photometric interface 4.1 Light Emitting Surface This edition of Book 14 of the does not contain requirements on the Light Emitting Surface of the LED Module or the LLE. 4.2 Operating conditions For the purpose of this section, the provisions in [Book 1] - section 4.2 apply, with the following exceptions: The requirement on tt rr does not apply. The ambient temperature of the LED Module or LLE and test fixture(s) shall be within the range 25 ± 1. 4.3 Luminous flux For the purpose of this section, the provisions in [Book 1] - section 4.3 apply. The luminous flux of the LED Module or the LED Light Engine shall be measured under the conditions specified in section 4.2. 4.4 Luminous intensity distribution This edition of the Book 14 of the does not contain requirements on the luminous intensity distribution of the LED Module or the LLE. 4.5 Luminance uniformity This edition of the Book 14 of the does not contain requirements on the Luminance uniformity of the LED Module or the LLE. 4.6 Correlated color temperature For the purpose of this section, the provisions in [Book 1] - section 4.6 apply. The correlated color temperature of the LED Module or the LED Light Engine shall be measured under the conditions specified in section 4.2. 4.7 Color rendering index For the purpose of this section, the provisions in [Book 1] - section 4.7 apply. The color rendering index of the LED Module or the LED Light Engine shall be measured under the conditions specified in section 4.2. Zhaga Consortium, March 2017 24

Electrical interface 5 Electrical interface 5.1 Electrical interface between LED Module and Luminaire In case of a Book 14 product being a LED Module or a Luminaire for a LED Module, the requirements in the following sub-sections apply. 5.1.1 Nominal input current and forward voltage The LED Module shall comply with the provisions of [LEDset-Pow]. The LED Module shall have a contact Cap with one of the keys: GR6d-1, GR6d-2, GR6d-3, GR6d-4 or GR6d- 5. The LED Module shall meet the requirements on electrical parameters corresponding to the key of the contact Cap as listed in Table 5-1. The polarity of the forward voltage shall be as indicated in Figure 3-3. Key Nominal input Current Forward voltage GR6d-1 350 ma 20V Vf 50V GR6d-2 500 ma 20V Vf 50V GR6d-3 700 ma 20V Vf 50V GR6d-4 1050 ma 20V Vf 50V GR6d-5 1400 ma 20V Vf 50V GR6d-6 reserved reserved GR6d-7 reserved reserved GR6d-8 reserved reserved GR6d-9 reserved reserved Table 5-1: Electrical input characteristics of the LED Module The Luminaire shall have a contact Holder with one of the keys: GR6d-1, GR6d-2, GR6d-3, GR6d-4 or GR6d- 5. The Luminaire shall meet the requirements on electrical parameters corresponding to the key of the contact Holder as listed in Table 5-2. The polarity of the forward voltage shall be as indicated in Figure 3-7. Key Nominal output Current Minimum voltage range GR6d-1 350 ma 20V... 50V GR6d-2 500 ma 20V... 50V GR6d-3 700 ma 20V... 50V GR6d-4 1050 ma 20V... 50V GR6d-5 1400 ma 20V... 50V GR6d-6 reserved reserved GR6d-7 reserved reserved GR6d-8 reserved reserved GR6d-9 reserved reserved Table 5-2: Electrical output characteristics of the Luminaire Zhaga Consortium, March 2017 25

Electrical interface 5.1.2 Electrical insulation The luminaire Contact Holder shall provide a SELV output as defined in [IEC60598-1] 2. 5.1.3 Hot plugging The current edition of this Book 14 does not require any functionality related to hot plugging. 5.2 Electrical interface between LLE and Luminaire In case of a Book 14 product being a LED Light Engine or a Luminaire for a LED Light Engine, the requirements in the following sub-sections apply. 5.2.1 Mains power The LLE shall have a contact Cap with one of the keys: GR6d-10, GR6d-11, GR6d-12 or GR6d-14. The LLE shall meet the requirements on electrical parameters corresponding to the key of the contact Cap as listed in Table 5-3. The Luminaire shall have a contact Holder with one of the keys: GR6d-10, GR6d-11, GR6d-12 or GR6d-14. The Luminaire shall meet the requirements on electrical parameters corresponding to the key of the contact Holder as listed in Table 5-3. Key Input voltage range 3 [V] Rated frequency [Hz] Max. Current (A) GR6d-10 100...127 50 or 60 2 GR6d-11 200...254 50 or 60 2 GR6d-12 250...288 50 or 60 2 GR6d-13 reserved GR6d-14 100 288 50 or 60 2 GR6d-15 reserved Table 5-3: Mains power characteristics of the LLE and the Luminaire 5.2.2 Electrical insulation For the purpose of this section, the provisions in [Book 1] - section 5.1 apply. 2 In North America a Class 2 output per UL 1310 is determined to meet this requirement. 3 This is the input voltage range in which the product shall function as specified. Zhaga Consortium, March 2017 26

Thermal interface 6 Thermal interface Book 14 LED Modules and LLEs are self-cooling and do not have an explicit thermal interface between LED Module/LLE and Luminaire. For this reason this book does not contain requirements with respect to the thermal interface. Zhaga Consortium, March 2017 27

Control interface 7 Control interface 7.1 Dimming (optional) If a LLE supports dimming functionality, such dimming functionality shall comply with the provisions of [NEMA SSL 7A]. Zhaga Consortium, March 2017 28

Control interface Part 2: Compliance Tests Zhaga Consortium, March 2017 29

Compliance test tools 8 Compliance test tools 8.1 LED Module/LED Light Engine test tools 8.1.1 Gauges for test of mechanical interface 8.1.1.1 GO gauge for checking the contact Cap The GO gauge for checking the contact Cap is defined in Figure 8-1 and Table 8-1. Figure 8-1: Mechanical dimensions Notes to Figure 8-1: An allowance of 0,1 mm is included to accommodate pin alignment errors. An allowance of 0,35 mm is included to accommodate pin spacing and alignment errors. Zhaga Consortium, March 2017 30

Compliance test tools Dimension Tolerance A 12,5 0/+ 0,02 B1 23,6-0,1/+ 0,1 B2 20,5-0,1/+ 0,1 B3 13,6-0,1/+ 0,1 C 5,5 0/+ 0,02 D 6,0-0,005/+ 0,005 E1 (1) 3,3 0/+ 0,01 E2 (2) 0,9 0/+ 0,01 G 6,2-0,02/0 H 4,5-0,02/0 J1 0,9-0,02/0 J2 6,0-0,1/+ 0,1 L1 14,4 0/+ 0,02 N1 12,7-0,1/+ 0,1 N2 4,7-0,1/+ 0,1 N3 9,8-0,02/0 R4 1,0-0,05/+ 0,05 T 0,5 x 45-0,05/+ 0,05 Table 8-1: Values of dimensions Zhaga Consortium, March 2017 31

Compliance test tools 8.1.1.2 GO gauge for checking the contact Cap retention path The GO gauge for checking the contact Cap retention path is defined in Figure 8-2 and Table 8-2. Figure 8-2: Mechanical dimensions Dimension Tolerance B4 22,0-0,1/+ 0,1 B5 2,0-0,1/+ 0,1 B6 8,0-0,1/+ 0,1 I 4,2 0/+ 0,02 K 0,9-0,02/0 N4 2,0-0,1/+ 0,1 N5 12-0,1/+ 0,1 Table 8-2: Values of dimensions Zhaga Consortium, March 2017 32

Compliance test tools 8.1.1.3 GO and NOTGO gauges for checking the contact position of the contact Cap The GO gauge for checking the contact position of the contact Cap are defined in Figure 8-3 and Table 8-3. The NOGO gauge for checking the contact position of the contact Cap are defined in Figure 8-4 and Table 8-3. Figure 8-3: Mechanical dimensions of the GO gauge Figure 8-4: Mechanical dimensions NOTGO gauge Zhaga Consortium, March 2017 33

Compliance test tools Dimension Tolerance B9 10-0,1/+ 0,1 F1 1,9 0/+ 0,02 F2 2,35-0,02/0 G1 6,1-0,05/+ 0,05 H1 4,7-0,05/+ 0,05 Z1 1,65-0,1/+ 0,1 Z2 1,0-0,1/+ 0,1 Table 8-3: Values of dimensions Zhaga Consortium, March 2017 34

Compliance test tools 8.1.1.4 GO and NOTGO gauges for checking the key dimensions of the contact Cap The GO and NOTGO gauges for checking the key dimensions of the contact Cap are defined in Figure 8-5 and Table 8-4. Figure 8-5: Mechanical dimensions Dimension Tolerance B7 10-0,1/+ 0,1 B8 5,5-0,1/+ 0,1 X 1,5 0/+ 0,02 Y1 1,1-0,02/0 Y2 1,3 0/+ 0,02 Table 8-4: Values of dimensions Zhaga Consortium, March 2017 35

Compliance test tools 8.1.1.5 GO and NOTGO gauges for checking the key of the contact Cap The GO and NOTGO gauges for checking the key of the contact Cap are defined in Figure 8-6 and Table 8-5. By way of example dimensions are shown for key GR6d-1. The key-specific dimensions are defined in Figure 8-7. Figure 8-6: Mechanical dimensions for GR6D-1 Dimension Tolerance B10 15-0,1/+ 0,1 B11 10-0,1/+ 0,1 B12 4,0-0,1/+ 0,1 B13 10,6-0,02/+ 0 B14 1,3 0/+ 0,02 B15 1,4 0/+ 0,02 N6 6-0,1/+ 0,1 N7 2,4-0,1/+ 0,1 X 1,4-0,02/+ 0 Y 1,4 0/+ 0,02 a 1,85-0,01/+ 0,01 b 3,7-0,01/+ 0,01 c 5,55-0,01/+ 0,01 d 7,4-0,01/+ 0,01 e 9,25-0,01/+ 0,01 f 11,1-0,01/+ 0,01 Table 8-5: Values of dimensions Zhaga Consortium, March 2017 36

Compliance test tools Figure 8-7: Mechanical dimensions for GR6D-1 until and with GR6D15 Zhaga Consortium, March 2017 37

Compliance test tools 8.1.1.6 GO and NOTGO gauges for checking the support Cap The GO and NOTGO gauges for checking the support Cap are defined in Figure 8-8 and Table 8-6. Figure 8-8: Mechanical dimensions Dimension Tolerance A1 12,0 0/+ 0,02 A2 11,55 0/+ 0,02 B1 6,8 0/+ 0,02 B2 6,25 0/+ 0,02 C 5,1 0/+ 0,02 K 2,6-0,02/0 T1 10,0-0,1/+ 0,1 T2 2,15 0/+ 0,02 W 23,6-0,02/0 Table 8-6: Values of dimensions 8.1.2 Test Fixture PETF (photometric and electrical) For each LED Module/LLE category, the Test Fixture PETF is an open Luminaire with appropriate holders according to the definition in section 3.4. Zhaga Consortium, March 2017 38

Compliance test tools 8.2 Luminaire test tools 8.2.1 Gauges for test of mechanical interface 8.2.1.1 GO gauge A for checking the contact Holder The GO gauge A for checking the contact Holder is defined in Figure 8-9 and Table 8-7. Figure 8-9: Mechanical dimensions Zhaga Consortium, March 2017 39

Compliance test tools Dimension Tolerance A 12,6 0/+ 0,02 A1 17,6-0,1/+ 0,1 C 5,7 0/+ 0,02 D 6,18-0,005/+ 0,005 E1 3,3-0,02/0 E2 0,8-0,02/0 F 2,4-0,02/0 G 6,2 0/+ 0,02 H 4,6-0,02/0 I 4,0 0/+ 0,02 K 2,0-0,1/+ 0,1 L 13,0-0,02/0 L1 18,0-0,1/+ 0,1 O 8,5-0,02/0 r1 1,0 0/+ 0,02 r2 3,5-0,1/+ 0,1 r3 0,3-0,1/+ 0,1 S1 12,0-0,02/0 T1 10,0 0/+ 0,02 W1 12,0-0,1/+ 0,1 Table 8-7: Values of dimensions Zhaga Consortium, March 2017 40

Compliance test tools 8.2.1.2 GO gauge B for checking the contact Holder The GO gauge B for checking the contact Holder is defined in Figure 8-10 and Table 8-8. Figure 8-10: Mechanical dimensions Zhaga Consortium, March 2017 41

Compliance test tools Dimension Tolerance A 12,6 0/+ 0,02 A1 17,6-0,1/+ 0,1 C 5,7 0/+ 0,02 D 5,82-0,005/+ 0,005 E1 3,3-0,02/0 E2 0,8-0,02/0 F 2,4-0,02/0 G 6,2 0/+ 0,02 H 4,6-0,02/0 I 4,0 0/+ 0,02 K 2,0-0,1/+ 0,1 L 13,0-0,02/0 L1 18,0-0,1/+ 0,1 O 8,5-0,02/0 r1 1,0 0/+ 0,02 r2 3,5-0,1/+ 0,1 r3 0,3-0,1/+ 0,1 S1 12,0-0,02/0 T1 10,0 0/+ 0,02 W1 12,0-0,1/+ 0,1 Table 8-8: Values of dimensions Zhaga Consortium, March 2017 42

Compliance test tools 8.2.1.3 NOTGO gauge for checking the contact Holder The NOTGO gauge for checking the contact Holder is defined in Figure 8-11 and Table 8-9. Figure 8-11: Mechanical dimensions Dimension Tolerance A3 13,2 0/+ 0,02 C1 5,7-0,1/+ 0,1 G2 6,2 0/+ 0,02 H2 10,8 0/+ 0,02 L3 13,6 0/+ 0,02 r4 1,0-0,02/0 S2 2,0-0,1/+ 0,1 T2 5,0 0/+ 0,02 W2 10,0-0,1/+ 0,1 Table 8-9: Values of dimensions Zhaga Consortium, March 2017 43

Compliance test tools 8.2.1.4 GO gauge for checking the key of the contact Holder The GO gauges for checking the key of the contact Holder is defined in Figure 8-12 and Table 8-10. By way of example dimensions are shown for key GR6d-1. The key-specific dimensions are defined in Figure 8-13. Figure 8-12: Mechanical dimensions for GR6d-1 Zhaga Consortium, March 2017 44

Compliance test tools Dimension Tolerance Remark A 12,6-0,02/0 B1 1,85-0,01/+ 0,01 B2 3,7-0,01/+ 0,01 B3 5,55-0,01/+ 0,01 C1 1,85-0,01/+ 0,01 C2 3,7-0,01/+ 0,01 C3 5,55-0,01/+ 0,01 D O 8,5-0,02/0 T 0,9-0,02/0 r 0,4-0,02/0 W X 1,5-0,02/0 Y 1,3-0,02/0 No restrictions No restrictions Table 8-10: Values of dimensions Figure 8-13: Mechanical dimensions for GR6D-1 until and with GR6D15 Zhaga Consortium, March 2017 45

Compliance test tools 8.2.1.5 NOTGO gauges for checking the key of the contact Holder The NOTGO gauges for checking the key the contact Holder is defined in Figure 8-14 and Table 8-11. By way of example dimensions are shown for key GR6d-1. The key-specific dimensions are defined in Figure 8-15. Figure 8-14: Mechanical dimensions for GR6d-1 Zhaga Consortium, March 2017 46

Compliance test tools Dimension Tolerance Remark B1 5,8-0,02/0 B2 7,65-0,02/0 B3 9,5-0,02/0 B4 11,35-0,02/0 B5 13,2-0,02/0 E1 3,7-0,1/+ 0,1 E2 5,55-0,1/+ 0,1 E3 7,4-0,1/+ 0,1 E4 9,25-0,1/+ 0,1 E5 11,1-0,1/+ 0,1 D O 5,0-0,1/+ 0,1 r 0,5-0,02/0 S2 2,0-0,1/+ 0,1 T 0,9-0,02/0 W X 1,5-0,02/0 Y 2,1 0/-0,02 No restrictions No restrictions Table 8-11: Values of dimensions Figure 8-15: Mechanical dimensions for GR6D-1 until and with GR6D15 Zhaga Consortium, March 2017 47

Compliance test tools 8.2.1.6 GO and NOTGO gauges for checking the support Holder The GO gauge for checking the support Holder is defined in Figure 8-16 and Table 8-12. The NOTGO gauge for checking the support Holder is defined in Figure 8-17 and Table 8-12. Figure 8-16: Mechanical dimensions of GO gauge Figure 8-17: Mechanical dimensions of NOTGO gauge Zhaga Consortium, March 2017 48

Compliance test tools Dimension Tolerance A1 12,8-0,02/0 A2 12,8-0,02/0 B1 7,2-0,02/0 B2 7,75-0,02/0 D1 5,2 0/+ 0,02 D2 5,2 0/+ 0,02 r 0,2-0,02/0 Table 8-12: Values of dimensions Zhaga Consortium, March 2017 49

LED Module/LED Light Engine Compliance Tests 9 LED Module/LED Light Engine Compliance Tests 9.1 LED Module/LED Light Engine mechanical interface tests 9.1.1 Test of the dimensions D, W, H and A of the LLE The purpose of this test is to verify the dimensions D, W, H, A and B as defined in Figure 3-1 and Table 3-1. 9.1.1.1 Test equipment This test should be conducted with a caliper. 9.1.1.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.1.3 Test procedure and pass criteria Determine the designation of the LLE category from the Product Data Set of the LLE under test. Find the corresponding restrictions for the dimensions D, W, H, A and B in Table 3-1. Measure the dimensions D, W, H, A and B The LLE passes if the measured values of the dimensions D, W, H, A and B are within the restrictions as defined in Table 3-1. 9.1.2 Test of the contact Cap of the LED Module or LLE The purpose of this test is to verify maximum Cap outline with respect to dimensions A, C, E1, E2, G, H, J and L1 (Figure 8-1) and the combined spacing and displacement of the contacts. 9.1.2.1 Test equipment This test should be conducted with the gauge as defined in section 8.1.1.1. 9.1.2.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.2.3 Test procedure and pass criteria It shall be possible to insert the Cap into gauge until the Cap is in contact with the gauge surface as defined in Figure 8-1. 9.1.3 Test of the retention path of the contact Cap of the LED Module or LLE The purpose of this test is to verify the minimum Cap retention path (see Figure 3-3) width I and depth K (Figure 8-2). 9.1.3.1 Test equipment This test should be conducted with the gauges as defined in section 8.1.1.2. 9.1.3.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.3.3 Test procedure and pass criteria It shall be possible to insert the pin of the gauge into the Cap until the Cap is in contact with the gauge surface X as defined in Figure 8-2. Moreover it shall be possible to move the pin of the gauge freely in the complete retention path. Zhaga Consortium, March 2017 50

LED Module/LED Light Engine Compliance Tests 9.1.4 Test of the contact position of the contact Cap of the LED Module or LLE The purpose of this test is to verify the minimum and maximum contact recess. 9.1.4.1 Test equipment This test should be conducted with the gauges as defined in section 8.1.1.3. 9.1.4.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.4.3 Test procedure and pass criteria This procedure shall be conducted for both contacts. When inserting the Go gauge into the contact cavity it shall be possible that the GO indicator touches all 3 edges of the cavity surface as defined in Figure 3-3. When inserting the Not Go gauge into the contact cavity it shall not be possible that the NOT GO indicator touches simultaneously all 3 edges of the cavity surface as defined in Figure 3-3. 9.1.5 Test of the key dimensions of the contact Cap of the LED Module or LLE The purpose of this test is to verify minimum and maximum key notch width dimension Y and maximum key height dimension X (Figure 8-5) of the contact Cap. 9.1.5.1 Test equipment This test should be conducted with the gauges as defined in section 8.1.1.4. 9.1.5.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.5.3 Test procedure and pass criteria It shall be possible to enter the key notch into the gauge GO end until the gauge touches the Cap surface. It shall not be possible to insert the gauge NOT GO end. 9.1.6 Test of the key of the contact Cap of the LED Module or LLE The purpose of this test is to verify combined key position and minimum key notch height X (Figure 8-6) of contact caps. 9.1.6.1 Test equipment This test should be conducted with the gauges as defined in section 8.1.1.5. 9.1.6.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.6.3 Test procedure and pass criteria It shall be possible to stick the gauge with the relevant key designation over the Cap cavity wall containing the key notches until surface X of the gauge is fully in contact with the Cap cavity wall. In this position the key notches shall be co-planar with or project beyond the gauge surface. Additionally when the gauge is fully inserted until it is in contact with the top of the cavity there shall be no gap between the top of the key notch and the gauge slot end. It shall not be possible to insert any of the gauges with a non-similar key designation over the Cap cavity wall. Zhaga Consortium, March 2017 51

LED Module/LED Light Engine Compliance Tests 9.1.7 Test of the support Cap of the LED Module or LLE The purpose of this test is to verify maximum support Cap outline and free space with respect to dimensions A, B, C, K and W and the maximum position from the Cap end T2 (Figure 8-8). 9.1.7.1 Test equipment This test should be conducted with the gauges as defined in section 8.1.1.6. 9.1.7.2 Test conditions This test shall be conducted at 25 ± 5. 9.1.7.3 Test procedure and pass criteria It shall be possible to fully insert the Cap into gauge 1 GO side from the outer Cap end. In this position the surface X of the gauge shall be co-planar with or project beyond the outer LED Module/LLE surface. Gauge 1 is then applied in turn with the NOT GO side. In this position it shall not be possible to fully insert the Cap. Additionally it shall not be possible to fully insert the Cap into gauge 2. 9.2 LED Module/LED Light Engine photometric interface tests 9.2.1 Test on luminous flux For the purpose of this section, the provisions in [Book 1] - section A.0.2.1 (for LED Module) or section A.1.2.1 (for LLE) apply. The Test Fixture PETF is defined in section 8.1.1.1. 9.2.2 Test on correlated color temperature (CCT) For the purpose of this section, the provisions in [Book 1] - section A.0.2.3 (for LED Module) or section A.1.2.3 (for LLE) apply. The Test Fixture PETF is defined in section 8.1.1.1. 9.2.3 A.1.2.4 Test on color rendering index For the purpose of this section, the provisions in [Book 1] - section A.0.2.4 (for LED Module) or section A.1.2.4 (for LLE) apply. The Test Fixture PETF is defined in section 8.1.1.1. 9.3 LED Light Engine Electrical interface tests In case of a Book 14 product being a LED Light Engine, no the compliance tests on the electrical interface need to be performed. Note that the electrical interface is implicitly tested by performing the photometric tests as defined in section 9.2. 9.4 LED Module Electrical interface tests In case of a Book 14 product being a LED Module, the compliance test in this section shall be performed. Note that the input current is implicitly tested by performing the photometric tests as defined in section 9.2. 9.4.1.1 Test equipment Adjustable current source and voltage meter. 9.4.1.2 Test conditions This test shall be conducted at 25 ± 5. Zhaga Consortium, March 2017 52

LED Module/LED Light Engine Compliance Tests 9.4.1.3 Test procedure and pass criteria Check the key of the Cap of the LED Module under test and find the corresponding input current and forward voltage range in Table 5-1. Apply the nominal current corresponding to the key to the LED Module under test and measure the forward voltage. Check whether the measured forward voltage is within the range as specified in Table 5-1. 9.5 LED Module/LED Light Engine thermal interface tests This edition of Book 14 of the does not contain compliance tests for the Thermal interface of the LED Module or the LLE. 9.6 LED Light Engine control interface tests 9.6.1 Test of dimming functionality The purpose of this test is to verify the dimming functionality of the LLE under test. This test applies only to LLEs and only if the data sheet of the LLE under test indicates that dimming functionality is supported. 9.6.1.1 Test equipment See [NEMA SSL 7A] Section 4. 9.6.1.2 Test conditions See [NEMA SSL 7A] Section 4. 9.6.1.3 Test procedure See [NEMA SSL 7A] Section 4. 9.6.1.4 Test procedure The Socketable LLE under test passes if all tests defined in [NEMA SSL 7A] Section 4 pass. 9.7 LED Module/LED Light Engine Product Data Set test For the purpose of this section, the provisions in [Book 1] - section A.0.5 (for LED Module) or section A.1.6 (For LLE) apply. Zhaga Consortium, March 2017 53

Luminaire compliance tests 10 Luminaire compliance tests 10.1 Luminaire mechanical interface tests 10.1.1 Test of the dimensions L, W, H and A1 of the Luminaire The purpose of this test is to verify the dimensions L, W, H, M and A1 as defined in defined in Figure 3-5 and Table 3-4. 10.1.1.1 Test equipment This test should be conducted with a caliper. 10.1.1.2 Test conditions This test shall be conducted at 25 ± 5. 10.1.1.3 Test procedure and pass criteria This test shall be performed for each LLE position in the Luminaire. Determine the designation of the LLE category from the Product Data Set of the Luminaire under test. Find the corresponding restrictions for the dimensions L, W, H, M and A1 in Table 3-4. Measure the dimensions L, W, H, M and A1 The Luminaire passes if the measured values of the dimensions L, W, H, M and A1 are within the restrictions as defined in Table 3-4. 10.1.2 Test of the contact Holder of the Luminaire part 1 The purpose of this test is to verify contact Holders for a proper acceptance of maximum caps at maximum pin distance in the following respects: height and width A, C, G, H, L, O, and T1 (Figure 8-9) free space and position for retention system I, K and S1 (Figure 8-9) 10.1.2.1 Test equipment This test should be conducted with the gauge as defined in section 8.2.1.1. 10.1.2.2 Test conditions This test shall be conducted at 25 ± 5. 10.1.2.3 Test procedure and pass criteria It shall be possible to insert the gauge into the contact Holder until the gauge is in contact with the surface of the contact Holder. 10.1.3 Test of the contact Holder of the Luminaire part 2 The purpose of this test is to verify contact Holders for a proper acceptance of maximum caps at minimum pin distance in the following respects: height and width A, C, G, H, L, O, and T1 (Figure 8-10) free space and position for retention system I, K and S1 (Figure 8-10) 10.1.3.1 Test equipment This test should be conducted with the gauge as defined in section 8.2.1.2. Zhaga Consortium, March 2017 54