Pressure Display Controller

Similar documents
Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

W 30 Photoelectric proximity switches: Clear signals even with low remission

ED 701 General Industry Pressure Transmitter

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER


PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

American Zettler AZ742 RELAY Datasheet

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

BLC Series - Basic Compact Pressure Sensor Series. Introduction

Standards and Certifications. File # E37317, E65657 File # LR217017, LR217069

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

W250: Compact photoelectric switch series for a broad range of applications

General Purpose Relays Types K, R, N, and C

Fitting PS P - B - R2

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

E8EB-N0C2B E8EB-N0B2B

Operating Instructions for Digital Manometer. Model: MAN-SD

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Thermal-Magnetic Circuit Breaker 2210-S2..

PHOENIX CONTACT - 04/2016. Features

Resistivity and Temperature Coefficients (at 20 C)

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Safety Barriers Series 9001, 9002 Standard Applications

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Indicate Positive, Negative or Differential, Accurate within 1%

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Thermal-Magnetic Circuit Breaker 2210-S2..

Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DETAIL "A" #110 TAB (8 PLACES) X (4 PLACES) Y (3 PLACES) TH1 TH2 F O 1 F O 2 DETAIL "A"

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

all stainless steel transducer multimedia compatibility

Analogue Meters CQ2x07 series

Thermal-Magnetic Circuit Breaker 2210-S2..

T C MEASURED POINT G1 E1 E2 G2 W - (4 PLACES) G2 E2 E1 G1

Field IT 50T Series Transmitters

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

W 34: Sensor technology that does justice to demanding requirements

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

CTC 155 / 350 / 660 Dry-block calibrator

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

Freescale Semiconductor

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Harnessing the Power of Arduino for the Advanced Lab

V 12: Miniature photoelectric switches in M 12 housings

5730A High Performance Multifunction Calibrator. Extended specifications

Pressure transmitters for industrial applications MBS 32 and MBS 33

Electric Deflection of Electrons

CM200EXS-24S. Chopper IGBT NX-Series Module 200 Amperes/1200 Volts

C N V (4TYP) U (5TYP) Dimensions Inches Millimeters L 0.69± ±0.25 M N P Q

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

CM1000DUC-34SA. Mega Power Dual IGBT 1000 Amperes/1700 Volts

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

DIGITAL THERMOMETER OPERATOR S MANUAL

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

PG-200/PG-208 PRESSURE GAUGES P G G P P

PRODUCT CATALOGUE PREssURE switch

SSi Super Systems Inc.

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

US06CPHY06 Instrumentation and Sensors UNIT 2 Part 2 Pressure Measurements

L K K K K P P1 N GU EU GV EV GW EW GU GVGW GB E LABEL H H

Series CCT-58S Multi-Throw DC 18 GHz, SP7T & SP8T Normally Open Coaxial Switch

ORDERING INFORMATION # of Ports Pressure Type Device Name

Pressure Transmitter ED 701

Pressure Measurement Single-range transmitters for general applications

5SJ4...-.HG Circuit Breakers to IEC and UL 489

24 volts (0.25 amps current-limited)

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

C N V (4TYP) U (5TYP)

Non-Contact Safety Systems CMS

General Purpose Transistors

ISEmax CAM40/CAS40. Technical Information

792A AC/DC Transfer Standard

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

792A AC/DC Transfer Standard

DIN Timers TD. Options and ordering codes. Specification

Transcription:

MODEL DW Display Controller Low The Model DW pressure controller accurately monitors and controls very low pressures. It combines in one enclosure a low pressure transducer, a digital display and two alarms (see Fig. 1). This pressure controller has a threestate output: a high pressure alarm when the pressure exceeds a high limit, a low pressure alarm when the pressure falls below a low limit, and no output when the pressure is within these limits. It is typically used for the monitoring and control of pressure in closed areas such as rooms and buildings. Fig. 1 Block Diagram DESCRIPTION The pressure sensing element is a differential capacitance cell for pressure measurements ranging from 0.1 to inches of water (25 Pa to 1.0 kpa), or a piezoresistive (silicon) sensor for pressures from 5 inches of water to 30 PSI (1.0 kpa to 200 kpa). The display section has 3 1/2 digits with bright, easy to read LEDs. The display is factorycalibrated to read in engineering units. The alarm section is offered with 2 alarms. Each alarm may be ordered with a relay, or transistor output. On the front panel are three multiturn potentiometers and three pushbuttons. Momentarily pressing a pushbutton displays the corresponding potentiometer setting (see Fig. 2). Fig. 2 Front panel of controller Potentiometer 1 sets the desired control pressure (setpoint). Potentiometer 2 controls the range (or the ± deviation from the setpoint). value is 1/2 the range. Potentiometer 3 controls the deadband. This is the pressure change required to turn the high or low alarm OFF when the controlled pressure is moving toward the setpoint after reaching the upper or lower limit (see fig. 3). Barb fittings and pluggable terminals with screw clamps are provided at the rear for quick and simple field connections. SPECIFICATIONS Accuracy of reading: Standard ±1% of span +1 digit (including nonlinearity & hysteresis) Setpoint accuracy: ±0.2% of span + 1 digit (including repeatability) Power requirements: 21 32 Vac 50/60 Hz, 105135 Vac 50/60 Hz or 210265 Vac 50/60 Hz Power consumption: 2.5 VA Electrical connections: Noninterchangeable power and alarm plugs with #440 screw clamps; wire range is 1422 AWG Warmup time: 5 minutes to rated accuracy Transmitter Measures differential gage pressure or vacuum Medium: Air or inert gases Standard pressure ranges: See reference table D safe momentary overpressure: See reference table D Zero & span adjustments: 15turn potentiometers accessible behind red front filter Port connections: 3/16" (4.75 mm) Dia. suitable for 1/8" or 5/32" I.D. Tygon or polyurethane tubing; 1/4"O.D. polyethylene tubing Air filter at both ports Display Display: 3 1/2 digits 7 segments orangered LEDs 0.56"(14.2 mm) high decimal point factoryprogrammable to 4 positions ( 1.8.8.8. ) Conversion rate: 3 readings/sec Polarity: Automatic, no positive sign, "" negative sign Overrange indication: Beyond 1999 display shows "1" Zero & span adjustments: 15turn potentiometers accessible behind red front filter 16 Modus Instruments, Inc. Tel. 800 225 3208 Fax 781 938 1071 Web www.geinet.com

Alarms Number of alarms: 2 alarms Setpoint range & deadband adjustments: 15turn potentiometers accessible through holes in front filter (see fig.2) Setpoint range or deadband display: by pressing momentary pushbutton in front of controller (see fig.2) Setpoint adjustment: from 0 to 100% of span 1/2 range adjustment: from 1% to 33% of span Deadband adjustment: from 0 to 33% of span Output: each alarm is available with either: A. SPDT (1 form C) electromechanical relay; contacts rated at 3A 30V DC or 120V AC, or 4A at 240V AC resistive Contact material is gold overlay Isolation between contacts and coil is 2000 Vrms minimum. B. Transistor (NPN with open collector) rated at: 40 Vdc offstate voltage 120 madc onstate current when using an external power supply 40 ma per alarm when using the internal 5 Vdc supply (consult factory for higher currents) 0.4 V saturation voltage at 100 ma Internal diode to absorb transients when the internal 5 Vdc supply is connected to inductive loads Environmental Operating temperature: 0 C to 52 C (32 F to 125 F) Storage temperature: 40 C to 85 C (40 F to 185 F) Relative humidity: 10% to 90% R.H. noncondensing Effect of temperature: ±0.05%/ C reading ±0.01%/ C setpoint Physical Dimensions: 1/8 DIN case (see drawing) Case material: glass reinforced NORYL rated UL94V1 Weight: 1.0 Lb (465 g) ORDERING INFORMATION Order Number (See Table below and Reference Table D on page 27) DW PS IP O AO EXAMPLE: DW 1 0 TFTR00 PS = Power Supply 1 = 120 Vac 2 = 240 Vac 3 = 24 Vac IP = Input See Table D for English or metric, or Table E for English or metric velocity (square root outputs) O = Offset Offsets are not available. Enter "0", no offset. AO = Alarm Output (See Notes) RFRR00 = Electro mechanical relay TFTR00 = Transistor, NPN with open collector NOTES Alarm Outputs RFRR00 Electromechanical relay TFTR00 Transistor, NPN with open collector (specify if external power supplied is used). Alarm 1 is configured to energize on falling pressure and alarm 2 on rising pressure (alarm 3 is not used). When ordering a Model DW controller, supply the following three fields: power supply, input pressure and alarm outputs. A typical part number may look as follows: DW10TFTR00 WIRING DIAGRAMS Fig.5 Rear panel connections. Figure 5 is a view of the rear panel of the controller with the high and low pressure ports, the power receptacle J1 (with terminals labeled A & B) and the alarm output receptacle J3 (with terminals labeled 1 through 9). Fig.6 Relay output. Figure 6 shows the internal wiring of the electromechanical relay. This type of output will switch small loads such as pilot lights or audible alarms. Also, the gold contacts offer a reliable output when a contact closure must be sensed and the current is very low. Fig.7 Transistor output, internal power supply. Figure 7 is a wiring diagram of the transistor output connected to a solidstate relay. The input voltage range of the relay is 3 to 32 Vdc. Power is supplied by the internal 5 Vdc supply of the controller. If an inductive load is connected, the internal diode will protect the transistor against transients. Fig.8 Transistor output, external power supply. Figure 8 shows the transistor controlling a load powered by an external 12 or 24 Vdc supply. The internal diode has been removed and an external diode or other means of limiting transients to 40 Volts must be added if the load is inductive. The current must not exceed 120 ma. 17 Modus Instruments, Inc. Tel. 800 225 3208 Fax 781 938 1071 Web www.geinet.com

TABLE A STANDARD PRESSURE RANGES 03E 07E 12E 13E 14E 19E 20E ENGLISH Range English 00.100 in. H 2 0 00.200 in. H 2 0 00.300 in. H 2 0 00. in. H 2 0 01.00 in. H 2 0 02.00 in. H 2 0 0 in. H 2 0 0 in. H 2 0 010.0 in. H 2 0 020.0 in. H 2 0 030.0 in. H 2 0 0 in. H 2 0 0100 in. H 2 0 01.00 psid 02.00 psid 0 psid 0 psid 015.0 psid 030.0 psid 5 in. H 2 0 20 in. H 2 0 1 30 psid 60 psid 03P 07P 12P Range 0 Pa 0 Pa 075.0 Pa 0 Pa 0 Pa 0 Pa 0750 Pa 01.00 kpa 0 kpa 0 kpa 07.50 kpa 010.0 kpa 0 kpa 0 kpa 0 0200 kpa TABLE B STANDARD PRESSURE RANGES FOR W SERIES 31E 32E 33E 34E 35E 36E 37E 38E ENGLISH UNITS Range, psid 06 psid 010 psid 01 030 psid 060 psid 0100 psid 0150 psid 0200 psid Operating Static, psi 0100 psi* 0 300 psi* 31P 32P 33P 34P 35P 36P 37P 38P Range, kpa 050 kpa 075 kpa 0 0200 kpa 0 kpa 0750 kpa 01000 kpa 01 kpa * safe momentary overpressure at any port is 2X the maximum operating static pressure TABLE C STANDARD PRESSURE RANGES FOR MANOMETER 03E 07E 12E 13E 14E Range 00.100 in. H 2 0 00.200 in. H 2 0 00.300 in. H 2 0 00. in. H 2 0 01.00 in. H 2 0 02.00 in. H 2 0 0 in. H 2 0 0 in. H 2 0 010.0 in. H 2 0 020.0 in. H 2 0 030.0 in. H 2 0 0 in. H 2 0 0100 in. H 2 0 01.00 psid 02.00 psid 0 psid 0 psid ENGLISH.100.200.300. 30.0 5 in H 2 0 2H 2 0 03P 07P 12P Range 0 Pa 0 Pa 075.0 Pa 0 0 Pa 0 Pa 0750 Pa 01.00 kpa 0 kpa 0 kpa 07.50 kpa 010.0 kpa 0 kpa 0 kpa 0 0200 kpa 75.0 750 7.50 199.9 5 kpa 200 kpa 400 kpa Operating Static, psi 0 700 kpa* 0 2000 kpa* 5 kpa 03M 07M 12M 31M 32M 33M 34M 35M 36M 37M 38M 03M 07M 12M Range 0 mm H 2 0 0 mm H 2 0 07.50 mm H 2 0 0 mm H 2 0 0 mm H 2 0 0 mm H 2 0 075.0 mm H 2 0 0100 mm H 2 0 0 mm H 2 0 0 H 2 0 0750 mm H 2 0 01.00 m H 2 0 02.5 m H 2 0 05.0 m H 2 0 010.0 m H 2 0 020.0 m H 2 0 Range, k mm H 2 0 05.0 k mm H 2 0 07.5 k mm H 2 0 010 k mm H 2 0 020 k mm H 2 0 050 k mm H 2 0 075 k mm H 2 0 0100 k mm H 2 0 0150 k mm H 2 0 Range mm of H 2 O 0 mm 0 mm 07.50 mm 010.0 mm 0 mm 0 mm 075.0 mm 0100 mm 0 mm 0 0750 mm 01.00 m 0 m 0 m 010.0 m 020.0 m 20 m 40 m Operating Static k mm H 2 0 070 k mm H 2 0 0200 k mm H 2 0 7.50 10.0 75.0 750

TABLE D STANDARD PRESSURE RANGES English (1) Range (2) 19E 20E **E 00.1 in. H 2 0 00.2 in. H 2 0 00.5 in. H 2 0 01.0 in. H 2 0 02.0 in. H 2 0 0 010.0 in. H 2 0 020.0in. H 2 0 01 psid 02 psid 03 psid 0 01 030 psid.100.200. 1 30.0 psid psid psid psid psid 0.1 psid 20.0 20.0 1 1 1 1 30 psid 60 psid Metric, millimeters of water (1) Range (2) **M 0 mm H 2 0 0 010.0 0 0 0100 0 0 01.00 meter 0 meter 0 meter 010.0 meter 020.0 meter 1.0 mm 1.0 mm.001 meter 20 m 40 m Metric, pascals (1) Range (2) **P 025 Pa 050 Pa 0 0 Pa 0 Pa 01.0 kpa 02.5 kpa 05.0 kpa 010 kpa 025 kpa 050 kpa 0 0200 kpa 199.9 5.0 kpa 5.0 kpa 200 kpa 400 kpa (1) Use this code when ordering. (2) This column shows the number of digits that are displayed and the position of the decimal point.

TABLE E Velocity Ranges, feet per minute (1) Range Velocity Range (2) capacitance cell 01F 02F 04F 05F 06F 08F 09F **F 00.1 in. H 2 0 00.2 in. H 2 0 00.5 in. H 2 0 01.0 in. H 2 0 02.0 in. H 2 0 0 010.0 in. H 2 0 90 1266 fpm 125 1791 fpm 200 2832 fpm 280 4005 fpm 400 5664 fpm 4625 8955 fpm 885 12665 fpm 1.27 1.80 2.83 4.00 5.66 8.96 12.7 Contact factory for other pressure or velocity ranges, displayed units and resolution 100 fpm 20.0 in. H 2 0 20.0 in. H 2 0 in. H 2 0 in. H 2 0 1. Use this code when ordering. 2. The velocities are accurate for dry air at standard conditions (air density of 0.075 lb/ft 3, barometric pressure of 29.92 inches of mercury and temperature of 70 F). It is also assumed that standard pitot tubes similar to those described in the accessory bulletin are used. The velocities are derived from the following formula: V = 4005 H v Where: V is air velocity in feet per minute H v is velocity pressure in inches of water Velocity Ranges, meters per second (1) Range Velocity Range (2) capacitance cell 01V 02V 04V 05V 06V 08V 09V **V 02.5 mm H 2 0 05.0 mm H 2 0 010.0 mm H 2 0 0 mm H 2 0 0 mm H 2 0 0100 mm H 2 0 0 mm H 2 0 0.45 6.4 m/s 0.639 m/s 0.90 13 m/s 1.4 20 m/s 2.0 29 m/s 2.8 40 m/s 4.5 64 m/s 6.50 9.00 13.0 20.0 29.0 40.0 64.0 Contact factory for other pressure or velocity ranges, displayed units and resolution 0.01 m/s 0.01 m/s 1 mm 1 mm 1. Use this code when ordering. 2. The velocities are accurate for dry air at standard conditions (air density of 1.201 kg/m 3, barometric pressure of 760 mm of mercury and temperature of 21 C). It is also assumed that standard pitot tubes similar to those described in the accessory bulletin are used. The velocities are derived from the following formula: V = 4.037 H v Where: V is air velocity in meters per second H v is velocity pressure in millimeters of water