SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ACCREDITED LABORATORY. INSPECTION MEASUREMENT COMPANY Wyoming, MI

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation to ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

A2LA. G118: Guidance for Defining the Scope of Accreditation for Calibration Laboratories

CALIBRATION CERTIFICATE # 503

For the National Voluntary Laboratory Accreditation Program

CERTIFICATE OF ACCREDITATION

For the National Voluntary Laboratory Accreditation Program

Scope of Accreditation For ISOLAB Inc. Calibration

CERTIFICATE OF ACCREDITATION

Uncertainty Propagation for Force Calibration Systems

P103d Annex: Policy on Estimating Measurement Uncertainty for Construction Materials & Geotechnical Testing Labs Date of Issue 09/13/05

Document No: TR 12 Issue No: 1

Calibration Traceability Guidelines

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION

For the National Voluntary Laboratory Accreditation Program

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

台灣黑馬牌校正器類 CALIBRATOR METROLOGY

Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate 1

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CALIBRATION REPORT FOR THERMOHYDROMETER

R SANAS Page 1 of 7

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

Vocabulary of Metrology

Maha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352

New Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018

An Introduction to the Differences Between the Two Most Recognized Force Standards

Mason Technology Ltd

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

Measurement Uncertainty in Mechanical Testing

Mason Technology Ltd

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CEEN 3320 Behavior & Properties of Engineering Materials Laboratory Experiment No. 1 Measurement Techniques

CERTIFICATE OF CALIBRATION

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

ACCREDITED CALIBRATION AND MEASUREMENT CAPABILITY SCOPE. Ring gaugeф(50~100)mm U=1.1 μm

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

MEASUREMENT UNCERTAINTY PREPARED FOR ENAO ASSESSOR CALIBRATION COURSE OCTOBER/NOVEMBER Prepared by MJ Mc Nerney for ENAO Assessor Calibration

MOY/SCMI/36 SPECIFICATION OF ACCURACY FOR A PRECISION CLINOMETER

MEASUREMENT TRACEABILITY AND ERRORS RELATED TO FORCE MEASUREMENT

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Torque Measuring Devices

Probability & Statistics: Introduction. Robert Leishman Mark Colton ME 363 Spring 2011

Designation: NWI DIF Horizontal Hail impact Standard

Balancing with an Offset Mass Center

Infrared Thermometer Calibration A Complete Guide

Transcription:

PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard: ISO/IEC 17025:2005 This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (as outlined by the joint ISO-ILAC-IAF Communiqué dated January 2009): Calibration of Industrial Scales, Vehicle Scales, Balances, Test Weights, Dimensional, and Mechanical Devices (As detailed in the supplement) Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation body s duty to observe and comply with the said rules. For PJLA: Initial Accreditation Date: Issue Date: Expiration Date: June 18, 2010 February 28, 2017 February 28, 2019 Tracy Szerszen President/Operations Manager Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084 Accreditation No.: Certificate No.: 63075 L17-59 The validity of this certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website: www.pjlabs.com Page 1 of 5

Dimensional Certificate of Accreditation: Supplement AND Caliper FO 1 in to 3 in (640 + 1L) µin Grade B890 Gage Blocks 4 in to 12 in (609 + 8L) µin Length Standards 13 in to 24 in (652 + 4L ) µin T.O. 33K6-4-15-1 Micrometer FO 1 in to 3 in (60 + 4L) µin 4 in to 12 in (119 + 3L) µin 13 in to 24 in (130 + 2L ) µin Indicators (Digital & Dial) FO 0.25 in to 3 in (128 + 6L) µin Grade B890 Gage Blocks T.O. 33K6-4-889-1 Height Gage FO 4 in to 12 in (610 + 8L) µin Grade B890 Gage Blocks 13 in to 24 in (653 + 4L) µin Height Gage Riser Block T.O. 33K6-4-673-1 Length Standard FO 1 in to 12 in (75 + 1.5L) µin Height Master 12 in to 24 in (67 + 2L) µin Riser Block T.O. 33K6-4-369-1 10 in 160 µin Length Standards Axis Linearity Chart Angularity Axial Squareness Magnification (maximum) 0 to 90 0.1 3 in of Y Axis Travel 0.02 (maximum Y axis travel if maximum is < 3 in) 10 X 0.02 % 20 X 0.01 % 31.25 X 50 X AND Angle Blocks Steel Square Mag Checking Scale Steel Balls OEM Analytical Balance FO 0.001 g to 200 g (1.2 x 10-3 + 6.81 x 10-7 Wt) g ASTM Class 1 Precision Balance FO 0.001 g to 5 000 g (1.2 x 10-3 + 5.55 x 10-6 Wt) g Issue: 02/2017 This supplement is in conjunction with certificate #L17-59 Page 2 of 5

AND High Capacity Precision 0.1 g to 75 kg (1.16 x 10-1 + 1.14 x 10-4 Wt) g NIST Class F Balance FO Scales Class FO 0.001 lb to 20 000 lb (1.2 x 10-3 + 1.15 x 10-4 Wt) lb 0.001 g to 10 000 kg (1.2 x 10-3 + 1.15 x 10-4 Wt) lb Vehicle Scales FO 20 lb to 400 000 lb (23.1 + 7.14 x 10-5 Wt) lb Rail Scales FO 50 lb to 400 000 lb (57.73 + 4.05 x 10-5 Wt) lb Handbook 105-1 (lb) Handbook 105-1 (kg) 0.005 lb 0.22 mg ASTM E617 Class 1 Weights 0.01 lb ASTM E617 Class 4 Weights Echelon III Mass 0.02 lb NIST IR 6969 SOP 8 0.03 lb 0.05 lb 0.1 lb 0.2 lb 0.3 lb 0.5 lb 2.2 mg 1 lb 2 lb 5 lb 10 lb 20 lb 2.9 mg 25 lb 0.15 g 50 lb 2 g 0.22 mg 3 g 5 g 10 g 20 g 30 g 50 g 100 g 200 g 300 g 2 mg Issue: 02/2017 This supplement is in conjunction with certificate #L17-59 Page 3 of 5

Handbook 105-1 (kg) DEVICE SIZE AS AND 500 g 2.2 mg ASTM E617 Class 1 Weights 1 kg ASTM E617 Class 4 Weights Echelon III Mass 2 kg NIST IR 6969 SOP 8 5 kg 10 kg 2.9 mg 20 kg 0.15 g 25 kg Mechanical AND Durometer Spring Type A FO Durometer Spring 200 g to 800 g 800 g to 5 000 g (1.16 x 10-1 + 3.20 x 10-9 Wt) g (1.15 x 10-1 + 1.96 x 10-7 Wt) g ASTM Class 1 Grade B89 Gage Blocks Type D FO Extension at Zero FO 0.097 in to 0.1 in 710 µin Torque Tool FO 3 lbf in to 30 lbf in 2.5 % of reading Torque Meter 10 lbf in to 100 lbf in 8 % of reading T.O. 33K6-4-2193-1 Indirect Verification of 10 HRBW to 50 HRBW 0.54 HRBW Test Block Rockwell Hardness 51 HRBW to 70 HRBW 0.51 HRBW ASTM E18 Testers HRBW & HRC O > 80 HRBW 0.5 HRBW 20 HRC to 39 HRC 0.37 HRC 40 HRC to 59 HRC 0.46 HRC > 60 HRC 0.19 HRC 1. The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of accreditation represents the smallest measurement uncertainty attainable by the laboratory when performing a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is typically expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual measurement uncertainty associated with a specific calibration performed by the laboratory will typically be larger than the CMC for the same calibration since capability and performance of the device being calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to some degree. Issue: 02/2017 This supplement is in conjunction with certificate #L17-59 Page 4 of 5

2. The laboratories range of calibration capability for all disciplines for which they are accredited is the interval from the smallest calibrated standard to the largest calibrated standard used in performing the calibration. The low end of this range must be an attainable value for which the laboratory has or has access to the standard referenced. Verification of an indicated value of zero in the absence of a standard is common practice in the procedure for many calibrations but by its definition it does not constitute calibration of zero capacity. 3. The presence of a superscript F means that the laboratory performs calibration of the indicated parameter at its fixed location. Example: Outside Micrometer F would mean that the laboratory performs this calibration at its fixed location. 4. The presence of a superscript O means that the laboratory performs calibration of the indicated parameter onsite at customer locations. Example: Outside Micrometer O would mean that the laboratory performs this calibration onsite at the customer s location. 5. The presence of a superscript FO means that the laboratory performs calibration of the indicated parameter both at its fixed location and onsite at customer locations. Example: Outside Micrometer FO would mean that the laboratory performs this calibration at its fixed location and onsite at customer locations. 6. Measurement uncertainties obtained for calibrations performed at customer sites can be expected to be larger than the measurement uncertainties obtained at the laboratories fixed location for similar calibrations. This is due to the effects of transportation of the standards and equipment and upon environmental conditions at the customer site which are typically not controlled as closely as at the laboratories fixed location. 7. The term L represents length in inches or millimeters as appropriate to the uncertainty statement. 8. The term Wt represents weight in pounds or grams (including SI multiple and submultiple units) appropriate to the uncertainty statement. 9. The term X proceeded by a number represents the number of times a lense system magnifies an image relative to its actual size. CMC stated as % of magnification represents the CMC of magnification expressed as a percentage of the total magnification. Issue: 02/2017 This supplement is in conjunction with certificate #L17-59 Page 5 of 5