PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Similar documents
ED 701 General Industry Pressure Transmitter

E8EB-N0C2B E8EB-N0B2B

PG-200/PG-208 PRESSURE GAUGES P G G P P

Fitting PS P - B - R2

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

PHOENIX CONTACT - 04/2016. Features

Pressure. 1 Fitting PA R - N R2

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Pressure Transmitter ED 701

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Operating Instructions for Digital Manometer. Model: MAN-SD

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Field IT 50T Series Transmitters

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Operating instructions Pressure sensor PN / / 2007

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure transmitters for industrial applications MBS 32 and MBS 33

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Thermal-Magnetic Circuit Breaker 2210-S2..

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Solenoid valves Type EVUL

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Direct-operated 2/2-way solenoid valves Type EV210B

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Thermal-Magnetic Circuit Breaker 2210-T2...

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Installation guide 862 MIT / MIR

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

5SJ4...-.HG Circuit Breakers to IEC and UL 489

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Thermal-Magnetic Circuit Breaker 2210-S2..

INFRARED THERMOMETER Model : TM-959

Electromagnetic Flowmeter

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

CS Series. Capacitance Type. Type. Proximity Sensor. Features

Thermal-Magnetic Circuit Breaker 2210-S2..

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Surface-mounting Thermostats ATH Type Series

Pressure Measurement Single-range transmitters for general applications

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

EMI Suppression PCRC 420 film capacitors (RC unit)

K04 TYPE -40 C +85 C 20000H

Type Plunger Height x pitch Operating force (OF) Without ground terminal Flat type 4.3 x 6.5 mm General 0.98 N (100 gf) B3F-6000 B3F-6100

Relative pressure transmitter type 520

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Low Differential Pressure Gage

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

AT9000 Advanced Transmitter Differential Pressure Transmitters

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Pressure Gauges with Electric Contact (Micro Switch Type)

Chip Inductors. LCCM Series Chip Common Mode Filter FEATURES CONSTRUCTION

PRODUCT SPECIFICATION

Acceleration/Velocity/Displacement VIBRATION METER

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

POINTS OF CAUTION BEFORE USE...

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

American Zettler AZ742 RELAY Datasheet

General Specifications

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

Integral V-Cone Flowmeter VD series

Cooling Water Flow Regulator

ISEmax CAM40/CAS40. Technical Information

AC axial compact fan

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

handbook, 050/052 4 columns smaller

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Impedance relay and protection assemblies

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Transcription:

eries Features Best pressure transmission solution for small and middle sized project such as indoor heating and air conditioning, water and sewer, or incinerator, etc. Improves noise resistance and minimize effects by external disturbance Realizes high accuracy measurement by stainless steel diaphragm of pressure sensing part for various measured subjects 4-20mA analog output (2-wire) Various functions : User input range, display scale, output scale, digital filter, multi-display selection, error display, TUF (two unit function), etc. Explosion class : Ex d ⅡC T6 IP67 Please read Caution for your safety in operation manual before using this unit. Ordering information G 6 N N F8 (0 to 5 kgf/cm 2 ) 1 2 3 4 5 6 7 Item Description 1Item Pressure Transmitter G Gauge pressure 2Measurement presssure A Absolute pressure Gauge pressure Absolute pressure 1 0 to 0.35kgf/cm 2 0 to 0.35kgf/cm 2 2 0 to 1kgf/cm 2 0 to 1kgf/cm 2 3 0 to 2kgf/cm 2 0 to 2kgf/cm 2 4 0 to 7kgf/cm 2 0 to 7kgf/cm 2 5 0 to 20kgf/cm 2 0 to 20kgf/cm 2 6 0 to 35kgf/cm 2 0 to 35kgf/cm 2 7 0 to 70kgf/cm 2-3Pressure range 8 0 to 200kgf/cm 2-9 0 to 350kgf/cm 2 - A -257mmHg to 0kgf/cm 2 - C -760mmHg to 0kgf/cm 2 - F -760mmHg to 2kgf/cm 2 - H -760mmHg to 7kgf/cm 2 - M -760mmHg to 20kgf/cm 2 - O -760mmHg to 35kgf/cm 2 - Z Others 4HART communication output N None N Without bracket 5Communication output B With bracket 6Pressure port F8 PF 3/8 7User pressure range User pressure range 1 : Write the desired pressure range and it is the default of user pressure range.(3 elect "Z" at pressure range) F-10

m 3 /h psi MPa mbar kg/cm 2 ton/h mmhg mmh 20 kpa % ma m 3 /h psi MPa mbar kg/cm 2 ton/h mmhg mmh 20 kpa % ma tandard Pressure Transmitter Dimensions Connections A. Recorder 83 128 (unit:mm) B. Indicator C. Converter D. Controller E. Thyristor unit Mounting bracket You can check 4-20mA output by connecting an ampere meter. (impedance: max. 30Ω) F. Pressure G. Temp. H. Accessories DN50 (2-Pipe) 200 96 96 83 1 2 3 4 5 6 2-1/2-14(NPT) Ampere meter 55 Mounting bracket 94 pecifications eries Measured materials Power supply method Character size Accuracy Temperature characteristics etting method ampling cycle Dielectric resistance Vibration Insulation resistance Noise resistance Memory protection Environment Material Explosion class 2 Approval Unit weight Vapor, Liquid, Fluid (except corrosive environment of U316) 15-35VDC 4 digit 12 egment LCD W 6.24 H10.73mm (12 egment) / W1.45 H2.5mm (unit) DC4-20mA 2-wire Low-limit : 3.6mA(-2.5%), High-limit : 21.6mA (+10%) ᆞᆞ10% of pan < URL: ±(0.05 + 0.015 URL/pan)% of pan ᆞᆞ10% of pan URL: ±0.2% of pan At 20, ±(0.075% URL + 0.15% pan) etting by front push keys 300ms 1000VAC for 1 min. (between external terminal and case) 0.75mm amplitude at frequency of 5 to 55Hz (for 1 min.) in each of X, Y, Z directions for 2 hours Min. 100MΩ (at 500VDC megger) quare shaped noise by noise simulator (pulse width 1 μs )±240V Approx. 10 years (non-volatile semiconductor memory type) Ambient temperature -20 to 70, storage: -20 to 80 Ambient humidity 0 to 85%RH Body : Aluminum(AlDc.8), Cover O-Ring : Buna N, Diaphragm : U316, Connections : U316 Ex d IIC T6 IP67 1.2kg 1. pan: User pressure range[ L-RG to H-RG] URL: Pressure range by model 2: This Explosion class is acquired and managed by Konics Co., Ltd. Environment resistance is rated at no freezing or condensation. TP20 KT-302H F-11

eries Part descriptions 2 1 part: s detected pressure value, several setting value and errors. 2 Unit display part: s the currently set input unit. 1 3 scale bar graph: s output 4-20mA as scale bar graph by 5% unit. 3 6 4 key: Used to enter parameter mode, move parameters and save V. 5 1, 4, 3 key: Used to enter parameter set mode, move digits. 6 D.IN3 : Press the 4 and 3 keys at the same time for 3 sec., the set function (display, zero-point adjustment) at DI-K in parameter. 4 5 Pressure conversion chart gf/cm 2 kgf/cm 2 Pa kpa MPa mbar bar mmh2o psi mmhg 1gf/cm 2 1 0.001000 98.0665 0.0980665 0.000098 0.980665 0.000981 10.00000 0.014223 0.735559 1kgf/cm 2 1000.000 1 98066.50 98.06650 0.098067 980.665 0.980665 10000.00 14.22334 735.5592 1Pa 0.010197 0.0000102 1 0.001000 0.000001 0.01 0.000010 0.101972 0.000145 0.007501 1kPa 10.19716 0.010197 1000.000 1 0.001000 10 0.010000 101.9716 0.145038 7.500617 1MPa 10197.16 10.19716 1000000 1000.000 1 10000 10.00000 101971.6 145.0378 7500.617 1mbar 1.019716 0.0010197 100.0000 0.100000 0.000100 1 0.001000 10.19716 0.014504 0.750062 1bar 1019.716 1.019716 100000.0 100.0000 0.100000 1000 1 10197.16 14.50377 750.0617 1mmH2O 0.100000 0.000100 9.80665 0.009807 0.0000098 0.0980665 0.000098 1 0.001422 0.073556 1psi 70.30699 0.070307 6894.757 6.894757 0.006895 68.94757 0.068948 703.0696 1 51.71493 1mmHg 1.359510 0.001360 133.3224 0.133322 0.0001333 1.333224 0.001333 13.59510 0.019337 1 Factory default Parameter Default Parameter Default Parameter Default Parameter Default UNIT BAR L-C 00)0 lout )000 DP1 PV L-RG )000 H-C 10)0 hout )350 DP2 PV H-RG )350 ZERO 000 MAvF 04 TUF dp )350 PAN!000 DI-K LOCK 1. Defaults are different by the pressure range by each model. Functions unit [ UNIT] You can select input unit. ( bar, mbar, Pa, kpa, MPa, gf/cm 2, kgf/cm 2, mmh 2 O, psi, mmhg, %, ) User input range [ L-RG, H-RG] scale [ L-C, H-C] This function is to set (-1999 to 9999) for particular high/ low limit value in order to display high/low limit value of measurement input. If measurement inputs are a and b and particular values are A and B, it will display a=a, b=b as below graphs. Even though each unit has the range, you can set user input range within the pressure range when input range is limited for actual usage. Decimal point setting [ dp] This function is to change decimal point digit for input display value. When input unit is set as % [?/O] or [ ], only the display position of decimal point is moved. et range : 0 / 0.0 / 0.00 / 0.000 et range is different by the pressure range. This function is available only when input unit is % [?/O] or [ ]. F-12

tandard Pressure Transmitter Zero-point correction [ ZERO] It corrects the error of display value for 0% input. et range : -999 to 999 lope correction [ PAN] It corrects the error of display value for 100% input. et range : 0.900 to 1.100 High/Low peak monitoring [ lpek, hpek] This function is to save high/low peak to check the invisible abnormal condition of system. elect this function display selection [ dp1, dp2] parameter. When the high/low peak is out of the temperature range, it displays HHHH or LLLL. To initialize high/low peak, press the 4, 3 keys at the same time for 3 sec. at [ hpek] or [ lpek]. In this case, peak value is the present input value. Two Unit Function [ TUF] For compound pressure model, this function displays the input pressure which is below atmospheric pressure by mmhg unit. It displays the input pressure atmospheric pressure or over atmospheric pressure by the set pressure unit. A. Recorder B. Indicator C. Converter D. Controller E. Thyristor unit F. Pressure G. Temp. H. Accessories scale [ lout, hout] For 4-20mA current output, this function is set to display value for current output. et the display value for 4mA [ lout] and the display value for 20mA [ hout]. Digital filter [ MAvF] Digital input [ DI-K] By front keys operation (D.IN3: 4 + 3 for 3 sec.), one of two functions executes as the below table. Z-TM Function Zeropoint adjustment lout hout lout hout Digital filter is able to display stably and output the noise from input line and irregular signals. This unit applies moving average digital filter and display cycle is same. et range : 01 to 16 when setting as 01, digital filter function does not run.) Operation Temporarily indicated value is stopped in order to confirm indicated value in unstable input. It is same function as [ZERO]. When executing this function, you can check and change correction value at ZERO. Multi-display selection [ DP1, DP2] elect one for display 1 and display 2 among PV, OUT, lpek, hpek. et DP1 and DP2 differently and it displays two different values in turn for 2 sec. When selecting lpek(hpek), the left (or the right) of output scale bar graph flashes for 0.5 sec. Lock [ LOCK] It limits to check parameter set value and to change it. Parameter initialization [ INIT] Error Parameter Descriptions Troubleshooting HHHH LLLL ERR LOc1 LOc2 : Enable to check/set, : Enable to check, disable to set, : Disable to check/set In LOc2, only the LOCK parameter displays. To initialize all parameter as factory default, supply the power to the product with pressing the key and 1 key at the same time and it enters initialization parameter. upply the power with pressing the + 1 keys at the same time. CLR NO 3 4 Flashes when measured pressure is higher than the 'pressure range'. Flashes when measured pressure is lower than the 'pressure range. Flashes when there is error to V YE Completes initialization. Adjust measured pressure within the 'pressure range'. Re-set it after checking the setting conditions TP20 KT-302H F-13

eries Parameters RUN mode unit UNIT 2 BAR 3 1. :Press any key among the 1, 3, 4. 2. 1: Moves digits / 4, 3: Changes V. 3. Press the M key after checking/changing V in each parameter. The value flashes twice and is saved. It moves to next parameter. 4. Defaults are different by the pressure range by each model. After entering setting group, press the M key for 3 sec. or there is no additional key operation in 30 sec., it returns to RUN mode. This parameter might not be displayed depending on other parameter settings. elect input unit. BAR mbar PA KPA MPA gcm?/o mmhg PI mmh2 KgCM Low-limit input value L-RG ---- et low-limit input value of input range. et range : within the pressure range of input type High-limit input value H-RG ---- et high-limit input value of input range. et range : within the pressure range of input type Decimal point position dp ---- elect the decimal point position of display scale value. et range is different by the pressure range. )0 )00 )000 0 Low-limit scale value L-C 00)0 et low-limit scale value. et range : -1999 to 9999 ed only when selecting input unit [ UNIT] as % [?/O] or [ ]. High-limit scale value H-C 10)0 Zero-point correction ZERO 000 et high-limit scale value. et range : -1999 to 9999 ed only when selecting input unit [ UNIT] as % [?/O] or [ ]. Corrects occurring error at 0% input. et range : -999 to 999 lope correction PAN!000 Corrects occurring error at 100% input. et range : 0.900 to 1.100 Low-limit output scale value lout ---- High-limit output scale value hout ---- Moving average digital filters MAvF 04 et low-limit output scale value. et range : Within temperature range when input unit is standard pressure unit. Within display scale range when input unit is % or. et high-limit output scale value. et range : Within temperature range when input unit is standard pressure unit. Within display scale range when input unit is % or. et the number of moving average digital filters. et range : 01 to 16 F-14

tandard Pressure Transmitter A. Recorder Digital input DI-K elect digital input function by front keys. Press the 4, 3 keys for 3 sec. at the same time and it executes the selected function. B. Indicator C. Converter Z-TM D. Controller 1 selection DP1 2 selection DP2 elect the value type for display 1. PV PV OUT lpek PV elect the value type for display 2. PV OUT lpek hpek hpek E. Thyristor unit F. Pressure G. Temp. H. Accessories Two Unit Function TUF et whether using two unit function. ed only for compound pressure model ON Lock LOCK elect lock function. LOc1 LOc2 Proper usage Caution for using For connecting the power, use a crimp terminal (M3.5, min. 7.2 mm). The connection of this unit should be separated from the power line and high voltage line in order to prevent inductive noise. Install a power switch or a circuit breaker to supply or cut off the power. witch or circuit breaker should be installed nearby users for convenient control. Do not use this unit near the high frequency instruments (high frequency welding machine & sewing machine, large capacity CR controller). When supplying input, if HHHH or LLLL is displayed, measured input may have problem. Turn off the power and check the line. Installation environment 1 Indoor / Outdoor 2 Altitude max. 2,000 m 3 Pollution Degree 2 4 Installation Category II Use the verified explosion-proof electric connection (cable gland or sealing fitting) (over Ex d IIC T6 IP67). Use the dedicated external terminal for earth. For connecting earth, use a spring washer and earth cable which is over 4mm 2. We are not responsible for any damages and claims for careless. Must read the cautions for your safety and using. This explosion-proof unit is certified and the same specifications which is reported to Korea Gas afety Corporation. If there are any problems with the unit, contact the sales office. It may cause malfunction if above instructions are not followed. TP20 KT-302H F-15