( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Similar documents
Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Technical Guide Thermo Scientific Syncronis HPLC Columns

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

HILIC Method Development in a Few Simple Steps

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Fluophase and Fluofix Columns

LC Technical Information

Hypersil BDS Columns TG 01-05

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

InertSustainSwift C8

Inertsil Technical Library

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Inertsil ODS-EP Technical Information

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Comparison Guide to C18 Reversed Phase HPLC Columns

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Your Reversed Phase Method

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

HPLC Column Classification

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Packings for HPLC. Packings for HPLC

InertSustainSwift C8

Part 2. Overview of HPLC Media

Reversed Phase Solvents

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

LC and LC/MS Column Selection Flow Chart

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Epic Aromatic Selectivity

8. Methods in Developing Mobile Phase Condition for C18 Column

Fast methods for the determination of ibuprofen in drug products

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Method Development Kits

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Analysis - HPLC A.136. Primesep 5 µm columns B.136

penta-hilic UHPLC COLUMNS

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Optimisil HPLC & UPLC Column catalogue

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

RP C18 column with feature of a silanol group

Choosing Columns and Conditions for the Best Peak Shape

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of trace anions in concentrated hydrofluoric acid

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

HPLC method development using alternative selectivities

ProPac WCX-10 Columns

Monitoring Protein PEGylation with Ion Exchange Chromatography

William E. Barber, Ph.D. Applications Chemist October

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

of mass spectrometry

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

UPLC Method Development and Validation

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Method Development with Modern HPLC Phases

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Overview Applications of NUCLEODUR HPLC Phases

Successfully Scaling and Transferring HPLC and UPLC Methods

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

ACE Ultra Inert Base Deactivated HPLC Columns

penta-hilic UHPLC COLUMNS

Transcription:

Selectivity Choices in Reversed-Phase Fast LC Luisa Pereira, Monica Dolci, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20543 Key Words Accucore, Hypersil GOLD, Syncronis, Column Chemistry, Fast LC, Radar Plots, Resolution, Solid Core, UHPLC Abstract The effect that different chemistries have on the selectivity of reversedphase (RP) packing materials is investigated. The retention properties of the stationary phases were categorized by analyzing primary modes of interaction (hydrophobicity, steric selectivity and hydrogen bonding) and secondary modes of interaction (ion exchange and chelation). Full characterization of the surface interactions of Thermo Scientific Accucore, Thermo Scientific Hypersil GOLD, and Thermo Scientific Syncronis stationary phases was achieved. Introduction The primary goal of developing a chromatographic separation is to resolve a mixture of analytes. From the graphical representation of the general resolution equation (Equation 1) in Figure 1 it is evident that the selectivity parameter has the greatest impact on resolution. Selectivity can be changed by modification of the mobile phase composition, column chemistry or temperature. Equation 1: R s = 1 a 1 k N 4 a 1 + k ( )( ) To fully characterize the surface chemistry of the reversed-phase materials, a series of diagnostic chromatographic tests were used (based on those developed by Tanaka). 1 These tests characterize analyte/stationary phase interactions and combine probes to measure hydrophobicity, shape selectivity, hydrogen bonding and secondary interactions with bases, acids and chelators. These tests are described as follows: Hydrophobic retention (HR) is the retention factor of a hydrophobic hydrocarbon, pentylbenzene, which gives a broad measure of hydrophobicity of the ligand and its density. Hydrophobic selectivity (HS) is the selectivity factor between pentylbenzene and butylbenzene and provides a measure of the surface coverage of the phase; these two alkylbenzenes differ by one methylene group and their selectivity is dependent on ligand density. Figure 1: Graphical representation of the general resolution equation

2 Steric selectivity (SS) is the ability of the stationary phase to distinguish between molecules with similar structures and hydrophobicity but different shapes. The selectivity factor between o-terphenyl and triphenylene is indicative of steric selectivity as the former has the ability to twist and bend, while the latter has a fairly rigid structure and can be retained quite differently. Hydrogen bonding capacity (HBC) is the selectivity factor between caffeine and phenol, which provides a measure of the number of available silanol groups and the degree of endcapping. Ion-exchange capacity at ph 2.7 (IEX2.7) is estimated by the selectivity factor between benzylamine and phenol, at ph 2.7. Tanaka showed that the retention of protonated amines at ph < 3 could be used to get a measure of the ion exchange sites on the silica surface. Silanol groups (Si-OH) are undissociated at ph < 3 and therefore cannot contribute to the retention of protonated amines, but the acidic silanols in the dissociated form (SiO-) can. The latter contribute to the retention of the protonated amines. Ion-exchange capacity at ph 7.6 (IEX7.6) is estimated by the selectivity factor between benzylamine and phenol and is a measure of the total silanol activity on the surface of the silica. At ph > 7 the silanol groups are dissociated and combine with the ion exchange sites to influence the retention of benzylamine. Base activity (BA) the presence of dissociated silanols at ph > 7 can cause poor peak shapes of protonated basic compounds, such as amitriptyline. Secondary ion exchange and silanolic interactions can cause shifts in retention and asymmetrical peaks. The capacity factor and tailing factor of amitriptyline are indicative of the overall performance of the column with regard to potential secondary interactions involving charged bases. Secondary metal interactions (C) silica surface metal interactions can cause changes in selectivity and peak shape for analytes which are able to chelate. Changes in the capacity factor and tailing factor of quinizarin, which is a chelator, are indicative of metal interactions. Acid interactions (AI) the capacity factor and tailing factor of chlorocinnamic acid are also measured to test the applicability of the stationary phases to a range of different types of acidic analytes. The phase characterization data obtained was summarized in radar plots, which allow visual comparison of the overall selectivity of the different stationary phase chemistries. Radar charts, also known as spider or star charts (because of their appearance), plot the values of each category along a separate axis that starts in the center of the chart and ends on the outer ring. Selectivity of Accucore Solid Core Range of Phases Accucore columns use Core Enhanced Technology to facilitate fast and high efficiency separations. Their 2.6 μm diameter particles have a solid core and a porous outer layer. The tightly controlled diameter provides much lower backpressure than typically seen with comparable size materials. The use of high purity silica combined with optimized phase bonding in Accucore columns creates a series of high coverage, robust phases. Accucore columns are available in a series of chemistries to provide a wide range of RP selectivities for method development: Optimized alkyl chain (RP-MS) C18 C8 Polar endcapped C18 (aq) Phenyl-Hexyl Pentafluorophenyl (PFP) The hydrophobic retention (HR) and selectivity (HS) of the C18, RP-MS and aq are comparable and significantly higher than those of the PFP and Phenyl-Hexyl phases. The steric selectivity (SS) of the aq phase is slightly higher than that of the C18 or RP-MS phase but considerable lower than that of the PFP phase, which shows the highest steric selectivity. The introduction of fluorine groups into the stationary phase causes significant changes in analyte-stationary phase interactions, which can produce high selectivity for positional isomers of halogenated compounds. The Phenyl-Hexyl phase offers a mixed mode separation mechanism, with the C6 chain responsible for hydrophobic interactions and the phenyl ring responsible for p p interactions. Accucore RP-MS uses an optimized alkyl chain length for more effective coverage of the silica surface. This coverage results in a significant reduction in secondary inter actions and thus highly efficient peaks with very low tailing, as evident from the low values for activity towards bases (BA) and chelators (C). The C8 phase has a similar radar plot shape to the C18 and RP-MS phases but with lower hydrophobic retention. These differences can be observed in the radar plots (Figure 2).

Figure 2: Summary of differences in selectivity offered by Accucore columns. HR= hydrophobic retention; HS= hydrophobic selectivity; SS= steric selectivity; HBC= hydrogen bonding capacity; IEX (7.6)= ion exchange capacity at ph 7.6; BA= activity towards bases; C= activity towards chelators; IEX (2.7)= ion exchange capacity at ph 2.7; AI= activity towards acids. 3

4 Selectivity of Hypersil GOLD 1.9 μm Range of Phases Based on highly pure silica, Hypersil GOLD columns provide very symmetrical peaks, even when analyzing compounds that give notoriously poor peak shape on traditional silica-based chemistries. Hypersil GOLD media provides a stationary phase with C18 selectivity and a predictable elution order, but can provide new capabilities such as improved peak shape, increased peak capacity, and greater sensitivity, especially for trace compound analysis. In addition to the C18 selectivity phase, Hypersil GOLD columns are available in a range of chemistries to provide a wide range of RP options for method development: C8 and C4 Polar endcapped C18 (aq) Phenyl Pentafluorophenyl (PFP) As demonstrated in Figure 3, all phases show low values for BA (activity towards bases), and C (activity towards chelators), as expected from the very high purity silica support and the proprietary bonding and end-capping procedures used in the manufacturing of these range of phases. The Hypersil PFP phase shows the highest steric selectivity of all phases in the range and also slightly higher than Accucore PFP. It is interesting to note that although the C4 phase is the least hydrophobic, it has hydrophobic selectivity comparable to the other phases investigated here (for instance Phenyl and PFP). Conclusion When working with fast LC it is important to have a wide choice of column chemistries to be explored during method development. The following guidelines can be used to make the correct column selection: The Syncronis range of columns having a high surface area provides very retentive phases for polar and moderately polar analytes The phases in the Hypersil GOLD range exhibit the lowest secondary interactions, providing the most symmetrical peaks for difficult analytes such as bases and chelators The Accucore solid core columns have a good range of chemistries with a wide spread of selectivity Syncronis aq and Syncronis C18 exhibit the highest hydrophobic retention The perfluorinated phases (Hypersil GOLD PFP and Accucore PFP) exhibit the highest steric selectivity From the phases with aromatic groups, the Phenyls and Pheny-Hexyl exhibit inverse steric selectivity to the PFPs References 1. N. Tanaka et al., Journal of Chromatographic Science, 27 (1989) 721-728 Appendix Selectivity of Syncronis 1.7 μm Range of Phases Syncronis columns are based on a highly pure 100 Å silica, with a surface area of 320 m 2 /g, compared to 175 Å and 220 m 2 /g for the Hypersil GOLD material. This greater surface area ensures greater retention of analytes by a hydrophobic mechanism. The high surface area also allows for higher sample loading. The Syncronis RP stationary phases investigated in the current study are: C18 C8 Polar endcapped C18 (aq) Phenyl Syncronis C18 and Syncronis aq provide very high hydrophobic retention (HR), as shown in the radar plots in Figure 4. Ion exchange capacity (7.6) is higher on Syncronis aq than on the other phases. The highest steric selectivity is observed for Syncronis aq. The chart in Figure 5 provides an overview of the relative hydrophobic retention and steric selectivity of all the phases compared in this document. Syncronis C18 has the highest hydrophobic retention, Hypersil GOLD PFP has the highest steric selectivity. For phases that show a value of steric selectivity below 1 there is a reversal of the elution order of o-terpheyl and triphenylene, the probes used to measure that parameter.

Figure 3: Summary of differences in selectivity offered by Hypersil GOLD columns. HR= hydrophobic retention; HS= hydrophobic selectivity; SS= steric selectivity; HBC= hydrogen bonding capacity; IEX (7.6)= ion exchange capacity at ph 7.6; BA= activity towards bases; C= activity towards chelators; IEX (2.7)= ion exchange capacity at ph 2.7; AI= activity towards acids. 5

6 Figure 4: Summary of differences in selectivity offered by Syncronis columns. HR= hydrophobic retention; HS= hydrophobic selectivity; SS= steric selectivity; HBC= hydrogen bonding capacity; IEX (7.6)= ion exchange capacity at ph 7.6; BA= activity towards bases; C= activity towards chelators; IEX (2.7)= ion exchange capacity at ph 2.7; AI= activity towards acids. 3.00 2.50 Hypersil GOLD PFP Accucore PFP Steric selectivity 2.00 1.50 1.00 0.50 Hypersil GOLD aq Accucore aq Accucore C18 Hypersil GOLD Phenyl Hypersil GOLD Accucore RPMS Hypersil GOLD C8 Syncronis Phenyl Hypersil GOLD C4 Syncronis C8 Accucore Phenyl-Hexyl Accucore C8 Syncronis aq Syncronis C18 0.00 0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 Hydrophobic retention Figure 5: Comparison of the steric selectivity and hydrophobic retention of Accucore, Hypersil GOLD and Syncronis ranges.

Variable Probe Structure Test # Hydrophobic retention (HR) k pentylbenzene 1 Hydrophobic selectivity (HS) α (Pentylbenzene/butylbenzene) 1 Technical Note 20543 Secondary Interactions Primary Interactions Steric selectivity (SS) α (Triphenylene/o-terphenyl) 1 H-bonding capacity (HBC) α (caffeine/phenol) 1 IEX capacity ph 7.6 (IEX 7.6) α (benzylamine/phenol) 2 IEX capacity ph 2.7 (IEX 2.7) α (benzylamine/phenol) 3 Activity towards bases (BA) Tailing factor of amitriptyline 2 Activity towards chelators (C) Tailing factor of quinizarin 2 Activity towards acids (AI) Tailing factor of chlorocinnamic acid 3 Table 1: Summary of test probes and structures. Test 1 Test 2 Test 3 Mobile Phase H 2 O/CH 3 OH (35:65) K 2 HPO 4 10 mm ph 7.6/CH 3 OH (20:80) KH 2 PO 4 10 mm ph 2.7/CH 3 OH (55:45) Flow Rate (ml/min) 0.5 0.6 0.5 0.6 0.5 0.6 Temperature ( C) 40 40 40 Detection (nm) 254 254 254 Injection Volume (µl) 10 5 5 Table 2: Experimental conditions of diagnostic tests. For more information, visit our website at www.thermoscientific.com/crc 2013 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. USA and Canada +1 800 332 3331 Australia 1300 735 292 (free call domestic) China +86 21 68654588 +86 10 84193588 +86 20 83145199 800 810 5118 France +33 (0)1 60 92 48 34 Germany +49 (0) 2423 9431 20 or 21 India +91 22 6742 9494 +91 27 1766 2352 Japan +81 3 5826 1615 United Kingdom +44 (0) 1928 534 110 New Zealand 0800 933 966 (free call domestic) All Other Enquiries +44 (0) 1928 534 050 Technical Support North America +1 800 332 3331 Outside North America +44 (0) 1928 534 440 TN20543_E 01/13M