Water terminal control solutions

Similar documents
XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS

ClimateMaster s Tranquility 22. Raj Hiremath Director of Residential Marketing

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

SVH with HYDROVAR (HVL range)

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

Installation Operation Commissioning Maintenance

TEC BACnet MS/TP Network Series Thermostat Controllers Technical Bulletin

Offi ces account for more than 30% of total commercial building energy use

6-way valve with room temperature controller. Balanced climate control. World premiere! e. Cost and energy economies

Variable swirl diffusers

Swegon CASA Smart ModBus Register SCB 3.0

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

Reference 1 Thermal Energy Metering. Abstract: Some aspects of the selection and installation requirements for thermal energy metering are canvassed.

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

PATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency

VK2 volume flow controller Overview

Lightcloud Application

VRF Technical Data Book

Rectangular air volume controller RWPA

Intuitive air velocity and IAQ.

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Aircon Energy Saver Evaluation Report for SHUI ON DEVELOPMENTS ...

variable flow dampers

TALLINN UNIVERSITY OF TECHNOLOGY, INSTITUTE OF PHYSICS 6. THE TEMPERATURE DEPENDANCE OF RESISTANCE

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

QNET Experiment #05: HVAC System Identification. Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

UA-SS FAQS UA-SS FAQS

Advanced Adaptive Control for Unintended System Behavior

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Interactivity-Compatibility. TA Hydronic College Training

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

Modular contactors for installation into distribution

A Rain Sensitive House Window Closes Automatically When Raining

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Non- Iterative Technique for Balancing an. Air Distribution System

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

473-SHX Dew Point Mirror

Dynamic simulation of DH house stations

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

AIR COOLED CONDENSING UNIT

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

AIR COOLED CONDENSING UNIT

E THERMADATA LOGGER Humidity & temperature recording meter

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Circular air volume controller RWOA

Minute Impulse Clock Controller I01DN

RC Circuit (Power amplifier, Voltage Sensor)

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

473 Dew Point Hygrometer

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

6 Securing of the delivery and acceptance

ISM Evolution. Elscolab. Nederland BV

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

PAA-ANALYZERS PRINCIPLE OF OPERATION

TRAM LINE SWITCH POINT HEATING

Better Weather Data Equals Better Results: The Proof is in EE and DR!

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

Electrolysis System CHLORINSITU V (PLUS)

VT8600 Series BACnet Integration

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

2 Verification of the design prerequisites (Design intent)

Elios X3 DIGITAL CONTROL SYSTEM FOR THE MANAGEMENT OF SOLAR HEAT PLANT

Innovative Sustainable Technology

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

WeatherWatcher ACP. Astronomers Control Panel (V4 or >) Ambient Virtual Weather Station (Pro or Internet editions) ASCOM platform v4.

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

Precision Circuits Inc

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

AIR CONDITIONERS 2016 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units. Online Interactive Edition v.1.

EXISTING PANEL "22C" CIR.# TYPE DESCRIPTION VOLTAGE 208Y/120V WIRE SIZE EXISTING PANELBOARD SCHEDULE PHASE WIRE NEUTRAL AIC MAIN % (E) 400A MLO

Air distribution systems. Linear whirl outlet WL...

Digital Controller Operation

Swirl Diffusers Type DLA 7 and DLA 8

Installation Instructions

Air distribution systems. Adjustable induction outlet IN-V...

RainMachine Mini- 8 Quick- Start Guide

Construction Of A Temperature Controlled Fan Using A Microprocessor.

Designing a Thermostat Worksheet

MASTER TL5 Lamps. The Safety and. fit. TrustSight LED Emergency drivers. A full range of MASTER TL5 Lamps

A PRELIMINARY MODEL OF USER BEHAVIOUR REGARDING THE MANUAL CONTROL OF WINDOWS IN OFFICE BUILDINGS

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

5SJ4...-.HG Circuit Breakers to IEC and UL 489

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Transcription:

Water Terminal Control Solutions Water terminal control solutions Carrier offers a wide range of fan coil units designed to meet the needs of different systems and applications: from cabinet units in the room, through cassettes and a variety of ducted units that allow remote installation. The benefits and advantages of the different offers are described in the Hydronic Fan Coil Solutions brochure. To complement the different fan coil solutions, Carrier offers a range of electronic controllers, developed and tested to ensure correct management of hydronic terminal fan coil units and to deliver maximum satisfaction to the user. These controllers are available for all system configurations including: 2-pipe, 2-pipe changeover, 2-pipe + electric heater and 4- pipe applications. A selection of fan coil controllers is available, designed to offer the best solution for each installation, with the performance features required by the customer. Features Stand-alone electronic thermostats offer a costeffective solution that does not compromise on features and includes enhancements such as an energy-saving option (eco mode). Grouped and remote control needs are met with the HDB controller. This is factory-installed in the units, making installation easy. Only the power supply and the user interface connections for the wall-mounted or infrared remote control need to be field-connected. Where grouping of the fan coil units is required by the application, the simple addition of an optional communication board and the corresponding daisychain bus wiring will provide this functionality. The communicating control system offer includes the new NTC communicating controller. This advanced controller can integrated into the Carrier Aquasmart Evolution hydronic system range or into any Carrier system using the Carrier Comfort Network (CCN) protocol. Depending on the application needs, this controller offers a broad range of user interfaces, and advanced functionalities such as variable-speed fan control or Demand Control Ventilation. Whatever the customer requirements, Carrier offers a solution.

M s T h e r m o s t a t s H D B N T C A q u a s m a r t C o n t r o l a l g o r it h m O n o f f x x P r o p o r t i o n a l i n t e g r a l x x V a lv e m a n a g e m e n t A i r f l o w c o n t r o l o n ly ( n o v a lv e ) x x x O n o f f a c t u a t o r s x x x P r o p o r t i o n a l v a lv e s o F a n c o n t r o l T h r e e s p e e d s x x x x O p t i m u m f a n s p e e d s e l e c t i o n x x x x V a r i a b l e s p e e d o a i n f u n c t i o n s S e t p o i n t c o n t r o l x x x x O c c u p i e d / u n o c c u p i e d m o d e x x x x F r o s t p r o t e c t i o n m o d e x x x x W i n d o w c o n t a c t i n p u t x x x x M e a s u r e m e n t o f w a t e r i n l e t t e m p e r a t u r e f o r a u t o m a t i c s e a s o n a l c h a n g e o v e r ( 2 p i p e s ) T y p e A x x x A u t o m a t i c s e a s o n a l c h a n g e o v e r ( 4 p i p e s a n d 2 p i p e s + e l e c t r i c h e a t e r ) T y p e B x x x M a n u a l c h a n g e o v e r x x x x F r o s t p r o t e c t i o n m o d e x x x x C o n t i n u o u s v e n t i l a t i o n w h i n d e a d b a n d x x x x P e r i o d i c a l v e n t i l a t i o n w h i n d e a d b a n d x x x x U n g r o u p i n g x x x L o u v r e c o n t r o l x x x O n s e c o n f i g u r a t i o n x x x S u p p a i r t e m p e r a t u r e m o n o r i n g l i m i n g x x C o m m u n i c a t i o n ( C C N ) x x E l e c t r i c a l h e a t e r l o a d s h e d x x D i r t y f i e r a l a r m x x A l a r m r e p o r t i n g x x I A Q c o n t r o l o D e m a n d c o n t r o l v e n t i l a t i o n ( D C V ) o F r e e c o o l i n g m o d e o it it it it ly it it lt U s e r i n t e r f a c e D i g it a l d i s p l a y x x x A u t o m a t i c o r m a n u a l f a n s p e e d c o n t r o l x x x x O p e r a t i n g m o d e s e l e c t i o n x x x x O c c u p a n c y ( e c o ) b u t t o n x x x x S y s t e m m a n a g e m e n t M a n a g e m e n t o f z o n e s x S e t p o i n t m a n a g e m e n t a c c o r d i n g t o o c c u p a n c y x M a n a g e m e n t o f s y s t e m h e a t i n g / c o o l i n g m o d e a c c o r d i n g t o b u i l d i n g d e m a n d x S c h e d u l i n g o f s y s t e m o p e r a t i o n p e r z o n e x C e n t r a l i s e d m a n a g e m e n t o f o p e r a t i n g p a r a m e t e r s, a l a r m s a n d m a i n t e n a n c e x o = a v a i l a b l e a s a n o p t i o n

F e a t u r e s Fan operation With the fan speed selector, fan mode can be set either manually or automatically. In the manual mode it is possible to select three fan speeds (low/medium/high) according to personal preference. In the auto mode fan speed is regulated by a microprocessor in the control, based to the temperature chosen. Temperature selector This is designed to maintain the temperature at the desired level. The reference value at the centre of the range is 20 C. By turning the knob towards the symbol (-) the temperature is reduced from the original setting (minimum value is 10 C). By turning the knob towards the symbol (+), the temperature is raised from the original setting (maximum value is 30 C). Energy saving mode This function is especially useful when air conditioning at night or in rooms where the user is likely to be absent for a longer period of time. In this case, pushing the button raises the temperature during cooling by 4 C and lowers it during heating by 4 C. Frost-protection This function keeps the temperature from dropping below 7 C in rooms not used for long periods of time. Seasonal changeover - Manual: Selection of heating/cooling is done manually by pushing the button on the control. - Centralised (only for type A control): Centralised seasonal changeover is possible in two ways: - by a switch located on the central control panel that allows heating/cooling mode changeover (to be provided by the installer). - by a temperature sensor located in contact with the entering water pipe - Automatic, based on air temperature (only for type B control): The automatic seasonal changeover allows automatic switching of the fan coil operating mode to cooling or heating, depending on the temperature set by the user and on the room temperature. External contact The control has a 230 V input that can be used as window contact or presence detector. When such a signal is activated (presence of line voltage on the terminal block contact) the control is set to OFF mode. As a consequence, all outputs (fan, valves etc.) are disconnected, and only frost protection is active, if switched ON by the appropriate dip-switch. The Carrier electronic thermostats are designed to control and optimise the operation of hydronic terminal fan coil units. They exist in two versions (types A and B) that match all terminal fan coil configurations. T y p e A T y p e B 2 J p i p e x 2 J p i p e c h a n g e o v e r x 2 J p i p e a n d e l e c t r i c h e a t e r x 2 J p i p e c h a n g e o v e r a n d e l e c t r i c h e a t e r x 4 J p i p e x

F e a t u r e s The HBD controller is a microprocessor-based controller designed to control and optimise the operation of hydronic terminal fan coil units. Factory-installed on the terminal fan coil The controller is factory-installed on the terminal fan coil; the assembly is also tested at the factory. As a result, field installation is extremely simple. User interfaces Depending on the application, two user interface types can be selected: - a wired user interface that can be mounted on the wall or inside compatible terminal fan coils (42N) - an infrared user interface to be used together with a wall-mounted infrared received or a receiver incorporated in compatible terminal fan coils (42GW) Ease of grouping As an option, the HDB control can be equipped with a grouping board that is used to connect up to 15 units with a bus. All units connected together will operate under the same conditions. Louvre control For terminal fan coils equipped with motorised louvres, the HDB controls the louvre position as defined by the user or in swing mode. External contact The control has an input that can be used to remotely set the unit to economy mode. Scheduling If the unit is used with an infrared user interface, unit operation time can be scheduled on a daily basis. Three start times and three stop times can be programmed. Timer If the unit is used with an infrared user interface it can operate for a predefined duration before switching to eco mode or off. 56 250 190

A B A B F e a t u r e s The NTC controller is a microprocessor-based, CCN (Carrier Comfort Network) compatible communicating controller designed to control and optimise the operation of hydronic terminal fan coil units. The controller can function as either a standalone control or as part of the CCN. Factory-installed on terminal fan coils The HDB controller is factory-installed on the terminal fan coil; the assembly is also factory-tested. As a result, field installation is extremely simple. User interfaces Depending on the application, two user interface types can be selected: - a simplified wired user interface (SUI) that can be wall-mounted - a wired user interface (CRC2) that can be wallmounted or incorporated in compatible terminal fan coils (42N) - an infrared user interface (IR2) for use together with a wall-mounted infrared received or a receiver incorporated on compatible terminal fan coils (42GW) - a multifunction user interface (ZUI) that can control comfort, lights and blinds within a Carrier system Network communication The NTC communicating controller can be connected on an RS 485 bus, using the Carrier Comfort Network (CCN) protocol. Units equipped with the NTC communicating controller can be part of the Aquasmart Evolution system. In addition, the NTC communicating controller can offer the following functions as options (not available within Aquasmart Evolution environment): - Variable speed management: The NTC controller can drive the speed of the fan continuously within a configurable range for optimal thermal and acoustic comfort. - Demand controller ventilation (DCV): On fan coils equipped with CO 2 sensors and fresh air dampers, the NTC controller can adjust the amount of fresh air admitted to the room, as required by the occupants - IAQ management: The NTC controller can control all features related to Indoor Air Quality that are included in Carrier terminal fan coil units. 56 250 190 1 4 b 2 1 1 1 1 3 3 3 4 a 5 6 L e g e n d 1 N T C c o n t r o l l e r 2 S e c o n d a r y c o m m u n i c a t i o n b u s 3 U s e r i n t e r f a c e c o n n e c t i o n 4 I R 2 5 Z U I 2 6 C R C 2 L o c a l A L o c a l B

p A B F e a t u r e s Aquasmart Evolution is a complete HVAC system especially suited for residential and light commercial office buildings, hotels and hospitals. Aquasmart ensures perfect comfort for the building occupants. It allows both individual control, based on comfort parameters and central control to ensure optimisation of energy consumption. The Aquasmart System Manager is connected to the system components via a communication bus, and controls all air conditioning operating parameters. By coordinating the control intelligence in each component and by assembling all data at a single point, Aquasmart Evolution optimises energy consumption, monitors component operation and continually reports any system faults. The system can be composed of up to 128 terminal fan coil units that can be organised in 32 zones. Heating and cooling is coordinated by the System Manager for maximum comfort and optimal energy consumption. Occupied/unoccupied time schedules can be programmed, and the system includes smart start features to ensure that comfort requirements will be met from the very beginning of the occupied period. System configuration is simple through easily accessible menus. Unit grouping is managed by the network and requires no specific wiring. This means the system can be easily reconfigured to suit later modifications to the occupied area. The Aquasmart Evolution components are delivered complete, configured and factory-tested. H e a t p u m P r i m a r y b u s S y s t e m M a n a g e r S e c o n d a r y b u s 1 2 1 1 1 L e g e n d 1 N T C c o n t r o l l e r 2 S e c o n d a r y c o m m u n i c a t i o n b u s 3 U s e r i n t e r f a c e c o n n e c t i o n 4 I R 2 5 Z U I 2 6 S U I 7 C R C 2 L o c a l A L o c a l B 3 3 3 3 4a 5 6 7 4b

M a n u f a c t u r e d b y : C a r r i e r S C S, M o n t l u e l, F r a n c e. O r d e r N o. 1 4 7 1 0 ê 2 0, 0 5. 2 0 0 7. S u p e r s e d e s o r d e r N o. : N e w. P r i n t e d o n T o t a l ly C h l o r i n e F r e e P a p e r. M a n u f a c t u r e r r e s e r v e s t h e r i g h t t o c h a n g e a n y p r o d u c t s p e c if i c a t i o n s w it h o u t n o t i c e. P r i n t e d i n t h e N e t h e r l a n d s.