Attachments. T Type Interface: (T) M5 X 0.8, 1/ 8, 1/ 4, 3/ 8, 1/ 2 Makes it easy to diverge air out with T type interface

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

Universal type Port size AS13 1F-M3. M3 x 0.5 M5 x 0.8 AS23 1F-01 AS23 1F-02 AS33 1F-02 AS33 1F-03 AS43 1F-04 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2

Odor Removal Filter Series AMF

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Flow rates to 750 l/min

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Flow rates to 485 l/min

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Flow rates to 750 l/min

E8EB-N0C2B E8EB-N0B2B

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Identification Number

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

180 Angular Gripper. Series MHY2/MHW2. Cam actuation style is now standardised! 5-241

Flow rates to 475 l/min

PHOENIX CONTACT - 04/2016. Features

Direct-operated 2/2-way solenoid valves Type EV210B

Flow rates to 485 l/min

Flow rates to 485 l/min

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

CKA Series. 3-way jaw thin chuck double acting/single acting. Operational stroke length: 5, 6, 7, 9, 20, 25, 30, 38mm.

Operating Instructions for Digital Manometer. Model: MAN-SD

Commercial Generator Parts Catalog. PROTEC Series

Rotary modules.

Safety valve with unit approval type MV..X.., SV..X..

Model Selection 1. Process Valves. Air. Vacuum

PUSH TUBE STANDARD DUTY

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

Body (Black) O-ring Stud. Effective when piping in a confined space. The body and the threaded portion can rotate (For positioning to some extent).

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

Cooler-Bypass Thermostat Valve, Size 10

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Precision Ball Screw/Spline

Model Selection 1. Process Valves

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

P303 Pressure Regulator

ATV WP2 FRONT MOUNT PUSH TUBE

Free Mount Cylinder Double Acting, Double Rod. ø6, ø10, ø16, ø20, ø25, ø32. How to Order. Action. D Double acting. Standard stroke (mm)

Flow rates to 590 l/min

2/3 Port Valves for Fluid Control Model Selection 1

SHARK Snow Plow. 52 (132 cm) / 60 (152 cm) Complete system blade INSTRUCTIONS / ESTABLISHMENT

Vane Type Rotary Actuators Series Variations

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

Direct-operated 2/2-way compact solenoid valves Type EV210A

EX-EMERGENCY LIGHT FITTINGS

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Installation, Maintenance and Operating Instructions

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

VOLUMEC. Valve Position Indicator 5

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

2/3 Port Valves for Fluid Control Model Selection 1

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.)

Operating instructions Vortex flow meter. SVxxx / / 2015

Ballistic pendulum Operating Instructions Fig. 1: Ballistic pendulum SAFETY PRECAUTIONS

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

Spare parts list UC-S

Peltier Application Note

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

Odor Removal Filter. Model Note) 1 8, , , , 3 4. Model/Free Standing Type AMF800. Model/Piping Support Type AMF Port size

Installation guide 862 MIT / MIR

Manually Operated Directional Valves DMT- 03 / 06 / 10 DMG-01 / 03 / 04 / 06 / 10 Thread Connection / Sub-plate Mounting.

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

HARTING D-Sub Selection Guide

Observing Procedure for C11 GPS

Solenoid valves Type EVUL

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

POWER PUSHER Snowplow

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

nufacturing Company, L.P San Felipe, Suite

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Universal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure

High Pressure fi lters

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

Transcription:

Modular Style Air Combination Series AC Assembled by simply tightening the screws High strength die cast bracket Drain cock for one push drain exhaust Oil needle for easy oil volume adjustments The improved needle and the easily grasped handle make for easier oil volume adjustments Pressure gauge A pressure gauge equipped with a limit indicator on which the prescribed pressure range can be viewed at a glance. (Applicable to 20 0 to 60 0) One-hand lock with colour indicator The handle can be operated more reliably because the locked state of the pressure regulation handle can be checked at a glance by whether the orange mark is visible. If the orange mark is visible, the pressure can be regulated. (0 0, 0, 0 only) Bowl can be attached and detached with one hand. (Turn proof structure at pressurized state).-

Air Combination Series AC Standard Combinations Constructing equipment ++ Combination Port size AC000 AC2000 M5 /8, / Air filter 000 2000 Regulator 000 2000 Lubricator 000 2000 Filter regulator Mist separator M AC AV AC20 /, /8 000 20 000 AU AC000 AC00 AC00-06 AC00 AC50 /, /8 /, /8, /2 / /, 000 00 00-06 00 6000 000 000 00 00 00-06 00-06 00 00 00 6000 IR VEX AC6000 6000 6000 6000 SRP + AC00 M5 000 000 + AC200 AC00 AC0 AC0-06 AC020 AC2020 /8, / /, /8 /, /8, /2 / M5 /8, / 000 2000 000 2000 2000 000 00 00-06 2000 000 00 00-06 AMR M D ITV VBA AC2520 AC020 AC20 /, /8 /, /8 /, /8, /2 000 000 00 20 000 00 AC20-06 / 00-06 00-06 AC20 /, 00 00 AC5520 6000 00 AC6020 6000 6000 +M+ AC200 /8, / 2000 2000 M2000 AC250 /, /8 000 20 M000 AC00 /, /8 000 000 M000 AC0 /, /8, /2 00 00 M00 AC0-06 / 00-06 00-06 M00-06 +M AC20 /8, / 2000 M2000 AC0 /, /8 000 M000 AC /, /8, /2 00 M00 AC-06 / 00-06 M00-06.-2

Series AC How to Order Air combination Body size 0 M5 20 /8 25 / 0 /8 /2 / 55 60 Combination of equipment Combination of equipment Symbol Filter Regulator Lubricator Filter Mist () () () regulator separator () (M) 00 q w e 0 w q 20 q w 0 q e w q w () Numbers in K indicate the constructing order from the left hand side (upper stream) with a view from front. Ex.) Symbol 00 ++ 0 + (Available only for AC00 to 0.) 20 + 0 +M+ (Available only for AC200 to 0.) +M (Available only for AC20 to.) (2) Standard bracket for a set of 2 pieces: T type bracket A set of pieces or more: L type bracket N F Accessories (Options) Symbol C D E AC 0 00 F 0 D ST 2R Ordering source area code Japan, Asia - Australia E Europe N North America Description Auto drain Auto drain Pressure gauge Thread Metric thread (M5) Rc (PT) NPT (PF) M5 0 02 0 0 06 0 Port size M5 X 0.8 /8 / /8 /2 / Applicable model Float style (N.C.): AC20 to AC6000 Pressure differential style: AC000, AC2000 Float style (N.O.): AC20 to AC6000 Without limit indicator: AC000 With limit indicator: AC2000 to AC6000 T V If indicating more than one symbol, place the desired symbols in numerical order then alphabetical order. Example) 2NR Note ) Only adjusting spring of regulator is different from standard specification. Note 2) Without valve mechanism. Attachments Symbol Description Mounting location Applicable of attachment model None + + K + AC2000 to AC00 K Check valve + K + AC200 to AC0 + + S + AC2000 to AC6000 S Pressure switch + S + AC2020 to AC6020 + M + S + AC200 to AC0 T type interface Residual pressure exhaust port valve Option specifications () Set at 0.02 to 0.2MPa (Regulator) 2 6 8 C J (2) N R W Metal bowl (Filter/Lubricator) Lubricator with drain cock Nylon bowl (Filter/Lubricator) Metal bowl with level gauge (Filter/Lubricator) (Applicable to AC20 to AC6000.) Bowl guard (Applicable to AC20 0 only.) Drain guide port size / (AC20 to AC6000) Non relieving style (Regulator) Flow direction: Right to left Drain cock with barb fitting: For ø6/ø nylon (Filter) (Applicable to AC20 to AC6000) + T + + AC000 to AC6000 + T + AC020 to AC6020 + M + T + AC200 to AC0 + + + V + + V + + V + M + + V + M + V AC2000 to AC00 AC200 to AC0 AC2020 to AC20 AC200 to AC0 AC20 to AC Air intermediate output port size AC20 0: / 8 AC25 0: / AC0 0: / AC 0: / 8 AC0 0: M5 X 0.8 AC20 0: / 8 AC25 0: / AC0 0: / AC 0: / 8 AC 0: / 8 AC55 0: / 2 AC60 0: / 2 Note ) If indicating more than one symbol, place the desired symbols in alphabetical order. Note 2) For piping adapter, pressure switch with piping adapter and cross interface, indicate part number, separately. Note ) Consult SMC if using pressure switch and T type interface simultaneously..-

Air Combination Series AC Option Specifications Combination List Accessory Option specification Description Accessory F.R.L. Combination applicable model Option specification (Auto drain) AC000 AC2000 AC2020 AC2520 AC000 AC00 AC020 AC00 AC0 AC020 AC200 AC20 to to D D C 2 6 8 C J N R W AC00 AC200 AC20 AC250 AC6000 AC0 AC6020 AC0 AC Auto drain press. differential D Auto drain float style (N.O.) D Auto drain float style (N.C.) C Set at 0.02 to 0.2 MPa - Metal bowl -2 Lubricator with drain cock - Nylon bowl -6 Metal bowl with level gauge -8 With bowl guard -C Drain guide (Port size / ) -J Non relieving style -N Flow direction: right to left -R One-touch drain cock w/ barb fitting -W Attachments Piping adapter Symbol : Combination possible : Combination impossible : Depends on the model Port size M5 / 8, /, / 8, / 2, /, Mechanism Able to connect and disconnect equipment without detaching piping. AC AV AU IR VEX SRP AMR M D ITV VBA Pressure switch with piping adapter / 8, /, / 8, / 2, / Compact switch united with piping adapter Check valve Pressure switch T type interface / 8, /, / 8 M5 / 8, /, / 8, /2 Prevents reverse flow from lubricator. Compact switch Able to diverge air. Residual pressure exhaust port valve / 8, /, / 8, /2 Able to exhaust residual pressure in the line. Cross interface M5 / 8, /, / 8, /2 Able to diverge piping in all directions..-

Air Combination Air Filter + Regulator + Lubricator AC000 to 6000 JIS symbol AC2000 AC000 AC00 Standard Specifications Air filter Regulator Lubricator AC000 AC2000 AC20 AC000 AC00 AC00-06 AC00 AC50 AC6000 Air filter 000 2000 000 000 00 00-06 00 6000 6000 Combination equipment Regulator 000 2000 20 000 00 00-06 00 00 6000 Lubricator 000 2000 000 000 00 00-06 00 6000 6000 Port size M5 /8 / / / / /8 / / /8 /8 /2 auge port size /6 /8 /8 /8 / / / / / Fluid Air Proof pressure.5 MPa Max. operating pressure.0 MP Set pressure range 0.05 to 0. MPa 0.05 to 0.85 MPa Flow (l/min(anr))(port size) () 0 (M5 X 0.8) 0( / ) 0( / 8 ) 2000( / 8 ) 00( / 2 ) ( / ) 00( / ) 6000() 6000() Ambient and fluid temperature Filtration 5 to 60 C (Non-freezing) 5µm Recommended lubricant Bowl material Construction/Regulator Turbin oil class (ISO V2) Polycarbonate Relieving style Weight (kg) 0.26 0..0.8 2. 2..82.0. Accessory Bowl guard (Standard equipment) Bracket B0L B20L B0L B0L B0L B50L B60L B60L B60L Note ) Supply pressure: 0. MPa, Set pressure: 0.5 MPa Attachments/Accessories (Options) Attachment Accessory Part No. Description For AC000 For AC2000 For AC20 For AC000 For AC00 For AC00-06 For AC00 For AC50 For AC6000 0 Piping adapter E0-M5 E20- E0- E0-06 06 06 E- 0 E- 06 E60- E60- E60-0 0 0 0 0 06 0 2 Pressure switch with piping adapter IS000E- Y 2 IS000E- Y IS000E- Y IS000E- 0 Y 2 0 0 06 Check valve (2) 0 AKM2000- (02) AKM000- (0) AKM000- (0) AKM00- (02) Pressure switch IS000M-2Y IS000M-Y IS000M-Y IS000M-Y IS000M-5Y IS000M-6Y IS000M-6Y IS000M-6Y T type interface (2) 0 (0) (0) (02) (02) (0) (0) Y-M5 Y2- (02) Y- Y- Y- Y5- Y6- (0) Y6-0 Y6-0 Residual press. exhaust port valve 0 VHS2000- VHS000- VHS000- VHS00-0 0 0 0 Cross interface Y-M5 Y2- Y- Y- Y- Y5-0 T type bracket B0T B20T B0T B0T B0T B50T B60T B60T B60T Interface Y0 Y20 Y0 Y0 Y Y Y60 Y60 Y60 Pressure.0MPa 2-0-R 6-0- 0 6-0- 0 6-0- 0 6-0- 6-0- 6-0- 6-0- 6-0- gauge 0.2MPa (2-0-R) () 6-2- 0 6-2- 0 6-2- 0 6-2- 6-2- 6-2- 6-2- 6-2- Auto drain N.O. AD AD AD AD AD AD AD float () N.C. AD5 AD5 AD5 AD5 AD5 AD5 AD5 Auto drain w/ press. diff. AD6 AD62 Note 2) Standard specification of air combination: Port size without ( ) Note ) Use the one for.0mpa Note ) Minimum operating pressure: N.O. 0. MPa, N.C. 0.5MPa -0, -02, -0, -0, -06, -0 after part number indicate port size. (0: / 8, 02: /, 0: / 8, 0: / 2, 06: /, 0: ) Note 5) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauges..-5

AC000 to 6000 Flow Characteristics Condition: Supply pressure 0.MPa AC000 M5 AC00-06 Rc(PT)/ AC2000 Rc(PT)/ AC00 Rc(PT)/ AC20 Rc(PT)/ 8 AC50 Rc(PT) AC000 Rc(PT)/ 8 AC6000 Rc(PT) AC00 Rc(PT)/ 2 Precaution Be sure to read before handling. Refer to p.0-26 and 0-2 for Safety Instructions and common precautions on the products mentioned in this catalogue, and refer to p..0- and.0-2 for precautions on every series. Warning Selection qfor AC00, 0, 0 and with float style auto drain(n.o.), use 2.2kW or larger compressor. Because 2 auto drains are used and 200l/min air is needed, it might malfunction with a compressor weaker than the required ability. Caution qin case of mounting a regulator in up right direction, no pressure switch(is000m- ) attachment or T type interface can be mounted, for it touches bonnet. It is the same as a filter regulator. wthere is possibility of oil flowing back when mounting T type interface onto the supply side of lubricator and take out in the middle. It cannot be used for air non lubrication style. To use it as for air non lubrication style, it is necessary to use check valve(series AKM) to prevent reverse flow. emounting pressure switch and T type interface on the IN side of check valve makes it impossible to take out piping in the middle of check valve. rwhen mounting residual pressure release port valve directly to the IN side of a lubricator, use check valve (Series AKM) to prevent reverse flow of oil. tpressure switch and T type interface cannot be mounted to OUT side of residual pressure release port valve, as a part of the products interferes. Warning Caution Piping qwhen mounting check valve, make sure of the position of mark which indicates an entrance of air (IN side), and connect. Air Supply qif residual pressure release port valve is to be mounted, use an air filter 5µm filtration rating or less to prevent any damage on sheet part by dust, paper, etc. AC AV AU IR VEX SRP AMR M D ITV VBA.-6

AC000 to 6000 Pressure Characteristics Conditions: Supply pressure 0.MPa, Secondary pressure 0.2MPa, Flow 20l/min(ANR) AC000 M5 AC00-06 Rc(PT)/ AC2000 Rc(PT)/ AC00 Rc(PT)/ AC20 Rc(PT)/ 8 AC50 Rc(PT) AC000 Rc(PT)/ 8 AC6000 Rc(PT) AC00 Rc(PT)/ 2.-

AC000 to 6000 Dimensions AC000/2000 AC AV AU AC20/000/00/00/50/6000 Port size A B C D M N P R E F H J K L AC000 AC2000 AC20 AC000 AC00 AC00-06 AC00 AC50 AC6000 Option AC000 AC2000 AC20 AC000 AC00 AC00-06 AC00 AC50 AC6000 M5 / 8, / /, / 8 /, / 8 /, / 8, / 2 / /, 8 8 28 25 00 0 5 8.5 2.5 5 5 88 8.5 268 282 282 25.5 8 8 8.5 8 8 8 25 5 5 0 0 0 5 5 Barb fitting With drain guide Metal bowl B B B 6.5 6.5 6.5 8 26.5 20.5 20.5 5 5 5.5 2 288 288 8.5 25 66 66 20 202.5 28 25 25 26 56.8 60.8 60.8 65.5 6.5 5.5 5.5 8 25 0 0 0 0 Metal bowl with level gauge 86 86 22 222.5 0 5 5 Bracket mounting size 6 6 8 8 05 05 0 20 2 5 5.5 5.5 2 2 2.5 8.5 6 6 6 5 5 0 0 0.5 22.2.2 2.2 6.2 55.2 55.2 55.2 6 2 26 26 6 8.5 0.5 0.5 88 88 08 08 08 80 80 80 05 05 05 05 05 For piping adapter AC20, 000, port size /2: mm, For AC00, port size /: mm For options (with barb fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different. With auto drain Float Press. Diff. B 22 20.5 0.5 2.5 2.5 B 05.5 IR VEX SRP AMR M D ITV VBA.-8

Air Combination Filter Regulator + Lubricator AC00 to 0 JIS symbol AC00 AC200 AC00 Standard Specifications Combination equipment Port size auge port size (Rc(PT)) Fluid Proof pressure Max. operating pressure Filter regulator Lubricator Filter regulator Lubricator AC00 AC200 AC00 AC0 AC0-06 000 000 2000 2000 000 000 00 00 00-06 00-06 M5 /8 / / /8 / /8 /2 / /6 /8 /8 / / Air.5MPa.0MPa Set pressure range Ambient and fluid temperature Recommended lubricant Bowl material Construction/Filter regulator Weight (kg) Accessory (Standard equipment) Bowl guard Bracket (2) Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Note 2) For a set of pieces or more: L type bracket Attachments/Accessories (Options) Attachment Accessory Flow (l/min(anr)) (Port size) () Filtration Description Piping adapter Pressure switch with piping adapter Check valve () Residual pressure exhaust port valve Cross interface Interface.0MPa Pressure gauge 0.2MPa N.O. Auto drain float style (5) N.C. Auto drain pressure differential style 0.05 to 0. MPa 0(M5) 0.22 0.66 B0T B20T 0.05 to 0.85 MPa 0(/ ) 00(/8) 000(/2) 000(/) 5 to 60 C (Non-freezing) 5µm Turbin oil class (ISO V2) Polycarbonate Relieving style 0.8 B0T. B0T. B50T Part No. For AC00 For AC200 For AC00 For AC0 For AC0-06 E0-M5 E20-0 E0-0 E- 02 0 06 E- 06 IS000E- IS000E- 0 S000E- 2 2 0 Y 0 2 06 AKM2000-0 (02) AKM000- (0) AKM00- (02) VHS00- VHS2000-0 VHS000-0 Y-M5 Y2-0 Y- 0 Y- Y5-0 0 Y0 Y20 Y0 Y Y 2-0-R 6-0- 0 6-0- 0 6-0- 6-0- (2-0-R) () 6-2- 0 6-2- 0 6-2- 6-2- AD AD AD AD5 AD5 AD5 AD6 AD62 Note ) Standard specification of air combination: Port size without ( ) Note ) Substitute.0MPa type. -0, -02, -0, -0, -06, after part number indicate port size. (-0: /8, -02: /8, -0: /8, -0: /2, -06: /) Note 5) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 6) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauges..-

AC00 to 0 Dimensions AC00/200 AC AV AU IR AC00/0 VEX SRP AMR M D ITV VBA Port size A B C D E M N P R F H J K L AC00 AC200 AC00 AC0 AC0-06 Option AC00 AC200 AC00 AC0 AC0-06 M5 58 / 8, / 0 /, / 8 /, / 8, / 2 5 / 6 0.5 6.5 20.5 25 26.5 8 2.5 2 25 5 0 0 Barb fitting With drain guide Metal bowl 26 56.8 60.8 0.5 0.5 25 0 Metal bowl with level gauge B B B B 0.5 6.5 2.5 220.5 265 22 26.5 26.5 26 26.5 22 2.5 22 26.5 Bracket mounting size 2 5 58.5 82 20 2 5.5 5.5.5 8.5 5 5.5 22.2 2.2 6.2 6 2 26 6 8.5 0.5 88 88 80 80 05 05 With auto drain Float Press. Diff. B 28.5 00 0 B 0 8.5 For piping adapter AC00, port size /2: mm For AC0, port size /: mm For options (with barb fitting, with drain fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different..-0

Air Combination Air Filter + Regulator AC020 to 6020 AC20 AC020 AC2020 AC020 JIS Symbol Standard Specifications Air filter Regulator AC020 AC2020 AC2520 AC020 AC20 AC20-06 AC20 AC5520 AC6020 Combination Air filter 000 2000 000 000 00 00-06 00 6000 6000 equipment 000 2000 20 000 00 00-06 00 00 6000 Port size Attachment Accessory Regulator auge port size Fluid Proof pressure Max. operating pressure Set pressure range Flow (l/min(anr))(port size) () Ambient and fluid temperature Filtration Bowl material Construction/Regulator Weight (kg) Accessory Bowl guard (Standard equipment) Bracket (2) M5 /6 0.05 to 0. MPa 00 (M5 X 0.8) /8 / /8 Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Note 2) Set of or more than pieces: L type bracket Attachments/Accessories (Options) / / / /8 / /8 / /8 /2 /8 /8 / / / / / Air.5 MPa.0 MPa 0.05 to 0.85 MPa 5(/) 0(/8) 2000(/8) 00(/2) 00(/) 6000(/) 000() 8000() 5 to 60 C (Non-freezing) 5µm Polycarbonate Relieving style 0.2 0.5 0.68 0.82.6. 2.52 2.6 2.8 B0T B20T B0T B0T B0T B50T B60T B60T B60T Part No. Description For AC020 For AC2020 For AC2520 For AC020 For AC20 For AC20-06 For AC20 For AC5520 For AC6020 Piping adapter E0-M5 E20-0 E0-02 0 E0-02 0 E- 02 0 E- 06 E60-06 0 0 E60-06 06 0 E60-06 0 Pressure switch 2 with piping adapter IS000E- 02 0 IS000E- 02 0 Y IS000E- 02 IS000E- 0 2 02 0 0 Y 0 Y Y 2 0 0 06 Pressure switch IS000M-2Y IS000M-Y IS000M-Y IS000M-Y IS000M-5Y IS000M-6Y IS000M-6Y IS000M-6Y T type interface () Y-M5 Y2-0 (02) Y- (0) 02 Y- (0) 02 Y- (02) 0 Y5- (02) 0 Y6- (0) 0 Y6- (0) Y6-0 (0) 0 Residual press. exhaust port valve VHS00-02 VHS2000-0 0 02 VHS000-02 0 VHS000-02 0 0 Cross interface Y-M5 Y2-0 02 Y- 0 02 Y- 0 02 Y- 02 0 Y5-0 0 Interface Y0 Y20 Y0 Y0 Y Y Y60 Y60 Y60.0MPa Pressure 2-0-R 6-0- 0 6-0- 0 6-0- 0 6-0- 6-0- 6-0- 6-0- 6-0- gauge 0.2MPa (2-0-R) () 6-2- 0 6-2- 0 6-2- 0 6-2- 6-2- 6-2- 6-2- 6-2- Auto (5) N.O. AD AD AD AD AD AD AD drain float N.C. AD5 AD5 AD5 AD5 AD5 AD5 AD5 Auto drain press. differential AD6 AD62 Note ) Standard specification of air combination: Port size without ( ) Note ) Substitute.0MPa type. Note 5) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 6) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauge. -0, -02, -0, -0, -06, -0 after part number indicate port size. (-0: / 8, -02: /, -0: / 8, -0: / 2, -06: /, -0: ).-

AC020 to 6020 Dimensions AC020/2020 AC AV AU AC2520/020/20/20/5520/6020 Bracket mounting size Port size A B C D E M N P R F H J K L AC020 AC2020 AC2520 AC020 AC20 AC20-06 AC20 AC5520 AC6020 Option AC020 AC2020 AC2520 AC020 AC20 AC20-06 AC20 AC5520 AC6020 M5 / 8, / /, / 8 /, / 8 /, / 8, / 2 / /, 58 0 5 6 5 200 205 0 0.5 8.5 8.5 268 282 282 25 5.5.5 8 8 8 25 5 5 0 0 0 5 5 Barb fitting With drain guide Metal bowl 26 56.8 60.8 60.8 65.5 6.5 5.5 5.5 8 25 0 0 0 0 Metal bowl with level gauge B B B B 0 0.5 6 5 56 6 0.5.5 5.5 202.5 2 28 288 25 288 25 8.5 58.5 8 26.5 20.5 20.5 8 2.5 222.5 0 5 5 2 5 58.5 58.5 82.5 02.5 02.5 20 2 5 5.5 5.5 2 2 2.5 8.5 6 6 6 5 5 0 0 0.5 22.2.2 2.2 6.2 55.2 55.2 55.2 6 2 26 26 6 8.5 0.5 0.5 88 88 5.5.5 6 6 20 0 2.5.5.5.5.5 For piping adapter AC2520, 020, port size / 2: mm For AC20, port size / : mm For options (with barb fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different. With auto drain Float Press. Diff. B 8 225.5 20.5 0.5 2.5 2.5 B 0.5 26.5 IR VEX SRP AMR M D ITV VBA.-2

Air Combination Air Filter + Mist Separator + Regulator AC200 to 0 JIS symbol Standard Specifications Combination equipment Port size auge port size Fluid Proof pressure Max. operating pressure Min. operating pressure Set pressure range Flow (l/min (ANR)) () Air filter Mist separtor Regulator AC0 Ambient and fluid temperature 5 to 60 C (Non-freezing) Filtration : 5µm, M: 0.µm(5% scavening particle diameter) Density of oil mist on secondary side Max..0mgf/Nm ( 0.8ppm) (2) Bowl material Polycarbonate Construction/Filter regulator Relieving style Weight (kg) 0..0. 2.2 Accessory Bowl guard (Standard equipment) Bracket B20L B0L B0L B0L Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Rated flow changes depending on supply pressure Note 2) With compressor discharging density of 0mgf/Nm Air filter Mist Regulator separator AC200 AC250 AC00 AC0 AC0-06 2000 M2000 2000 000 M000 20 000 M000 000 00 M00 00 00-06 M00-06 00-06 /8 / / / /8 / /8 /8 /2 / /8 /8 /8 / / Air.5MPa.0MPa 0.05MPa 0.05 to 0.85MPa 200 00 00 Attachments/Accessories (Options) Part No. Description For AC200 For AC250 For AC00 For AC0 For AC0-06 Attachment Accessory.- Piping adapter Pressure switch with piping adapter Pressure switch T type interface () Residual pressure exhaust port valve Cross interface T type brcket Interface Pressure gauge Auto drain float style ().0MPa 0.2MPa N.O. N.C. Auto drain pressure differential style E20-0 2 0 2 2 IS000E- AC200 2.6 B50L IS000M-2Y IS000M-Y IS000M-Y IS000M-Y IS000M-5Y Y2-0 (02) E0-0 (0) Y- E0-0 (0) Y- B20T B0T B0T B0T B50T Y20 Y0 Y0 Y Y 6-0- 0 6-0- 0 6-0- 0 6-0- 6-0- 6-2- 0 6-2- 0 6-2- 0 6-2- 6-2- AD AD AD AD AD5 AD5 AD5 AD5 AD62 Note ) Standard specification of air combination: Port size without ( ). Note ) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 5) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT gauges. -0, -02, -0, -0, -06, after part number indicate port size. (-0: / 8, -02: /, -0: / 8, -0: / 2, -06: / ) Y VHS2000-0 Y2-0 IS000E- Y 0 VHS000- Y- 0 AC00 IS000E- Y 0 VHS000- Y- E- 0 06 IS000E- Y 0 06 (02) Y- VHS00-0 Y- E- 06 Y5-0 (02) Y5- Y5-0

AC200 to 0 Dimensions AC200 AC AV AU IR AC250/00/0 VEX SRP AMR M D ITV VBA Port size A B C D E M N P F H J K L AC200 AC250 AC00 AC0 AC0-06 Option AC200 AC250 AC00 AC0 AC0-06 8,, 8, 8, 8, 2 8 8 28 25 0.5 8.5 8.5 25 5.5.5 5 5 0 0 Barb fitting With drain guide Metal bowl 56.8 60.8 60.8 65.5 6.5 0 Metal bowl with level gauge B B B B 0.5 6 5 56 6 0.5.5 5.5 202.5 8.5 58.5 8 8 2.5 222.5 Bracket mounting size 6 6 8 8 2 5 5 5.5 8.5 5 22.2.2 2.2 6.2 2 26 26 6 0.5 0.5 88 88 With auto drain Float For piping adapter AC250, 00, port size 2: mm For AC0, port size : mm For options (with barb fitting, with drin guide, metal bowl, with level gauge), body length (B dimension) is different. Press. Diff. B B 26.5 8 225.5 20.5.-

Air Combination Filter Regulator + Mist Separator AC20/0/ JIS symbol AC20 Standard Specifications AC AC0 Filter regulator Mist separator Combination equipment Port size auge port size Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Filter regulator Mist separator Set pressure range Flow (l/min (ANR))(Port size) () Density of oil mist on secondary side Bowl material Construction/Filter regulator Weight (kg) Accessory (Standard equipment) Bowl guard Bracket () AC20 AC0 AC AC-06 2000 M2000 000 00 M000 M00 /8 / / /8 / /8 / 2 / /8 /8 / / Air.5MPa.0MPa 0.05MPa 0.05to0.85MPa 0 800 800 5 to 60 (Non-freezing) : 5µm, M: 0.µm(5% scavenging particle diameter) Max.0mgf/Nm ( 0.8ppm) (2) Polycarbonate Relieving style Note ) Conditions: Supply pressure 0.MPa, Set pressure 0.5MPa Rated flow changes depending on supply pressure. Note 2) With compressor discharging density of 0mgf/Nm Note ) L bracket for a set of pieces or more. 0.6 B20T 00-06 M00-06 Attachments/Accessories (Options) Part No. Description For AC20 For AC0 For AC For AC-06 Attachment Accessory.-5 Filtration Piping adapter Pressure switch with piping adapter Residual pressure exhaust port valve Cross interface Interface Pressure.0MPa gauge 0.2MPa Auto drain float style () N.O. N.C. Auto drain pressure differential style E20-0 0. B0T E0-0 2 0 IS000E- 2 2 Y IS000E- Y VHS2000-0. B0T E- 0 06. B50T E- 06 Note ) Minimum operating pressure: N.O. 0.MPa, N.C. 0.5MPa Note 5) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). (PF) pressure gauge is unavailable. Consult SMC for NPT pressure gauges. -0, -02, -0, -06 after part number indicate port size. (-0: / 8, -02: /, -0: / 8, -0: / 2, -06: / ) 0 VHS000- IS000E- Y 0 06 VHS00-0 Y2-0 Y- 0 Y- Y5-0 Y20 Y0 Y Y 6-0- 0 6-0- 0 6-0- 6-0- 6-2- 0 6-2- 0 6-2- 6-2- AD AD AD AD5 AD5 AD5 AD62

AC20/0/ Dimensions AC20 AC AV AU IR VEX AC0/ SRP AMR M D ITV VBA Bracket mounting size Port size A B C D E M N P F H J K L AC20 AC0 AC AC-06 / 8, / /, / 8 /, / 8, / 2 / 0 5 6 6.5 20.5 25 26 8 2.5 2 5 0 0 56.8 60.8 0.5 0.5 0 5 58.5 82 2 5 5.5 8.5 5 22.2 2.2 6.2 2 26 6 0.5 88 88 With auto drain Float Press. Diff. B 28.5 00 0 B 8.5 Option AC20 AC0 AC AC-06 Barb fitting With drain guide Metal bowl 26 26.5 22 Metal bowl with level gauge B B B B 6.5 2.5 220.5 265 22 26.5 26.5 2.5 22 26.5 For piping adapter AC0, port size / 2 : mm For AC, port size / : 5mm For options (with barb fitting, with drain guide, metal bowl, with level gauge), body length (B dimension) is different..-6

Attachments Piping Adapter M5, / 8, /, / 8, / 2, /, Easy maintenance. Makes it possible to attach and detach equipment without removing piping. E0-02 Piping adapter To order piping adapter with bracket, the parts number as shown below. (Example) With L type bracket: E 0L- With T type bracket: E 0T- One with AC installed is special product. Port size A B C Applicable model E0-M5 E20-0 E20- E20- E0- E0- E0-0 E- E- E- 0 E- 06 E- 06 E60-06 E60-0 M5 6 / 8 / 2 / 8 / 26 / 8 / 2 / / 8 / 2 / / / 6 22 2 2 5 5 5.5 AC0 0, 000 000, 000, 000 AC20 0 22 2000, 2000, 2000 2000, M2000, D2000.2 AC25 0, AC0 0 000, 000, 000.2 000, M000, D000 2.2 2.2 6.2 55.2 AC 0 00, 00, 00 00, M00, D00 AC 0-06 00-06, 00-06, 00-06 00-06, M00-06, D00-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 00, 00, 00 6000, 6000, 6000 Note ) in part number indicates thread type. Use nothing for Rc(PT), N for NPT and F for (PF). T Type Interface: (T) M5, / 8, /, / 8, / 2 Makes it easy to diverge air out with T type interface. Y Y Caution on Assembling T type interface T type interface cannot be mounted at IN/OUT side of or upward handle of. When T type interface is used at IN side of lubricator, oil may have entered. Use check valve series AKM. Port size A B C Applicable model Y-M5 M5 8 8 2 AC000, AC020 Y2-0 / 8 0 2 AC2000, AC2020, 200 Y2- / Y- 0 / 8 AC20, AC2520, AC250 Y- / AC000, AC020, AC00 Y- / 2 AC00, AC20, AC0 Y- / 8 Y5- / AC00-06, AC20-06 Y5-2 / 8 AC0-06 Y6- / 8 AC00, AC50, AC6000 Y6-0 5 0.5 / 2 AC20, AC5520, AC6020 When T type interface with bracket is required, order as example below. (Example) With L bracket: Y L- With T bracket: Y T- Refer to a table of attachment on P..- for standard port size when applying to AC. in part number indicates thread. Use nothing for Rc(PT), N for NPT and F for (PF)..-

Attachments Pressure Switch with Piping Adapter JIS symbol Specifications Fluid Proof pressure Max. operating pressure Set pressure range (off) Differential Ambient and fluid temperature Switch Characteristics Contact point structure Max. contact point capacity Voltage AC, DC Max. operating current How to Order IS000E 0 YL Air.0MPa 0.MPa 0. to 0.6MPa 0.08MPa 5 to 60 C (No condensation) a 2V AC/2W DC 2V, 2V, 8V, 00V AC, 2V to 2V DC: ma AC, 8V DC: ma AC, 00V DC: 20mA Q () Port size IS000E-2 0Y / 8 IS000E-2Y / IS000E-2Y / 8 IS000E-Y / IS000E-Y / 8 IS000E- 0Y / 2 IS000E-Y / IS000E-Y / 8 IS000E- 0Y / 2 IS000E- 06Y A B C D 28 62 8.5 26 80 6 6.5 80 6.5 8 66.5 Applicable model AC2000, AC200, AC2020 AC200, AC20 2000 AC20, AC2520, AC250 AC000, AC00, AC020 AC00, AC0 000, 0 AC00, AC0, AC20 AC0, AC 00, (2) / 8 66.5 Note) in the part number indicate a connecting thread. Use nothing for Rc(PT), N for NPT and F for (PF). Note2) Can NOT be mounted on "AC 0-06" and " 0-06". With retainer, O ring and bolt. Consult SMC when mounting the pressure switch on "AC 0-06" and " 0-06". For more information, refer to p..0-0. AC AV AU IR VEX SRP AMR M D ITV VBA Pressure switch with piping adapter 2 N F Body size For AC2000 For AC20, AC000 For AC00-02 to 0 Thread Rc(PT) NPT (PF) Attachment Y YL YT Piping adapter port size 0 02 0 0 06 Options X20 Length of lead wire: m X202 Setting pressure range: 0. to 0.6MPa X25 Length of lead wire: m, (0. to 0.6MPa) Without attachment With attachment With attachment and L type bracket With attachment and T type bracket / 8 / / 8 / 2 / Attachments for IS000E Pressure switch applicable model No. IS000E-20 to 20 IS000E-02 to 0 IS000E-2 to 6 Y type standard Y20E Y0E YE YL type with L type bracket Y20LE Y0LE YLE YT type with T type bracket Y20TE Y0TE YTE.-8

Attachments Check Valve: (K) Rc(PT) / 8, /, /8 Diverges on the secondary side of regulator. Makes it easier to mount check valve with a middle take out port which prevents reverse flow of lubricant oil from lubricator when releasing air. Check valve AKM000 JIS symbol Specifications AKM2000 AKM000 AKM00 Note) Use this check valve when diverging on the supply side of. IN/OUT port is not made for thread piping. How to Order E AKM Check valve Body size 20 / 8 0 / 8 / 2 Ordering source area code Japan, Asia - Australia E Europe N North America Effective area (mm 2 ) 28 55 0 00 F 0 Thread N F Rc(PT) NPT (PF) Diverging port size 0 / 8 02 / 0 / 8 Diverging port size AKM2000 / 8, / AKM000 / 8, / AKM00 /, / 8 A B 28 5 8 Applicable model AC2000, AC200 AC20, AC250 AC000, AC00 AC00, AC0 () Note ) Not applicable to AC 0-06. Refer to the attachment list on p..- for standard diverging port size when applying to AC. C D E 0 5 2 8 5 Caution on Assembling Pressure switch and T type interface can not be mounted on the IN side. Piping adapter E0-M5 E20-0 to0 E0-02 to0 E-02 to06 E-06 E60-06.0 Pressure switch with piping adapter IS000E-20 to 20 IS000E-02 to 0 IS000E-2 to 6.-

Attachments Pressure Switch: (S) Compact pressure switch can be mounted easily. Makes it easier to detect pressure in lines. Pressure switch Specifications Fluid Proof pressure Max. operating pressure Set pressure range (off) Differential Ambient and fluid temperature Switch Characteristics Contact point structure Max. contact point capacity Voltage AC, DC Max. operating current For more information, refer to SMC Pressure switch catalog. (Catalog No.E82) How to Order IS000M YT Air.0MPa 0.MPa 0. to 0.6MPa 0.08MPa 5 to 60 C(No condensation) a 2V AC/2W DC 2V, 2V, 8V, 00V AC, 2V to 2V DC: ma AC, 8V DC: ma AC, 00V DC: 20mA Q JIS symbol IS000M-2Y IS000M-Y IS000M-Y IS000M-5Y IS000M-6Y A B C D E F 5.5 62.6 2 28 0 5 82 6. 2 2 5 5 5 88. 6.6 68 00 2.5 2 2 2 5 5 5 Caution on Assembling Applicable model AC2000, AC2020, AC200 AC20, AC2520, AC250 AC000, AC020, AC00 AC00, AC20, AC0 AC00-06, AC20-06 AC0-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 Attachment for pressure switch can be installed at the IN/OUT side of,,, M and D. Mounting at the IN/OUT side of and upward handle of is not possible. AC AV AU IR VEX SRP AMR M D ITV VBA Pressure switch 2 5 6 Body size For AC2000 For AC20, AC000 For AC00-02 to 0 For AC00-06 For AC00, AC6000 Attachment Y YL YT Options X20 X202 X25 Length of lead wire: m Set pressure range: 0. to 0.6MPa Length of lead wire: m,(0. to 0.6MPa) Without attachment With attachment With attachment and L type bracket With attachment and T type bracket Attachments for IS000M Pressure switch applicable model No. IS000M-2 IS000M- IS000M- IS000M-5 IS000M-6 Y type standard Y20M Y0M YM YM Y60M YL type with L type bracket Y20LM Y0LM YLM YLM Y60LM YT type with T type bracket Y20TM Y0TM YTM YTM Y60TM.-20

Attachments Cross Interface M5, /8, /, / 8, / 2 Make it possible to diverge piping in all directions. Note) IN/OUT port is not machined for thread piping. Cross interface Cross interface Y-M5 Y2-0, 02 Y-0, 02 Y-02, 0 Y5-0, 0 Residual Pressure Exhaust Port Valve: (V) Residual pressure exhaust port valve makes it easier to exhaust pressure. Residual pressure exhaust port valve E: -Rc(PT) F: Without thread Port size A B C D Applicable model Y-M5 M5 2 6 25 AC000, AC00, AC020 Y2-0 8 AC2000, AC200, AC2020 Y2-22 AC200, AC20 Y- 0 AC20, AC2520, AC250 8 Y- 28 8 AC000, AC00, AC020 AC00, AC0 Y- AC00, AC0, AC20 Y- 60 8 6 5 8 AC0, AC Y5-8 2 62 Y5-0 2 AC-06 Note ) in parts number indicates thread. Use nothing for Rc(PT), N for NPT and F for (PF). 62 Caution on Assembling AC00-06, AC0-06 AC20-06, AC0-06 When mounting directly onto the IN side of lubricator, use check valve series AKM between the interface and lubricator. Installation to AC will be available as a special product. Please consult SMC. Specifications Port size Effective area (mm 2 ) IN to OUT OUT to EXH VHS2000 VHS000 8 0 6 8 6 2 VHS00 8 2 22 8 5 5 2 5 Note) Use air filter on the IN side to protect operation. How to Order E.-2 VHS Residual pressure exhaust port valve Ordering source area code Japan, Asia - Australia E Europe N North America 0 00 F 02 Body size 20 8 0 8 2 Thread N F Port size 0 8 02 0 8 0 2 Rc(PT) NPT (PF) IN/OUT Port size EXH Port size A B C VHS2000 8, 8 56 6 28 22 25 VHS000, 8 5 5 8 28 0 () VHS00, 8, 2 8 0 80 8 5 6 0 Note ) NOT applicable to AC 0-06. Caution on Assembling Pressure switch and T type interface can not be mounted to OUT side of residual pressure exhaust port valve. D E F

Interface/Bracket Accessories Interface AC AV AU Y0 Y0 Y20 Y0 Y Y Y60 A 8 0 5 Applicable model AC000 to AC020 AC2000 to AC20 AC20 to AC25 AC000 to AC0 AC00 to AC AC00-06 to AC-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 IR VEX SRP AMR L Bracket/ Interface with L Bracket M D ITV VBA Interface with L bracket L bracket L bracket Interface with L bracket A B C D E F R L Applicable model B0L B20L Y0L Y20L 20 2 2 5.5 5.5 25 0 5 6 8 0 2.25 2.5 2 AC000 to AC020 AC2000 to AC20 B0L B0L B50L Y0L YL YL 5 6 22 22.5.5.5 5 60 AC20 to AC25 AC000 to AC0 AC00 to AC AC00-06 to AC-06 B60L Y60L 2 2 0 0 5 6 62.5 AC00, AC50, AC6000 AC20, AC5520, AC6020.-22

Accessories T Bracket/ Interface with T Bracket Interface with T bracket T bracket T bracket B0T B20T B0T B0T B50T B60T Interface with T bracket Y0T Y20T Y0T YT YT Y60T A B C D E F H R 20 2 5 2 5 6 22 22 2.5 5.5 2 25 0 0 5 5 0 8 0 5 8 0 80 80 00 2.25 2.5.5.5.5 6 L 2 5 62.5 Applicable model AC000 to AC020 AC2000 to AC20 AC20 to AC25 AC000 to AC0 AC00 to AC00-06 to AC-06 AC00, AC50, AC6000 AC20, AC5520, AC6020 Bracket For / For M/D For B B2 B2A BA BA B5A B6A A B C D F H J K L M N R 5 0 0 0 2 5 5 66 6 2 52 8.5 6.5 26 8.5 5.5 8 2.5 5.5 65 2 22.5.5 5.5 2 2 2 8. 8 0.5 0.5 20 20 0 5. 6.5.25 2. 8.5.25 2. 8.5.25 2. 2. 5.5 t 2..2 Mounting thread M X 8 l (Round head Phillips screw) M X 8 l (Hexagon socket head cap screw) M5 X 0 l (Hexagon socket head cap screw) M5 X 0 l (Hexagon socket head cap screw) M6 X 0 l (Hexagon socket head cap screw) Applicable model 2000, 2000 M2000, D2000 000, 000 M000, D000 00, 00 M00, D00 00-06, 00-06 M00-06, D00-06 00, 6000 00, 6000, 60, 6060 00, 6000 With 2 mounting screws..-2

Accessories Bracket/For / AC B220 AV AU Bracket/For, B20 B220 B20 B20 A B C D F øh J K L N R t B20 28. 25 20.5 2. 2 6.5.5 2.25 2 B220 55 25 0.5 20 0 5. 5. 2. 2. B20 5 2.5 66 2.5 25.5 8 6.5.25 2. Appliable model 000, 000 2000, 2060 20, 25, 2560 2000, M2000 D2000 000, 0, 060 P000, 000, 0 M000, D000 IR VEX SRP B20 0 5 2 8 80 52.5 0 2 0.5 8.5.25 2. 00, 00-06,, -06, 60, 60-6 00, 00-06, -06 M00, D00 AMR M D ITV VBA.-2