The Benefits of Gravimetric Sample Preparation

Similar documents
Quantos GraviPrep. Bye Bye, ml Hello, Quantos

Comparing the MICROLAB 600 to Volumetric Glassware and Air Displacement Pipettes. June 2011

Comparing the Microlab 600 to Volumetric Glassware and Air Displacement Pipettes. January 2013

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Automated Sample Preparation in Quality Control of Eye-Drop Formulation

The Uncertainty of Reference Standards

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Sulfotepp impurities in Chlorpyrifos EC formulations

Application Note. Automated pipetting and analysis of polymer suspensions for process control in chemical production

INTERNATIONAL CHEMISTRY TESTING. 258 Main Street- Suite 311- Milford, MA Tel: Fax:

The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications

HPLC Praktikum Skript

Fast methods for the determination of ibuprofen in drug products

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Calculations. Quantities, Dilutions and Concentrations. Pharmacy Technician Training Systems Passassured, LLC

Quality control analytical methods- Switch from HPLC to UPLC

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Chapter 4: Verification of compendial methods

Certified Reference Material - Certificate of Analysis

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

HPLC Sample Preparation

Elemental Scientific. Spike Recovery. Elemental Scientific

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

Lecture 22: PHARMACY CALCULATIONS for Technicians Preparing Injectable Medications

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

Karl Fischer Titration Of Food : Towards Complete Automation

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

ALA 2008 Workshop Abstract

AUTOMATED FORMULATION SYSTEMS

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

DI 3500 Discrete Aoalvzer

Metrological Methods for Low Volume Liquid Handling in Drug Delivery and In-Vitro Diagnostics

Measurement Uncertainty, March 2009, F. Cordeiro 1

Analysis of domestic sludge using the Agilent 4200 MP-AES

Chapter 13. Titrations in Analytical Chemistry

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Procedure for the Determination of Permanganate Oxidizable Carbon

LAB 15. Traceability: Volumetric Apparatus. Edition 3 February 2019 Draft for Consultation. LAB 15 / Issue: 3 Page 1 of 12

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

MOLAR CONCENTRATION. - unit: MOLARITY (M): moles of dissolved substance per LITER of solution. molarity

Limit-test of NDMA and NDEA in Sartans. by GC-MS (Liquid-direct-injection)

Shedding a Light on Solubility Measurement and Prediction Solubility Sub Team's Story to Date

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Certified Reference Material - Certificate of Analysis

Particle Analysis at the Touch of a Button. Litesizer series

White Paper. Perform Conductivity Measurements In Compliance with USP <645>

Simplifying the Process: Automated USP 643 / EP

MultiVap8: Automated concentration system

Accuracy and Precision of Laboratory Glassware: Determining the Density of Water

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Materials: Micropipettes (2-20 µl range pipette, µl range, µl range), tips, test tubes with color dye, well plates

What actually are dietary supplements? They are consumed in large quantities, but they

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Chemistry Calibration of a Pipet and Acid Titration

Example: How would we prepare 500. ml of M sodium sulfate in water?

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

H 3 CO H 3 CO S CH 3

Practice Lab. Balances and calibration of volumetric tools

What is measurement uncertainty?

á233ñ ELEMENTAL IMPURITIES PROCEDURES

A. GENERAL NOTICES. Ninth Edition, which may be abbreviated as JSFA-IX.

Relative Response Factor for Lamivudine and Zidovudine Related substances by RP-HPLC with DAD detection

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Automated determination of the uniformity of dosage in quinine sulfate tablets using a fiber optics autosampler

Focus Series Peptide Synthesizers

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Technical Procedure for Measurement Assurance

Making Measurements. Units of Length

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

LC Technical Information

GC Application Note. Dilution/standard addition: Efficient and traceable.

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

CHM101 Lab Measurements and Conversions Grading Rubric

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Certificate of Analysis

White Paper. Moisture Analyzer Routine Testing

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

LAB EXERCISE: Basic Laboratory Techniques

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

COEFFICIENTS. - Experimentally, we can usually determine the reactants and products of a reaction

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 03: EXPERIMENTAL ERROR

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Elemental Scientific. Spike Recovery. Elemental Scientific

Assurance and Quality Control in Manufacturing Process Validation of powder for Extemporaneous Oral Suspension

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Recent Advances to Improve Chemical Development

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

White Paper. Electrostatic Charges in Weighing Innovative Detection Solution. Summary

Analytical Chemistry

Transcription:

The Benefits of Gravimetric Sample Preparation Improving the Efficiency and Quality of Analytical Workflows Dr. Joanne Ratcliff and Dr. Jan Prochnow, Mettler-Toledo AG Analytical sample and standard preparation in a pharmaceutical or QA/QC laboratory is typically a manual procedure that requires that solids be weighed and diluted to the mark volumetrically. A minimum of 50 ml of solution is usually prepared for analytical measurements, even though the amount required for each injection is merely a fraction of this. More than 99.9 % of a prepared solution is typically disposed of as waste. Automation of this workflow provides the opportunity to reduce the impact of human variability and uncontrolled environmental factors. Adding the liquid gravimetrically improves precision and reduces solvent and substance consumption by more than 75 %. 38 q&more 01.12

Photo: istock.com Olena Chernenko q&more 01.12 39

Traditional sample preparation technique The traditional protocol for preparing an analytical sample or standard is to weigh out the specified amount of subs tan ce manually on an analytical balance. The substance is then transferred to a volumetric flask and diluted to the mark by filling with the appropriate amount of solvent. 50 ml or 100 ml volumetric flasks are typically used because the larger the flask, the lower the relative error even though the required amount for today s analytical methods is only a fraction of this. Modern HPLC or UHPLC (ultra high-performance liquid chromatography) instruments typically require 10 20 microliters per injection. Hence, more than 99.9 % of prepared solutions are disposed of without ever being used. The reason for this excess is a combination of two factors: limitations in the minimum weight of powder that can be dosed on a specific analytical balance, and constraints in liquid dosing using volumetric glassware. Measurement Uncertainty and Minimum Weight An analytical balance has a specific minimum weight according to USP regulations. This means that there is a lower limit on the amount of solid that can be weighed in order to ensure that the required accuracy is achieved. The relative measurement uncertainty of any balance is a hyperbolic function of the weight on the balance (Fig. 1). There is a point where the uncertainty of the measurement becomes too high to have sufficient confidence in the accuracy of the weighed amount. This point is referred to as minimum sample weight or minimum weight. Relative measurement uncertainty [%] (= Absolute measurement uncertainty / weight) Uncertainty U [mg or %] Accuracy limit: Minimum sample weight Weight [g] Absolute measurement uncertainty [mg] Weighing accuracy [%] Max This minimum weight is determined by the repeatability of the measurement but it varies due to changing environmental conditions, such as vibrations or draft, and the skill of the operator. Therefore, it is recommended that a safety factor of typically 2 or 3 is applied, depending on how stable the conditions or critical the applications. The safety factor is a multiplier. For example, a minimum weight of 10 mg with an applied safety factor of 2, means that 20 mg is the smallest amount that should be weighed to meet the accuracy requirements. Constraints of Volumetric Flasks Being constrained to Class A volumetric glassware may force an analyst to use more substance than necessary because they are limited to the specific intervals of the flasks. In most cases the amount of substance weighed is rounded up to match the volumetric flask size available. If the diluent is weighed instead, there is no size limitation and the minimum amount of solvent can be delivered gravimetrically to achieve the desired concentration. Typical concentrations in the pharmaceutical industry require several milliliters of solvent, which is equivalent to several grams in weight. Quantifying these amounts on an analytical balance can be done with very high accuracy due to a negligible measurement uncertainty contribution. This is because the weight of solvent required is typically several orders of magnitude higher than the minimum sample weight, and the uncertainty decreases hyperbolically with the net weight (see Figure 1). Weighing both the sample and the solvent instead of using a volumetric flask improves reproducibility and traceability and minimizes problems associated with volumetric glassware. The vials in which the samples are prepared can be small and disposable, which eliminates concern about potential cross-contamination. Hidden costs of washing of volumetric flasks and waste disposal are also reduced. Saving Substance and Solvent As discussed earlier, the minimum sample weight and the safety factor depend strongly on the user and environmental influences. Automated powder dispensing with the Quantos system can reduce environmental and user variations, and thus significantly reduce both the mini- Fig. 1 Relative measurement uncertainty decreases hyper bolically with net weight. Accuracy limit is the Minimum Weight 40 q&more 01.12

mum sample weight and the recommended safety factor. For automated dosing, a safety factor of 1.5 can be applied, providing conditions are stable. For example, according to USP regulations, the XP205 analytical balance has a minimum weight of typically 21 mg and a recommended safety factor of 2. The Quantos automated dosing balance has a minimum weight 8 mg and a recommended safety factor of 1.5. If a 1.0 mg/ml solution with a 1 g/ml density is prepared manually using a volumetric flask, 50 mg of substance and 50 ml of solvent are required. When the solution is prepared by the automated gravimetric method, 12 mg of substance and 12 ml of solvent are sufficient. A materials saving of 76 % can be realized whilst remaining compliant with USP regulations. This has a significant impact on the cost of compliance. Figure 2 illustrates how the minimum weight, the concentration, and the available flask size determine the amount of substance and solvent needed. The red and green lines show the consumption of solvent as a function of the target concentration for the volumetric and gravimetric methods respectively. The consumption of substance is also proportional. The red line on the graph demonstrates that with the volumetric approach only at four discrete concentrations (horizontal sections) can the minimum net sample weight of 42 mg be weighed. In all other cases, significantly more solvent is consumed because the amount of substance needs to be rounded up to the next flask available. The green line indicates that when the diluent is weighed gravimetrically the minimum net weight of substance can be used at every target concentration (represented by a smooth curve). No rounding up to the next flask size available is necessary. When quantifying solvent by its weight rather than volume, the corresponding amount of solvent can be dispensed to match the desired concentration. 100 ml 100 ml Analytical balance 21 mg (minweigh) x 2 (safety factor) = 42 mg Quantos 8 mg (minweigh) x 1.5 (safety factor) = 12 mg 50 ml 50 ml solvent volume 5x substance solvent waste Factor 2 in consumption 25 ml 10 ml 0 ml 0 mg/ml 2.5 mg/ml 5 mg/ml concentration prepared Fig. 2 Solvent consumption as a function of the desired concentration: volumetric method (red line); gravimetric method (green line) q&more 01.12 41

Joanne Ratcliff is a Product Manager at Mettler-Toledo for the Quantos Automated Dosing Solutions Business Unit for 13 years. Her key areas of expertise are automated weighing, powder dispensing and sample preparation. She has a degree in Chemistry with Analytical Science and a Ph.D. in Physical Organic Chemistry using Analytical Methods from the University of Swansea in Wales. Jan Prochnow, Ph.D. in Physics, is Head of Product Management and Business Development, Quantos Business Unit at Mettler-Toledo in Greifensee, Switzerland. Reproducibility of Sample Concentrations Automated gravimetric powder and liquid dispensing produces very reproducible concentrations. To demonstrate this, nine solutions of an active pharmaceutical ingredient (API) were prepared individually, by automated and manual methods. The solutions were analyzed by HPLC to measure the reproducibility. Nine solutions with a target concentration of 0.603 mg/g were prepared. Ten milligrams of an API was dispensed automatically into nine 20 ml brown glass vials. Automation allowed 10 mg to be dispensed with accuracy to within an RSD of only 0.89 %. Then, the diluent an 80:20 mixture of acetonitrile and water was added gravimetrically based on the exact weight of the API dispensed into each vial. The RSD of the concentrations achieved was 0.001 %. Next, a 2 µl sample was injected into the HPLC system. The peak areas for the nine individually automatically prepared samples varied with an RSD of 0.19 %; the peak areas for the individually manually prepared samples varied with an RSD of 0.60 %. To highlight the reproducibility of the sample preparation procedure and eliminate the variability contribution of the HPLC injector, 10 repeat injections of the same solution were also analysed. When the same sample was injected 10 times, the peak areas varied with an RSD of 0.21 %. When sample preparation is automated by weighing the substance and the solvent, the results are extremely reproducible. The variability in the prepared solutions is insignificant because it is lower than the variability of the analytical instrumentation itself. Conclusion The use of volumetric flasks and manual powder weighing results in excessive use of solvent and substance. Until now, 99.9 % of prepared solutions are disposed of without being used. Automated gravimetric sample and standard preparation reduces the minimum weight of the balance and eliminates the need for volumetric flasks, therefore significantly reducing the amount of solvent and substance consumed. Therefore the cost of compliance is significantly reduced. Concentrations can be determined with very high accuracy which makes the process more reproducible and improves the quality of analytical results. Joanne.Ratcliff@mt.com jan.prochnow@mt.com For more information: www.mt.com/q-sampleprep 42 q&more 01.12