Maha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C

Similar documents
Mason Technology Ltd

Mason Technology Ltd

Saolta University Health Care Group Galway University Hospital

Document No: TR 12 Issue No: 1

R SANAS Page 1 of 7

Forensic Science Ireland

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

CALIBRATION CERTIFICATE # 503

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ESTA governance Quality Assurance System for Seed Treatment and Treated Seed

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation to ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

CERTIFICATE OF CALIBRATION

CERTIFICATE OF CALIBRATION

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

Certificate of Accreditation

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

The Fundamentals of Moisture Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone:

Demonstrate knowledge of a track warrant control (TWC) system

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

A2LA. G118: Guidance for Defining the Scope of Accreditation for Calibration Laboratories

IMPORTANT FEATURES OF ESTIMATION & INTERPRETATION OF MEASUREMENT UNCERTAINTY. B. Bhattacharya, K. Ramani, P.H. Bhave

Certificate of Accreditation

Manual stack emissions monitoring Performance Standard for laboratories carrying out analysis of samples

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Method Validation and Accreditation

Part 5: Total stations

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

This document is a preview generated by EVS

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

ISO INTERNATIONAL STANDARD. Surface chemical analysis X-ray photoelectron spectroscopy Repeatability and constancy of intensity scale

g/cm³ DAkkS Calibration Laboratory for Temperature and Density High-precision calibration for temperature and density

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

Annex I to Resolution 6.2/2 (Cg-XVI) Approved Text to replace Chapter B.4 of WMO Technical Regulations (WMO-No. 49), Vol. I

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

INSPIRE Monitoring and Reporting Implementing Rule Draft v2.1

ISO Water quality Measurement of polonium 210 activity concentration in water by alpha spectrometry

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

ISO INTERNATIONAL STANDARD. Rolling bearings Thermal speed rating Calculation and coefficients

Test Report EN (2008)

Certificate of Accreditation

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

Certified Reference Material

The Determination of Uncertainties in Bend Tests on Metallic Materials

Contents. Ipswich City Council Ipswich Adopted Infrastructure Charges Resolution (No. 1) Page

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Revision of CMM performance specifications

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Specific Accreditation Guidance

CERTIFICATE OF ACCREDITATION

ISO INTERNATIONAL STANDARD

Withdrawn at December 31, Guideline DKD-R 5-7. Calibration of Climatic Chambers DEUTSCHER KALIBRIERDIENST

Uncertainty of Measurement A Concept

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

WGFF Guidelines for CMC Uncertainty and Calibration Report Uncertainty

ISO INTERNATIONAL STANDARD. Rolling bearings Linear motion rolling bearings Part 2: Static load ratings

QUALITY ASSURANCE AND QUALITY CONTROL IN CHEMICAL AND PHYSICAL ANALYSIS

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

ISO/IEC requirements. General matters of quality system, requirements for documentation and the list of the documents required for a

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

Part 14: Water quality Sampling. Guidance on quality assurance and quality control of environmental water sampling and handling

ISO INTERNATIONAL STANDARD. Particle size analysis Laser diffraction methods. Analyse granulométrique Méthodes par diffraction laser

Calibration Traceability Guidelines

Guide to Registration Requirements for Active Substance Manufacturers, Importers and Distributors in Ireland

Comparison protocol EURAMET project

Certificate of Accreditation

Calibration, traceability, uncertainty and comparing measurement results. Workshop 16 March 2015 VSL, Delft The Netherlands

CALIBRATION REPORT FOR THERMOHYDROMETER

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

World Meteorological Organization

Calibration of Surface Contamination Monitors. UKAS Accredited Organisations Comparison. Final Report

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 5: Determination of the noise emission

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Transcription:

629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin Calibration Laboratory Registration number: 287C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule bearing the Registration Number detailed above, in compliance with the International Standard ISO/IEC 17025:2005 2 nd Edition General Requirements for the Competence of Testing and Calibration Laboratories (This Certificate must be read in conjunction with the annexed Schedule of ) Date of award of accreditation: 31:05:2011 Date of last renewal of accreditation: 01:12:2015 Expiry date of this certificate of accreditation: 01:12:2020 This shall remain in force until further notice subject to continuing compliance with INAB accreditation criteria, ISO/IEC 17025 and any further requirements specified by the Irish National Board. Manager: Dr Adrienne Duff Chairperson: Mr Tom O Neill Issued on 01 December 2015 Organisations are subject to annual surveillance and are re-assessed every five years. The renewal date on this Certificate confirms the latest date of renewal of accreditation. To confirm the validity of this Certificate, please contact the Irish National Board. INAB is a signatory of the European co-operation for (EA) Testing Multilateral Agreement (MLA) and the International Laboratory Cooperation (ILAC) Mutual Recognition Arrangement. Edition 12, 03/08/2017 287C Page 1 of 7

Schedule of (Annex to Certificate) test equipment: Category D MAHA IRELAND LTD Initial Date : 31-May-2011 Postal Address: 629 Jordanstown Avenue Greenogue Business Park Rathcoole Co. Dublin Ireland Telephone: +353 (1) 4587548 Fax: +353 (1) 4587552 E-mail: sales@mahaireland.ie Contact Name: John Mallon Facilities: Public calibration service Edition 12, 03/08/2017 287C Page 2 of 7

Schedule of THE IRISH NATIONAL ACCREDITATION BOARD (INAB) is the Irish body for the accreditation of organisations including laboratories. Laboratory accreditation is available to testing and calibration facilities operated by manufacturing organisations, government departments, educational institutions and commercial testing/calibration services. Indeed, any organisation involved in testing, or calibration in any area of technology can seek accreditation for the work it is undertaking. Each accredited laboratory has been assessed by skilled specialist assessors and found to meet criteria which are in compliance with ISO/IEC 17025 or ISO 15189 (medical laboratories). Frequent audits, together with periodic inter-laboratory test programmes, ensure that these standards of operation are maintained. Calibration Categories: Category A: Permanent calibration laboratory where the laboratory is erected on a fixed location for a period expected to be greater than three years. Category B: Category C: Category D: Site calibration that is performed by staff sent out on site by a permanent laboratory that is accredited by the Irish National Board. Site calibration that is performed in a site/mobile laboratory or by staff sent out by such a laboratory, the operation of which is the responsibility of a permanent laboratory accredited by the Irish National Board. Site calibration that is performed on site by individuals and organisations that do not have a permanent calibration laboratory. Calibration may be performed using (a) (b) (c) (d) portable test equipment a site laboratory a mobile laboratory or equipment from a mobile or site laboratory Standard Specification or Calibration Procedure Used: The standard specification or calibration procedure that is accredited is the issue that is current on the date of the most recent visit, unless otherwise stated. Glossary of Terms Facilities: Public calibration service: Conditionally available for public calibration: Normally not available for public calibration: Commercial operations which actively seek work from others. Established for another primary purpose but, more commonly than not, is available for outside work. Unavailable for public calibration more often than not. Laboratory users wishing to obtain assurance that calibration results are reliable and carried out to the Irish National Board criteria should insist on receiving an accredited calibration certificate. Users should contact the laboratory directly to ensure that this schedule of accreditation is current. INAB will on request verify the status and scope. Edition 12, 03/08/2017 287C Page 3 of 7

Site Calibration using portable (Nominal temperature for calibration work: 5 to 45 C) Range of 775 Emission tester for CO (Carbon monoxide) petrol power motor Range: 0-3.6 Vol % ± 2.1% method MICP 04-02 vehicle.01 Calibration of Petrol CO2 (Carbon Dioxide) emission tester Range: 0-14.2 Vol % ± 1.3% Propane HC (Hydrocarbons) Range: 0-2050 ppm Vol ± 1.2% 775 Emission tester for Light Absorption diesel powered motor Coefficient Units vehicles method MICP 03 Calibration of Diesel 'K' values Emission Tester 0-3.5 m-1 ± 0.07 m-1 * Notes: 1. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 2. CMC s expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 12, 03/08/2017 287C Page 4 of 7

Range of 111 Headlight tester for Inclination by laser beam Ranges: method MICP 01.07 0 on X axis & 0 on Y axis ± 0.25% 0 on X axis & -3.5% on Y ± 0.25% axis +3.5% on X axis & 0 on Y ±0.25% axis * Notes: 1. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 2. CMC s expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 12, 03/08/2017 287C Page 5 of 7

Range of 1150 Roller brake testers for Calibration bar, masses and Circometer method MICP 02 Force 0.5 kn - 1.5 kn ± 0.08 kn 1.5 kn - 2.5 kn ± 0.08 kn 2.5 kn - 3.5 kn ± 0.08 kn 3.5 kn - 4.5 kn ± 0.09 kn 4.5 kn - 5.5 kn ± 0.10 kn 5.5 kn - 6.5 kn ± 0.10 kn 6.5 kn - 7.5 kn ± 0.10 kn 7.5 kn - 8.5 kn ± 0.12 kn 8.5 kn - 10.5 kn ± 0.14 kn 10.5 kn - 12.5 kn ± 0.16 kn Brake tester with maximum break force up to 40.5 kn 0.5 kn - 1.5 kn ± 0.19 kn 1.5 kn - 3.5 kn ± 0.19 kn 3.5 kn - 7.5 kn ± 0.21 kn 7.5 kn - 11.5 kn ± 0.27 kn 11.5 kn - 20.5 kn ± 0.37 kn 20.5 kn - 30.5 kn ± 0.49 kn 30.5 kn - 40.5 kn ± 0.63 kn Edition 12, 03/08/2017 287C Page 6 of 7

Range of 1151 Suspension tester for Static displacement from ± 0.31mm 0 to 30mm across four method MICP 06 verticle points, includes zero. 1149 Suspension tester for Weight of vehicle axle at 400kg, ± 8.5 Kg method MICP 06.49 800kg, ± 13 Kg 1200kg ± 15 Kg 1151 Side slip tester for Horizontal displacement ± 0.22 mm zero to ± 21mm across method MICP 05 five points, includes zero. * Notes: 1. In accordance with INAB policy, uncertainties are calculated for an estimated confidence level of not less than 95%. 2. CMC s expressed as an uncertainty (±) to be reported in compliance with EA-4/02, Expression of the Uncertainty of Measurement in Calibration. Edition 12, 03/08/2017 287C Page 7 of 7