Recent improvement of the LHD Thomson scattering system

Similar documents
Development of a dispersion interferometer for magnetic confinement plasma and its application to atmospheric pressure plasmas

Development of Polarization Interferometer Based on Fourier Transform Spectroscopy for Thomson Scattering Diagnostics

Abstract Submitted for the DPP99 Meeting of The American Physical Society

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

Extension of Wavelength Range in Absolute Intensity Calibration of Space-Resolved EUV Spectrometer for LHD Diagnostics )

Development of a High-Speed VUV Camera System for 2-Dimensional Imaging of Edge Turbulent Structure in the LHD

Progress of experimental study on negative ion production and extraction

Thomson Scattering with laser intra-cavity multipass system to study fast changing structures in fusion plasma

Progress of Confinement Physics Study in Compact Helical System

Unfolding of neutron spectra with an experimentally determined diamond detector response function

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

PoS(ECPD2015)042. Hardened x-ray crystal spectrometer. Speaker. C. Reverdin 1, L. Lecherbourg, V. Dervieux, D. Gontier, B. Loupias. S.

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

Design study of the divertor Thomson scattering system for JT-60SA

The details of point source helicity injection as a noninductive startup technique must be characterized:

GA A23198 HORIZONTAL THOMSON SCATTERING SYSTEMS FOR DIII D AND SSPX

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

PoS(PD07)031. General performance of the IceCube detector and the calibration results

Holographic Interferometry in Investigations of the Currenr Sheet Plasmas

Turbulence Measurements with the Upgraded Phase Contrast Imaging Diagnostic in Alcator C-Mod

GA A22337 INITIAL OPERATION OF THE DIVERTOR THOMSON SCATTERING DIAGNOSTIC ON DIII D

Study of High-energy Ion Tail Formation with Second Harmonic ICRF Heating and NBI in LHD

arxiv: v2 [physics.ins-det] 17 Jun 2014

Retarding field energy analyzers for the ion temperature measurements in the SOL plasmas of the tokamak ISTTOK and the TJ-II stellarator

PoS(PhotoDet 2012)010

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Improved absolute calibration of core Thomson scattering(ts) diagnostics on Alctor C-Mod

INTERFEROMETER SYSTEMS ON LHD

Analyses of Visible Images of the Plasma Periphery Observed with Tangentially Viewing CCD Cameras in the Large Helical Device

Evaluation at the intermediate focus for EUV Light Source

OPTICAL MEASUREMENT OF ASIAN DUST OVER DAEJEON CITY IN 2016 BY DEPOLARIZATION LIDAR IN AD-NETWORK

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Supplementary Figure 1 Comparison of single quantum emitters on two type of substrates:

Precision neutron flux measurement with a neutron beam monitor

Bifurcation-Like Behavior of Electrostatic Potential in LHD )

The Cosmic Ray Air Fluorescence Fresnel lens Telescope (CRAFFT) for the next generation UHECR observatory

High quantum efficiency S-20 photocathodes for photon counting applications

Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter

Development of Target Injection and Tracking for IFE in Japan

PoS(ICRC2015)641. Cloud Monitoring using Nitrogen Laser for LHAASO Experiment. Z.D. Sun 1,Y. Zhang 2,F.R. Zhu 1 for the LHAASO Collaboration

EUV Reflectivity measurements on Acktar Sample Magic Black

Intermittent Behavior of Local Electron Temperature in a Linear ECR Plasma )

Development of a Lithium Beam Probe and Measurement of Density Pedestal in JT-60U

Role of Low-Order Rational Surfaces in Transport Barrier Formation on the Large Helical Device

Calibration of and Measurements from the C-Mod MSE Diagnostic

SUPPLEMENTARY INFORMATION

An Overview of Laser-Driven Magnetized Liner Inertial Fusion on OMEGA

Background optimization for a new spherical gas detector for very light WIMP detection

Supplementary Figures

Ion and Electron Heating Characteristics of Magnetic Reconnection in TS-3 and UTST Merging Startup Experiments

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Laboratory experiments on the formation and recoil jet transport of aerosol by laser ablation

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

The Compton backscattering Polarimeter of the A4 Experiment

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

laser with Q-switching for generation of terahertz radiation Multiline CO 2 Journal of Physics: Conference Series PAPER OPEN ACCESS

Atmospheric Lidar The Atmospheric Lidar (ATLID) is a high-spectral resolution lidar and will be the first of its type to be flown in space.

Lecture 11: Doppler wind lidar

An Overview of Laser-Driven Magnetized Liner Inertial Fusion on OMEGA

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

How to Prepare an Experiment using the Gamma Beam System at ELI-NP

Production of Over-dense Plasmas by Launching. 2.45GHz Electron Cyclotron Waves in a Helical Device

channel system which covers both sides of the laser line. Coverage on both sides of the spectrum allows for

Survey of EUV Impurity Line Spectra and EUV Bremsstrahlung Continuum in LHD )

Development of Polarization Interferometer for Thomson Scattering Diagnostics in JT-60U

requency generation spectroscopy Rahul N

ULTRA-INTENSE LASER PLASMA INTERACTIONS RELATED TO FAST IGNITOR IN INERTIAL CONFINEMENT FUSION

Lecture 8: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Stimulated Emission. Electrons can absorb photons from medium. Accelerated electrons emit light to return their ground state

Development of Laser Measurement to Space Debris at Shanghai SLR Station

Infrared Imaging Video Bolometer with a Double Layer Absorbing Foil

Density Collapse in Improved Confinement Mode on Tohoku University Heliac

Exploring the Atmosphere with Lidars

Progress Report on the A4 Compton Backscattering Polarimeter

ENERGY DEPOSITION EFFECTS OF THE X PHOTON BEAM ON THE MIRROR OF PLASMON-X EXPERIMENT AT LI2FE. Francesco Broggi, Luca Serafini

Simulations of an etched spiral axial attenuation scheme for an on-axis reflecting telescope

Experimental study of nonlinear laser-beam Thomson scattering

Monitoring of Eyjafjallajökull Ash Layer Evolution over Payerne Switzerland with a Raman Lidar

Comparison of Ion Internal Transport Barrier Formation between Hydrogen and Helium Dominated Plasmas )

Ion Heating Experiments Using Perpendicular Neutral Beam Injection in the Large Helical Device

Waseda University. Design of High Brightness Laser-Compton Light Source for EUV Lithography Research in Shorter Wavelength Region

Controlling Graphene Ultrafast Hot Carrier Response from Metal-like. to Semiconductor-like by Electrostatic Gating

Cauchois Johansson x-ray spectrograph for kev energy range

Lecture 4: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

Three Dimensional Measurements Of Geodesic Acoustic Mode with Correlation Doppler Reflectometers

Performance of the ALICE Muon Trigger system in Pb Pb collisions

Raman and elastic lidar techniques for aerosol observation at CIAO

A faster, more accurate way of characterizing cube beamsplitters using the Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

Double Null Merging Start-up Experiments in the University of Tokyo Spherical Tokamak

The MID instrument.

Development of a table top TW laser accelerator for medical imaging isotope production

Pulse Height Analysis System (PHA) designed for W7-X Presented by Monika KUBKOWSKA

Nanosphere Lithography

PHYS 214 Exam Spring 2017 Midterm

Assessment of Threshold for Nonlinear Effects in Ibsen Transmission Gratings

APPLICATION NOTE. Supercontinuum Generation in SCG-800 Photonic Crystal Fiber. Technology and Applications Center Newport Corporation

Measuring Laser Diode Optical Power with an Integrating Sphere

Transcription:

Recent improvement of the LHD Thomson scattering system 1 National Institute for Fusion Science Oroshi 322-6, Toki, Gifu 509-5292, Japan E-mail: yamadai@lhd.nifs.ac.jp H. Funaba, R. Yasuhara, K. Narihara, and H. Hayashi National Institute for Fusion Science Oroshi 322-6, Toki, Gifu 509-5292, Japan The Large Helical Device (LHD) Thomson scattering system has routinely measured electron temperature (T e ) and density (n e ) profiles of LHD plasmas along the LHD major radius since the second LHD experiment campaign, 1998. It is one of the most powerful Thomson scattering systems in the world. During the past 15 years, we have improved the LHD Thomson scattering system for increasing data reliability and accuracy, expanding measurable temperature and density ranges, and searching new physical findings. The number of spatial points, spatial resolution and sampling rate are 144, ~20 mm, and 10-100 Hz (100-10 msec), which depends on the laser repetition frequency, respectively. In the first design, the optimized T e ranges of the system were set to be T e = 50 ev-10 kev = 10 18-10 21 m -3 respectively. Current measurable T e ranges have been expanded as T e = 1 ev-30 kev = 10 18-10 22 m -3. To obtain accurate and reliable T e data from the LHD Thomson scattering system, we tried many recalibrations and tested a few data analysis procedures. In the paper, we describe the current status of the LHD Thomson scattering system. First EPs Conference on Plasma Diagnostics - 1 st ECPD 14-17 April 2015, Villa Mondragone, Frascati (Rome) Italy 1 Speaker Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/

1.Introduction The Thomson scattering system is one of the most reliable diagnostic systems for measuring local electron temperatures and densities of fusion plasmas. We have developed and installed an yttrium-aluminum-garnet (YAG) laser Thomson scattering system on the large helical device (LHD), and have measured the T e profiles of LHD plasmas since the LHD second experiment campaign (1998). [1-3] The LHD Thomson scattering system has following the features: multilaser system using high-repetition YAG lasers, light collection optics based on a large spherical mirror, and multichannel polychromators. The schematic diagram of the LHD Thomson scattering system is shown in Fig.1. [3] The laser beam travels through LHD plasmas along the LHD major radius at a horizontally elongated section. Thomson scattered light is collected with a large spherical mirror, reflected onto optical fibers with a core diameter of 2 mm, and transmitted to 144 polychromators. First we constructed 144 five-wavelength channel polychromators. The optimized T e range of them was set to be 50 ev-10 kev. Now we have three types of polychromators; a low-temperature type (edge region), a standard type (core region), and a high-temperature type (central region). All of them have an additional Rayleigh scattering channel to determine absolute n e. In the following sections, the current status of the LHD Thomson scattering system is described. 2.Laser System In the initial phase, five 0.5J/50 Hz lasers (Continuum 8050) were installed. [4] Currently a 1.6 J/30 Hz laser (Continuum 9030), two 2 J/10 Hz lasers (Thales 230/10), and a 0.5 J/50 Hz Fig.1. Schematic diagram of the LHD Thomson scattering system. 2

laser (Continuum 8050) are available. In each laser system, a beam telescope optics has been installed to adjust beam diameter and divergence. In the initial phase, we developed beam packing mirrors which are similar to that developed by the DIII-D Thomson scattering team to pack several laser beams. [5] Recently, we have installed a new beam merging optics for two lasers to establish a complete coaxial beam transport. [6] The system is based on the polarization control technique. Figure 2 shows the schematics diagram. The both polarizations of laser L1 and L2 are horizontal just after the laser units. The polarizers P1 and P2 are used as polarization purifiers. The polarizations of the two beams after P1 and P2 are almost completely horizontal, better than 100:1. The polarization of the laser L1 is rotated to vertical by a l/2 waveplate so as to go through the polarizer P3. The beam direction and position of the beam #1 are adjusted with the steering mirror M1. On the other hand, the laser beam #2 is reflected by the polarizer P3, and the beam direction of the beam #2 is adjusted with the polarizer P3. Thus, the beam axes of the two laser beams can be in a coaxial configuration. 3.Light collection optics Fig. 2. Schematic diagram of the coaxial beam merging system. We have now two view windows as shown in Fig.3. First, the main view window was installed in the initial phase, and there is no significant change up to now. The main window is made from fused silica and the dimensions are 600 mm x 350 mm x 40 mm. The distance between the LHD plasma center and the center of the main window, solid angle and scattering angle in the backscattering measurements are 3387 mm, 18 msr and 167 respectively. The Thomson scattered light is collected by a large, 1.8 m x 1.5 m, gold-coated mirror onto 144 optical fibers with the core diameter of 2.0 mm. [7] The curvature of the spherical mirror is 4500 mm, and the center of curvature has been Fig.3. Schematic diagram of the two observation windows. 3

set at the window center. In addition to the main window, we installed a small circular window, mirror and fiber to observe different electron temperature component as described later. The second view window is a circular fused silica window. The diameter, solid angle and scattering angle for the backward scattering measurement are 344 mm, 7.6 msr and 171 respectively. Currently the second light collection optics observes T e at a spatial point (plasma center). By using the new window, T e component parallel to the LHD magnetic field line can be obtained around plasma center. The number of measurement points will be increased by adding optical fibers and polychromators. 4. Polychromator Table I. Specification of the light collection optics. ---------------------------------------------------------------------- Main window Second window Dimension [mm] 350 x 600 344 f Scattering angle [deg.] 167 171 Solid angle [msr] 18 7.6 Spatial resolution [mm] 18 10 Number of spatial points 144 1 ---------------------------------------------------------------------- We have operated three types of polychromators: low-temperature type (edge region), standard type (core region), and high-temperature type (central region). A schematic diagram of the polychromator is shown in Fig.4. [3] Thomson scattered photons are separated by the interference filters and detected by avalanche photo diode (APD) detectors. The wavelength channels, CH.1-5 are used for Thomson scattering measurement, and the final CH.6 is used for Rayleigh scattering calibration. Figures 5 a) and b) show examples of the spectral responses of a low-temperature type and standard type polychromators respectively. The solid curves show Thomson scattering spectra at [5, 50 and 500 ev] and [100, 1000 and 5000 ev] estimated by using the Selden's formula. [8] All polychromators are equipped with a Rayleigh scattering channel for absolute density calibration. [9] The standard type polychromators have been optimized for the temperature region of 50 ev <T e < 10 kev. The low-temperature type is designed for observing the low temperature edge region by changing the interference filters, and it can measure T e below 1 ev to 500 ev. The peak transmittance of each filter is about 60-80 %, and the blocking power at 1064 nm is better than 10-4. In our Thomson scattering system, stray light is hardly detected, owing to the high blocking power In addition, the influence of plasma light is negligibly small in typical plasma experiments because high-pass filters (small capacitor) have been inserted between the preamplifier in the polychromator and the external DC amplifier. The cutoff frequency is 300 khz. Therefore, a fast Thomson scattering signal with the pulse duration of ~10 nsec (~100 MHz) can freely pass through the high-pass filter, and the slow plasma light component is almost completely rejected by the high-pass filter. However, the influence of intense plasma light on APDs sometimes appears in high-density experiments, resulting in strange results. We monitor the slow plasma light component too in order to check the data reliability. [10] It is noted that since the characteristics of band-pass filters and APDs strongly depend on the temperature, the temperature of the polychromators is stabilized with 4

temperature-controlled (+0.1 ºC) chilled water and the laboratory temperature is controlled within 1 ºC. In order to obtain absolute electron densities, we have calibrated the total sensitivity of the light collection optics and polychromator by using Rayleigh scattering in gaseous nitrogen. We formerly tried both calibrations using Raman and Rayleigh scatterings. [9] In our case, Rayleigh scattering calibration provides more accurate and reliable calibration data, because the spectral response of our polychromators is not good for the accurate measurement of Raman scattering signals. Spectral Response [arb] 2.5 2.0 1.5 1.0 0.5 Poly #010 / R = 2546 [mm] / SA = 170.3 [deg.] a) 1064 nm 5 [ev] 0.0 1000 1020 1040 1060 1080 1100 Wavelength [nm] Fig. 5. Spectral response of the polychromators of the low-t e region, a), and core region, b), respectively. 5. Scattering configuration Fig. 4. Schematic diagram of the LHD polychromator. 50 [ev] 500 [ev] Poly #080 / R = 3984 [mm] / SA = 165.8 [deg.] b) 100 [ev] 1064 nm 0 600 700 800 900 1000 1100 Wavelength [nm] The original LHD Thomson scattering system has a backward scattering configuration using the main view window. In the original design, laser pulses are absorbed by a beam dump after traveling through plasma. Recently we removed the beam dump and installed a beamreturning mirror and an optical delay path of 30 m. [11] The laser beam is reflected by a mirror and runs through the LHD plasma again as shown in Fig. 6. Forward scattering light is emitted from the returned pulse toward the viewing window. The scattering angle is 13 (= 180 17 ) at the plasma center. The two Thomson scattering signals, backward and forward scatterings, can be separately observed due to the optical delay path. The temporal difference between the backward and forward scattering signals is 100 nsec. By combing the backward and forward scattering measurements, the measurable Spectral Response [arb] 2 1000 [ev] 5000 [ev] 5

temperature range will be expanded as T e = 50 ev-10 kev to T e =1 ev 30 kev. In addition, we have installed a new window as described in Section 2. We now can observe four T e components by using the two view windows and two scattering configurations, backward and forward Thomson scatterings. Detail analysis by comparing the four temperatures is now in progress. [12][13] 6.Summary The LHD Thomson scattering system has routinely measured electron temperature and density profiles of LHD plasmas since 1999. During the past 15 years, we have improved the LHD Thomson scattering system for increasing data reliability and accuracy, expanding measurable temperature and density ranges, and searching new physical findings. From the Thomson scattering measuremnets using the recently installed second view window and beam returning system, new insights of plasma physics will be provided. This work was supported by the NIFS LHD project budgets (NIFS14ULHH005 and NIFS14ULHH801) and JSPS KAKENHI Grant Number 25289341. References [1] K. Narihara et al., Rev. Sci. Instrum., 72, 1122 (2001). [2] K. Narihara et al., Phys. Rev. Lett., 87, 135002 (2002). Fig. 6. Schematic diagram of the beam returning system. [3] Yamada et al., Fusion Sci. Tech., 58, 345 (2010). [4] et al., Rev. Sci. Instrum., 72, 1126 (2001). [5] T. N. Carlstorm et al.., Rev. Sci. Instrum., 63, 4901 (1992). [6] R. Yasuhara et al., Plasma Fusion Res., 7, 2402030 (2012). [7] K. Narihara et al., Rev. Sci. Instrum., 72, 3878 (2004). [8] A. C. Selden, Phys. Lett., 79A, 405 (1980). [9] et al., Plasma Fusion Res., S1106 (2007). [10] K. Narihara et al., Plasma Fusion Res., 2, S1107 (2007). [11] R. Yasuhra et al., Rev. Sci. Instrum. 83, 10E326 (2012). [12] et al., 40 th EPS Conf. Proc. O2.112 (2013). [13] et al., 41 th EPS Conf. Proc. P4.009 (2014). 6