Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Similar documents
The Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance

Guide to Peptide Quantitation. Agilent clinical research

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Agilent ESI and APCI sources: for polar to non-polar compounds

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Agilent Technologies LCMS Portfolio

Translational Biomarker Core

Multi-residue analysis of pesticides by GC-HRMS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

Highly Sensitive and Rugged GC/MS/MS Tool

The new Water Screening PCDL

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Revolutionary Sensitivity, Speed, and Performance

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

QTRAP and SelexION+- Improving the Sensitivity, Speed and Selectivity in Food, Clinical Research and Pharmaceutical Applications

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

TOXICOLOGY & FORENSIC APPLICATIONS

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Overview. Introduction

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Making Sense of Differences in LCMS Data: Integrated Tools

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

MassHunter TOF/QTOF Users Meeting

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

GC/MS Application Note

ABI 3200 Q TRAP LC/MS/MS System

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Agilent Solutions for Traditional Medicine. Ramaswami.R, General Manager-CAG Agilent Technologies India.

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Agilent InfinityLab SFC Solutions EXTEND YOUR APPLICATION REACH WITH MAXIMUM EFFICIENCY

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Targeted protein quantification

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Bruker Daltonics. microtof-q. Cutting Edge Performance with Sub-ppm Confidence. ESI-Qq TOF. think forward

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

OF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote

Automated and accurate component detection using reference mass spectra

Forensic and toxicological drug screening using liquid chromatography-tandem mass spectrometry with MS/MS library based identification

6 x 5 Ways to Ensure Your LC-MS/MS is Healthy

Transcription:

Agilent 49 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

AGILENT 49 TRIPLE QUADRUPOLE LC/MS SYSTEM WORK SMARTER, DO MORE ifunnel new Q1 Optics new Ion Detector IMPROVED SENSITIVITY AND ROBUSTNESS, GREATER PRODUCTIVITY Curved Collison Cell MassHunter Software Agilent MassHunter Workstation software simplifies sample management, MS method optimization, data processing, and data reporting for quantitative analyses. An impressive suite of tools facilitates sample analysis, particularly for pharmaceutical and regulated laboratory environments. These tools include: Optimizer software delivers automated determination of MRM transitions for quantitation and optimized collision energies for each analyte Dynamic MRM (dmrm) ensures the best possible quantitative results for multi-analyte assays compatible with fast UHPLC separation, by specifying cycle times and allowing the software to determine the maximum dwell time for each MRM transition Triggered MRM (tmrm) data-dependent acquisition allows fast analyte quantitation together with compound confirmation at the lowest assay levels With its new 49 Triple Quadrupole LC/MS System, Agilent Technologies has raised the standard for quantitative analysis. Built on the proven performance of Agilent s ifunnel Technology, the 49 extends sensitivity, dynamic range, robustness, precision, and accuracy to new levels. Through these improvements, users experience increased productivity and greater confidence in their results. Agilent s proprietary ifunnel Technology combines high-efficiency ESI ion generation and ion sampling to deliver unprecedented sensitivity. New triple quadrupole design innovations work in concert to optimize performance and improve quantitation at the lowest concentrations. Enhanced Q1 ion optics with optimized prefilter geometry increases ion transmission and reduces contamination. A tapered hexapole collision cell enables effective collection and transmission of fragment ions. An ion detector with new high energy conversion dynode and low noise characteristics promotes more efficient positive and negative ion detection and quantitation across a wide mass range. tmrm Kits Simplify your assay development and minimize the need for tedious manual adjustments with kits that provide pre-tested methods and a tmrm database and library. Each kit features all the information needed for setting up screening methods and quickly adapting them to your needs. Pesticide Screening tmrm Application Kit Pre-tested analytical methods with a tmrm database and library for over pesticides help you quickly establish customized screening methods that meet your needs. Forensic Toxicology Screening tmrm Application Kit Optimize the monitoring and quantitation of forensic toxicology compounds with a tmrm database of over 2, compounds and pre-tested analytical methods. 2 3

ANALYTICAL CONFIDENCE The story of the Agilent 49 isn t simply about its design and performance; it s also about what it allows you to do better, faster, and with greater confidence than ever before. x1 4 1.9 1. 1. 1. 1.3 1.1.9....4.3.1 Analytical Application: Food Safety Complex Multi-Residue Pesticide Analysis at The Highest Sensitivity Quantifying hundreds of low-level pesticides in food is a particularly challenging analytical problem due to the need to detect, confirm, and quantify many different compound classes in diverse matrices, such as black tea. One very effective approach for minimizing matrix effects is the use of sample dilution, which decreases matrix interference and improves method robustness. However, this approach requires the use of a high-sensitivity instrument in order that target analytes 3 4 8 9 1 11 12 13 14 1 1 1 can be detected and quantitated accurately below the Maximum Residue Level (MRL). The figure shows a 2-fold dilution of over 2 pesticides spiked into black tea at 1 µg/kg (MRL level). Most pesticides can be diluted as much as 1-fold and still be confidently detected. Lower Limits of Quantitation (LLOQ) levels with improved precision ensure more pesticides are accurately quantitated and confirmed at the lowest concentrations. Pesticides LLOQ IDL (pg/ml) (pg/ml) Fipronil 1.39 Bentazon 1.3 Tefiubenzuron 2.13 Hexaflumuron 9 Flubendiamide.4 Fluazinam 2.13. 4.8 4. 4.4 4.2 4. 3.8 3. 3.4 3.2 3. 2.8 2. 2.4 2.2 1...4 Analytical Application: Food Safety Confidently Measure Estrogens in Milk Products New and existing threats to the food supply are leading to increasingly stringent regulations aimed at ensuring product safety. The superior combination of sensitivity, precision, and robustness of the 49 LC/MS system allows the determination of a variety of estrogens at less than pg/ml, and enables assays that easily quantify at levels lower than.1 µg/kg. 1 3.1 3.2 3.3 3.4 3. 3. 3. 3.8 3.9 4. 4.1 4.2 4.3 4.4 4. 4. 4. 4.8 4.9..1.2.3.4....8.9..1.2.3.4.. 2 3 4 8.1 µg/kg in milk Milk blank ID Estrogen LLOQ %RSD IDL (pg/ml) (n = ) (pg/ml) 1 Estriol 11.3 2 1- -Estradiol 1 8.4 2. 3 1-ß-Estradiol 1 1 3. 4 Ethynyl estradiol 1 11. 3. Estrone 9. 1. Diethylstilbestrol 1 12.8 Hexestrol 11.1 1. 8 Dienestrol. MRM chromatograms of 2-fold dilution of 2 pesticides spiked into black tea at 1 µg/kg with insert demonstrating the pesticide LLOQs and IDLs. Demonstration of selected pesticide (Fluazinam) calibration curve with. orders of LDR Overlaid MRM chromatograms of estrogens spiked in cow milk at.1 µg/kg. Enhanced Sensitivity and Precision Yields the Lowest Limits of Detection and Quantitation Greater ion sampling and ion transmission efficiency yields better assay performance. Agilent is leading the way with a new measure of sensitivity performance. Instrument Detection Limit (IDL) is a rigorous, statistically based metric that is a practical sensitivity performance indicator for quantitative assays.....4.3.2.1..9.8.. 3.2 3. 3. 3.4 3.8 3.82 3.8 3.9 3.94 3.98 4.2 4. Area %RSD = 1.1 n = 1 injections %Accuracy = 11 LLOQ of Verapamil 4 attogram on-column..4.2..8..4.2. 4.8 4. 4.4 2.8 2.9 3. 3.1 3.2 3.3 3.4 3. 3. Area %RSD = 12.4 n = injections %Accuracy = 8.1 LLOQ of Bentazon 1 femtogram on-column Estriol amount measured Replicates %RSD t(99%) Estriol IDL pg/ml (LLOQ) n = injections 11.3 3.143 pg/ml MDL = t x (%RSD/1) x Amount = 3.143 x (/1) x 2 fg = pg/ml x1 Inj1 Inj3 1 Inj Inj 44.1 41.1. 2.23 4 3.1 3.2 3.3 3.4 3. 3. 3. 3.8 3.9 4 3.1 3.2 3.3 3.4 3. 3. 3. 3.8 3.9 4 3.1 3.2 3.3 3.4 3. 3. 3. 3.8 3.9 4 3.1 3.2 3.3 3.4 3. 3. 3. 3.8 3.9 4 3. 4.9 4. Inj2 Inj4 Inj

ANALYTICAL CONFIDENCE Analytical Application: Environmental Analysis Quantitation Of Hormones in Drinking Water Via Direct Injection The extreme sensitivity of the 49 LC/MS system allows the quantitation of key endocrine disruptor chemicals (EDCs) at the sub ng/l level in drinking water, using direct injection without the need for time-consuming offline SPE. Excellent assay performance is achieved, including peak area precision (%RSD) at LLOQ levels. Analytical Application: Peptide Quantitation Sub-Attomole Level Peptide Quantitation You Can Depend On Developing assays for target peptide quantitation requires high sensitivity together with a wide dynamic range. The examples shown below for the peptide LVNEVTEFAK demonstrate low attomole oncolumn detection using the Agilent Jet Stream source with standard flow chromatography. Sub-attomole on-column detection was achieved with nanoflow chromatography. These results exhibit orders of linear dynamic range with excellent reproducibility and accuracy at all levels down to and including the lower limit of quantitation. x1 4 8. 8....... 4. 4. 3. 3. 2. 1.. Testosterone Androstenedione 1ß-Ethynylestradiol Equilin Estrone Estriol 1-β-Estradiol 1. 1. 1. 1 1.9 11 11.1 1 11.3 1 11. 11. 11. 1 11.9 12 12.1 12.2 12.3 12.412. 12. 12. 12.812.9 13 13.1 EDCs LLOQ %RSD IDL (ng/l) (n = 8) (ng/l) Estriol 1..18 1β-Estradiol <. 13. 2 Testosterone.1 1.3.31 1α-Ethynylestradiol 1. 14.8 Equilin < 3..22 Estrone <.2.43 Androstenedione < 4.3.2 LOD 3 amol on-column LLOQ amol on-column. amol on-column 2.314 2 2.39 29 2.312 4.4. 1 1. 2 2.2 2.4 2. 2.8 3 3.2 3.4 3. 3.8 4 4.2 4.4 Demonstration of selected seven EDCs MRM chromatograms at LLOQ level with excellent precision and accuracy (inserted table summarizes the LLOQ and IDL levels) Outstanding low attomol sensitivity for synthetic peptide LVNEVTEFAK spiked in tryptic digest. LOD is 3 attomol on-column and LLOQ is attomol on-column. x1 4 1.9 1. 1. 1. 1.3 1.1.9....4.3.1 High Sensitivity MRM at the Fastest Analysis Times The analysis of multiple compounds in targeted applications requires the ability to intelligently schedule multiple MRMs while maintaining high sensitivity at short MRM dwell times. Dynamic MRM sets optimal dwell times to allow confident analysis of a large panel of compounds with enough data points across the peak for precise and accurate quantitation. 123 Pesticides, 1ng/mL pmol 1. 9. 1 1. 2 2. 3 3. 4 4.... 8 8. 9 9. 1 1. 1 1 2 2 3 3 4 4 Carbosulfan, 18 data points x1 Responses 3. 2.8 2. 2.4 2.2 1...4. - More Information From Every Experiment Attomole-level sensitivity and wide dynamic range make it feasible to quantitate multiple proteins in a single analysis. LVNEVTEFAK - 11 Levels, 11 Levels Used, 11 Points, 11 Points Used, QCs LVNEVTEFAK, amol pmol on-column Orders of Linear Dynamic Range R 2 =.998 Concentration (amol on-column) Levels %RSD % RT %RSD (n = ) Accuracy (n = 4) amol 14. 19.8. amol 18. 1 amol 9.4 1. 3 amol 9. 8.1 3 fmol 1. 8.2.12 3 fmol 8 3 fmol. 8.4 3 fmol. 8.4 3 pmol 2.1 1.

Learn more http://www.agilent.com/chem/49qqq Buy online www.agilent.com/chem/store Find an Agilent customer center www.agilent.com/chem/contactus USA and Canada 1-8-22-9 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc., 214 Published in the USA, June 1, 214 991-441EN