The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

Similar documents
Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

110 Lowell Rd Hudson, NH USA Tel:

Product Descriptions and Offerings

Hydra-C Application Note: 1076

Basic Digestion Principles

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Mercury Stack Monitor SM-4

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

AULA 254 AULA Fluorescence

Fusion UV/Persulfate TOC Analyzer

Analysis of domestic sludge using the Agilent 4200 MP-AES

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

DMA-80L TECHNICAL SPECIFICATIONS

Fusion UV/Persulfate TOC Analyzer

University Wet Chemistry Analyzer Packages

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Test Method: CPSC-CH-E

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Elemental analysis of river sediment using the Agilent 4200 MP-AES

cobas 6000 analyzer series Flexibility you can build on

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

cobas e 411 analyzer Confidence in every result.

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

cobas 8000 modular analyzer series Intelligent LabPower

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Atomic Absorption Spectrometer ZEEnit P series

Automated Clinical Analyzer

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

S8 TIGER Series 2 for ASTM D 6443

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Advanced technics in the. (TIC/TOC/TNb)

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

OPTIMIZING METALS SAMPLE PREP

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Shorten your Time-to-Result

Ideal and powerful solution

LCTech GmbH Chromatographie

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

cobas c 111 analyzer Big analyzer performance in a small package

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Kjeltec 2300 Analyzer Unit

JAPAN QUALITY. Automated Clinical Analyzer

Perseverance. Experimentation. Knowledge.

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

The Clinical Chemistry System that offers more so you do less!

Your partner in Science!

Total Organic Carbon, Total Nitrogen

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

IV. EQUIPMENT a. Horiba LA 950 main unit b. Dry sample unit that has a silencer behind it c. Cell slide unit that holds

high performance OPTIC 3 and applications a total analytical solution

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Oxygen Demand, Chemical

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Savillex Technical Note Performance of the DST-1000 Acid Purification System

SIFT-MS. technology overview

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

S2 PICOFOX. Innovation with Integrity. Benchtop TXRF Spectrometer TXRF

Determination of Carbon d13c isotopic composition from DIC samples

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

TO-15 Checklist Determination of VOCs in Air by GC-MS

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Automating Wet Chemical Analysis

Transcription:

The Hydra II Family of Mercury Analyzers At Teledyne Leeman Labs, atomic spectroscopy is our business our only business. We are industry leading innovators with a proven track record providing systems that deliver outstanding performance, robustness and operational simplicity. Teledyne Leeman Labs Hydra series mercury analyzers were the first to offer turnkey operation for the Hg analysis techniques: (1) reduction with cold vapor atomic absorption (CVAA) detection, Hydra II AA Atomic Absorption Detection Liquid Samples Provides fully automated analysis for digested samples High sampler capacity (up to 270 sample locations) Large reservoirs for recurring QCs Handles difficult sample matrices Automatic over-range protection (2) reduction with cold vapor atomic fluorescence (CVAF) detection and (3) thermal decomposition with cold vapor atomic absorption detection. The Hydra II family advances the state-of-the-art with improved performance, greater analysis throughput and more simplified operation. Furthermore, the Hydra II family is built around an innovative integrated modular design so systems can be easily reconfigured in the lab to perform other Hg analysis techniques as your analysis requirements change. Hydra II AF Atomic Fluorescence Detection without Pre-concentration Liquid Samples Sub ng/l detection limits Over-range protection Short analysis cycle (~1-2 min.) Very low gas consumption

Hydra II C Atomic Absorption Detection Direct Analysis of Solid and Semi Solids Provides results in about 5 minutes without any sample digestion 70 position autosampler On-the-fly sample programming Easy to maintain Reduction option for low concentration liquids Innovative Integrated Modular design enables one system technique to be reconfigured to another in your lab should your analysis needs change saving money, time and bench space. Hydra II AF Gold Atomic Fluorescence Detection with pre-concentration Liquid Samples For the ultimate in sensitivity Short analysis cycle (~ 3min.) Pre-screen option to minimize contamination Modular detector option for CVAAS methods 3

Sample Digestion Cold Vapor Atomic Absorption (CVAA) The Hydra II AA The Hydra II AA employs the most widely used mercury analysis technique: sample digestion followed by cold vapor atomic absorption (CVAA). This technique s popularity is in its ability to deliver both sensitivity and selectivity needed to meet or exceed the requirements of many US and European standard methods. With its ppt detection capability, exceptional stability and powerful over-range protection system, the most stringent QCs can be satisfied while its high capacity autosampler assures a long period of unattended operation. Fast Results, Better Decisions Sample Uptake Sample Equalibration over-range-check Data Acquisition (User selectable) Rinse The Hydra II AA provides fast analysis cycle times; less than 1 minute. Unlike other systems that consume the full sample, it is able to conduct multiple analyses from the same sample cup in the same amount of time or less. This approach ensures better analysis results and samples can be Fast Replicants from the same sample cup re-analyzed if needed. For example, if intelligent quality control is utilized. Built-in Safety Net Sample Uptake Rinse Systems can become contaminated if a sample with an unexpectedly high concentration of mercury is encountered forcing unanticipated shutdown and cleaning. This is easily avoided with the Hydra II AA s unique over-range protection by which samples with high mercury concentration are automatically detected BEFORE contamination can occur. Analysis is automatically aborted and the system flushed so the next sample can be analyzed correctly. Unplanned downtime is avoided saving time and money. High Mercury Signal Detected Sample Rinse Initiated Analysis Aborted, System Flushed

Analyzing Many Samples is Easy The Hydra II autosampler is designed for the flexibility needed to take advantage of the system s fast analysis speed as well as to accommodate the use of a wide variety of low cost sample cups. It has two large reservoirs for recurring QCs, including CCVs and CCBs, with enough capacity for a complete automated run without operator intervention. A wide variety of commercially available sample cups are supported to achieve maximum productivity and to ensure compatibility with your lab s digestion vessels Difficult Samples Made Simple The novel gas/liquid separator ensures that samples prone to foaming such as municipal wastewater and industrial effluent do not enter the gas phase and contaminate the system. Stability You Can Depend On 0.26 In EPA Method 245.1 a laboratory fortified blank (LFB) with a mercury concentration >10 times the method detection limit must be run every 20 samples. The chart at right shows the LFB consistently passes the ±15% accuracy limits (depicted in red). Concentration (ng/ml) 0.24 0.22 0.2 0.18 0.16 0.14 0 1 2 3 4 5 6 7 8 9 Time (hrs) Mercury Analyzers for a Cleaner Tomorrow 5

Sample Digestion Cold Vapor Atomic Fluorescence The Hydra II AF and AF Gold With the drive to routinely achieve sub ppt detection of mercury, analysts are increasingly turning to cold vapor atomic fluorescence (CVAF) which is inherently a more sensitive technique than CVAA. To meet that challenge, Teledyne Leeman Labs developed the Hydra II AF and Hydra II AF Gold systems. The Hydra II AF uses cold vapor atomic fluorescence detection for the measurement of mercury to 0.1 ppt or lower. The Hydra II AF Gold adds a pre-concentration stage using gold amalgamation prior to detection yielding detection levels down to 0.05 ppt or even lower; for the ultimate in trace level mercury detection. Ultimate Sensitivity via Gold Amalgamation To achieve ultra-trace detection levels the Hydra II AF Gold employs a gold amalgamator that traps all of the free mercury resulting in a 10 or more increase in sensitivity compared to the Hydra II AF. Hassle Free Operation Although the level of mercury is predictable most of the time, occasionally it s not. Because high amounts of mercury can contaminate the system, the Hydra II AF Gold has a special pre-screen function. If enabled, a small aliquot of the sample is taken and the gold amalgamator by-passed. If the measured value is < the threshold value, the sample will be analyzed and the sequence continued. If the measured value is > the threshold value, the sample will not be analyzed and it will be flagged for dilution and re-analysis.

Exceptional Linearity An attractive characteristic of atomic fluorescence is its linear range. The chart to the right shows a linear response for the Hydra II AF that extends to 5 orders of magnitude. The benefit to the analyst is that samples with higher concentrations can be measured without additional dilution. Intensity 0.001 0.01 0.1 1 10 100 Concentration (ppb) Calibration curve showing ultra-low level, linearity for EPA 245.7 Sensitivity for the Most Demanding Methods This chart shows signal enhancement using the Hydra II AF Gold to pre-concentrate 12mL of sample prior to analysis. If more sample is pre-concentrated the enhancement increases. EPA Method 1631 employs pre-concentration while EPA Method 245.7 and EN 17582 do not. Intensity 500000 400000 300000 200000 100000 R = 0.99999 R = 0.99982 with preconcentration without preconcentration 0 0 20 40 60 80 100 120-100000 Concentration (ng/l) Mercury Analyzers for a Cleaner Tomorrow 7

Direct Analysis of Solids and Semi Solids The Hydra II C The Hydra II C is a fully automated analyzer that measures mercury in solid and semi-solid sample matrices directly without any acid digestion (sample preparation). It employs the technique of sample combustion (thermal decomposition), mercury concentration via gold amalgamation and detection by cold vapor atomic absorption. The biggest advantage of the Hydra II C is that no sample preparation is required. And, because no sample prep is required, no hazardous waste is generated that would have to be disposed of safely and with high cost. Principle of Operation A weighed sample is deposited into a sample boat (1) and then introduced into the Hydra II C where oxygen begins to flow over the sample. The decomposition furnace (2) temperature is then increased in two stages; first to dry the sample, then to decompose it. The evolved gases are carried through a heated catalyst (3) to produce free mercury while removing halogens, nitrogen oxides, and sulfur oxides. The remaining combustion products including elemental mercury (Hg 0 ) are swept through a drying tube (4) and a gold amalgamation trap (5) where elemental Hg is trapped and concentrated. After the amalgamation step, the trap is heated to release the mercury into a carrier gas which transports it into an atomic absorption spectrometer (6). Typical Applications Beverages Blood Coal Effluent Fertilizer Feed Fly Ash Foods Hair Minerals Ore Petrochemical Sediment Sludge Soil Urine Wastewater Water

Matrix Independent Calibration A key benefit of the thermal decomposition process is its ability to report accurate results regardless of differences in sample matrix, Figure 1. Figure 2 shows the system accuracy for a diverse variety of sample types all obtained from a single aqueous calibration curve. Alternatively, certified reference materials may be used as standards to calibrate the system. Figure 1 Figure 2 Sediment SAMPLE NO. CERTIFICATE (ppm) MEASURED (ppm) RECOVERY (%) Bovine Liver 1577 0.016 0.0178 111.7 Blood Lypho 1 0.0096 0.0091 94.8 Absorbance Coal Dogfish Dogfish Dorm-2 4.64 4.34 93.5 Oyster 1566 0.057 0.061 107.0 Soil 8406 0.06 0.061 101.7 Coal HC-35150 0.176 0.177 100.6 Oyster Taste Concentration Eliminates Transcription Errors Elegant Yet Simple Design Weigh Sample Automatic Weight Transfer Building sample sequences can take considerable effort. The Hydra II C enables sample weights to be automatically transferred directly into the sample table saving time and eliminating transcription error. At the heart of the system is the catalyst tube which can be easily replaced without tools in as little as a minute. Mercury Analyzers for a Cleaner Tomorrow 9

Software Powerful Yet Easy-to-Use Instrument Control is fully automated and appears on a single screen. The graphical display helps operators to understand how the system functions. System parameters are automatically stored and can be recalled at any time to satisfy audit requirements. On start-up, simply clicking the start button returns all system conditions to the last setting saved with the method. On-the-fly Sample Programming saves valuable time by allowing the operator to start a sample sequence even if individual sample entries are not yet complete. Samples can be easily located, added and positioned using the convenient rack map display. Intelligent Quality Control enables the analyst to define acceptance limits for his quality control checks and choose from a variety of corrective actions when the limits are not met. Each QC sample can be programmed as an initial, recurring, and/or final QC with unique corrective actions. Preventive Maintenance. The software keeps a record of routine maintenance and notifies the analyst when maintenance is required. When a maintenance procedure is required, the Hydra II provides the analyst with step-by-step instructions, including audio/visual support. In this case, the gold trap was highlighted on the preventive maintenance screen and the Maintenance button was clicked to start the detailed instructions. Au Trap

Hydra II Mercury Family At-a-Glance Capabilities Summary Sample Hydra II AA Hydra II AF Hydra II AF Gold Hydra II C Analytical Method Used Chemical reduction followed by cold vapor atomic absorption (CVAA) Chemical reduction followed by cold vapor atomic fluorescence (CVAF) Chemical reduction and Hg pre-concentration followed by cold vapor atomic fluorescence (CVAF) Thermal decomposition followed by amalgamation and atomic absorption Recommended for: Liquid samples Hg measured from low ppt to ppm levels Liquid samples Hg measured from sub ppt to high ppb levels Liquid samples When the lowest detection levels are required Solid, semi-solid matrices Analysis without sample preparation Detection Limit 1 ppt 0.1 ppt 0.05 ppt 0.001 ng Usable Range 1 ppt 1 ppm 0.1 ppt 250 ppb <0.05 ppt 250 ppb 0.001 ng 1500 ng; <25,000 ng with extended range option Key Capabilities Hydra II AA Hydra II AF Hydra II AF Gold Hydra II C High Performance Gas/Liquid separator Y Y Y NA Easy access on the fly sample introduction system Dual cell detection system for wide dynamic range Built in high concentration protection system Flow through rinse to minimize carryover even at ultra-low levels Counter-flow Nafion membrane dryer to minimize vapor formation in detector cells Y Y Y Y Y N N Y Y Y Y NA Y Y Y NA Y Y Y Y Can be reconfigured to liquids analysis NA NA NA Y Can be reconfigured to solids analysis Y N N NA Ultra-trace analysis mode with gold amalgamation for lower detection levels Regulatory and/or Standard Methods System Selection Guide (US) EPA 245.1 (US) EPA 245.5 (US) EPA 245.6 NA N Y Y Hydra II AA Hydra II AF Hydra II AF Gold Hydra II C (US) EPA 245.7 (US) EPA 7470A (US) EPA 7471B (US) EPA 7473 (US) EPA 1631E ASTM D6722-01 EN 1483 EN 13806 EN 13506 EN 12338 EN 17582 Mercury Analyzers for a Cleaner Tomorrow 7 11

When you buy from Teledyne Leeman Labs you get much more than a quality instrument ICP Spectrometers Every order we receive gives us an opportunity to develop a lasting relationship with our customers. Our customers are not numbers to us. We know that your ability to succeed depends on your ability to get the help you need when you need it. And when you reach out to Teledyne Leeman Labs for assistance you ll encounter no complicated phone menus or call center hassles. Rather, you will speak to a very knowledgeable member of our team who is ready and able to answer your question or identify the nature of your problem and then work with you to solve it. We offer all of the after sales support services you need, including: Telephone support Remote diagnostics capabilities Onsite diagnostic and repair services Operator training at our facility or yours DC Arc Spectrometers A range of service maintenance agreements Custom support agreements for special circumstances Readily available consumables/supplies and parts NIST traceable calibration standards Mercury reagents As a leading innovator in atomic spectroscopy, we offer other powerful systems for inorganic, metal analysis including: ICP Standards & Mercury Reagents Inductively Coupled Plasma Optical Emission Spectrometers (ICP-OES) for low to trace level analysis of metals, metallic components in a very wide variety of sample matrices DC Arc Spectrometers for the analysis of inorganic components in solids without sample preparation For more information, please contact Teledyne Leeman Labs. After Sales Support 6 Wentworth Drive Hudson, NH 03051 www.teledyneleemanlabs.com Tel: 603.886.8400 Email: LeemanLabsinfo@teledyne.com MLM010 1/12