This document contains the following supporting information: 1. Wide field scanning electron microscope image

Similar documents
PHOTOLUMINESCENCE SPECTRA AND QUANTUM YIELDS OF GOLD NANOSPHERE MONOMERS AND DIMERS IN AQUEOUS SUSPENSION

1. Transition dipole moment

Understanding Nanoplasmonics. Greg Sun University of Massachusetts Boston

Far-field radiation pattern in Coherent Anti-stokes Raman Scattering (CARS) Microscopy.

Optical cavity modes in gold shell particles

Supplementary Figure 1: Power dependence of hot-electrons reduction of 4-NTP to 4-ATP. a) SERS spectra of the hot-electron reduction reaction using

LAB 3: Confocal Microscope Imaging of single-emitter fluorescence. LAB 4: Hanbury Brown and Twiss setup. Photon antibunching. Roshita Ramkhalawon

Enhancing the Rate of Spontaneous Emission in Active Core-Shell Nanowire Resonators

Collective effects in second-harmonic generation from plasmonic oligomers

Electronic Supplementary Information

Third harmonic upconversion enhancement from a single. semiconductor nanoparticle coupled to a plasmonic antenna

Energy transport in metal nanoparticle plasmon waveguides

Evaluating nanogaps in Ag and Au nanoparticle clusters for SERS applications using COMSOL Multiphysics

Origin of Optical Enhancement by Metal Nanoparticles. Greg Sun University of Massachusetts Boston

Laboratory 3: Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown, and Twiss Setup for Photon Antibunching

Single Emitter Detection with Fluorescence and Extinction Spectroscopy

Biosensing based on slow plasmon nanocavities

Aluminum for nonlinear plasmonics: Methods Section

Γ43 γ. Pump Γ31 Γ32 Γ42 Γ41

Enhancement of Exciton Transport in Porphyrin. Aggregate Nanostructures by Controlling. Hierarchical Self-Assembly

Full-color Subwavelength Printing with Gapplasmonic

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca

Supplementary Materials

λmax = k d Supplementary Figures

Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors

Spatial Coherence Properties of Organic Molecules Coupled to Plasmonic Surface Lattice Resonances in the Weak and Strong Coupling Regimes

Supporting Information The Effect of Temperature and Gold Nanoparticle Interaction on the Lifetime and Luminescence of Upconverting Nanoparticles

single-molecule fluorescence resonance energy transfer

ECE280: Nano-Plasmonics and Its Applications. Week8

File Name: Supplementary Information Description: Supplementary Figures and Supplementary Note. File Name: Peer Review File Description:

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown and Twiss Photon Antibunching Setup

Ultrafast Dynamics and Single Particle Spectroscopy of Au-CdSe Nanorods

SUPPLEMENTARY INFORMATION

Anti-Bunching from a Quantum Dot

Diagnostics of Filamentation in Laser Materials with Fluorescent Methods

Supplementary Figures

Connecting metallic nanoparticles by optical

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Supplementary information for. plasmonic nanorods interacting with J-aggregates.

Two-photon single-beam particle trapping of active micro-spheres

Nanojet and Surface Enhanced Raman Spectroscopy (NASERS) for Highly Reproducible and Controllable Single Molecule Detection

Solution structure and dynamics of biopolymers

SURFACE PLASMONS AND THEIR APPLICATIONS IN ELECTRO-OPTICAL DEVICES

Increasing your confidence Proving that data is single molecule. Chem 184 Lecture David Altman 5/27/08

Backscattering enhancement of light by nanoparticles positioned in localized optical intensity peaks

Laboratory 3&4: Confocal Microscopy Imaging of Single-Emitter Fluorescence and Hanbury Brown and Twiss setup for Photon Antibunching

Fast and Slow Ligand Exchange at the Surface of Colloidal Gold Nanoparticles

Optics and Spectroscopy

CHAPTER 7 SUMMARY OF THE PRESENT WORK AND SUGGESTIONS FOR FUTURE WORK

Plasmonics: elementary excitation of a plasma (gas of free charges) nano-scale optics done with plasmons at metal interfaces

l* = 109 nm Glycerol Clean Water Glycerol l = 108 nm Wavelength (nm)

Lecture 10: Surface Plasmon Excitation. 5 nm

Supporting Information

Temperature ( o C)

Metal-Catalyzed Chemical Reaction of. Single Molecules Directly Probed by. Vibrational Spectroscopy

Supporting Information. Optical Scattering Spectral Thermometry and Refractometry of a Single Gold Nanoparticle under CW laser excitation

Supplementary Information

Survey on Laser Spectroscopic Techniques for Condensed Matter

Study of Surface Plasmon Excitation on Different Structures of Gold and Silver

Administrative details:

Supporting Information

n ( λ ) is observed. Further, the bandgap of the ZnTe semiconductor is

Gold-poly(N-isopropylacrylamide) core-shell colloids with homogeneous density profiles: A small angle scattering study

Supplemental material for Bound electron nonlinearity beyond the ionization threshold

Morphology-dependent resonance induced by two-photon excitation in a micro-sphere trapped by a femtosecond pulsed laser

Supporting Information Optical extinction and scattering cross sections of plasmonic nanoparticle dimers in aqueous suspension

Near-field imaging and spectroscopy of electronic states in single-walled carbon nanotubes

Simple strategy for enhancing terahertz emission from coherent longitudinal optical phonons using undoped GaAs/n-type GaAs epitaxial layer structures

[Electronic Supplementary Information]

Electronic Supplementary Information

Radiative and non-radiative photokinetics alteration. inside a single metallic nanometric aperture

Supplemental Information for

Supplementary Information for. Vibrational Spectroscopy at Electrolyte Electrode Interfaces with Graphene Gratings

Measuring Lysozyme Monomer at 0.1 mg/ml Concentration. Equipment used : Sample Preparation and Measurement :

Supporting Information: Ultrafast Excited State Transport and Decay Dynamics in Cesium Lead Mixed-Halide Perovskites

SUPPLEMENTARY INFORMATION

Solution set for EXAM IN TFY4265/FY8906 Biophysical microtechniques

Lab 3 and 4: Single Photon Source

Localized surface plasmons (Particle plasmons)

Lecture 5. Anisotropy decay/data analysis. Enrico Gratton

Wednesday 3 September Session 3: Metamaterials Theory (16:15 16:45, Huxley LT308)

Confocal Microscope Imaging of Single-Emitter Fluorescence and Photon Antibunching

Supporting Information

Multi-Purpose Nonlinear Optical Microscope. Principle and its Applications to Polar Thin Film Observation

Spring 2009 EE 710: Nanoscience and Engineering

Supporting Information

Supporting Information. Single-Particle Absorption Spectroscopy by. Photothermal Contrast

Size-Dependent Biexciton Quantum Yields and Carrier Dynamics of Quasi-

Supplementary Figure 1. Potential energy, volume, and molecular distribution of the

OPTI 511R, Spring 2018 Problem Set 10 Prof. R.J. Jones Due Thursday, April 19

Supporting Information

Supplementary Figure 1. Schematics of light transmission and reflection from a slab confined between

Surface Plasmon Wave

Applications of field-enhanced near-field optical microscopy

sgsp agsp W=20nm W=50nm Re(n eff (e) } Re{E z Im{E x Supplementary Figure 1: Gap surface plasmon modes in MIM waveguides.

Self-calibrated, line-scan STED-FCS to quantify lipid dynamics in model and cell membranes

Supporting information for Metal-semiconductor. nanoparticle hybrids formed by self-organization: a platform to address exciton-plasmon coupling

NanoLab (Phys4970) Mie Theory & Extinction Spectra [ver 1.1.0]

FLUORESCENCE MICROSCOPY TECHNIQUES PRACTICAL MANUAL FOR

Supplementary Figure 1

Transcription:

Supporting information for Self-assembled nanoparticle dimer antennas for plasmonic-enhanced single-molecule fluorescence detection at micromolar concentrations Deep Punj, Raju Regmi, Alexis Devilez, Robin Plauchu, Satish Babu Moparthi, Brian Stout, Nicolas Bonod, Hervé Rigneault, and Jérôme Wenger CNRS, Aix-Marseille Université, Centrale Marseille, Institut Fresnel, UMR 7249, 1313 Marseille, France Email: jerome.wenger@fresnel.fr This document contains the following supporting information: 1. Wide field scanning electron microscope image 2. Effective refractive index for the surrounding medium 3. Gap size estimates 4. PEG spacer reduces the red-shift of the dimer LSPR resonance 5. Absorption, scattering and extinction cross-sections 6. FCS analysis 7. Correlation traces versus excitation polarization on a nanoparticle dimer 8. Experimental data on trimers of nanoparticles 9. Excitation intensity distribution on a trimer of nanoparticles 1. Fluorescence lifetimes and decay traces on dimer and trimer antennas 11. Simulations of FCS and TCSPC results 12. Luminescence background when no fluorescent dye is present 1

1 Wide field image of the sample 1 µm Figure S1: Scanning electron microscope image of the self-assembled dimer nanoparticle antennas on ITO substrate. Several dimer antennas are readily identified on this zone, as highlighted by red boxes. These relevant antennas are then further analyzed on the fluorescence correlation spectroscopy experiment. 2

2 Effective refractive index for the surrounding medium Scattering cross section x 1-3 (µm 2 ) 5 4 3 2 1 5 55 6 65 7 Wavelength (nm) Experiment n = 1.45 n = 1.5 n = 1.55 n = 1.6 75 Figure S2: Determination of the surrounding medium effective refractive index n eff used in Mie theory computations so as to match the local surface plasmon resonance wavelength of a single 8 nm spherical nanoparticle. The experimental scattering spectra (averaged over an ensemble of nanoparticles) is plotted in gray and vertically shifted. The case n eff = 1.5 provides the best matching to the experimental data. Additionally, this finding is confirmed by the average between the refractive index of the water superstrate (n = 1.33) and the ITO substrate (n = 1.81) at 6 nm. 3

3 Gap size estimates 78 LSPR wavelength (nm) 76 74 72 7 68 66 n= 1.6 n= 1.55 n= 1.5 n= 1.45 2 4 6 8 1 Gap size (nm) 12 14 Figure S3: Determination of the gap size from the longitudinal plasmon resonance (LSPR) wavelength. The graph displays the LSPR wavelength for a dimer of 8 nm nanoparticles as function of the gap size, computed according to Mie theory [1]. Different effective refractive indexes for the surrounding medium are also considered; the case n eff = 1.5 provides the best matching to the experimental observations for the scattering spectrum of a single nanoparticle (Fig. S2) and the dimer (Fig. 1e,f). The dashed horizontal lines indicate the spectral interval of the experimentally observed LSPR values, which correspond to a gap size estimate of 6 ± 2 nm. 4

4 PEG spacer reduces the red-shift of the dimer LSPR resonance 1. Scattering intensity (a.u.).8.6.4.2 Dimer Dimer + PEG Monomer. 55 6 65 7 Wavelength (nm) 75 Figure S4: Normalized dark-field scattering spectra in the presence of a supplementary PEG spacer surrounding the 8 nm nanoparticles (green line). A significant blue-shift is observed as compared to the dimer antenna without PEG (red line). This blue-shift indicates a larger gap size of 13 nm according to the calibration graph in Fig. S3 and the PEG refractive index of 1.46. 5

5 Absorption, scattering and extinction cross-sections a 1 b 1 Cross section x 1-2 (µm 2 ) 8 6 4 2 Monomer 8nm Extinction Scattering Absorption Cross section x 1-2 (µm 2 ) 8 6 4 2 Dimer 8nm gap 6nm Extinction Scattering Absorption 5 6 7 Wavelength (nm) 8 5 6 7 Wavelength (nm) 8 Figure S5: Absorption (blue), scattering (green) and extinction (red) cross-sections computed following Mie theory for a single 8 nm gold nanoparticle (a) and a dimer of 8 nm nanoparticles separated by a 6 nm gap (b) assuming an effective homogeneous refractive index of n eff = 1.5. For both systems, scattering dominates over absorption in the spectral range 63-7nm considered in the experiments. 6

6 FCS analysis molecules brightness molecules brightness Figure S6: Notations used in the FCS analysis. The experiments on nanoparticle antennas covered by a solution of fluorescent molecules correspond to the case of having two species with different numbers of molecules and fluorescence brightness as illustrated on Fig. S6: N molecules are present in the dimer hot spot volume and experience a brightness Q, while N (background) molecules with brightness Q are diffusing away from the hot spot but still in the diffraction-limited confocal volume. The fluorescence intensity correlation function can be written (see pages 75-81 of [2]): G(τ) = F (t).f (t + τ) F (t) 2 = 1 + N Q 2 G d (τ) + N Q 2 G d(τ) (N Q + N Q ) 2 (1) where G d (τ) and G d (τ) are the normalized functional forms of the correlation function for each species taken individually based on a three dimensional Brownian diffusion model: ( ) 1 + n T,i exp τ τ bt,i G di (τ) = (2) (1 + τ/τ d,i ) 1 + s 2 i τ/τ d,i n T,i stands for the amplitude of the dark state population, τ bt,i the dark state blinking time, τ d,i the mean residence time (set by translational diffusion) and s i the ratio of transversal to axial dimensions of the analysis volume. The shape parameter is fixed to s =.2 to allow for direct comparison between diffusion times. This parameter was found to have a negligible influence on the estimates for N and Q which are the main goals of the paper. Equation (1) indicates that the different fluorescent species contribute to the amplitude of G(τ) in proportion to the square of their relative fluorescence brightness. This is an important element as it enables extracting a significant FCS signal from a low number of molecules N under conditions of large background N, Q. A purely linear technique -such as time correlated single photon counting 7

TCSPC- experience more difficulties in extracting the useful information from the hotspot (see Section 1 and 11 for details). Here we are primarily interested in quantifying the hotspot fluorescence brightness Q and the hotspot detection volume for FCS, which (for a known sample concentration) amounts to the number of molecules in the hotspot N. This quantification does not require the complete temporal information from the FCS correlation, the value of the correlation function at zero lag time will be sufficient: G() = 1 + N Q 2 + N Q 2 (1 + n T ) (N Q + N Q ) 2 (3) Here we already made the simplification that the amplitude n T of the dark state population is negligible for molecules away from the hot spot, as confirmed by confocal measurements and as expected for a dye with very short lifetime (with 2mM of methyl viologen the fluorescence lifetime of Alexa Fluor 647 is reduced to 3 ps) and under low excitation power (1 µw in continuous). For completeness, we keep considering a free parameter n T for the dark state blinking amplitude in the case of the hotspot. As we will show below, this parameter reduces the fluorescence enhancement and volume reduction factors by (1 + n T ), so the experimental values indicated in the document should be considered as conservative estimates. In addition to the expression of G(), we use the known value of the average total fluorescence intensity F : F = N Q + N Q (4) Inserting the result that N Q = F N Q into Eq. (3), we obtain the expression G() = 1 + N Q 2 + (F N Q )Q (1 + n T ) F 2 (5) which only linearly depends on Q. Inverting this equation provides the fluorescence brightness and number of molecules in the hotspot: and N = F N Q Q = Q = F 2 (G() 1) N Q 2 (F N Q ) (1 + n T ) (6) (F N Q ) 2 F 2 (G() 1) N Q 2 (1 + n T ) (7) These expressions show that in addition to the experimentally measured parameters F, G(), n T, we also need to estimate the values of N, Q to quantify N, Q. The fluorescence brightness away from the hot spot Q is set according to the value found for the confocal reference Q conf. More elaborate strategies can be used (as found in [3]) and lead to comparable results. To estimate the number of molecules N in the background, we take advantage of the polarization response of dimer antennas, and consider the case of excitation polarization perpendicular to the dimer axis. In the case of perpendicular excitation we assume that two single 8 nm gold nanoparticles are excited collectively. According to the formulation of FCS under several laser spots [4], we can write N = 2 N np and 8

Q = Q np where Nnp and Q np are the number of molecules and brightness in the case of a single nanoparticle, which were calibrated independently in our previous work [5, 6] and confirmed by the experiments in Fig. 2. For individual 8 nm gold nanoparticles, we found a fluorescence enhancement η F,np = 6 and a volume reduction R V,np = 18. Hence in the case of a dimer antenna for perpendicular polarization: N = 2 N conf R V,np (8) Q = η F,np Q conf (9) where N conf and Q conf are the number of molecules and brightness in the case of confocal reference. From here we can find out the background molecules N using the relation F = N Q +N Q which provides the information needed to complete the quantification in Eq.(6,7). Lastly for trimers, we use the same procedure as in [5]: the number of emitters and brightness N, Q for the molecules diffusing away from the hot spot are fixed according to the values found at the glass-water interface without nanoparticle, corrected by a factor of C = 1 3(d/2w) 2 to account for the screening induced by the nanoparticles (d is the nanoparticle diameter, w=28 nm is the laser beam waist at focus). Typically, C amounts to.94 for 8 nm nanoparticles. Confocal Dimer Trimer Excitation Linear Parallel Perpendicular 9 +45-45 F (khz) 767 437 428 41 399 4 46 G() 1 2.5e-4.48.7.35.23.31.21 N 4.55 4.4 1.2 1.3 1.1 1.6 τ d (µs) 64 1.9 3.6 1.9 1.7 1.6 1.7 n T -.4 -.2.15.3.1 τ bt (µs) -.4 -.2.5.2.5 Q (khz).19 19 11.4 64 49 58 44 Fluorescence Enhancement 575 6 335 26 35 23 Volume Reduction 73 9 344 35 355 245 Table S1: Fitting parameter results for the FCS curves obtained on dimer (Fig 2c) and trimer nanoantenna (Fig S8d). The experimental conditions are identical between cases: Alexa Fluor 647 concentration 13.3 µm with 2 mm of methyl viologen used as a chemical quencher, excitation power 1 µw with linear polarization. In the dimer case, there is no additional PEG layer, while for the trimer the PEG layer is present so as to maximize the enhancement factor (Fig 4a,c). 9

7 Correlation traces versus excitation polarization on a nanoparticle dimer Correlation G - 1.3.2.1 2 4 6 9 12 14 16. 1-4 1-2 1 1 2 Lag time (ms) Figure S7: Fluorescence correlation functions (raw data) corresponding to the results plotted on Fig. 2d-f of the main document obtained for various angles θ of the laser polarization. 1

8 Experimental data on trimers of nanoparticles a b 15 Intensity (a. u.) 1 5 x1-3 15 1 5 9 +45 5 75-45 5 nm c 5 d.4 55 6 65 7 Wavelength (nm) 75 8 Counts (khz) 45 4 35 Correlation G - 1.3.2.1 2 4 6 Time (s) 8 1. 1-4 1-2 1 1 2 Lag time (ms) Figure S8: (a) Scanning electron image of self-assembled nanoparticle trimers. (b) Dark-field scattering spectra, normalized by the reference spectrum of the lamp, for different illumination polarizations. Due to the triangular shape of the trimer, only minor variations are seen with the polarization direction. No PEG was used in the experiment leading to these data. (c) Fluorescence intensity time trace and (d) FCS correlation function taken on a representative trimer antenna for different polarization orientations (same color code as in (b)). Again, minor variations with the polarization orientation are seen. The experimental conditions are identical to the ones in Fig. 2, with a concentration of Alexa Fluor 647 of 15 µm and 2 mm of methyl viologen, so that the correlation traces can directly be compared between the cases (confocal, dimer and trimer). Remarkably, the correlation amplitude for the trimer is higher than the confocal, indicating sub-wavelength confinement of light, and smaller that the dimer antenna, indicating a larger volume for the trimer as compared to the dimer. 11

9 Excitation intensity distribution on a trimer of nanoparticles a Gap 6 nm b Gap 13 nm Figure S9: Finite-difference time-domain computation of the excitation intensity enhancement (log scale) for the trimer antenna in the equatorial planes of the nanoparticles for two different polarizations as indicated on the graphics. The wavelength is 633 nm, the particle size 8 nm and the gap is 6 nm for (a) and 13 nm for (b). 12

1 Fluorescence lifetimes and decay traces on dimer and trimer antennas a b Intensity (normalized) IRF Dimer Dimer -45 Dimer +45 Dimer 9 Confocal Intensity (normalized) IRF Trimer Trimer -45 Trimer +45 Trimer 9 Confocal 1 2 Time (ns) 3 1 2 Time (ns) 3 Figure S1: Normalized fluorescence decay traces under pulsed excitation for a dimer (a) and a trimer (b) antenna with different excitation polarizations. The black curve indicates the reference decay trace in confocal configuration when no antenna is present. It corresponds to a fluorescence lifetime of 3 ps in the presence of 2 mm of methylviologen (the IRF full width at half maximum is 12 ps). There might be a lifetime reduction due to the nanoantenna. However, due to the large fluorescence contribution from the N molecules surrounding the antenna and the short lifetime of the dye, the effect is blurred and the determination of the lifetime reduction in the hot spot is impossible in this case. These findings stand in good agreement with the simulations shown in Fig. S11. 13

11 Simulations of FCS and TCSPC results a FCS: quadratic with Q* b TCSPC: linear with Q* Correlation G - 1.5.4.3.2.1 Dimer parallel Dimer perpendicular Intensity (normalized) Confocal Dimer parallel Dimer perpendicular. Confocal 1-4 1-2 1 1 2 Lag time (ms) 1 2 Time (ns) 3 Figure S11: Simulated FCS and TCSPC data using only the parameters in Tab. S1. The simulated FCS data (a) should be compared to the experimental results Fig. 2c, and the TCSPC simulations (b) correspond to the case of Fig. S1a. The excellent agreement between simulations and experimental data provides an a posteriori validation of our results (enhancement factor and volume reduction). It also emphasizes the difficulty to extract the useful information from the antenna hotspot hidden in the TCSPC decay curve: while in FCS the hotspot contribution is quadratic with the brightness Q (Eq. 1), in TCSPC the dependence is linear. 14

12 Luminescence background when no fluorescent dye is present Dimer antenna background (no fluorescent dye) a Counts (khz) 4 2 b Correlation G-1.5. 1 2 3 Time (s) 4 5 -.5 1-4 1-2 1 1 2 Lag time (ms) Figure S12: (a) Intensity trace and (b) correlation function on a dimer antenna covered with 2 mm methyl viologen in water solution. No fluorescent molecule is used in this experiment to record the level of luminescence background. White light extinction and laser scattering ensure the presence of a dimer antenna. The laser polarization is oriented along the dimer axis so as to maximize the detected luminescence level. A weak signal is detected on the avalanche photodiodes (a), and originates mainly from residual backscattered laser light after the filters and autoluminescence from the sample. Despite some peaks can be seen sometimes on the time trace, no correlation is found (b), as the FCS data is remarkably symmetric around the zero level. The total integration time for this trace is 2 s, with the same conditions as Fig. 2, S7 and S8. 15

References [1] Stout, B.; Auger, J. C.; Devilez, A. Recursive T-Matrix Algorithm for Resonant Multiple Scattering: Applications to Localized Plasmon Excitation. J. Opt. Soc. Am. A 28, 25, 2549 2557. [2] Zander, C., Enderlein J. & Keller, R. A. Single-Molecule Detection in Solution - Methods and Applications, VCH-Wiley, Berlin/New York, 22. [3] Punj D., Optical antennas for single molecule fluorescence detection at physiological concentration, PhD thesis Aix Marseille University, 214. https://tel.archives-ouvertes.fr/tel-111933 [4] Ghenuche, P.; de Torres, J.; Ferrand, P.; Wenger, J. Multi-focus parallel detection of fluorescent molecules at picomolar concentration with photonic nanojets arrays. Appl. Phys. Lett. 214, 15, 13112. [5] Punj, D.; de Torres, J.; Rigneault, H.; Wenger, J. Gold nanoparticles for enhanced single molecule fluorescence analysis at micromolar concentration. Opt. Express 213, 21, 27338-27343. [6] Wenger, J.; Punj, D.; Rigneault, H. Single gold nanoparticles to enhance the detection of single fluorescent molecules at micromolar concentration using fluorescence correlation spectroscopy. SPIE Photonics Europe 214, 91261N. 16