Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Similar documents
A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Electron Transfer Dissociation of N-linked Glycopeptides from a Recombinant mab Using SYNAPT G2-S HDMS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

Routine MS Detection for USP Chromatographic Methods

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

UPLC Intact MASS Analysis Application Kit

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

[ instrument specifications ]

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

MALDI-HDMS E : A Novel Data Independent Acquisition Method for the Enhanced Analysis of 2D-Gel Tryptic Peptide Digests

Peptide Isolation Using the Prep 150 LC System

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION

Conformational Characterization of Calmodulin by Hydrogen Deuterium Exchange Mass Spectrometry

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Implementation of Methods Translation between Liquid Chromatography Instrumentation

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

IN QUALITATIVE ANALYSIS,

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

PosterREPRINT AN INTERACTIVE PHYSICOCHEMICAL PROPERTY PROFILING SOFTWARE FOR EARLY CANDIDATE ANALYSIS IN DRUG DISCOVERY INTRODUCTION

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Optimization of the sample preparation and extraction methodology

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

Choosing the metabolomics platform

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

LC-HRMS: Challenges for Routine Implementation

ASAP APPLICATION NOTEBOOK: Atmospheric Solids Analysis Probe FINE AND SPECIALTY CHEMICALS ENERGY SYNTHETIC POLYMERS FOOD TESTING

Determination of Pharmaceuticals in Environmental Samples

WADA Technical Document TD2003IDCR

Finnigan LCQ Advantage MAX

TANDEM MASS SPECTROSCOPY

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Integrated approach to HPLC method development: Using all the tools in the chromatographer s toolbox

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

LC-MS Based Metabolomics

Application Note. Edgar Naegele. Abstract

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Translational Biomarker Core

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

Basic Principles for Purification Using Supercritical Fluid Chromatography

[ a ppl ic at ion no t e ]

ADVANCED MULTI-RESIDUE SCREENING IN VETERINARY DRUG ANALYSIS USING UPLC -ToF MS

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Analysis of Polar Metabolites using Mass Spectrometry

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

4.1 MATERIALS 4.2 EQUIPMENTS

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Introduction to the Q Trap LC/MS/MS System

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

Techniques for Structure Elucidation of Unknowns: Finding Substitute Active Pharmaceutical Ingredients in Counterfeit Medicines

Agilent G3212 GC-APCI Source

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Transcription:

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate Michael D. Jones, Xiang Jin Song, Robert S. Plumb, Peter J. Lee, and Andrew Aubin Waters Corporation, Milford, MA, USA INTRODUCTION Impurity profiling is a critical part of the drug development process. Structural elucidation of unknown substances such as synthetic impurities is a key factor to refining pharmaceutical drug potency and safety attributes. 1 Success in solving these very complicated and challenging structural puzzles has been facilitated by evolutions in LC and MS instrumentation; however it still requires a high level of experience to solve these analytical problems. Typically MS/MS data from a triple quadrupole mass spectrometer is interrogated for structural elucidation in impurity profiling, in order to provide fragmentation spectra. However, using MS/MS analysis alone particularly nominal mass spectra may not provide sufficient specificity to determine the analyte structure. Complementing MS/MS with time-of-flight (Tof) data acquisition provides elemental composition information. For small molecules, this significantly improves the elucidation process since it significantly reduces the number of possible elemental compositions. Quetiapine (Figure 1) is an atypical antipsychotic that has been shown to form more than 20 impurities/degradation products. 2 In this application note, we demonstrate the application of high-resolution mass spectrometry to generate exact mass MS/MS fragment analysis data in conjunction with the use of software to automatically identify product ion fragments. This software applies a series of novel, chemically-intelligent algorithms to elucidate an unknown impurity peak of quetiapine that was previously isolated by mass-directed autopurification. 3 Figure 1. Structure of quetiapine, [M+H] = 384.1746. 1

E X P E R IM E N TA L LC conditions LC system: ACQUITY UPLC Column: ACQUITY UPLC BEH C 18 Column, 2.1 x 50 mm, 1.7 µm Column temp.: 65 C Flow rate: 800 µl/min Mobile phase A: 20 mm ammonium bicarbonate, ph 9.0 Mobile phase B: Acetonitrile Gradient: 5 to 95% B for 3.0 min MS conditions MS system: Waters SYNAPT MS System Ionization mode: ESI positive Capillary voltage: 1.5 kv Cone voltage: 15 V Desolvation temp.: 350 C Desolvation gas: 650 L/Hr Source temp: 120 C Acquisition ranges: 100 to 1000 m/z for MS 50 to 600 m/z for MS/MS Collision energies: Ramp from 15 to 30 Lock mass: 300 pg/µl leucine/enkephalin flow at 50 µl/min Data management MassLynx 4.1 Software with MassFragment RESULTS In a previous application note, forced degradation was employed to maximize the amount of an impurity formed during hydrolytic conditions to generate a sufficient mass of impurity for subsequent NMR analysis. 2 The peak giving rise to the m/z 402 ion was isolated using preparative chromatography and mass-directed fraction collection. Although the desired substance was collected, the compound s structure remained unknown. Importance of mass accuracy for determination of elemental composition Instrumentation capable of producing high mass accuracy information is an essential tool in the area of impurity determination. Modern Q-Tof technology makes the acquisition of sub-5-ppm mass accuracy data readily achievable. This, coupled with fast data acquisition speeds that allow the detection of the narrows peaks produced by UPLC chromatography, make it an ideal tool for impurity identification. The sample was analyzed on the SYNAPT MS System to obtain accurate mass MS data and hence elemental composition determination. The impurity had an observed accurate mass of m/z 402.1838. This is an addition of 18.0092 amu to that of quetiapine (m/z 384.1746). The high mass accuracy of the SYNAPT MS System produced a short list of possible elemental compositions. The potential elemental composition list was further reduced by a series of filters. These filters included the ability to limit molecular formulas based on: Elemental symbols and limits (e.g., Nitrogen, 0 to 5) Mass accuracy tolerance (ppm or mda) i-fit isotopic pattern Electron state (odd, even, or both) 2

The Elemental Composition browser returned three possible molecular formulas (Figure 2). The Elemental Composition calculator was set to order the list of proposed elemental compositions according to the fit of the experimental data to the theoretical isotope distribution using i-fit. The i-fit criterion calculated a molecular formula of C 21 H 28 N 3 O 3 S as the best fit. The double bond equivalency (DBE) reported a value of 9.5 and a mass error of -1.3 mda. Possible structures that fit the elemental compositions based on the mass accuracy data for 402.1838 include: Oxidation of the sulfur on quetiapine structure in conjunction with reduction of the C=N double bond in the seven member ring (Figure 3a) Cleavage of the C=N bond producing a nitroso-based structure (Figure 3b) Figure 2. Elemental composition for impurity m/z 402.1838. The double bond equivalence (DBE) value, low i-fit value, and low mda results support the first hit formula. Cleavage of the C=N bond producing a ketone- and amine-based structure (Figure 3c) S-oxide and C=N reduction-based structure? C 21 H 28 N 3 O 3 S C=N cleavage creating a nitroso-based structure? C 21 H 28 N 3 O 3 S C=N cleavage creating an amino/ketone-based structure? C 21 H 28 N 3 O 3 S Figure 3. Structures that fit the m/z 402.1838 mass accuracy results reported in the elemental composition. 3

Examining the forced degradation reaction that enriched the production of the impurity suggests the most probable structure is as shown in Figure 4. Other chemical structures could be proposed based on the accurate mass information of the base m/z alone. Knowing the reaction that produced the addition of 18 amu aids the elucidation decision process. Accurate mass MS/MS analysis A careful examination of the fragmentation patterns obtained during related impurity analysis allows the impurities structural information to be associated with that of the active pharmaceutical ingredient (API). The key to informative MS/MS data is the quality of the fragmentation spectra. The quality of MS/MS spectra assessed in small-molecule analysis is based on the number of fragments and spatial location of the fragments, thus providing added structural informative value for elucidation determination. The SYNAPT MS Systems performs both MS E and traditional MS/MS experiments. MS E experiments allow for simultaneous high and low collision energy data to be collected with one injection. Traditional MS/MS experiments provide additional information in the form of product ion scans, precursor ion scans, and common neutral loss scans. An accurate mass MS/MS product ion scan of 402.1838 was performed to evaluate the fragmentation pattern of the isolated impurity to further support the proposed structure shown in Figure 3c (Figure 5). The fragments produced are most likely associated to cleavage of the seven-member ring that differentiates the three unknown impurities proposed structures. Figure 4. Proposed hydrolysis reaction of quetiapine. Figure 5. Fragment analysis following the hypothesis of the amino/ketone-based structure as the unknown impurity highlighted with MassFragment results. The key structural fragments that added greater confidence in differentiating amine/ketone-based structures to that of the alternatively-proposed structures were the m/z 137.0063, m/z 199.0454, m/z 228.0464, m/z 253.0803, and m/z 309.1260 ions. 4

MassFragment for structural elucidation Structural elucidation requires an expert knowledge of chemistry and bond reactions. MassFragment is a software solution that is capable of automatically identifying product ion fragments using a series of chemically-intelligent algorithms. This approach is based on systematic bond disconnection of the precursor structure instead of the traditional rule-based approach. MassFragment was used to help visualize the correlation of the product ion data with possible structural assignments for the observed fragment ions (Figure 6). MassFragment increases our confidence in the MS/MS fragment analysis of the proposed structure in Figure 3c. The proposed structures were drawn and saved as *.mol files. Each *.mol file was loaded separately into MassFragment to be structurally correlated with the spectra in Figure 5. The MassFragment results ruled out the proposed nitroso-based and S-oxide based structures. The fragment ion m/z 137.0063 was observed in the MS/MS spectra in Figure 5. The MassFragment reports for the S-oxide based structure and the amino/ketone-based structure observed the ion fragment m/z 137.0063 and displayed possible structures. MassFragment was not able to report a structure for this particular fragment ion when the nitroso-based precursor structure was loaded into MassFragment (Table 1). The fragment ion m/z 199.0454 was also observed in the MS/MS spectra. MassFragment reported a candidate structure for fragment ion m/z 199.0454 based on the amino/ketone-based structure (Figure 6). There were no reported structures for this fragment ion when the S-oxide based structure was loaded into MassFragment (Table 2). Figure 6. MassFragment results for the structure proposed in Figure 3c (amino/ketone-based). Table 1. MassFragment results for m/z 137.0055 based on spectra from Figure 6 and nitro-based *.mol file. NMR supporting data The collected fraction was dried down and prepared in deuterated methanol for analysis by NMR. It was determined from the NMR data (not shown) that the impurity m/z 402 was consistent with the proposed structure. Table 2. MassFragment results for m/z 199.0454 based on spectra from Figure 6 and nitro-based *.mol file. 5

CONCLUSIONS For small molecule analysis, the advances in MS technologies with greater mass accuracy readily complement the advances in LC technology and sub-2-µm column particles capable of peak widths of 1 to 3 seconds. Laboratories performing impurity analysis can realize significant benefits by using chemically-intelligent software that improves how this LC/MS E data is analyzed. Analytical benefits The high resolution possible with the SYNAPT MS System provided excellent mass accuracy for elemental composition determination of precursor and product ions. References 1. Ahuja S and Alsante K. Handbook of Isolation and Characterization of Impurities in Pharmaceutical Compounds. 2003; Elsevier. 2. Jones MD et al. Method Development of an Impurity Profile for Quetiapine Fumarate Drug Substance. Waters. 2009; 720003080en. 3. Jones MD et al. Impurity Isolation and Scale-up from UPLC Methodology: Analysis of an Unknown Degradant Found in Quetiapine Fumarate. Waters. 2009; 720003078en. MassFragment facilitated the confirmation of a proposed structure for an unknown impurity isolated from quetiapine in a forced degradation experiment. Realized benefits Increasing confidence in the structural determination due to the high mass accuracy data. Minimizing the number of possible elements in the elemental compositions for the compound(s) and fragments. Using criteria filters such as isotopic pattern values, elemental filters, and mass accuracy values saves time during data evaluation. Correlating spectral MS information to possible structural fragmentation and assigning a rank allows for more confidence in elucidation decisions. Proper characterization of a compound provides greater insight to the reactive behavior of the compound that will lead to more informative formulation and packaging decisions. Waters, ACQUITY UPLC, MassLynx, SYNAPT, The Science of What s Possible, and UPLC are registered trademarks of Waters Corporation. MassFragment and i-fit are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2009 Waters Corporation. Produced in the U.S.A. June 2015 720003079EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com