Condition Monitoring for Maintenance Support

Similar documents
Advanced Methods for Fault Detection

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

SITRON: Site risk assessment approach developed for Nordic countries Ola Bäckström

Independent Component Analysis for Redundant Sensor Validation

CHAPTER 3a. INTRODUCTION TO NUMERICAL METHODS

2. A Basic Statistical Toolbox

Artificial Neural Networks Francesco DI MAIO, Ph.D., Politecnico di Milano Department of Energy - Nuclear Division IEEE - Italian Reliability Chapter

Journal of NUCLEAR SCIENCE and TECHNOLOGY, Vol. 41, No. 7, p (July 2004)

The Research of Heat Transfer Area for 55/19 Steam Generator

Chapter 9 Regression. 9.1 Simple linear regression Linear models Least squares Predictions and residuals.

Review of Errors of Containment Integrated Leak Rate Test for Nuclear Power Plants

ATTACHMENT Mitigating Systems

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Using Principal Component Analysis Modeling to Monitor Temperature Sensors in a Nuclear Research Reactor

INTRODUCTION: Shell and tube heat exchangers are one of the most common equipment found in all plants. How it works?

Expression arrays, normalization, and error models

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

: HEAT TRANSFER & EVAPORATION COURSE CODE : 4072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 70 CREDIT : 5 TIME SCHEDULE

ME 331 Homework Assignment #6

Sensitivity Analysis of a Nuclear Reactor System Finite Element Model

that relative errors are dimensionless. When reporting relative errors it is usual to multiply the fractional error by 100 and report it as a percenta

Axial profiles of heat transfer coefficients in a liquid film evaporator

Synergy between Data Reconciliation and Principal Component Analysis.

A TEST OF THE PRECIPITATION AMOUNT AND INTENSITY MEASUREMENTS WITH THE OTT PLUVIO

How to Plan Experiments

Chapter 8: Flow in Pipes

ABSTRACT I. INTRODUCTION

18.303: Introduction to Green s functions and operator inverses

Correlation between temperatures of air, heat carrier liquid and seabed sediment in renewable low energy network

Stratification issues in the primary system. Review of available validation experiments and State-of-the-Art in modelling capabilities.

12 Moderator And Moderator System

CE 321 INTRODUCTION TO FLUID MECHANICS Fall 2009

Engineering Thermodynamics. Chapter 1. Introductory Concepts and Definition

374 Exergy Analysis. sys (u u 0 ) + P 0 (v v 0 ) T 0 (s s 0 ) where. e sys = u + ν 2 /2 + gz.

ME EN 363 Elementary Instrumentation

INDUSTRIAL RESOURCES, INC. Power Plant Fundamentals Training

Installation effects on an ultrasonic flow meter with implications for self diagnostics

NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE TEMPERATURE DISTRIBUTION INSIDE OIL-COOLED TRANSFORMER WINDINGS

The Quantum Theory of Atoms and Molecules

Available online at ScienceDirect. Procedia Engineering 119 (2015 ) 13 18

Cover Page. The handle holds various files of this Leiden University dissertation

Fig.8-1 Scheme of the fluidization column

QUALIFICATION SPECIFICATION

6. Vector Random Variables

Numerical modelling of direct contact condensation of steam in BWR pressure suppression pool system

Process-Quality Monitoring Using Semi-supervised Probability Latent Variable Regression Models

3D Simulation of the Plunger Cooling during the Hollow Glass Forming Process Model, Validation and Results

Name: 10/21/2014. NE 161 Midterm. Multiple choice 1 to 10 are 2 pts each; then long problems 1 through 4 are 20 points each.

Chapter 8: Flow in Pipes

WATER DISTRIBUTION NETWORKS

The Uncertainty of a Waterdraw Calibration vs. Gravimetric Calibration on Small Volume Provers

The document was not produced by the CAISO and therefore does not necessarily reflect its views or opinion.

CHM Solids, Liquids, and Phase Changes (r15) Charles Taylor 1/9

SOME ASPECTS OF COOLANT CHEMISTRY SAFETY REGULATIONS AT RUSSIA S NPP WITH FAST REACTORS

Basic Analysis of Data

Procedure To Be Adopted When Working on High Voltage Mechanically Switched Capacitors with Damping Network (MSCDN)

Experiment for Justification the Reliability of Passive Safety System in NPP

Chapter 27 Summary Inferences for Regression

The Dynamical Loading of the WWER440/V213 Reactor Pressure Vessel Internals during LOCA Accident in Hot and Cold Leg of the Primary Circuit

INVERSE PROBLEM AND CALIBRATION OF PARAMETERS

DEVELOPMENT AND APPLICATION OF AN APPROACH TO ASSESS THE GLOBAL THERMAL EFFICIENCY OF A THERMAL ELECTRIC POWER PLANT

Availability analysis of nuclear power plant system with the consideration of logical loop structures

Applied Fluid Mechanics

Acoustic Resonance in Main Steam Line Side Branches

Study on Effective Particle Diameters and Coolability of Particulate Beds Packed with Irregular Multi-size Particles

Application of the Stress-Strength Interference Model to the Design of a Thermal- Hydraulic Passive System for Advanced Reactors

Applied Fluid Mechanics

System Identification for Process Control: Recent Experiences and a Personal Outlook

Thermodynamics. Thermodynamics 1

Statistical Modeling and Analysis of Scientific Inquiry: The Basics of Hypothesis Testing

Unit Workbook 2 - Level 5 ENG U64 Thermofluids 2018 UniCourse Ltd. All Rights Reserved. Sample

Integral-based Algorithm for Parameter Identification of the Heat Exchanger

vector H. If O is the point about which moments are desired, the angular moment about O is given:

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Fluid Mechanics Lab

APPLICATION OF THE COUPLED THREE DIMENSIONAL THERMAL- HYDRAULICS AND NEUTRON KINETICS MODELS TO PWR STEAM LINE BREAK ANALYSIS

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

M.S. Project Report. Efficient Failure Rate Prediction for SRAM Cells via Gibbs Sampling. Yamei Feng 12/15/2011

Universality and Scale Invariance in Hourly Rainfall Pankaj Jain, Suman Jain and Gauher Shaheen

AP Statistics Cumulative AP Exam Study Guide

Mechanisms of Vortex Oscillation in a Fluidic Flow Meter

Chapter 11. Correlation and Regression

Efficient runner safety assessment during early design phase and root cause analysis

VD1 CLC. Small Valves DIN-range with a higher k v -value

Chapter 2. Random Variable. Define single random variables in terms of their PDF and CDF, and calculate moments such as the mean and variance.

Basic Concepts in Data Reconciliation. Chapter 6: Steady-State Data Reconciliation with Model Uncertainties

6 Securing of the delivery and acceptance

TOLERANCES AND UNCERTAINTIES IN PERFORMANCE DATA OF REFRIGERANT COMPRESSORS JANUARY 2017

Natural Frequencies Behavior of Pipeline System during LOCA in Nuclear Power Plants

ENGINEERING OF NUCLEAR REACTORS

s and FE X. A. Flow measurement B. properties C. statics D. impulse, and momentum equations E. Pipe and other internal flow 7% of FE Morning Session I

Study on the improved recuperator design used in the direct helium-turbine power conversion cycle of HTR-10

Heat Exchangers for Condensation and Evaporation Applications Operating in a Low Pressure Atmosphere

Ultrasonic Gas Flow Meter

A Robust Semi-Analytical Method for Calculating the Response Sensitivity of a Time Delay System

Onset of Flow Instability in a Rectangular Channel Under Transversely Uniform and Non-uniform Heating

Rate-Quality Control Method of Identifying Hazardous Road Locations

Condition monitoring of steam generator by estimating the overall heat transfer coefficient

Transcription:

Journal of Marine Science and Application, Vol.6, No., January 26, PP***-*** Condition Monitoring for Maintenance Support BEERE William, BERG Øivind, WINGSTEDT Emil SAVOLAINEN Samuli 2, and LAHTI Tero 2. Institute for Energy Technology, OECD Halden Reactor Project, Norway 2. Fortum Power and Heat Oy, Loviisa Power Plant, Loviisa, Finland Abstract: Considerable advancement has been made in computer and information technology that can benefit safety and economy in Operation and Maintenance (O&M). However, before implementing new technology in nuclear power plants there is a need for qualification of methods and related tools. The OECD Halden Reactor Project (HRP) has taken an active role in facilitating implementation of technology advances and in particular application of condition monitoring techniques for maintenance support. TEMPO [] is a system based on physical models for thermal performance monitoring and optimization developed at the HRP. The system aims at satisfying information needs associated with condition monitoring, on-line calibration monitoring of plant measurements, process fault detection and diagnosis. The data-reconciliation [2] method used in TEMPO relies on fitting a simulation of the turbine cycle to the actual plant data. The difference between measurements and calculated values (residuals) are monitored to detect deviations. Each measurement point is assigned an uncertainty. How well the simulation fits to the measurements is compared to the given uncertainty. Traditionally this comparison is directly used to determine if there is a fault in the measurement. By using a time series analysis of plant data, changes below single point statistical significance can be found. Variations in both individual residuals and the global object function, i.e. the sum of all residuals, are small and their values mostly static. Thus, trending the global object function value is important in order to identify possible faults. Comparing residuals with past behaviour enhances fault detection compared with a statistical analysis of each data point. An eample of fault detection is given from the analysis by TEMPO of data from the Loviisa 2 NPP in Finland. Keyword: Condition Monitoring, Maintenance Support. CLC number: Document code: A Article ID: 67-9433(27)-- Introduction The focus of this paper is the analysis using the data-reconciliation toolbo TEMPO on data obtained from the Loviisa 2 NPP in Finland. Instead of looking at case studies for only a few data sets, data from a whole year has been used for this analysis. This has lead to a better method for fault detection. The data-reconciliation method used in TEMPO relies on fitting a simulation of the turbine cycle to the actual plant data. Each measurement point is assigned an uncertainty. How well the simulation fits to the measurements is compared to the given uncertainty. Traditionally this comparison is directly used to determine if there is a fault in the measurement. This requires that the uncertainty is a true representation of the random variance of the measured value. The random variance is difficult to obtain as it includes representivity and modelling inaccuracies. From analysis of real plant data it was found that the measurements showed little random behaviour from one time to another. This leads to the conclusion that a Received date : time series analysis of measurement residuals would result in an earlier detection of faults. This method is described in greater detail in this paper. The analysis of these time series is essential in both validating a model and for the implementation of fault detection routines. The method for fault detection relies on the comparison of the current fit to many previous fits. So reducing the variation of the fit increases the chance of detecting new faults. These considerations for model improvements are discussed in this paper. There is also given an eample of a fault detection procedure from the installation of TEMPO at the Loviisa 2 NPP in Finland. 2 Physical modelling method This section details how a physical model of a thermal cycle can be used for condition monitoring. To use physical models a statistical method is required to fit the model to the measurement data, but an understanding of how to build the model is also required. Both these aspects are discussed in this section.

2 2. Flow sheets and data reconciliation The central assumption in data reconciliation is usually that data are distributed according to the normal (Gaussian) distribution. Maimising the likelihood of a set of estimates for the true values ~ i given a set of data i yields the following minimisation problem [3]: ( ~ ) min i i 2 i σ i subject f (ˆ) = 2 to (Eq. ) where σ i is the standard deviation of i. The plant heat and mass balance and any other relationships that might be included in the model appear in the problem as (non-linear) constraints f ( ˆ ), by which analytical redundancy is introduced. Note that in general the number of dimensions of ˆ is much larger than the number of measurements. What emerges from the solution to (Eq. ) is the plant state most likely to have produced the current set of measurements given their accuracy as epressed in σ i. The value of the sum in (Eq. ) is termed the object function where as its statistical likelyhood is termed the goodness-of-fit. This epresses the probability that the deviations from a perfect fit occurred by chance, and is therefore a quantitative measure of the validity of the model. 2.2 Residuals The objective of data-reconciliation is to fit a physical simulation to measurement data. The difference between fitted values, ~, and measurement values,, is called the residual, v : v = ~ (Eq. 2) Given the statistical uncertainty in the measurement values,, the resulting statistical variation in the σ residual can be determined, σ v (also written as: sigv). The residual is epected to have statistical distribution with a mean value of zero, N(, σ v ) [2], and is related to the measurement uncertainty by, Journal of Marine Science and Application, Vol.6, No., January 27 Where 2 2 ( σ v ) = ( σ ) σ ( ~ ) 2 (Eq. 3) ~ σ is the corrected (or reconciled) uncertainty. This enables the definition of a value called the adjustability. This is the amount a measurement uncertainty can be adjusted due to the analytical redundancy present in the model. The adjustability is defined as, ~ σ a =. (Eq. 4) σ Where a=. for completely redundant measurements and a=. for non-redundant measurements. The degree of redundancy is an indication of how much information there is about the process properties originating from the other measurements. 2.3 Statistical distribution of residuals From data provided by Fortum from Loviisa NPP unit 2, Fig. shows the distribution of measurement residuals for a given time point. These measurement residuals have been plotted against the measurement adjustability. This we term a residual plot. Plotting against the adjustability helps to spread the data out for visual inspection. It is also useful as measurement residuals with very low adjustability are of lower significance for fault detection, [4]. Adjustability.8.6.2 Loviisa 2, 29-3-25 Residual plot Cumalative Dist N(,) N(,.5) -4-3 -2-2 3 4 Residual v/sigv Fig. Residual plot for the 25-3-29 data point. Each dot represents one measurement. The cumulative probability distributions are shown for the actual data, standard distribution, N(,), and a scaled distribution, N(,.5). As can be seen the actual data does not fit the normal standard distribution. A closer fit is obtained.8.6.2 Cumulative probability

NAME Name-name, et al: Title title title title title title title title title title title title title title title 3 for a scaled normal distribution, N(,.5). The eplanation is that the epected normal distribution holds only for an ensemble of instruments, plants and models. For the case considered here there is only one plant, one model and several instruments. In this case the actual data set is a better fit than average, thus the reduced variance of the residual distribution. It is this understanding that leads to the conclusion that for any individual measurement the majority of the random error in the residual is static as the measurement is always for the same instrument channel, plant and compared to the same model. Thus for a residual trend the variation is much lower than the epected statistical distribution. So it is postulated that errors can be detected by comparing the current measurement residual to its historical values. 2.4 Redundancy Redundancy means that there is something which is not absolutely necessary. In this case it is applied to measurements. Measurements give information about the process state at a particular point of the process. A redundant measurement can be removed from the system and the process state can still be determined. The different reasons for this redundancy are described below in this section. 2.4. Physical redundancy A measurement is described as physically redundant when there is one or more other measurement at the same point in the process measuring the same physical quantity. As an eample this could be two temperature sensors or two flow meters. The requirement that they are at the same point needs some degree of fleibility as there will often be some physical separation between measurements. 2.4.2 Analytical redundancy Analytical redundancy states that two or more measurements are related by a physical dependency. A simple eample is a temperature and pressure sensor at the same location. They measure very different quantities, but if there is wet damp at that process location then they are linked by the dependency of saturation pressure with temperature. In this case there is an analytical redundancy. The same can be true of two pressure sensors separated by a flow resistance (which can be just the length of a pipe). They will not read the same pressure, but their pressure difference will be a function of the flow properties between them. In this case there is the possibility to link the two pressures with a physical equation. In general when considering larger systems the relationships between different measurements may be multi-variant and time consuming to analyse analytically. As will be argued in this paper, the analytical redundancy comes from a systematic statistical analysis of the whole system as modelled in a flow sheet. 2.4.3 Apparent redundancy The final type of redundancy discussed here is that which is introduced through the choice of physical model. These measurements are not truly redundant but appear to be due to approimations made in the modelling. This is a separate type of redundancy as the measurements do not belong to the physical or analytical type. This arises from approimations made in making the model. An eample can be measurements surrounding two parallel heat echangers. If the heat echangers are instead modelled as one, which is often done, then some of the physically separate measurements will appear at the same position in the model. Then they will appear to have physical redundancy. 2.5 Modelling equations One needs to be mindful of which assumptions are made when choosing how to model a system. Different types of equations have different considerations for use. 2.5. Fundamental equations The simplest of models are just based on an assumption that there is conservation of mass and energy. Equations used in these simple models we term fundamental equations. They are always valid and require no tuning of parameters. 2.5.2 Analytical equations Then there are analytical equations which are derived from fundamental equations but which rely on certain assumed physical characteristics. An eample is heat transfer to a smoothly flowing liquid where the

4 flow is assumed to be laminar. These types of equations are only valid for a range of conditions. In the eample above the condition for laminar flow needs to be met. Like the fundamental equations no parameters require tuning. 2.5.3 Empirical equations Finally there are the empirical equations. Which are derived from eperiments an eample is the heat transfer in turbulent fluids. The use of these physical equations always carries a certain amount of uncertainty and requires tuning of parameters to the actual system being modelled. They are also only validated for a limited range of physical states. It is this type of physical equation which is most common when modelling the heat cycles of NPPs. 3 Time Series Analysis As mentioned above the ability to detect system faults is greatly enhanced when the fit of a current time point is compared to the fits of historical values. This we term time series analysis. In this section we present an eample of this analysis from data obtained by using the data-reconciliation toolbo TEMPO with data provided by Loviisa 2 NPP, Finland. Trending the global object function value, which gives an indication of the ability of the model to fit the data, is important to identify possible faults. Individual residual trends are important to identify and judge the significance of the fault. Journal of Marine Science and Application, Vol.6, No., January 27 model used in the preliminary study it is epected to mostly detect model or data faults. Fig. 2 shows the calculated global object function value trend for the data set. The variations for fault free data points are low compared to statistical epectation, indicated by the 99% confidence limit also drawn. The faults indicated here are outliers in the data sets, suspicious points (i.e. data sets where the object function value has increased), and changes during the revision period. Here we will discuss the analysis of the suspicions points. Suspicious points are data points where the global object function deviates from previous behaviour. The data point marked as suspicious in Fig. 2 has a substantially higher object function value than the remaining data set. The increased object function was sustained throughout a five days period. Adjustability.9.8.7.6.5.3.2. Residual plot 25-2-3 2 4 6 v/sigv 8 Fig. 3 Residual plot for suspicious data showing measurements whose residuals are significantly different from the previous fault free data. Fig. 2 Time series of global object function, showing limit for 99% statistical confidence limit. Trending the global object function is thus epected to give an overall indication of the state, i.e. if faults are present or not, in the plant. With the heat balance To identify the cause of the problem, a residual plot for a faulty data point is compared with a residual plot for the previous fault free data point. The two measurements with a significantly increased residual are indicated in Fig 3. This fault was then traced to a modelling approimation made in the TEMPO model where parallel condenser units are modelled as a single unit. This is normally a reasonable approimation ecept for this case described above where there was an asymmetry in the sea water flow to the two condensers. The TEMPO model could be etended to

NAME Name-name, et al: Title title title title title title title title title title title title title title title 5 model all condensers individually, should this be desired. However, in normal operation, the condensers are run symmetrically. The etended model would then be unnecessary comple and require more calculation time. 4 Analysis of variances From the analysis of data from a whole cycle the normal ranges of parameters and deviations can be determined. However it should be noted that the data set cannot be assumed fault free. So any deviations could be due to faults, either measurement, equipment or modelling. The significance of the variations can be determined by comparing it to the calculated statistical uncertainty. Variations well below the statistical uncertainty are of no significance; whereas variations larger than the statistical uncertainty are. It is here that the epectations of the different parameter types are discussed. Parameters which should in general vary can be considered as environmental parameters. Eamples are cooling water temperature and turbine outlet pressures. Other parameters will be epected to be fied, such as turbine constants and heat echanger cleanliness. These supposed constants are being used in the empirical physical equations. Here their fitted value will only be constant if the correct physical correlation has been used. This analysis allows for the possibility of fiing parameters, thus moving from a mass and heat balance model to a physical correlation model. Constant parameters can be fied if their variation is small compared to their statistical uncertainty. Fiing parameters whose variation is large compared to the statistical uncertainty will result in a larger variation of the fit value. This will in turn mask possible faults and is thus undesirable. The variation in fit (object function) and the values of the empirical equation parameters forms the basis for comparing model improvements. It is not necessary an improvement to reduce the fit value if its variation, or that of an empirical fitting parameter, increases. As fault detection lies in comparing current measurement deviations to historical ones, then reducing the variation in fit value is the most important goal. 5 Fault detection in Practice The data-reconciliation toolbo TEMPO [,2] is used to analyse one year of data from the Loviisa NPP unit 2. Previously there has been presented analysis of plant data and shown how faults can be detected from inspection of the time series of the key statistical parameters [4]. This method has been used on-line at Loviisa-2 since 25. The following is a description of an actual fault detected at the plant. The on-line installation of TEMPO at Loviisa-2 was configured to perform a calculation daily. The global performance indicator was then checked and if its value was greater then.95 no further action was taken. This value was set from previous eperience of fault free operation. However, on 2 December its value was found to be.68. This prompted further investigation leading to the discovery that the scaled residual values ( v / σ v ) showed a significant increase for three measurements. The trend plot of the Q value and one of the residuals is shown in Fig 4. The measurements concerned are two flows on one of the condensate lines and a steam etraction pressure for the first condensate pre-heater. This led to the conclusion that there was abnormal behaviour in the condensate flow. When the condensate flow was plotted then clear spikes of the flow value could be seen. The cause of these spikes was later traced to a leaking valve. The leak was only ~,3 kg/s but it resulted in first filling up the pipe after the valve, and then suddenly draining into the condenser. After flowing into the condenser, this etra water then resulted in an increase in the condensate flow which was spotted as a deviation in the model fit. The reason for this uneven drain flow is unclear. The fault caused a very small lowering of the plant thermal efficiency, and increased pumping requirements. TEMPO is now at Loviisa-2 running hourly to increase the chance of catching such faults.

6 Journal of Marine Science and Application, Vol.6, No., January 27 Performance inde and scaled residual for RM2F Q v/sigv 6 Acknowledgement Performance inde Q.9.8.7.6.5.3.2. 27-2-8 8 27-2-9 8 27-2-2 8 Data point 27-2-2 43 27-2-2 8 5.5 5 4.5 4 3.5 3 Residual v/sigv The research presented in this paper forms part of the research programme at the OECD Halden Reactor Project. The authors would also like to acknowledge the support they have received through cooperative projects with TVO, Finland. Fig. 4 Fault detection, from goodness of fit key parameter and identification from measurement residual for the main condensate flow. Physical models provide the plant operator with a lot of new information. The problem then becomes what is the key information to follow and what is the follow up information to eamine if a fault is indicated in the key values. In this eample the global object function is the key value with the change in the measurement residuals as the follow up information. The choice of key and follow up information is an important factor in the practical implementation of the data-reconciliation technique. 5 Conclusions This paper has given a brief introduction to the method and application of physical modelling with data reconciliation as applied to thermal heat cycles as NPPs. This methodology discusses the role of empirical equations in the application of physical modelling methods and stresses the importance of time series analysis as opposed to single point statistical analysis. With a time series analysis of one year of plant data using the TEMPO toolbo, changes below normal statistical significance were identified. Variations in residuals were small, and their value mostly static. Thus, comparing residuals with past behaviour detects faults earlier than a statistical analysis of each data point. A systematic method has been developed to enable fault detection and identification based on trending the global objection function as well as measurement residuals. First the global object function value is trended to detect possible faults. Individual residual trends are then used to identify and judge the significance of the fault. References [] S. Sunde et al. Data Reconciliation in the Steam-Turbine Cycle of a Boiling Water Reactor. Nuclear Technology, Vol. 43, August 23. [Journal] [2] F. Madron, Process Plant Performance, Ellis Horwood, 992. [Book] [3] B. R. Martin, Statistics for Physicists, Academic Press, London, 97. [Book] [4] VDI-248, Uncertainties of measurement during acceptance tests on energy conversion and power plants, October 2. [Journal] Mr. ØIVIND BERG Berg was born in 952. He is department head of Computerised Operation Support Systems at Institute for Energy Technology, OECD Halden Reactor Project, Norway. His current research interests include model-based condition monitoring systems. Dr. William H. Å. Beere was born in 972. He is a leader of research in the department of Computerised Operation Support Systems at Institute for Energy Technology, OECD Halden Reactor Project, Norway. His current research interests include model-based condition monitoring systems.