Pittcon P

Similar documents
Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

U.S. EPA Method 8270 for multicomponent analyte determination

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

USEPA Methods 8270 and 8260 on a Single GCMS Without Changing Columns

Report AFK0242/18 TABLE OF CONTENTS

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

GAS CHROMATOGRAPHY (GC)

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

Fast and Accurate Quantitation of Perfluorinated Sources from Textiles using Gas Chromatography-Triple Quadrupole Mass Spectrometry

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Author. Abstract. Introduction

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

EPA Office of Water Method Update Rule Final August 28, 2017 William Lipps October 2017

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Get Selective. By Jaap de Zeeuw

Highly Sensitive and Rugged GC/MS/MS Tool

Headspace Technology for GC and GC/MS: Features, benefits & applications

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

A New Web-Based Application for Modeling Gas Chromatographic Separations

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

GC-CI-MS analysis of TMS derivatives

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

GC/MS Analysis Laboratory Report

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Introduction to GC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Routine MS Detection for USP Chromatographic Methods

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Maximizing Sample Throughput In Purge And Trap Analysis

Principles of Gas- Chromatography (GC)

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Volatile Hydrocarbons (VH) in Waters by GC/FID

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

METHOD 8000A GAS CHROMATOGRAPHY

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Preparative Separation of Active Components from Natural Products using Low-pressure Gradient Preparative HPLC

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Analysis of Low Level Volatile Organic Compounds in Air Anne Jurek

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Introduction to Capillary GC

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Transcription:

PO-CON1701E 76% Increase in Throughput for Determination of Semi-Volatiles Using Narrow-Bore GC Columns and Rapid Data Acquisition with a Highly Sensitive Quadrupole GCMS System Pittcon 2017 1440-14P Brahm Prakash, Tairo Ogura, Riki Kitano, Nicole Lock, Alan Owens, Andy Sandy, Michelle Yang, and William Lipps Shimadzu Scientific Instruments, Columbia, MD, USA

Introduction Laboratories analyzing semi-volatile organics by methods such as Method 625 and Method 8270 typically use 0.25 mm ID capillary columns. Depending on method conditions, simply running the required quality control (QC) samples can consume a significant portion of a 12-hour shift, leaving less time for analysis of revenue-generating samples. A cycle time for a single injection on a standard single quadrupole Gas Chromatograph Mass Spectrometer (GCMS) may be as long as 30 minutes. Thus, in a 12-hour tune cycle with QC, including a continuing calibration verification (CCV), method blank (MB), laboratory control sample (LCS), laboratory control sample duplicate (LCSD), matrix spike (MS), and a matrix spike duplicate (MSD), per analytical batch you may only have time for 18 actual samples before having to verify the tune. Fast GC uses narrow bore (0.15mm ID) columns, rapid oven heating and cooling, and rapid data acquisition to decrease runtime. A sensitive quadrupole mass spectrometer is necessary for identification and quantitation of target compounds at sub-nanogram levels. In addition, fast mass-spectral scanning and data acquisition is required because of the very narrow chromatographic peaks produced under these conditions. The Shimadzu GCMS-QP2020 is a new, sensitive, fast-scanning single quadrupole GCMS system capable of significantly reducing the run time for EPA methods 625 and 8270. Analysis with a 0.25mm x 30 m Column The GCMS-QP2020 highly sensitive mass spectrometer provides excellent sensitivity in split injection mode. Split injection introduces less sample matrix into the column and detector, minimizing instrument maintenance. The split injection improves productivity, allowing a higher starting temperature to shorten runtimes and the oven cooldown time (Figure 1). Figure 1: GC oven cooldown from 330ºC to 60ºC in 4 minutes 2

Taking advantage of rapid oven cooling alone shortens the GC cycle from 30 minutes to 25 minutes. This enables you to run 22 real samples with 10% QC in one 12-hour tune cycle. Raising the starting temperature to 60 ºC instead of 40 ºC shortens the run to 20 minutes allowing 27 samples in a 12-hour period. Table 1 lists the GCMS operating conditions for the 0.25 mm ID column. Using the conditions described in Table 1, all compounds eluted in about 16.5 minutes. The first eluting compound, N-Nitrosodimethylamine, had a retention time of about 2 minutes. Figure 2 is an example TIC chromatogram. The patented, inert, high-efficiency Ion Shield source ensures maximum sensitivity and very little breakdown of even the most active analytes. Figure 2: TIC Chromatogram using a 0.25mm x 30 m column Table 1: GCMS Operating Conditions Column : 0.25mm x 0.25 mm x 30 m RTX-5Sil MS Flow Control using constant linear velocity : 45 cm/ second Pressure : 94.5 kpa Injection Temperature : 295 ºC Total Flow : 47.7 ml / minute Column Flow : 1.52 ml / minute Split ratio : 30:1 GC temperature program : 60 ºC for 1.5 minutes 20 ºC / minute to 330 ºC Hold 4.5 minutes Total GC program time : 19.5 minutes Ion Source temperature : 210 ºC Interface temperature : 300 ºC Solvent cut time : 1.75 minutes Scan range : 35 500 amu Event time : 0.15 seconds Scan speed : 3333 Start time : 1.8 minutes End time : 19.45 minutes 3

Figures 3, 4, and 5 are examples of the instrument calibration and peak shape. Peaks shown are at the lowest calibration level for that compound. Figure 3: 2-Chlorophenol (0.2 µg/ml) Figure 4: Hexachlorocyclopentadiene (0.5 µg/ml) Figure 5: 2-Nitrophenol (1.0 µg/ml) Analysis with a 0.15mm x 20 m Column Changing to a smaller ID column results in narrower peaks and even faster analysis times. This can be a significant advantage, but it requires a fast scanning instrument. Resolution, precision, and peak shape vary depending on the number of scans (data points) across a GC peak (Figure 6); the more scans per peak the better the precision. With scan rates up to 20,000 u per second, the Shimadzu GCMS-QP2020 can easily meet these demands, resulting in faster analysis while maintaining high precision. To ensure adequate precision and accuracy, an event time of 0.1 seconds was necessary. 14% 12% 10% %RSD 8% 6% height Area 4% 2% 0% 5 7 10 18 Data points across peak Figure 6: Increase in precision with more data points across a peak Figure 7: Peak shape improvement with more scans across a peak 4

Table 2: GCMS Operating Conditions Column : 0.15mm x 0.15 mm x 20 m RTX-5Sil MS Flow Control using constant linear velocity : 45 cm/ second Pressure : 281.4 kpa Injection temperature : 295 ºC Total Flow : 47.7 ml / minute Column Flow : 1.01 ml / minute Split ratio : 30:1 GC temperature program : 60 ºC for 1.0 minutes 32.5 ºC / minute to 330 ºC Hold 2.69 minutes Total GC program time : 12.0 minutes Ion Source temperature : 220 ºC Interface temperature : 320 ºC Solvent cut time : 1.0 minute Scan range : 35 500 amu Event time : 0.10 seconds Scan speed : 5000 Start time : 1.05 minutes End time : 11.95 minutes Using the conditions described in Table 2, all compounds eluted within 12 minutes. Figure 8: TIC chromatogram using a 0.15 mm x 20 m column 5

Figure 9: 2-Chlorophenol at 1.0 µg/ml Figure 10: Hexachlorocyclopentadiene 1.0 µg/ml Figure 11: 2-Nitrophenol at 1.0 µg/ml Discussion The original chromatography conditions allowed analysis of only 18 samples during a 12-hour tune interval. Taking advantage of rapid oven cooling increased throughput to from 18 to 22 samples during a 12-hour tune cycle. With a new oven program, 27 samples is possible per 12-hour shift. A narrower bore column decreased the total cycle time from 24 minutes to 17 minutes, increasing throughput to 32 samples. The combination of the fast cooling oven, narrow bore column, and rapid mass spectrometer scanning results in an increase of 14 more samples per 12-hour shift. (See Figure 12). Chromatography does not suffer with the narrow bore column; peaks are simply narrower (Figure 13). 35 Samples per 12-hour tune 30 25 20 15 10 30 25 20 17 minutes per sample Figure 12: CGC run times showing samples run per 12-hour tune interval 6

Figure 13: CGC run times showing samples run per 12-hour tune interval Detection limits with the 0.15 mm ID column showed no statistical difference compared to the 0.25 mm ID column. (Figure 14 T Test) Overall precision (Figure 15 T Test) was slightly better with the 30-meter column, however, the precision for both columns are well within the specifications of EPA Methods 625 and 8270. 0.7992057 Comparison of 20m and 30m column IDLs 0.6992057 0.5992057 IDL µ/l 0.4992057 0.3992057 0.2992057 0.1992057 0.0992057-0.000794-0.100794 20m Column Length 30m Figure 14: T Test comparing 20 meter and 30 meter column IDLs 7

8.9353725 Comparison of 20m and 30m column precision 7.9353725 6.9353725 % RSD 5.9353725 4.9353725 3.9353725 2.9353725 1.9353725 0.9353725-0.064628-1.064628 20m Column Length 30m Figure 15: T Test comparing 20 meter and 30 meter column %RSD Benefits of the Shimadzu GCMS-QP2020 Assume the laboratory work hours enable analysis of samples during two 12-hour tune intervals every day, five days per week. Also, assume that there is 35% downtime due to calibration, quality control, maintenance, and re-runs, with an efficiency of 85%. Decreasing the column ID from 0.25 mm to 0.15 mm and taking % increase = ( ) x 100 [234 133] 133 advantage of rapid oven cooling shortens the sample run time from 30 minutes to 17 minutes. This allowed method modification enables the laboratory to increase throughput from 133 samples to 234 samples per week. The 76% increase in throughput was calculated using the following formula: These examples illustrate the benefit of fast GCMS to increase your labs productivity enabling you to run more samples in less time and make more money. 8

Conclusion Fast oven cooling combined with the rapid scanning mass spectrometer available on the Shimadzu GCMS-QP2020 allows you to shorten analysis times compared to other GCMS instruments. The GCMS-QP2020 is highly precise, highly accurate, and meets or exceeds U.S EPA Method 625 or 8270 requirements. For further information For a more complete discussion of the topics described here, please leave your card or send a request for the full technical report via www.ssi.shimadzu.com First Edition: March, 2017 Shimadzu Corporation, 2017