Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Similar documents
profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Bruker Daltonics. microtof-q. Cutting Edge Performance with Sub-ppm Confidence. ESI-Qq TOF. think forward

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Guide to Peptide Quantitation. Agilent clinical research

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Translational Biomarker Core

Proven robustness for large-scale metabolomics studies using the Phenomics Workhorse

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

IR Biotyper. Innovation with Integrity. Microbial typing for real-time epidemiology FT-IR

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Technical Note # TN-35 amazon Ion Trap: New Performance Levels Meeting Demanding Analytical Requirements

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

WALKUP LC/MS FOR PHARMACEUTICAL R&D

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Thermo Finnigan LTQ. Specifications

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

ABI 3200 Q TRAP LC/MS/MS System

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

ETD Verification Kit

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

ETD Verification Kit II

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Technical Note # TN-24 Extending the Capacity in Modern Spherical High Capacity Ion Traps (HCT)

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Defining quality standards for the analysis of solid samples

Agilent All Ions MS/MS

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Analytical Instrumentation

883 Basic IC plus. The smallest Metrohm ion chromatograph

Finnigan LCQ Advantage MAX

High-Field Orbitrap Creating new possibilities

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Routine MS Detection for USP Chromatographic Methods

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry

Varian Galaxie Chromatography Data System for Preparative HPLC

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Introducing 7820A GC System. Reliability, Simplicity & Affordability!

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Pulsar. Delivering NMR to your benchtop

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

IN QUALITATIVE ANALYSIS,

The Power to See What You ve Never Been Able to See Before. Innovation with Integrity. Qq-FTMS

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Computational Methods for Mass Spectrometry Proteomics

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

MS-based proteomics to investigate proteins and their modifications

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Using the Agilent 1290 Infinity II Multicolumn Thermostat with Extreme Temperatures and Flow Rates

Protocol. Product Use & Liability. Contact us: InfoLine: Order per fax: www:

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

LECTURE 2. Advanced Separation Science Techniques Present and Future Separation Tools

FLASH CHROMATOGRAPHY

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

Isotopic-Labeling and Mass Spectrometry-Based Quantitative Proteomics

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Reagents. Affinity Tag (Biotin) Acid Cleavage Site. Figure 1. Cleavable ICAT Reagent Structure.

MetWorks Metabolite Identification Software

THE TRIPLE QUAD THAT KNOWS THE VALUE OF TIME. QSight Triple Quadrupole LC/MS/MS Platform. For research use only. Not for use in diagnostic procedures.

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Polymer analysis by GPC-SEC. Technical Note. Introduction

HPLC Praktikum Skript

Transcription:

Bruker Daltonics EASY-nLC Tailored HPLC for nano-lc-ms Proteomics think forward Nano-HPLC

World-Class Performance with a Small Footprint Bruker Daltonics presents a nano-lc system, perfectly integrated with mass spectrometry: The EASY-nLC TM. One Click separation of components It is easy to handle, steady and reliable. It is a 1D-nanoflow HPLC system tailored to the requirements of today s proteomics applications. It is the straightforward gateway to proteomics discovery and provides the researcher with: Simplicity: Easy installation & operation Reliability: Robust & steady Low-Maintenance: Split-free gradient mixing Efficiency: minimum peak widths < 5 sec. Compact Design with small footprint Maximize productivity Easy-nLC operation is optimized for Bruker Daltonics mass spectrometry instrumentation, whether it is connected online to HCT ion traps, microtof ESI- TOF systems, the apex FTMS sytems or the PROTEINEER-fc MALDI sample collector for offline measurements with FLEX series MALDI-TOF/TOF instruments. Intuitive and simple software allows the integrated control of the whole experiment. Ease Of Use and Split-Free Flows The EASY-nLC is a compact, innovative and affordable nano-hplc system for state-of-the-art proteomics laboratories. Split-free binary gradient mixing down to the low nanolitre/min range are made possible by precise direct drive pumps. Bruker Daltonics Compass TM software environment fully integrates the EASY-nLC with Bruker Daltonics mass spectrometry systems.

Reliable Operation for LC-MS Applications Samples overlay demonstrate reproducibility Excellent reproducibility with complex samples Using a standard configuration consisting of trapping and analytical column, the system delivers excellent chromatographic reproducibility even in very short gradients of 10 min and complete acquisition runtimes of 20 min. Excellent chromatographic reproducibility. 15 chromatograms of 100 fmol BSA are shown in overlay. Retention time reproducibility for m/z 722.5: RSD = 0.11%. Rapidness: 4 seconds peak widths Chromatographic performance Outstanding performance is achieved by optimization of dead volumes and flow paths. This results in Extracted Ion Chromatograms with peak widths of 4 seconds as shown for 100 fmol BSA on column. MS measurement was performed with HCTultra system. Thus, mass spectrometry based evaluation is enhanced by superior separation capabilities at the front end.

Performance in Sample Separation 10 minutes gradient C o n c. [% ] The comprehensive solution for complex proteomics samples EASY-nLC in combination with Bruker Daltonics mass spectrometers guarantees excellent data and evaluation options. Benefit from the advanced LC-MS combination in applications like proteomics profiling, bottom-up analysis, and characterization of post-translational modifications (PTM) or quantitation. 8 0 6 0 4 0 2 0 0.0 2.5 5.0 7.5 1 0.0 1 2.5 1 5.0 1 7.5 2 0.0 T im e [m in ] Base peak chromatogram of a mix of 15 proteins (200 fmol each on column) using a C 18-column (10 cm length, 75 μm ID, 3 μm particle size). It s robust, fast and reliable A nano-lc run can readily be performed in 20 minutes using the EASYnLC. Within the Compass software environment, BioTools TM software precisely lists all identification results in less than 45 minutes. Designed for the interpretation of MS and MS/MS spectra of protein digests and peptides, BioTools benefits from EASY-nLC s superior separation capabilities. Combined with Bruker Daltonics MS instrumentation, accelerated data evaluation is enabled for demanding mass spectrometric analysis. Finally, ProteinScape TM provides overview and organization of all project data. Enhanced reporting and easy navigation allows for appropriate data output, like sequence view, LC-MS survey view and search results on protein and peptide level. Furthermore, ProteinScape enables automated analysis by handling interaction with database search engines, improving identification rates, generating non-redundant protein lists and quantitative proteomics for labelfree as well as stable isotope labeled samples. Proteins identifications Identification result of m/z 850.41 (a peptide of α-lactalbumin) with BioTools: The annotated spectrum shows excellent b- and y-ion series. A mix of 15 proteins (200 fmol/protein) was evaluated with an acquisition time of 25 minutes. The sample was measured on an HCTultra. Informations at a glance At a glance: ProteinScape 2 shows protein and peptide table, protein sequence and a LC-MSsurvey view. Evaluation was performed from the same sample as above.

Delivering Excellent Results in Proteomics Easy installation and handling The EASY-nLC is the first plug&play HPLC system for today s proteomics applications. The system is easily controlled by the intuitive and familiar Bruker Compass TM HyStar TM software from hardware setup to method definition, sample definition and data acquisition. While standard HPLC operations, like solvent purging, air removal and column flushing are performed automatically, first analytical data are easily available 4 hours after power-up. Split free liquid flow system Precise nanolitre pumps allow very exact split free binary gradient mixing. Advanced Flow Control (AFC TM ) ensures accuracy and reproducibility with two nanoflow sensors one for each mobile phase and also allows individual and automatic calibration of the two solvents. The system is optimized for low dead vo lumes and short flow paths, minimizing solvent use and waste. Without flowsplitting, a reproducible low flow starting at 20 nl/min is possible. Performance Outstanding chromatographic performance is demonstrated by immediate delivery of chromatograms with peak widths (FWHM) around 3-5 seconds. In a standard automatic configuration, the system delivers a chromatographic reproducibility in complex mixtures with retention time RSDs (Relative Standard Deviation) better than 0.4%, typically between 0.15% and 0.25%. Comprehensive support All components are laid out in a logical and easily accessible manner. Bruker Daltonics comprehensive service concept includes instrument features like automated self-diagnosis routines and remote service capabilities for online support. System components can be easily accessed for straightforward service and maintenance to enhance turnround times. The liquid flow system. The split-free nanoflow starts at 20 nl/min. AFC Solvent A Advanced Flow Control system Solvent B Waste

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL 01-2008, LS-33 Technical Specifications Performance Easy operation Split-free flow down to 20 nl/min Pulse-free flow Innovative design for 1D separations with and without trapping column AFC allows automatic calibration of solvents Highly reproducible chromatograms Chromatographic performance with peak widths around 3-5 seconds No online degassing required Pre-defined routines for purging and bubble removal Layout Cooled autosampler (down to 4 C) Accommodates 24 sample vials or 1 microtiter plate with 96 or 384 wells. 3 nanolitre pumps, capable of up to 340 bar 4 high pressure valves Pressure sensors on each pump and accurate nano-flow sensors Compass software suite Integration in Compass Software Interface for hardware setup, method definition, sample setup, and data acquisition. Optional Compass Security Pack for work in regulated environments (21CFR part 11 compliance) Service features Remote on-line service capability via Internet sessions Extended self diagnostics Supplementary IQ/OQ/PV procedures available Integration EASY-nLC is optimized for online measurements with Bruker Daltonics esquire and HCT series ion traps, microtof ESI-TOF mass spectrometers, apex ultra series FTMS and the PROTEINEER fc fraction collector for offline MALDI-TOF/TOF measurements with FLEX series instruments. For research use only. Not for use for diagnostic purposes. EASY-nLC TM is a trademark of Proxeon A/S, Odense, Denmark www.bdal.com Bruker Daltonik GmbH Bremen Germany Phone +49 (421) 2205-0 Fax +49 (421) 2205-103 sales@bdal.de Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) 663-3660 Fax +1 (978) 667-5993 ms-sales@bdal.com