EXPERIMENTAL STUDY OF THE DISCHARGE COEFFICIENT

Similar documents
Building and Environment

Buoyancy-Driven Single-Sided Natural Ventilation in Buildings with Large Openings Yi Jiang a and Qingyan Chen b,*

This is the published version of a paper presented at Healthy Buildings 2017 Europe, Lublin, Poland.

AIJ COOPERATIVE PROJECT FOR PRACTICAL APPLICATIONS OF CFD TO URBAN VENTILATION

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Anemometer Calibration Requirements for Wind Energy Applications

REYNOLDS NUMBER EFFECTS ON HEMISPHERICAL DOMES IN SMOOTH FLOW

PRESSURE BOUNDARY CONDITIONS IN MULTI-ZONE AND CFD PROGRAM COUPLING

Numerical Study of Convective Heat Transfer for Flat Unglazed Transpired Solar Collectors

Uncertainty in airflow field parameters in a study of shock waves on flat plate in transonic wind tunnel

Combined GIS, CFD and Neural Network Multi-Zone Model for Urban Planning and Building Simulation. Methods

Investigation of Opening Positions on the Natural Ventilation in a Low-Rise Building by CFD Analysis

FE Exam Fluids Review October 23, Important Concepts

Study of air curtains used to restrict infiltration into refrigerated rooms

Proceedings of CLIMA 2000 World Congress, Brussels, Belgium. Simplified Method for Indoor Airflow Simulation

Unsteady Volumetric Entropy Generation Rate in Laminar Boundary Layers

Experimental Investigation of the Aerodynamic Forces and Pressures on Dome Roofs: Reynolds Number Effects

ENHANCED MODELLING OF INDOOR AIR FLOWS, TEMPERATURES, POLLUTANT EMISSION AND DISPERSION BY NESTING SUB-ZONES WITHIN A MULTIZONE MODEL

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Iqbal, Ahsan; Afshari, Alireza; Heiselberg, Per Kvols; Høj, Anders

NATURAL VENTILATION DESIGN FOR LOW-RISE BUILDINGS: COMPARISON BETWEEN A NODAL MODEL AND WIND TUNNEL TESTS

Natural Convection Heat Loss from A Partly Open Cubic Enclosure Timothy N Anderson 1,a * and Stuart E Norris 2,b

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

Laminar Flow. Chapter ZERO PRESSURE GRADIENT

Design and simulation of Open Circuit Blowdown type Wind Tunnel

Flow Distribution inside an Electrostatic Precipitator: Effects of Uniform and Variable Porosity of Perforated Plate

This is the author s version of a work that was submitted/accepted for publication in the following source:

Numerical Study on Flow Field for a Solar Collector at Various Inflow Incidence Angles *

ABSTRACT I. INTRODUCTION

Aalborg Universitet. Windows Heiselberg, Per Kvols; Svidt, Kjeld; Nielsen, Peter Vilhelm. Publication date: 2000

NUMERICAL SIMULATION OF CONJUGATE HEAT TRANSFER FROM MULTIPLE ELECTRONIC MODULE PACKAGES COOLED BY AIR

Flow Measurement in Pipes and Ducts COURSE CONTENT

Table of Contents. Foreword... xiii. Preface... xv

Experimental Investigation on the Acoustic Scattering Matrix for a Centrifugal Pump

Decay of Rotational Airflow with Flow Conditioner in Larger Diameter Ducts for Dust Concentration Measurement using Isokinetic Sampling

Wind Tunnel at LABINTHAP (Updated)

Correction of the wall interference effects in wind tunnel experiments

ANALYZING WIND-DRIVEN RAIN ON A BUILDING FACADE USING THE LASER PRECIPITATION MONITOR (LPM)

PARTICLE DISPERSION IN ENCLOSED SPACES USING A LAGRANGIAN MODEL

Vortex shedding from slender surface mounted pyramids

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Improved numerical simulation of bridge deck aeroelasticity by model validation

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

Orifice and Venturi Pipe Flow Meters

Fluid Dynamics Exercises and questions for the course

MATHEMATICAL MODELING OF A COMBINED HOT-WATER HEATING SYSTEM BY MEANS OF THE FINITE ELEMENT METHOD

1) the intermittence of the vortex-shedding regime at the critical angle of incidence in smooth flow; ) the inversion of the lift coefficient slope at

APPLIED FLUID DYNAMICS HANDBOOK

Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

SPATIAL DISTRIBUTION OF PRESSURE DRAG ACTING ON RECTANGULAR BLOCK ARRAYS WITH VARIOUS LAYOUTS

STUDY ON THE THERMAL PERFORMANCE AND AIR DISTRIBUTION OF A DISPLACEMENT VENTILATION SYSTEM FOR LARGE SPACE APPLICATION

Comparison of Numerical Prediction of Pressure Coefficient on Rectangular Small Building

Atrium assisted natural ventilation of multi storey buildings

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

N. Zhang, W.-J. Yang and Y. Xu Department of Mechanical Engineering and Applied Mechanics, The University of Michigan, Ann Arbor, MI 48109, USA

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

Compressed Air Discharge from a Blowing Unit

Study on the natural air cooling design of electronic equipment casings: Effects of the height and size of outlet vent on the flow resistances

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

Applied Fluid Mechanics

Applied Fluid Mechanics

INFLUENCE OF THE GEOMETRICAL PARAMETERS OF URBAN CANYONS ON THE CONVECTIVE HEAT TRANSFER COEFFICIENT

Side-View Mirror Vibrations Induced Aerodynamically by Separating Vortices

Active Control of Separated Cascade Flow

IMPACT OF THE ATMOSPHERIC BOUNDARY LAYER PROFILE ON THE VENTILATION OF A CUBIC BUILDING WITH TWO LARGE OPPOSITE OPENINGS

EVALUATION OF VENTILATION PERFORMANCE IN VOID SPACE BY EXCEEDANCE PROBABILITIES BASED ON CFD SIMULATION

Water Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:

Simplified Numerical Models for Complex Air Supply Diffusers Jelena Srebric *, Ph.D.

Fluid Flow and Heat Transfer of Combined Forced-Natural Convection around Vertical Plate Placed in Vertical Downward Flow of Water

Parabolic Flow in Parallel Plate Channel ME 412 Project 4

CFD Prediction of Airflow in Buildings for Natural Ventilation. Robert N. Meroney. Prepared for. 11 th Americas Conference on Wind Engineering

Performance Assessment of PV/T Air Collector by Using CFD

Lecture 13 Flow Measurement in Pipes. I. Introduction

* Ho h h (3) D where H o is the water depth of undisturbed flow, D is the thickness of the bridge deck, and h is the distance from the channel floor t

Prediction of wind load acting on telecommunication masts

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

Wind Pressure and Air Flow in a Full-Scale Building Model under Cross Ventilation

Experimental and Numerical Investigation of Flow over a Cylinder at Reynolds Number 10 5

TURBULENCE AND PRESSURE DROP BEHAVIORS AROUND SEMICIRCULAR RIBS IN A RECTANGULAR CHANNEL

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

Flow Measurement in Pipes and Ducts COURSE CONTENT

Fluid Mechanics Answer Key of Objective & Conventional Questions

GRAVITY EFFECT ON THE DISTRIBUTION OF REFRIGERANT FLOW IN A MULTI-CIRCUITED CONDENSER

VALIDATION OF LES FOR LOCAL HEAT ENVIRONMENT IN TOKYO -COMPARISON WITH FIELD MEASUREMENT DATA-

Study on Stack Effect of Stairwell by Numerical Model of Leakage Flow through Gap of Door

DEVELOPMENT OF A NUMERICAL APPROACH FOR SIMULATION OF SAND BLOWING AND CORE FORMATION

DISCRETE ELEMENT SIMULATIONS OF WATER FLOW THROUGH GRANULAR SOILS

A two-fluid model of turbulent two-phase flow for simulating turbulent stratified flows

A Numerical Investigation on Active Chilled Beams for Indoor Air Conditioning

Natural Ventilation. CFD modelling of a double-skin facade. Huw Birch. Supervisor: Abigail Hathway

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Detached Eddy Simulation on Hypersonic Base Flow Structure of Reentry-F Vehicle

Quantifying Factors Affecting Sidewall Air Inlet Performance

Masters in Mechanical Engineering. Problems of incompressible viscous flow. 2µ dx y(y h)+ U h y 0 < y < h,

Mestrado Integrado em Engenharia Mecânica Aerodynamics 1 st Semester 2012/13

THE GEOTHERMAL TWO-PHASE ORIFICE PLATE

VERTICAL TURBULENT BUOYANT HELIUM JET CFD MODELING AND VALIDATION

coh R 1/2 K x = S R 1R 2 (K x) S R 1 (K) S R 2 (K) (3) Davenport (1961) proposed one of the first heuristic root-coherence expressions for longitudina

Aalborg Universitet. Publication date: Document Version Publisher's PDF, also known as Version of record

Lecture 3 The energy equation

Transcription:

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan EXPERIMENTAL STUDY OF THE DISHARGE OEFFIIENT OF INTERNAL OPENINGS IN PARTITIONED BUILDINGS hia R. hu 1 and Yu-Wen Wang 1 Professor, Department of ivil Engineering, National entral University Taoyuan ounty, Taiwan, crchu@cc.ncu.edu.tw Department of ivil Engineering, National entral University Taoyuan ounty, Taiwan, sty03@hotmail.com ABSTRAT This experimental study uses wind tunnel experiments to investigate the discharge coefficient and flow rate of wind-driven cross ventilation in partitioned buildings. The discharge coefficients of internal openings under different flow conditions were determined by a fan technique. It is found that the internal discharge coefficient is a function of internal porosity, but independent of external porosity and opening location. Based on the experimental results, a predictive model for the internal pressure of multi-room buildings is developed and verified. This model could be used to predict the flow rate through multi-room buildings once the external pressure distribution and opening areas are known. KEYWORDS: BUILDING VENTILATION, DISHARGE OEFFIIENT, WIND TUNNEL EXPERIMENT Introduction Wind-driven natural ventilation has been demonstrated to be an effective way for maintaining a comfortable and healthy indoor environment [Linden (1999), Santamouris and Wouters (006)]. The flow rate of wind-driven ventilation is dependent on the external wind conditions, building designs and internal partitions [Etheridge and Sandberg (1996)]. Therefore, a reliable prediction method is important to apply wind-driven ventilation for domestic and commercial buildings. Predictive models for building ventilation can be divided into two main categories: omputational Fluid Dynamics (FD) models and multi-zone models. FD models calculate the air flow inside the building based on the continuity equation and the Navier-Stokes equations [hang et al. (003)]. However, Dascalaki et al. (1999) indicated that FD models are difficult to use for practical design purposes due to the complexity of the modelling procedure and the intricacy in describing real conditions. On the other hand, multi-zone models compute the flow rate and mass transfer rate between different zones of the building based on the mass conservation and energy balance equation. Several researches used multi-zone models, such as OMIS [Zhao et al. (1998) and Feustel (1999)], ONTAM [Haghighat and Megri (1996)] and POMA [Haghighat et al. (001)] to simulate air flow rate and indoor air quality in the building, and compare the interzonal air flow rate with the results of FD models and tracer gas method. Most of these multi-zone models used the orifice equation to calculate flow rate through the internal opening between two rooms:

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan P Q A ρ (1 r ) i i = zi i a i where P i = P i1 P i is the pressure difference across the internal opening, ρ a is the air density, A i is the area of the internal opening, = A i /A w is the ratio of area of the internal opening A i to the area of internal wall A w, is the internal discharge coefficient. Dascalaki et al. (1999) compared experimental data and calculated results using OMIS, found the discharge coefficient = 5 for the internal openings. Tan and Glicksman (005) suggested the internal discharge coefficient = 0.95 for small openings. Allard and Santamouris (006) indicated that the value of is a function of the dimensions of the opening. For small internal openings, a typical value for is 5. For large internal openings, has a value close to unity. hu et al. (009), based on wind tunnel experiments, found that the discharge coefficient of external opening is dependent on wind direction, wall porosity and opening Reynolds number. The opening Reynolds numbes given by: u d Re = () ν where u = Q/A o is the average velocity at the opening, d is the characteristic diameter of the opening, and ν is the kinematic viscosity of air. Top view (1) U P i1 P i A 1 A Q 1 Q A i Q i Figure 1. Schematic diagram of wind-driven ventilation in a partitioned building. For buildings that were separated into two rooms by an internal partition as shown in Figure 1. The windward side, leeward side and internal partition each has one opening. The windward opening area is A 1, the leeward opening area is A, and internal opening area is A i. The dimensionless average velocity at the windward opening can be derived from the continuity equation and Eqn. (1): u1 α z1 pe1 pe U = α1 + α + α1α(1- ri ) (3) where U is the external wind velocity, p is the pressure coefficient, = A i /A w is the internal wall porosity, subscripts 1 and, e and i, represent the windward and leeward sides, the external and internal openings, respectively. oefficientα1 = A r1 zr1, α = A r zr, where zr are the ratios of discharge coefficients: z1 z zr1 = zr = (4) zi zi Ratios of opening areas are defined as: 1

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan A A 1 r1 = Ar Ai Ai The dimensionless average velocity at the internal opening is: A = (5) u i α1 α (1 ri ) = zi pe1 pe (6) U α1 + α + α1 α (1 ri ) Based on Eqns (1) and (3), it can be shown that the internal pressure coefficient of room 1 equals to: α(pe1 pe) pi1 = pe1 (7) α1 + α + α1α (1- ri ) and internal pressure coefficient of room equals to: α1 (pe1 pe) pi = pe + (8) α + α + α α (1- r ) 1 The equations shown above can be used to predict the internal pressure coefficients pi1, pi and inlet velocity u 1 /U once the external pressure coefficients pe1 and pe, discharge coefficients z1 and z and the internal porosity are known. Based on the studies cited above, there is a need to elucidate the relationship between the internal discharge coefficient and opening size, partition configuration. This study used wind tunnel experiments systematically investigate the influences of external wind speed, opening size and partition configuration on the internal flow rate and the discharge coefficient. The discharge coefficients of various flow conditions were determined by a fan technique. The experimental results will also be used to verify the above model. 1 i 1 Experimental Setup The experiments were carried out in an open-circuit, blowing-type wind tunnel. The total length of the wind tunnel was 8.3 m, the test section of wind tunnel was 1. m wide and m high, and the wooden platform was 1.80 m long, m wide. The schematic diagram of the experimental setup is shown in Figure. Anemometer m Model m Room1 Room Nozzle meter Fan P i1 P i P e1 1.5 m 0.19 m Wood platform P Pressure Gage Data Logger Figure : Schematic diagram of experimental setup.

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan A cubic model with external dimensions: width and height H = 0 m, was mounted on the centerline of the platform. The distance from the beginning of the test section to the model was 1.5 m. The surfaces of the model were made of smooth acrylic plate (thickness 4.8 mm) with square-shaped opening (diameter d = 40, 60 and 100 mm) at the center of the plate. The space inside the model was evenly separated into two zones by an internal partition plate. The plate was also made of acrylic with square-shaped opening (diameter d i = 0, 30, 40, 50, 60, 80 and 100 mm) at three different locations (center, edge and corner). The external and internal pressures were measured by a multi-channel high-speed pressure scanner (ZO33/64PX, Scanivalve Inc.). The measuring range of the pressure sensor was ± 758 Pa, with a resolution of ±. Pa. The sampling frequency was 100 Hz, and the sampling duration was 163.84 sec. The pressures were measured as pressure differences from the reference static pressure near the inlet of the test-section. The windward side pressure distribution was found to be unaffected by the size of the opening. The fan technique described by hiu and Etheridge (007) was adopted in this study in order to determine the internal discharge coefficients of different flow conditions. The flow rate can be controlled by a fan, and the resulting pressure difference across an opening can then be measured. The mean flow rate, Q, was measured by a nozzle meter. When the fan technique was used, a porous plate (150 mm x 150 mm) was installed inside the model in order to alleviate the effects of suction and blowing on the flow field inside the model. For cross ventilation, the locations of windward and leeward openings were at the center of the wall. But there are three different configurations for the internal opening in this study: (1) ase 1: internal opening at the center of the partition wall; () ase : internal opening at the edge of the partition wall; (3) ase 3: internal opening at the corner of the partition wall. The wind direction is defined as the incidence angle of the approaching flow; the windward facade was normal to the wind when wind direction θ = 0 o. Results and Discussion This section describes the experimental results of the internal discharge coefficients of different flow conditions. The range of Reynolds numbes 5,000 ~ 40,000, which is close to the typical value of Reynolds number for real buildings. In this part of the experiment, the leeward opening was connected to a porous plate, a nozzle meter and a fan. The external wind speed U = 17.5 m/s, and wind direction θ = 0 o, for all the cases. Figure 3 illustrates the relationship between the internal discharge coefficient and Reynolds number for different opening configurations (ase 1 ~ 3). External windward porosity = A 1 /A w = 6.5% (opening d 1 = 100 mm). It can be seen that the internal discharge coefficients are independent of Reynolds number and opening configurations except for the flow condition: = 6.5% in ase 1. The average value of = 0.94 when = % (d i = 40 mm) for all three different opening configurations (ase 1 ~ 3) was very close to the value of 0.95 suggested by Tan and Glicksman (005) for small internal openings. In addition, the value = 9, when =.5% (d i = 60 mm) and = 3 when = 6.5% (d i = 100 mm) were close to 5 suggested by Dascalaki et al. (1999) fonternal door. These results demonstrated that the internal discharge coefficient is a function of the opening size. Figure 4 shows the relationship between internal discharge coefficient and Reynolds number for different internal porosities. External porosity = 6.5%, opening configuration ase 3. The internal discharge coefficient > 1 when internal porosity < %. This is due to the orifice equation can not be used to calculate the internal flow rate when the internal porosity < %.

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan (a) 0. ase 1, = % ase, = % ase 3, = % 0 5000 10000 15000 0000 5000 30000 35000 Re (b) 0. ase 1, =.5% ase, =.5% ase 3, =.5% 0 5000 10000 15000 0000 5000 30000 35000 Re (c) 0. ase 1, = 6.5% ase, = 6.5% ase 3, = 6.5% 0 5000 10000 15000 0000 5000 30000 35000 Re Figure 3. Internal discharge coefficients as a function of Reynolds number for different opening configurations. External porosity = 6.5%. (a) internal porosity = %; (b) internal porosity =.5%; (c) internal porosity = 6.5%.

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan.4.0 1.6 1. = 0.5% = 0.56% = % = 1.56% =.5% = 4.0% = 6.5% 0 10000 0000 30000 40000 50000 Re Figure 4. Internal discharge coefficients as a function of Reynolds number for different internal porosities. External porosity = 6.5%, opening configuration is ase 3. Figure 5 plots the internal discharge coefficient as a function of the internal porosity. The internal discharge coefficient decreased as the internal porosity increased, and the decrease rate slowed down when > 4.0% and reach a constant value = 0. Based on the results of = % ~ 6.5%, an empirical relation between and can be found: 01ri zi = (9) r 0355 i 1. 0. = %, ase 3 =.5%, ase 3 = 6.5%, ase 3 = 6.5%, ase = 6.5%, ase = 6.5%, ase Eqn (9) 0 4 6 8 Figure 5. Relationship between internal discharge coefficient and internal porosity. This section discusses the experimental results of wind-driven cross ventilation through partitioned building. The windward and leeward wall each has one opening at the center. The internal opening at three different locations: (1) at the center of the partition wall; () at the edge of the partition wall; (3) at the corner of the partition wall. In this part of the

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan experiment, the fan, porous plate, and nozzle meter were not used. The external wind speed U = 17.5 m/s and wind direction θ = 0 o, for all the cases. 1.5 ase 1, measured ase, measured ase 3, measured Model prediction pi1 0.5-0.5 1 0.1 1 10 100 A /A 1 Figure 6. Internal pressure coefficient of room 1 as a function of opening ratio A /A 1 for different cases. Internal porosity = 6.5%. The internal pressure coefficient pi1 is plotted as a function of opening ratio A /A 1 for different partition configurations in Figure 6. The symbols are the measured internal pressure coefficients, and the lines are the predictions of Eqn. (7). The internal pressure coefficient pi1 is close to windward pressure coefficient pe1 when A /A 1 << ; whereas when A /A 1 >>, the internal pressure coefficient pi1 was close to leeward pressure coefficient pe. The agreement between predicted and measured pressure coefficients demonstrated that Eqns. (7) could be used to predict the internal pressure coefficient of partitioned buildings. Dimensionless inlet velocity at the windward opening u 1 /U is plotted as a function of opening ratio A /A 1 for different cases in Figure 7. The symbols are the measured velocities at the windward opening, and the lines are the predictions of Eqn. (3). The good agreement between the measured and predicted inlet velocities demonstrated that Eqn. (3) can be used to predict the flow rate in partitioned buildings. onclusions This experimental study examines the applicability of orifice equation for partitioned buildings. The values of internal discharge coefficient for different opening sizes and flow conditions were measured by a fan technique. It was found that the internal discharge coefficients were dependent on the internal porosity, but independent of external porosity and opening configuration. The relationship between the internal discharge coefficient and internal porosity was then used to calculate the internal pressure coefficients and average inlet velocity for three different opening configurations: internal opening at the center of partition wall; internal opening at the edge of partition wall; internal opening at the corner of partition wall. The agreement between predicted and measured internal pressure coefficients demonstrated that the orifice equation can be used to predict internal pressure and flow rate through building openings.

The Seventh Asia-Pacific onference on Wind Engineering, November 8-1, 009, Taipei, Taiwan ase 1, measured ase, measured ase 3, measured Model prediction u 1 /U 0. 1 0.1 1 10 100 A /A 1 Figure 7. Dimensionless velocity at the windward opening plotted as a function of opening ratio A /A 1 for different cases. Internal porosity = 6.5%. References Allard, F., Santamouris, M. (1998) Natural Ventilation in Buildings: A Design Handbook, James and James Ltd. London, U.K. hang, T.J., Hsieh, Y.F., and Kao, H.M. (006) Numerical investigation of airflow pattern and particulate matter transport in naturally ventilated multi-room buildings. Indoor Air, 16,, 136-15. hiu, Y.H., Etheridge DW. (007) External flow effects on the discharge coefficients of two types of ventilation opening, Journal of Wind Engineering and Industrial Aerodynamics, 95: 5-5. hu,.r., hiu, Y.-H., hen, Y-J, Wang Y.-W. and hou.-p. (009) Turbulence effects on the discharge coefficient and mean flow rate of wind-driven cross ventilation. Building and Environment, 44, 064-07. doi:10.1016/j.buildenv.009.1. Dascalaki E., Santamouris M., Bruant M., Balaras.A., Bossaer A., Ducarme D, Wouters P., (1999) Modeling large openings with OMIS, Energy and Buildings, 30: 105-115. Etheridge, D., Sandberg, M. (1996) Building Ventilation: Theory and Measurement. John Wiley and Sons Inc. hichester, U.K. Feustel, H.E. (1999) OMIS-an international multizone air-flow and contaminant transport model, Energy and Buildings, 30: 3-18. Haghighat F., Megri, A.. (1996) A comprehensive validation of two airflow models - OMIS and ONTAM, Indoor Air, 6 (4), 78-88. Haghighat F., Li, Y. and Megri, A.. (001) Development and validation of a zonal model POMA, Building and Environment, 36, (9) 1039-1047. Linden P.F. (1999) The Fluid Mechanics of Natural Ventilation, Annual Review of Fluid Mechanics; 31: 01-38. Santamouris, M., Wouters, P. (006) Building Ventilation: The state of the art, Earthscan. Tan, G., Glicksman, L.R. (005) Application of integrating multi-zone model with FD simulation to natural ventilation prediction, Energy and Buildings, 37: 1049-1057. Zhao, Y. Yoshino H. and Okuyama H., (1998) Evaluation of the OMIS model by comparing simulation and measurement of airflow and pollutant concentration, Indoor Air, 8: 13-130.