Installation and test of the MEG Cockroft-Walton accelerator

Similar documents
LXe (part B) Giovanni Signorelli. Istituto Nazionale di Fisica Nucleare, Dipartimento di Fisica and Scuola Normale Superiore, Pisa (Italy)

Electron Beam Polarimetry at JLab Hall C Dave Gaskell PST 2009 September 7, 2009

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Safety Co-ordinator : Patrick Walden, TRIUMF, ext : 7340

Developments for the FEL user facility

accelerating opportunities

Shielding Design for the Imaging and Medical Beamline at the Australian Synchrotron

arxiv: v1 [physics.ins-det] 1 Sep 2009

DIAGNOSTIC TEST-BEAM-LINE FOR THE MESA INJECTOR

Liquid xenon gamma-ray calorimeter for the MEG experiment

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Screens for low current beams

Atomic and Nuclear Physics

Lepton Flavour Violation

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Diagnostics at SARAF

David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Kenji Ozone (ICEPP, Univ. of Tokyo, Japan) Outline. Introduction prototype R&D ー PMTs ー small & large type summary

IPBI-TN June 30, 2004

Timing resolution measurement of a 3 Lanthanum Bromide detector

The scanning microbeam PIXE analysis facility at NIRS

Radioactivity. (b) Fig shows two samples of the same radioactive substance. The substance emits β-particles. Fig. 12.1

SLS at the Paul Scherrer Institute (PSI), Villigen, Switzerland

MEG II 実験の準備状況と 今後の展望 東京大学 素粒子物理国際研究センター 岩本敏幸 他MEG II コラボレーション 2018年9月14日 日本物理学会2018年秋季大会 信州大学 JSPS Core-to-Core Program

Examples for experiments that can be done at the T9 beam line

Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency

2.6 Electron transport lines

Occupational Radiation Protection at Accelerator Facilities: Challenges

Information about the T9 beam line and experimental facilities

Radiation protection considerations along a radioactive ion beam transport line

Status Report on the Survey and Alignment efforts at DESY

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

New Tandetron Accelerator Laboratory at MTA Atomki, Debrecen: Multi-Purpose and Multi-User Facility

arxiv:physics/ v1 3 Aug 2006

Experimental study of nonlinear laser-beam Thomson scattering

UPGRADE AND COMMISSIONING OF THE PIAVE-ALPI ECR INJECTOR AT LNL

3-D MEASUREMENT OF THE NSCL POSITION-SENSITIVE GAMMA RAY DETECTOR ARRAY

arxiv: v2 [physics.ins-det] 17 Jun 2014

STUDY OF THE TRANSVERSE BEAM EMITTANCE OF THE BERN MEDICAL CYCLOTRON

EBSS: Hands-on Activity #8. Operation of an electromagnetic isotope separator (EMIS) Dan Stracener Jon Batchelder

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

Radiation Protection Considerations for the Cryogenic In-Vacuum Undulator of the EMIL Project at BESSY

What have we learned from the LCLS injector?*

Refurbishment of the Electrostatic Accelerators of ithemba LABS

II) Experimental Design

The CNGS neutrino beam

Radionuclide Imaging MII Detection of Nuclear Emission

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

HIGH CURRENT PROTON BEAM INVESTIGATIONS AT THE SILHI-LEBT AT CEA/SACLAY

Differential Cross Section Measurements in Ion-molecule Collisions

Survey Meter OD-01 Address: Phone: Fax: URL:

In vacuum ID beam line shielding commissioning and direct gasbremsstrahlung measurements at Synchrotron SOLEIL

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Radiation Safety at LCLS: The Photon Beam s Maximum Capability and Material Damage Potential

Status of the GERDA experiment

Beam. RF antenna. RF cable

High Intensity Operation and Control of Beam Losses in a Cyclotron based Accelerator

Development of a new MeV gamma-ray camera

Fig. 1 : Voltage vs hours graph for the 15 UD Pelletron

Bremsstrahlung and Ion Beam Current Measurements with SuSI ECR Ion Source

The photoneutron yield predictions by PICA and comparison with the measurements

DIANA A NEXT GENERATION DEEP UNDERGROUND ACCELERATOR FACILITY

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

The Compact Muon Beam Line

Accelerator Design and Construction Progress of TPS Project

Diagnostics Requirements for the ARIEL Low Energy Beam Transport

Cornell Injector Performance

and another with a peak frequency ω 2

The heavy ion irradiation facility at KVI-CART

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

UNIQUE SCIENCE ACADEMY

ILC Laser-wires. G A Blair, RHUL Snowmass 17 th August 2005

Calibration of the IXPE Instrument

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

Gamma ray coincidence and angular correlation

First neutrino beam and cosmic tracks. GDR neutrino

High Resolution Electron Spectrometry at the NESR. Ajay Kumar

8 th International Workshop on Radiation Safety at Synchrotron Radiation Sources

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

arxiv: v2 [physics.acc-ph] 21 Jun 2017

Future Light Sources March 5-9, 2012 Low- alpha mode at SOLEIL 1

CYCLOTRON DEVELOPMENT PROGRAM AT JYVÄSKYLÄ

ATLAS Tile Calorimeter Calibration and Monitoring Systems

SIMULATION OF LASER INDUCED NUCLEAR REACTIONS

RADIATION-METER TM-91/TM-92

Status of Proof-of-Principle Experiment of Coherent Electron Cooling at BNL

Shielding calculations for the design of new Beamlines at ALBA Synchrotron

Parametric down-conversion

Energy loss of alpha particles - Prelab questions

Measurement of Nucleon Strange Form Factors at High Q 2

LIQUID XE DETECTOR FOR MU E GAMMA SEARCH

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

Hands on LUNA: Detector Simulations with Geant4

Research with Synchrotron Radiation. Part I

Travels with a Cyclotron. David Parker University of Birmingham

Transcription:

Installation and test of the MEG Cockroft-Walton accelerator Carlo Bemporad, Matteo Corbo, Nicolino Curalli, Marco Grassi, Peter- Raymond Kettle, Hiroaki Natori, Angela Papa, Giovanni Signorelli PSI - INFN Pisa - ICEPP Tokyo MEG Experiment Review Meeting July 18, 2007

Calibrations We are prepared for complementary and redundant calibration methods Proton Accelerator Li(p,!)Be LiF target at COBRA center Alpha on wires K Bi 17.6MeV! Tl F Li(p,!1) at 14.6 MeV Li(p,!0) at 17.6 MeV ~daily calib. also for initial setup PMT QE & Att. L Cold GXe LXe " 0!!! " - + p! " 0 + n " 0!!! (55MeV, 83MeV) " - + p!! + n (129MeV) LH 2 target Xenon Calibration LED PMT Gain Higher V with light att. e + µ radiative decay! e µ # #! e - Lower beam intensity < 10 7 Is necessary to reduce pileups Laser relative timing calib. quelle Nickel! Generator off on Illuminate Xe from the back 9 MeV Nickel _-line NaI A few days ~ 1 week to get enough statistics Laser 2 Source (Cf) transferred by comp air! on/off

The MEG C-W accelerator γ-ray production by the reactions Li(p,γ)Be and B(p,γ)C Main method to check the energy scale and stability of the calorimeter on a daily basis LiF target is easier to prepare compared to Li alone but 19 F has other lines 3

Machine Schedule We were almost on schedule with respect to what was shown at the february meeting Review 02/07 Present Completion of manufacture ~ end-february 2007 end-february 2007 Acceptance Tests in Amersfoort NL with HVEE, INFN, PSI ~ mid-april 2007? 19-23 March 2007 Shipment to PSI ~ end-april? mid-may 2007 Machine Installation + Shipment/Guarantee Test ~ mid-april to mid-may 2007? mid May to end June 2007 4

5

6

Ready! Less than two months from the C-W delivery at PSI the proton accelerator and beam line are ready to enter into operation We are able to deliver protons to a target at the center of COBRA to generate 17.6 MeV calibration photons Two-fold Installation and acceptance test Beam line towards COBRA 7

Cockroft-Walton area The new area was completed and equipped Classification as Accelerator facility: subject to rules from: BAG Rules (Swiss Ministry of Health) PSI Health Physics & Safety Rules Strict Rules governing: Facility usage, operational personnel Schooling of personnel, maintainance & upkeep... πe5 area C-W area Certified Licence for Cockcroft-Walton Facility 8 up to Energy: 1 MeV Max. Current: 1 μa

Acceptance Alignment Current Energy Measurement with an Aluminum Faraday cup Li(p,γ)Be line excitation on thick target (5 µm) + NaI absolute energy calibration The alignment was checked with the usage of a quartz crystal A most reliable, simple and sensitive method for beam tuning and diagnosis Correlation of proprietary current meter and SCS2000 (na!) 9 µ = (444 ± 1) kev Γ = (6.8 ± 0.5) kev

Acceptance test summary Nominal Measured at PSI Terminal energy range 300-900 kev 200-1100 kev Energy ripple < 500 Vrms < 50 Vrms Angular divergence < (5 x 5) mrad 2 ~ (4 x 4) mrad 2 Spot size at 3 m < (3 x 3) cm 2 < 1 cm 2 Energy setting reproducibility 0.1 % ok Energy stability FWHM 0.1 % ok Range of current (1-100) µa (0.1-135) µa Current stability 3 % ok Current reproducibility 10 % ok Start-up time < 20 min < 15 min < 2 µsv/hr @ 1 µa < 0.1 µsv/h X-ray level from the tank (500 kev) < 5µSv/hr @ 100 µa < 0.1 µsv/h @ 50 µa - 0.5* - 3** µsv/h @ 1 µa X-ray level in the πe5 area - 14*** - 280* µsv/h @ 50 µa 10 * > 60 kev, on the Al Faraday cup ** > 10 kev, on the Al Faraday cup *** > 60 kev, 3 cm from the beam line

Acceptance test summary Nominal Measured at PSI Terminal energy range 300-900 kev 200-1100 kev Energy ripple < 500 Vrms < 50 Vrms Angular divergence < (5 x 5) mrad 2 ~ (4 x 4) mrad 2 Spot size at 3 m < (3 x 3) cm 2 < 1 cm 2 Energy setting reproducibility 0.1 % ok Energy stability FWHM 0.1 % ok Range of current (1-100) µa (0.1-135) µa Current stability 3 % ok Current reproducibility 10 % ok Start-up time 29 June 2007 < 20 by min contract! < 15 min < 2 µsv/hr @ 1 µa < 0.1 µsv/h X-ray level from the tank (500 kev) < 5µSv/hr @ 100 µa < 0.1 µsv/h @ 50 µa - 0.5* - 3** µsv/h @ 1 µa X-ray level in the πe5 area - 14*** - 280* µsv/h @ 50 µa 11 * > 60 kev, on the Al Faraday cup ** > 10 kev, on the Al Faraday cup *** > 60 kev, 3 cm from the beam line

Towards MEG area After this date we operated the machine by ourselves Successful mounting and operation of the proton beam line elements beam shutter - slits - collimators - straight insulated sections - gate valves Integration with the experiment slow control (SCS2000 - pressure, valve, currents, bellow system) Matching with the insertion system we move 4 mm/s => need 10 minutes to insert the system (40 W) to bo tested with the gas system in operation 12

Final Beam Line schematics COBRA edge position Horizontally deflecting permanent magnets Target insertion bellow system COBRA Pumping station Monitoring camera and slits Horizontally deflecting dipole Possibility to intoduce a quadrupole Pumping station and beam line vacuum monitoring Vertically deflecting dipole Beam shutter This beam line is the result of intensive tests The beam position was monitored with the quartz crystal MEG C-W area 13

At COBRA edge With the magnetic field on we have to adjust the horizontal and vertical position of the beam Horizontal ~ 1 A, Vertical ~ 100 ma (few 10s G) RED light = field ON 14

At COBRA center ~7 cm from the center We had a significant (~few cm) shift but with the help of dipoles and permanent magnets we could center the beam COBRA splits H + and H2 + 15

At COBRA center ~7 cm from the center A larger beam spot is more suitable for our case uniform target illumination less target consumption for delivered current Defocussing using accelerator extraction voltage we obtain a ~ 2 cm beam spot 16

Beam spot measurement CW-source probe voltage changes the current CW-extraction voltage changes the focussing Camera picture through theodolite grid Few mm at full focussing ~ 2 cm at maximum CW defocussing 2 cm 2 cm 1 cm 1 cm

Centering and Focussing Some difference between COBRA off and COBRA on Presence of stray fields Misalignment at COBRA of 2 mrad We have sufficient handles to compensate for this effect Usage of dipoles only COBRA focuses the beam Usage of C-W extraction voltage to defocus on target (to have a uniform distribution) at a sufficient level We reserve the possibility to test the usage of a defocussing (!) quadrupole. multiple scattering on thin foil ~1 week test planned 18

Time needed for Calibration 10 minutes inserting 10 minutes conditioning can go in parallel O(10 minutes) data taking at 30 Hz 20k events Rate (17.6 MeV) on LXe = 1.8 khz / µa 10 minutes extracting Alpha-source and LEDs can be done during extraction/insertion Daily operations Periodic Operations Rare Operations -Automatic or Manual turn-on procedure -Optimization of source parameters -Calibration procedure (Bellows + Insertion System introduction into COBRA beamshutter manipulation & reverse procedure) -Target (LiF) change when required Testing safety aspects (zone-interlocks etc.) -Pressure SF6-vessel filling/emptying - N2 flushing + evacuation -Pressure-vessel opening/closing - Ion-source replacement - H2-bottle replacement -Intervention on internal parts Trained Shifters + assistant Member of the C-W Group + assistant 19

Conclusion and perspectives The system is ready to deliver the desired beam at the desired intensity to calibrate the LXe calorimeter No dangerous radiation (x-rays) to the area due to the choice of materials Few things need to be investigated optimize optics w/all detectors inside test the usage of a quadrupole check target duration the usage of the crystal has been of invaluable help but won t be possible at the center of COBRA in the final beamline configuration multi-pixel target ~ One week C-W beam time Full integration with PSI safety interlocks Some new pneumatic elements foreseen (intermediate crystal, FCup) Test independently thanks to the separate C-W area 20

Back-up slides Next slides are only intended for back-up use.

Centering procedure

Beam centering misalignment of 1.2 mrad in x, and in y small accelerator misalignment and long lever arm (10 m) presence of residual fields (iron platform, neighbouring areas, steering magnets off...) partially compensates or masks 23

Dipoles in operation cobra edge horizontal dipole at 0.3 V (=100 ma, ~ 20 Gauss) vertical 0.0 (residual fields on vertical magnet compensate y) 24

Switch COBRA on beam towards Berg Notice different camera position RED light = field ON 25

Re-adjust horizontal dipole Horizontal dipole = 1.5 V Vertical = 0.1 V RED light = field ON 26

At COBRA center ~7 cm from the center We had a significant (~few cm) shift but with the help of dipoles and permanent magnets we could center the beam COBRA splits H + and H2 + 27

At COBRA center Defocussing using accelerator extraction voltage ~ 2 cm beam spot 28

in-run calibration It is possible to have a simultaneous µ & photon run check of the gamma line behaviour in true experimental condition Not exactly at the center of the detector Also alpha-sources trigger pulse shape discrimination tested w/real trigger boards at the Pisa PMT test facility 29

X-rays from the C-W Proton Induced X-ray Emission Each element emits caracteristics X-rays Medical Physics, geology, etc... σk T p4 Z 12 small brehmsstrahlung background Independent p-current normalization Nuclear reaction detected by dedicated hardware Sub-detector calibration Check of safe radiation level ok! MEG TN041 N nx = n p M 30 dtp T0 S(T )σ X (Tp ) p 0

Transport simulation Beam simulation with Transport Zmin= 0.00 m Zmax= 15.00 m Xmax= 5.0 cm Ymax= 5.0 cm Ap * 1.00 11-Jul-06 10:05:35 C E N 8D B O CC O B 6 7 B O C C O B 5 4 B O C C O B 3 2 B O C C O B 1 E C B C Q D F 1 1 D F Q 0. 1 9 0 5 71. 0-0. 5 0 0 0 05. 0 1. 5 0 0 0 00. 5 8. 0 0 0 0 05. 8 9. 7 5 0 0 05. 1 11 2. 7 5 00 00. 3 1 C C 3 D D 2 1 D